• Title/Summary/Keyword: Relative threshold

Search Result 243, Processing Time 0.027 seconds

Numerical modeling of rapid impact compaction in loose sands

  • Ghanbari, Elham;Hamidi, Amir
    • Geomechanics and Engineering
    • /
    • v.6 no.5
    • /
    • pp.487-502
    • /
    • 2014
  • A three dimensional finite element model was used to simulate rapid impact compaction (RIC) in loose granular soils using ABAQUS software for one impact point. The behavior of soil under impact loading was expressed using a cap-plasticity model. Numerical modeling was done for a site in Assalouyeh petrochemical complex in southern Iran to verify the results. In-situ settlements per blow were compared to those in the numerical model. Measurements of improvement by depth were obtained from the in-situ standard penetration, plate loading, and large density tests and were compared with the numerical model results. Contours of the equal relative density clearly showed the efficiency of RIC laterally and at depth. Plastic volumetric strains below the anvil and the effect of RIC set indicated that a set of 10 mm can be considered to be a threshold value for soil improvement using this method. The results showed that RIC strongly improved the soil up to 2 m in depth and commonly influenced the soil up to depths of 4 m.

AN APPLICATION OF PLASMA-POLYMERIZED YbPc$_2$ FILM: HUMIDITY SENSOR

  • Yamana, Masao;Kashiwazaki, Naoya
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.703-708
    • /
    • 1996
  • Humidity sensing cheracterisrics of vacuum deposited plasma poly merized $YbPc_2$ films were evaluated. In both films, humidity caused an increase of pro-ton conduction. Polymerised film shows a threshold fo humidity increase and its sensitivity diminishes more than $38^{\circ}C$ of relative humidity. Furthermore, for the polymerized film, two min. of resssponse time and 1 min. of recovery time are also obtained. The sensitivity between 10% and 85% of relative hum-idities is found to be one hundred higher than that of the vacuum deposited film.

  • PDF

A Spoofing Detection Scheme Based on Elevation Masked-Relative Received Power in GPS Receivers using Multi-band Array Antenna

  • Junwoo Jung;Hyunhee Won;Sungyeol Park;Haengik Kang;Seungbok Kwon;Byeongjin Yu;Seungwoo Seo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.2
    • /
    • pp.101-111
    • /
    • 2023
  • Many spoofing detection studies have been conducted to cope with the most difficult types of deception among various disturbances of GPS, such as jamming, spoofing, and meaconing. In this paper, we propose a spoofing detection scheme based on elevation masked-relative received power between GPS L1 and L2 signals in a system using a multi-band array antenna. The proposed scheme focuses on enabling spoofing to be normally detected and minimizes the possibility of false detection in an environment where false alarms may occur due to pattern distortion among elements of an array antenna. The pattern distortion weakens the GPS signal strength at low elevation. It becomes confusing to detect a spoofing signal based on the relative power difference between GPS L1 and L2, especially when GPS L2 has weak signal strength. We propose design parameters for the relative power threshold including beamforming gain, the minimum received power difference between L1 and L2, and the patch antenna gain difference between L1 and L2. In addition, in order to eliminate the weak signal strength of GPS L2 in the spoofing detection process, we propose a rotation matrix that sets the elevation mask based on platform coordinates. Array antennas generally do not have high usefulness in commercial areas where receivers are operated alone, but are considered essential in military areas where GPS receivers are used together with signal processing for beamforming in the direction of GPS satellites. Through laboratory and live sky tests using the device under test, the proposed scheme with an elevation mask detects spoofing signals well and reduces the probability of false detection relative to that without the elevation mask.

Creepage Distance Measurement Using Binocular Stereo Vision on Hot-line for High Voltage Insulator

  • He, Wenjun;Wang, Jiake;Fu, Yuegang
    • Current Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.348-355
    • /
    • 2018
  • How to measure the creepage distance of an insulator quickly and accurately is a problem for the power industry at present, and the noticeable concern is that the high voltage insulation equipment cannot be measured online in the charged state. In view of this situation, we develop an on-line measurement system of creepage distance for high voltage insulators based on binocular stereo vision. We have proposed a method of generating linear structured light using a conical off-axis mirror. The feasibility and effect of two ways to solve the interference problem of strong sunlight have been discussed, one way is to use bandpass filters to enhance the contrast ratio of linear structured light in the images, and the other way is to process the images with adaptive threshold segmentation and feature point extraction. After the system is calibrated, we tested the measurement error of the on-line measurement system with a composite insulator sample. Experimental results show that the maximum relative error is 1.45% and the average relative error is 0.69%, which satisfies the task requirement of not more than 5% of the maximum relative error.

