• Title/Summary/Keyword: Relative position

Search Result 1,251, Processing Time 0.036 seconds

Review of Allowable Condition of the Discretionary not Covered Service (임의비급여 허용요건에 관한 검토)

  • Park, Tae-Shin
    • The Korean Society of Law and Medicine
    • /
    • v.13 no.2
    • /
    • pp.11-38
    • /
    • 2012
  • The Supreme Court stand in the position in specific lawsuit that it doesn't allow the discretionary not covered service, but recently in revocation suit of fine disposal that is imposed on medical fee of leukemia patient, it altered the existing adjudgement and admitted the discretionary not covered service exceptionally. It put forward the allowable condition roughly in that case. According as this alteration, it has become more important to embody the allowance conditions of exceptions. The Supreme Court presented three things, which are procedural condition, medical condition and subscriber's agreement. Concerning procedural condition, several present conciliation procedures are as follows: medical care benefit arret request, relative value conciliation etc, prior request on anti-cancer drug among chemicals which exceed acceptance criteria, request of non benefit object on common drugs. To be granted the existence of those system, there should be no obstacle to use that. Even if it were so, we should take circumstances into consideration; individual situation is unescapable concerning substance and urgency of the discretionary not covered service, process of the procedure, time required etc. Regarding medical condition, safety and effectiveness will be verified through evaluation procedures of new medical skill. About the necessity, the Supreme Court made clear through a sentence that it allow the discretionary not covered service, in case that needs to treat a patient out of the standard of medical benefit. Strict interpretation is right and it answer the purpose of the sentence that the supreme court permit the discretionary not covered service, exceptionally. We need to differentiate medical necessity and medical validity. Subscriber's agreement should holds true if it entails full explanation, and if it is preliminary, explicit and individual. On this account, it should be difficult to admit that someone agree effectively when he call for the affirmation that he is recipient of medical care. Reasonable expense needs to be a part of review whether the agreement is valid. Meanwhile If we adjust system of medical expense and eventually reorganize a fee for consultation payment system (Fee-for-service controlled by item to DRG (Diagnosis Related Groups)), controversial area of the discretionary not covered service will be decreased and that will guarantee the discretion of the doctor.

  • PDF

Inspection of the Nuclear Fuel Rod Deformation using an Image Processing (영상처리를 이용한 핵연료봉의 변형 검사)

  • Cho, Jai-Wan;Choi, Young-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.1
    • /
    • pp.91-96
    • /
    • 2010
  • In this paper, a deformation measurement technology of the nuclear fuel rod is proposed. The deformation measurement system include high definition CCD or CMOS image sensor, lens, semiconductor laser line beam marker, and optical & mechanical accessories. The basic idea of the deformation measurement is to illuminate the outer surface of the fuel rod with collimated laser line beam at an angle of 45 degrees or higher. The relative motion of the fuel rod in the horizontal direction causes the illuminated laser line beam to move vertically along the surface of the fuel rod. The resulting change of laser line beam position in the surface of the fuel rod is imaged as the parabolic beam in the high definition CCD or CMOS image sensor. From the parabolic beam pattern, the ellipse model is extracted. And the slope of the long and the short axis of the ellipse model is found. The crossing point between the saddle point of the parabolic beam and the long & short axis of the ellipse model is taken as the feature of the deformed fuel rod. The vertical offset between feature points before and after fuel rod deformation is calculated. From the experimental results, $50\;{\mu}m$ inspection resolution is acquired using the proposed method, which is three times enhanced than the conventional criterion ($150\;{\mu}m$) of the guide for the inspection of the nuclear fuel rod.

Palaeomgnetic Study on the Cretaceous Rocks in the Konchonri Area of the Northern Milyang Subbasin, Korea (밀양소분지 건천리 일원의 백악기 암석에 대한 고자기 연구)

  • Kang, Hee-Cheol;Kim, In-Soo;Yun, Sung-Hyo
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.1
    • /
    • pp.1-12
    • /
    • 2000
  • A palaeomagnetic study was carried out on Early through Late Cretaceous sandstones and volcanic sequences (the Songnaedong Formation, Chaeyaksan Volcanics, Konchonri Formation, and Jusasan Andesite it ascending order) from Konchonri area in the northern Milyang subbasin of the Kyongsang Basin, Korea. A high-temperature stable remanence with direction of $d=22.9^{\circ},\;i=59.1^{\circ}\;({\alpha}_{95}=3.0^{\circ})$ has been isolated and a corresponding pole was $71.6^{\circ}N,\;199.6^{\circ}E\;(A_{95}=4.2^{\circ})$. The characteristic high-temperature component resides in both hematite and magnetite. The primary nature of this remanence is confirmed from positive fold and reversals tests, The palaeopole is consistent with those of the Hayang Group in other parts of the Kyongsang Basin. A comparison of the palaeomagnetic pole position from the studied area with the contemporary pole from China west of the Tan-Lu fault presents that Konchonri area has experienced little latitudinal displacement nor vertical-axis block rotation relative to the Chinese blocks since the Cretaceous. Based on the formations indicating dual polarity, radiometric and paleontologic data, the magnetostratigraphic age of the studied sequence from the Songnedong Formation to the Jusasan Andesite ranges from upper Albian to lower Campanian reverse polarity chronozone. On the other hand, volcanic samples of the Chaeyaksan Volcanics and the Jusasan Andesite showed the scattered directions considered in group, even though individual sample showed a stable remanent magnetization in response to thermal demagnetization. It indicates that they have been reworked after acquisition of the stable remanent magnetization.

