• Title/Summary/Keyword: Relative Velocity

Search Result 1,066, Processing Time 0.035 seconds

Modeling of a Dynamic Membrane Filtration Process Using ANN and SVM to Predict the Permeate Flux (ANN 및 SVM을 사용하여 투과 유량을 예측하는 동적 막 여과 공정 모델링)

  • Soufyane Ladeg;Mohamed Moussaoui;Maamar Laidi;Nadji Moulai-Mostefa
    • Membrane Journal
    • /
    • v.33 no.1
    • /
    • pp.34-45
    • /
    • 2023
  • Two computational intelligence techniques namely artificial neural networks (ANN) and support vector machine (SVM) are employed to model the permeate flux based on seven input variables including time, transmembrane pressure, rotating velocity, the pore diameter of the membrane, dynamic viscosity, concentration and density of the feed fluid. The best-fit model was selected through the trial-error method and the two statistical parameters including the coefficient of determination (R2) and the average absolute relative deviation (AARD) between the experimental and predicted data. The obtained results reveal that the optimized ANN model can predict the permeate flux with R2 = 0.999 and AARD% = 2.245 versus the SVM model with R2 = 0.996 and AARD% = 4.09. Thus, the ANN model is found to predict the permeate flux with high accuracy in comparison to the SVM approach.

ML-based prediction method for estimating vortex-induced vibration amplitude of steel tubes in tubular transmission towers

  • Jiahong Li;Tao Wang;Zhengliang Li
    • Structural Engineering and Mechanics
    • /
    • v.90 no.1
    • /
    • pp.27-40
    • /
    • 2024
  • The prediction of VIV amplitude is essential for the design and fatigue life estimation of steel tubes in tubular transmission towers. Limited to costly and time-consuming traditional experimental and computational fluid dynamics (CFD) methods, a machine learning (ML)-based method is proposed to efficiently predict the VIV amplitude of steel tubes in transmission towers. Firstly, by introducing the first-order mode shape to the two-dimensional CFD method, a simplified response analysis method (SRAM) is presented to calculate the VIV amplitude of steel tubes in transmission towers, which enables to build a dataset for training ML models. Then, by taking mass ratio M*, damping ratio ξ, and reduced velocity U* as the input variables, a Kriging-based prediction method (KPM) is further proposed to estimate the VIV amplitude of steel tubes in transmission towers by combining the SRAM with the Kriging-based ML model. Finally, the feasibility and effectiveness of the proposed methods are demonstrated by using three full-scale steel tubes with C-shaped, Cross-shaped, and Flange-plate joints, respectively. The results show that the SRAM can reasonably calculate the VIV amplitude, in which the relative errors of VIV maximum amplitude in three examples are less than 6%. Meanwhile, the KPM can well predict the VIV amplitude of steel tubes in transmission towers within the studied range of M*, ξ and U*. Particularly, the KPM presents an excellent capability in estimating the VIV maximum amplitude by using the reduced damping parameter SG.

Monitoring North Korea Nuclear Tests: Comparison of 1st and 2nd Tests (북한 핵실험 모니터링 : 1, 2차 비교)

  • Chi, Heon-Cheol;Park, Jung-Ho;Kim, Geun-Young;Che, Il-Young;Sheen, Dong-Hoon;Shin, Jin-Soo;Cho, Chang-Soo;Lee, Hee-Il
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.243-248
    • /
    • 2010
  • Two suspicious events, which were claimed as underground nuclear tests by North Korea, were detected in the northern Korean Peninsula on October 9, 2006 and May 25, 2009. The KIGAM and Korea-China Joint seismic stations are distributed uniformly along the boundaries between North Korea and adjacent countries. In this study, the data from broadband stations with the distance of 200 to 550 km from the test site are used to analyze and compare two nuclear tests of North Korea. By comparing the time differences of the Pn-wave arrival times of 1st and 2nd tests at multiple stations, the relative locations of two test sites could be calculated precisely. From the geometrical calculation with the velocity of Pn wave $V_{Pn}$ = 8 km/s, the 2nd test site is estimated to move in the WNW direction from 1st one with the distance of 2 km. Body wave magnitude, mb of the 2nd test, which was announced officially as the network average of 4.5, varies widely with the directional location of stations from 4.1 to 5.2. The magnitude obtained from Lg wave, $m_b$(Lg), shows less variation between 4.3 to 4.7 with the average of 4.6. The moving-window spectra of time traces of 1st and 2nd tests show very similar pattern with different scale level. In addition, the corner frequencies of P wave of 1st and 2nd tests at each station show no or negligible difference. This indicates the burial depths of two tests might be very similar. The relative yield amount of the 2nd test is estimated 8 times larger than that of the 1st from the weighted average of ground-velocity amplitude ratios.