The WISE Quality Control System for Integrated Meteorological Sensor Data (WISE 복합기상센서 관측 자료 품질관리시스템)

  • Chae, Jung-Hoon;Park, Moon-Soo;Choi, Young-Jean
    • Atmosphere
    • /
    • v.24 no.3
    • /
    • pp.445-456
    • /
    • 2014
  • A real-time quality control system for meteorological data (air temperature, air pressure, relative humidity, wind speed, wind direction, and precipitation) measured by an integrated meteorological sensor has been developed based on comparison of quality control procedures for meteorological data that were developed by the World Meteorological Organization and the Korea Meteorological Administration (KMA), using time series and statistical analysis of a 12-year meteorological data set observed from 2000 to 2011 at the Incheon site in Korea. The quality control system includes missing value, physical limit, step, internal consistency, persistence, and climate range tests. Flags indicating good, doubtful, erroneous, not checked, or missing values were added to the raw data after the quality control procedure. The climate range test was applied to the monthly data for air temperature and pressure, and its threshold values were modified from ${\pm}2{\sigma}$ and ${\pm}3{\sigma}$ to ${\pm}3{\sigma}$ and ${\pm}6{\sigma}$, respectively, in order to consider extreme phenomena such as heat waves and typhoons. In addition, the threshold values of the step test for air temperature, air pressure, relative humidity, and wind speed were modified to $0.7^{\circ}C$, 0.4 hPa, 5.9%, and $4.6m\;s^{-1}$, respectively, through standard deviation analysis of step difference according to their averaging period. The modified quality control system was applied to the meteorological data observed by the Weather Information Service Engine in March 2014 and exhibited improved performance compared to the KMA procedures.

Development of Sequential Sampling Plans for Tetranychus urticae in Strawberry Greenhouses (딸기 온실에서 점박이응애의 축차표본조사법 개발)

  • Choe, Hojeong;Kang, Juwan;Jung, Hyojin;Choi, Sira;Park, Jung-Joon
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.4
    • /
    • pp.427-436
    • /
    • 2017
  • A fixed-precision-level sampling plan was developed to establish control of the two-spotted spider mite, Tetranychus urticae, in two strawberry greenhouses (conventional plot, natural enemy plot). T. urticae was sampled by taking a three-leaflet leaf (1 stalk) from each plant (3 three-leaflet leaves) from each sampling position. Each leaflet was divided into three different units (1-leaflet, 2-leaflet, and 3-leaflet units) to compare relative net precision (RNP) values for selection of the appropriate sampling unit. The relative net precision values indicated that a 1-leaflet unit was more precise and cost-efficient than other units. The spatial distribution analysis was performed using Taylor's power law (TPL). Homogeneity of the TPL parameters in each greenhouse was evaluated by using the analysis of covariance (ANCOVA). A fixed-precision-level sequential sampling plan was developed using the parameters of TPL generated from the combined data of the conventional plot and natural enemy plot in a 1-leaflet sampling unit. Sequential classification sampling plans were also developed using the action threshold of 3 and 10 mites for pooled data. Using the results obtained in the independent data, simulated validation of the developed sampling plan by Resampling validation for sampling plan (RVSP) indicated a reasonable level of precision.

The Effects of Temperature on Heat-related Illness According to the Characteristics of Patients During the Summer of 2012 in the Republic of Korea

  • Na, Wonwoong;Jang, Jae-Yeon;Lee, Kyung Eun;Kim, Hyunyoung;Jun, Byungyool;Kwon, Jun-Wook;Jo, Soo-Nam
    • Journal of Preventive Medicine and Public Health
    • /
    • v.46 no.1
    • /
    • pp.19-27
    • /
    • 2013
  • Objectives: This study was conducted to investigate the relationship between heat-related illnesses developed in the summer of 2012 and temperature. Methods: The study analyzed data generated by a heat wave surveillance system operated by the Korea Centers for Disease Control and Prevention during the summer of 2012. The daily maximum temperature, average temperature, and maximum heat index were compared to identify the most suitable index for this study. A piecewise linear model was used to identify the threshold temperature and the relative risk (RR) above the threshold temperature according to patient characteristics and region. Results: The total number of patients during the 3 months was 975. Of the three temperature indicators, the daily maximum temperature showed the best goodness of fit with the model. The RR of the total patient incidence was 1.691 (1.641 to 1.743) per $1^{\circ}C$ after $31.2^{\circ}C$. The RR above the threshold temperature of women (1.822, 1.716 to 1.934) was greater than that of men (1.643, 1.587 to 1.701). The threshold temperature was the lowest in the age group of 20 to 64 ($30.4^{\circ}C$), and the RR was the highest in the ${\geq}65$ age group (1.863, 1.755 to 1.978). The threshold temperature of the provinces ($30.5^{\circ}C$) was lower than that of the metropolitan cities ($32.2^{\circ}C$). Metropolitan cities at higher latitudes had a greater RR than other cities at lower latitudes. Conclusions: The influences of temperature on heat-related illnesses vary according to gender, age, and region. A surveillance system and public health program should reflect these factors in their implementation.