  • PDF

IoT Based Intelligent Position and Posture Control of Home Wellness Robots (홈 웰니스 로봇의 사물인터넷 기반 지능형 자기 위치 및 자세 제어)

  • Lee, Byoungsu;Hyun, Chang-Ho;Kim, Seungwoo
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.636-644
    • /
    • 2014
  • This paper is to technically implement the sensing platform for Home-Wellness Robot. First, self-localization technique is based on a smart home and object in a home environment, and IOT(Internet of Thing) between Home Wellness Robots. RF tag is set in a smart home and the absolute coordinate information is acquired by a object included RF reader. Then bluetooth communication between object and home wellness robot provides the absolute coordinate information to home wellness robot. After that, the relative coordinate of home wellness robot is found and self-localization through a stereo camera in a home wellness robot. Second, this paper proposed fuzzy control methode based on a vision sensor for approach object of home wellness robot. Based on a stereo camera equipped with face of home wellness robot, depth information to the object is extracted. Then figure out the angle difference between the object and home wellness robot by calculating a warped angle based on the center of the image. The obtained information is written Look-Up table and makes the attitude control for approaching object. Through the experimental with home wellness robot and the smart home environment, confirm performance about the proposed self-localization and posture control method respectively.

RADIOGRAPHIC STUDY OF ERUPTION CHARACTERISTICS FOR UPPER PERMANENT 1ST MOLAR CLASSIFIED AS IRREVERSIBLE ECTOPIC ERUPTION (비가역성 이소맹출로 분류된 상악 제1대구치의 맹출 특성에 관한 방사선학적 연구)

  • Im, El;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.4
    • /
    • pp.556-562
    • /
    • 2009
  • Ectopic eruption of the maxillary first permanent molar means that the molar erupts out of the normal position and is arrested in its eruption by the second primary molar. This local eruption disturbance results in a premature atypical resorption on the distal part of the second primary molar. In most irreversible cases, the second primary molar is lost prematurely, either by spontaneous exfoliation or by extraction, In cases of doubt as to whether the eruption is of the irreversible type or not, careful radiographic observation period for a few months would be valuable in evaluating the possibilities of the tooth's freeing itself. The purpose of this study was to determine the characteristics and occurrence of the ectopic eruption of the maxillary first permanent molar. A descriptive, observational, retrospective study was done using the radiographs of 25 conseutive patients, who were in the first phase of mixed dentition. A method was designed to evaluate the amount of pathologic resorption of the second maxillary primary molar and the mesial angulation of the first permanent molar. The study showed that the most important etiologic factor was the eruption path or mesial angulation of the first permanent molars relative the chosen reference lines.

  • PDF

Retrospective Study of GS II Implant(Osstem) with an Internal Connection with Microthreads (Micro thread를 포함한 GSII RBM임플란트(Osstem)의 후향적 임상연구)

  • Chee, Young-Deok;Lee, Jae-Hwan;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.417-429
    • /
    • 2009
  • Since the introduction of the concept of osseointegration in dental implants, high long-term success rates have been achieved and accepted as viable option for the treatment of fully and partially edentulous patients. Although the use of domestic implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. 96 endosseous implants placed in 31 patients at Wonkwang University Sanbon Dental Hospital were examined to determine the effect of various factors on implant survival rate and marginal bone loss, through clinical and radiographic results. The design of endosseous implant used to this study is straight with the microthread.(GS II RBM Fixture) 1. 3 fixtures were lost, resulting in 96.9% cumulative survival rate. 2. Survival rate in fifties was significantly lower (93.6%) and no significant difference in marginal bone loss was found according to gender. 3. Survival rates were 95.6% in the maxillary molar area and 97.3% in the mandible molar area. 4. No significant difference in survival rate was found according to presence of bone grafts, type of prostheses, implant position, and length and diameter of implant. 5. A factor influencing marginal bone loss was presence of type of prostheses, while facters such a length, diameter of fixture and bone grafts had no statistically significant effect on crestal bone loss. This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

Fabrication of the Noninvasive Tube Voltage Meter of Radiotherapy Simulator and Its Performance Analysis (방사선치료 시뮬레이터의 비접속형관전압계 제작과 성능분석)