Development of an Aerodynamic Simulation for Studying Microclimate of Plant Canopy in Greenhouse - (2) Development of CFD Model to Study the Effect of Tomato Plants on Internal Climate of Greenhouse - (공기유동해석을 통한 온실내 식물군 미기상 분석기술 개발 - (2)온실내 대기환경에 미치는 작물의 영향 분석을 위한 CFD 모델개발 -)

  • Lee In-Bok;Yun Nam-Kyu;Boulard Thierry;Roy Jean Claude;Lee Sung-Hyoun;Kim Gyoeng-Won;Hong Se-Woon;Sung Si-Heung
    • Journal of Bio-Environment Control
    • /
    • v.15 no.4
    • /
    • pp.296-305
    • /
    • 2006
  • The heterogeneity of crop transpiration is important to clearly understand the microclimate mechanisms and to efficiently handle the water resource in greenhouses. A computational fluid dynamic program (Fluent CFD version 6.2) was developed to study the internal climate and crop transpiration distributions of greenhouses. Additionally, the global solar radiation model and a crop heat exchange model were programmed together. Those models programmed using $C^{++}$ software were connected to the CFD main module using the user define function (UDF) technology. For the developed CFD validity, a field experiment was conducted at a $17{\times}6 m^2$ plastic-covered mechanically ventilated single-span greenhouse located at Pusan in Korea. The CFD internal distributions of air temperature, relative humidity, and air velocity at 1m height were validated against the experimental results. The CFD computed results were in close agreement with the measured distributions of the air temperature, relative humidity, and air velocity along the greenhouse. The averaged errors of their CFD computed results were 2.2%,2.1%, and 7.7%, respectively.

Studies on Food Preservation by Controlling Water Activity III. Quality Changes of Fish Meat during Drying and Storage (식품보장과 수분활성에 관한 연구 3. 어육의 건조 및 저장중의 품질)

  • HAN Bong-Ho;LEE Jong-Gab;BAE Tae-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.3
    • /
    • pp.181-189
    • /
    • 1983
  • A study on the qualify changes of fish meat during drying and storage has been carried out with filefish meat. Filefish meat was dried in a forced air dryer at 40 and $55\%$ for 20 hours with an air velocity of 0.4 m/sec under different conditions of relative air humidities in the range of 10 to $50\%$. The dried fish meat was stored at $30^{\circ}C$ in chambers with constant relative humidities controlled by the use of conditioned air stream passing through the saturated salt solutions. The qualify of filefish meat was evaluated with the brown color densities developed by lipid oxidation and Maillard reaction. Changes of viable cell count during drying and storage were also discussed. The predominant reaction for the brown color developed during the study period was the lipid oxidation. The lipid oxidation rate during drying at constant temperature was appreciably affected by water activities at the drying surfaces of filefish meat during the falling drying rate period. The lipid oxidation rate was the slowest under the condition of the relative air humidity of around $30\%$. In samples stored at water activity of 0.33, the lipid oxidation rate was retarded remarkably in comparison with the samples with lower or higher water activities. The addition of $1\%$ table salt, $1.5\%$ D-sorbitol and $6\%$ sucrose slightly lowered the water activity with the slowest lipid oxidation rate. Such additives resulted the increase of the water soluble brown color densities, which seemed due to the increase of mobility of the water soluble substances by the result of the increase of equilibrium water content. Microflora of the samples immediately after drying consisted of ca. $30\%$ of coccus types, ca. $65\%$ of rod types and ca. $5\%$ of molds and yeasts. During the storage of the samples with a water activity of 0.76, the ratio of the coccus types to the total microflora was increased remarkably while that of the Gram negative non-spore rod types was decreased. The ratios of the Gram positive rod types, molds and yeasts during the storage were nearly constant.

  • PDF

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

Analysis of Tidal Asymmetry and Flood/Ebb Dominance around the Yeomha Channel in the Han River Estuary (한강하구 염하수로 주변에서의 조석·조류 비대칭과 창·낙조 우세 분석)

  • Yoon, Byung-Il;Woo, Seung-Buhm
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.9
    • /
    • pp.915-928
    • /
    • 2012
  • Han River estuary (HRE) is located at the middle of the western coast of Korea, and tidal currents were measured at 4 stations in this estuary during the winter season, and previously observed tide data was analyzed. The results of amplitude ratio of $M_4/M_2$ showed that increasing upward to estuary in the HRE. Tide harmonic constants of relative phase $2M_2-M_4$ represent flood dominance, with under 180 degree. But this method has a limit of analysis that typically based on the non-linear distortion of the tidal current in tidal lagoon system where freshwater discharge is assumed to be relatively small. The results of statistically tidal current data indicated that ebb current velocity would be great unlike tide data. Ebb and flood duration time is calculated by slack time of tidal current showed that ebb duration time is longer than flood. The results of correlation of analysis show high value (0.9) between tidal current stations from Incheon harbor to north entrance of Yeomha channel. We reconstructed to find the reasons for the features of ebb dominance the results of harmonic analysis. As major component ($M_2$) in combination with shallow water component ($M_4$), the tidal curve was presented flood dominance that has a flood current is stronger. However, these curve were changed to ebb dominance add up the non-harmonic components that had ebb direction flow by calculated tidally averaged current. The characteristic of enhancement on ebb is showed around the Yeomha channel in the HRE, because averaged flow which acts seaward such as long-term tidal current components due to non-linear effect and freshwater which overcome the flood current.