Aberrant Expression of E-cadherin in Lung Tissues of Patients with Probable Lung Cancer

  • Yuan, Yu-Lin;Wang, Yu-Ming;Liu, Hua;Qin, Gui-Fang;Tang, Ai-Guo;Duan, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.10
    • /
    • pp.5149-5153
    • /
    • 2012
  • Introduction: This study assessed the relationship of E-cadherin mRNA and protein expression with the diagnosis of lung cancer with the aim of providing an auxiliary diagnostic method. Methods: Semi-quantitative nested RT-PCR and western blotting were applied to detect E-cadherin mRNA transcripts and protein, respectively, in 30 cases of diagnostic lung cancer, 30 cases of clinically suspected patients with lung cancer and 30 cases of other disease. Immunohistochemical staining was also used to detect E-cadherin. Results: Remarkably decreased levels of relative E-cadherin mRNA value and increased E-cadherin protein negativity were observed in probable lung cancer, when compared with possible lung cancer and others. With a threshold of 1.45, relative E-cadherin mRNA value showed a sensitivity of 90% and a specifity of 83% for the diagnosis of lung cancer. The combination of decreased relative E-cadherin mRNA value and negative E-cadherin protein increased the specificity and sensitivity. Conclusion: These data suggest that Chinese patients with diagnostic lung cancer have similar decreased levels of relative E-cadherin mRNA and E-cadherin protein value in the lung cancer tissues as in lung cancer patients in other countries. Measurement of relative E-cadherin mRNA and protein values in lung cancer tissues has potential for lung cancer diagnosis.

Comparison of absolute and relative thermal QST thresholds In the orofacial region of the young Korean women (젊은 한국 여성의 구강안면영역에서 절대적 온도역치와 상대적 온도역치간의 비교)

  • Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.4
    • /
    • pp.367-372
    • /
    • 2013
  • To diagnose sensory nerve damage, patient values for thermal stimuli as quantitative sensory test (QST) can be compared with the values of the general population (absolute reference data) or to values measured at contralateral unaffected side (relative reference data). It is well know that relative reference data are more sensitive for detecting sensory abnormality than absolute reference data. However it is still lack of the studies for comparisons between relative and absolute data. This study aimed to evaluate the validity of relative reference data and compare the sensitivities of the two approaches in the orofacial region. In 19 young Korean women as normal subjects, quantitative somatosensory thermotest were done in the forehead, cheek, mentum, lower lip and tongue tip bilaterally. After we get the standard deviations (SD) of average reference data and relative reference data, the ratios SD absolute data/SD relative data were calculated. Our study showed that relative reference data for side to side comparisons in the same patient have the high ratios than the absolute reference data, i.e. the side to side comparisons with relative reference data exhibit gain in sensitivity in assessment of sensory abnormality.

Effect of temperature on the development of the Common Grass Yellow, Eurema hecabe

  • Kim, Seonghyun;Park, Haechul;Park, Ingyun
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.31 no.2
    • /
    • pp.35-39
    • /
    • 2015
  • The developmental responses of insects to temperature are important considerations in gaining a better understanding of their ecology and life histories. Temperature-dependent phenology models permit examination of the effects of temperature on the geographical distributions, population dynamics, and management of insects. Measurements of insect developmental and survival responses to temperature pose practical challenges that depend on the chosen modality, variability among individuals, and high mortality rates near the lower and upper threshold temperatures. Different temperature levels can significantly affect larval development of Eurema hecabe. The development of E. hecabe reared on leaves of Lespedeza cuneata was investigated at three temperature regimes (20, 25, and 30℃), a relative humidity of 60%, and a light:dark photoperiod of 14:10 h. The developmental time from larva to adult was 34.3, 20.6, and 17.9 d at temperatures of 20, 25, and 30℃, respectively. Pupal rate was 47.6%, 47.6%, and 61.9% at temperatures of 20, 25, and 30℃, respectively. The developmental threshold temperature estimated from larva to pupae was 8.1℃ with 381.7 degree-days. There is an increasing need for a standardized manual for rearing this butterfly species based on adequate knowledge of its ecology.