  • Kim, Jong-Eon;Yoon, Chun-Sil;Kim, Sung-Hyun;Park, Chang-Hee;Cha, Byung-Youl
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.201-206
    • /
    • 2006
  • In this study, we have fabricated the noninvasive tube voltage meter which can observe the waveform of tube voltage and measure the tube voltage by using the Intensity of X-ray beam irradiated from radiotherapy simulator and also investigated the feasibility for clinical applications. Two pin photodiodes acting as X-ray detectors were arranged in parallel at the position of ${\pm}1.4cm$ in the y-axis of X-ray field and the aluminum filters with different thickness were placed above them. Using this detector, we could get the ratio ($r_{eff}$) of the relative output voltage which is proportional to the thickness of the filters. And the logarithm of effective peak tube voltage ($InkV_{p,eff}$) was obtained by Victoreen's NERO 6000M used as reference tube voltage meter. From the linear regression analysis of $r_{eff}$ and In $kV_{p,eff}$ the correlation coefficient (r) of linear equation was obtained to be 0.996 for the calibration of the tube voltage meter. Therefore, we suggest that the noninvasive tube voltage meter fabricated in this study can be used for clinical applications due to Its high accuracy.

  • PDF

A study on the effect of the locations of pile tips on the behaviour of piles to adjacent tunnelling (말뚝선단의 위치가 터널근접 시공에 의한 말뚝의 거동에 미치는 영향에 대한 연구)

  • Lee, Cheol-Ju;Jeon, Young Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.91-105
    • /
    • 2015
  • In the current work, a series of three-dimensional (3D) finite element analyses have been performed to study the effects of the locations of pile tips on the behaviour of single piles to adjacent tunnelling. In the numerical modelling, several key issues, such as tunnelling-induced pile head settlements, axial pile forces, interface shear stresses and apparent factors of safety have been studied. When the pile tips are inside the influence zone which considers the relative pile tip location with respect to the tunnel position, tunnelling-induced pile head settlements are larger than those computed from the greenfield condition. However, when the pile tips were outside the influence zone, an opposite trend was observed. When the pile tips were inside the influence zone, tunnelling-induced tensile pile forces developed; however, when the pile tips were outside the influence zone, tunnelling-induced compressive pile forces were mobilised, associated with larger settlements of the surrounding soil than the pile settlements. It has been shown that the increases in the tunnelling-induced pile head settlements have resulted in reductions of the apparent factor of safety by about 50% when the pile tips are inside the influence zone, therefore severly affecting the serviceability of piles. The pile behaviour, when considering the location of pile tips with regards to the influence zone, has been analysed in great detail by taking the tunnelling-induced pile head settlements, axial pile force and apparent factor of safety into account.

Extended Cartoon Rendering using 3D Texture (3차원 텍스처를 이용한 카툰 렌더링의 만화적 스타일 다양화)

  • Byun, Hae-Won;Jung, Hye-Moon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.8
    • /
    • pp.123-133
    • /
    • 2011
  • In this paper, we propose a new method for toon shading using 3D texture which renders 3d objects in a cartoon style. The conventional toon shading using 1D texture displays shading tone by computing the relative position and orientation between a light vector and surface normal. The 1D texture alone has limits to express the various tone change according to any viewing condition. Therefore Barla et. al. replaces a 1D texture with a 2D texture whose the second dimension corresponds to the view-dependent effects such as level-of-abstraction, depthof-field. The proposed scheme extends 2D texture to 3D texture by adding one dimension with the geometric information of 3D objects such as curvature, saliency, and coordinates. This approach supports two kinds of extensions for cartoon style diversification. First, we support "shape exaggeration effect" to emphasize silhouette or highlight according to the geometric information of 3D objects. Second, we further incorporate "cartoon specific effect", which is examples of screen tone and out focusing frequently appeared in cartoons. We demonstrate the effectiveness of our approach through examples that include a number of 3d objects rendered in various cartoon style.

An Adaptive Time Delay Estimation Method Based on Canonical Correlation Analysis (정준형 상관 분석을 이용한 적응 시간 지연 추정에 관한 연구)

  • Lim, Jun-Seok;Hong, Wooyoung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.548-555
    • /
    • 2013
  • The localization of sources has a numerous number of applications. To estimate the position of sources, the relative delay between two or more received signals for the direct signal must be determined. Although the generalized cross-correlation method is the most popular technique, an approach based on eigenvalue decomposition (EVD) is also popular one, which utilizes an eigenvector of the minimum eigenvalue. The performance of the eigenvalue decomposition (EVD) based method degrades in the low SNR and the correlated environments, because it is difficult to select a single eigenvector for the minimum eigenvalue. In this paper, we propose a new adaptive algorithm based on Canonical Correlation Analysis (CCA) in order to extend the operation range to the lower SNR and the correlation environments. The proposed algorithm uses the eigenvector corresponding to the maximum eigenvalue in the generalized eigenvalue decomposition (GEVD). The estimated eigenvector contains all the information that we need for time delay estimation. We have performed simulations with uncorrelated and correlated noise for several SNRs, showing that the CCA based algorithm can estimate the time delays more accurately than the adaptive EVD algorithm.