Estimating the Yield of Potato Non-Mulched Using Climatic Elements (기상자료를 이용한 무피복 재배 감자의 수량 예측)

  • Choi, Sung-Jin;Lee, An-Soo;Jeon, Shin-Jae;Kim, Kyeong-Dae;Seo, Myeong-Cheol;Jung, Woo-Suk;Maeng, Jin-Hee;Kim, In-Jong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.59 no.1
    • /
    • pp.89-96
    • /
    • 2014
  • We aimed to evaluate the effects of climatic elements on potato yield and create a model with climatic elements for estimating the potato yield, using the results of the regional adjustment tests of potato. We used 86 data of the yield data of a potato variety, Sumi, from 17 regions over 11 years. According to the results, the climatic elements showed significant level of correlation coefficient with marketable yield appeared to be almost every climatic elements except wind velocity, which was daily average air temperature (Tave), daily minimum air temperature (Tmin), daily maximum air temperature(Tmax), daily range of air temperature (Tm-m), precipitation (Prec.), relative humidity (R.H.), sunshine hours (S.H.) and days of rain over 0.1 mm (D.R.) depending on the periods of days after planting or before harvest. The correlations between these climatic elements and marketable yield of potato were stepwised using SAS, statistical program, and we selected a model to predict the yield of marketable potato, which was $y=7.820{\times}Tmax_-1-6.315{\times}Prec_-4+128.214{\times}DR_-8+91.762{\times}DR_-3+643.965$. The correlation coefficient between the yield derived from the model and the real yield of marketable yield was 0.588 (DF 85).

Study on Structural Integrity and Dynamic Characteristics of Knuckle Parts of KTX Anti-Roll Bar (KTX 고속열차 안티롤바 너클부의 동특성 및 구조 안전성 평가)

  • Jeon, Kwang Woo;Shin, Kwang Bok;Kim, Jin Woo;Jeong, Yeon Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.8
    • /
    • pp.1035-1041
    • /
    • 2013
  • To evaluate the structural integrity and dynamic characteristic of the knuckle part of a KTX anti-roll bar, an experimental and a numerical approach were used in this study. In the experimental approach, the acceleration and strain data for the knuckle parts of the KTX and KTX-SANCHUN anti-roll bar were respectively measured to evaluate and compare its structural dynamic characteristics under the operating environments of the Honam line. In the numerical approach, the evaluation of its structural integrity was conducted using LS-DYNA 3D, and then, the reliability of the finite element model used was ensured by a comparative evaluation with the experiment. The numerical results showed that the stress and velocity field of the knuckle part composed of a layered structure of a thin steel plate and rubber were more moderate than those of the knuckle part made of only a thick steel block owing to the reduction of relative contact between the knuckle and the connecting rod. It was found that the knuckle part made of a thin steel plate and rubber was recommended as the best solution to improve its structural integrity resulting from the elastic behavior of the KTX anti-roll bar being enabled under a repeating external force.

The Activation Plan of Variable Speed Control of Considering Urban Freeway Continuos Traffic Characteristics (In Busan Metropolitan City) (도시고속도로 연속류의 교통특성을 고려한 가변속도제어 활성화 방안 - 부산광역시를 중심으로 -)

  • Jeong, Yong-Hwa;Choi, Yang-Won;Lim, Chang-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.627-635
    • /
    • 2014
  • Currently the highest speed limit on the road traffic congestion or because you can not cope with climate change to cause a traffic accident may be a factor. According to the Road Traffic Act as well as 20% to 50% in case of inclement weather, but the driver must slow speed left to the judgment of the difficulties, and to slow the vehicle and the relative velocity between the vehicle does not run longer be a big influence on the environment and safety. Thus, variable speed control for drivers on the road, specify the appropriate maximum speed limit in bad weather It keeps motorists slowed the run rate to prevent accidents or reduce the severity of accident damage is expected to be possible. The purpose of this study is the frequent traffic accidents Continuous Busan (City Freeway) around the variable speed control in the appropriate sections so that it can be done by analyzing the characteristics of traffic accidents were the severity of the accident. Highway and urban environment, the geometry of the structure because it has a lot of Curved planar point compared to wet and dry road surfaces by simulated rain wet had bom the more the speed the greater the risk of an accident was the result. Based on these results, the primary section, first urban highway tunnel, near the lamp, near Toll Plaza, near binary Outlet after considering various factors such as speed reduction is needed in the first period by conducting awareness and recognize the need for the participation of the driver and the future city installation and operation of highways in all sectors is expected to be expanded.