• Title/Summary/Keyword: Relative Thermal Control

Search Result 90, Processing Time 0.036 seconds

Evapotranspirations of Lettuce and Cucumber by Cropping Systems in Greenhouse (시설재배 상추 및 오이의 재배방식별 증발산량)

  • 남상운;이남호;전우정;황한철;홍성구;허연정
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.168-175
    • /
    • 1997
  • In greenhouse, data on evapotranspiration or water consumption is important for the rational water management, irrigation planning, thermal environment analysis, and watering automation. But little investigations have been attempted to make clear the characteristics of water consumption in greenhouse. In this paper, evapotransplrations of lettuce and cucumber by cropping systems were investigated. And the correlations among evapotranspiration, pan evaporation, solar radiation, mean air temperature, and minimum relative humidity were analyzed. Experimental cropping systems of lettuce were soil culture and NFT system. Those of cucumber were soil culture, perlite culture, and rockwool culture. Total water consumption of lettuce was 2.62$\ell$/plant in soil culture and 1.71$\ell$/plant in NFT system. That of cucumber was 45.22$\ell$/plant in soil culture, 27.45$\ell$/plant in rockwool culture and 29.06$\ell$/plant in perlite culture. Therefore total water consumption of soil culture showed higher than soilless culture.

  • PDF

Effect of Leaf Aqueous Extracts from Some Gymnosperm Plant on the Seed Germination, Seedling Growth and Transplant of Hibiscus syriacus Varieties (수종 나자식물의 잎 수용 추출액이 무궁화의 품종별 종자발아와 유식물 및 초기생장에 미치는 영향)

  • 배병호;김용옥
    • The Korean Journal of Ecology
    • /
    • v.26 no.1
    • /
    • pp.39-47
    • /
    • 2003
  • The leaf aqueous extracts from five gymnosperms plant were investigated for allelopathy with five Hibiscus syriacus varieties. The leaf aqueous extract of Pinus rigida had the highest total phenolic compound of 2.21mg/L, whereas the soil under Pinus koraiensis canopy had the highest total phenolic compound of 1.38mg/L. Fourteen phenolic compounds were isolated from five gymnosperm plants by HPLC. Among them, phenolic compounds were the highest in P. rigida (320.56 g/mg) with the primary compound 5-sulfosalicylic acid (312.55 g/mg). The correlation between leaf total phenolic compound and pH was not significant, while the total phenolic compound of the leaf extract changed soil pH. The relative seed germination of H. syriacus varieties showed 25% was threshold concentration. The germination rates of varieties were similar to the control group or showed slight stimulation to treatment of P. koraiensis extract. H. syriacus Cambanha was similar to the control group or showed stimulation in all treated groups. H. syriacus Seohohyang showed stimulation in both root and shoot growth compared to the control group. In other varieties except Seohohyang, shoot growth was similar to the control group, while root growth was stimulated in all treated groups. The extracts of tested gymnosperms showed significantly more stimulation to transplanted Seohohyang seedlings, whereas others were similar to control or inhibited in the greenhouse. The dry weight of Seohohyang was greater in all treated groups than the control group, while other varieties were inhibited. All gymnosperm extracts stimulated the chlorophyll contents of Seohohyang and H. syriacus Koyoro but other varieties were not significantly affected. Accordingly, it is suggested that Seohohyang seems the most desirable when planted within these five gymnosperms.

Analysis of Cooling Effect on the Plastic Film Cover of Greenhouse Module Depending on the Shade and Water Curtain (온실지붕 차광과 수막 수준에 따른 냉방효과 분석)

  • Kim, Young-Bok;Park, Joong-Chun;Lee, Seung-Kyu;Kim, Sung-Tae;La, Woo-Jung;Huh, Moo-Ryong;Jeong, Sung-Woo
    • Journal of Bio-Environment Control
    • /
    • v.15 no.4
    • /
    • pp.306-316
    • /
    • 2006
  • In this study, the effect of the shade level, water flow rate applied to the shades and the temperature of water on the greenhouse cooling was investigated depending on the shade level of 0, 35, 55, 75%, and water flow rate and water temperature by the test on the small wooden frames to find out the low cost cooling method. With increasing of the dry bulb temperature of outside air, the dry bulb temperature in the wooden frames increased. For the frames with the shade and water, inside temperatures of the frames were lower of -0.2$\sim$-1.2$^{\circ}C$ than the temperature of the outside air and higher than the water temperature. For the frames without water, inside temperatures of the frames were higher of 1.7$\sim$4$^{\circ}C$ than the outside and not affected by the shade level very much. The water flow rate and the temperature of the water were not the important factors to decrease the inside temperatures in the frames. The black globe temperature became lower with increasing of shade level. The shade frames with water curtain showed the best cooling effect because of reducing thermal radiation and cooling the plastic film cover. The surface temperatures of the plastic film cover for the water supplied modules became lower with increasing of the shade level. The relative humidity was decreased with the dry bulb temperature in the frame increasing and not affected by the dry bulb temperature of the outside air for the frames with the shade and water.

Analysis on the Characteristics of Ventilation and Cooling for Greenhouses Constructed in Reclaimed Lands (간척지 온실의 환기 및 냉방 특성 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.26 no.3
    • /
    • pp.181-187
    • /
    • 2017
  • The purpose of this study was to provide basic data for development of environmental design technology for greenhouses constructed in reclaimed lands. The climatic conditions around seven major reclaimed land areas with a plan to install advanced horticultural complexes in Korea were analyzed. The characteristics of natural ventilation and temperature rise through the thermal environment measurement of the greenhouse in Saemangeum were analyzed. The part to be applied to the environmental design of the greenhouses in reclaimed lands were reviewed. Results of comparing the ventilation rate of the greenhouse according to the presence or absence of plants showed the greenhouse with plants had the lower ventilation rate, but the smaller rise of indoor temperature due to the evapotranspiration of plants. In the greenhouse with plants, the number of air changes was in the range of 0.3 to 0.9 volumes/min and the average was 0.7 volumes/min. The rise of indoor temperature relative to outdoor temperature was in the range of 1 to $5^{\circ}C$ and the average $2.5^{\circ}C$. The natural ventilation performance of the experimental greenhouse constructed in the reclaimed land almost satisfied the recommended ventilation rate in summer and the rise of indoor temperature relative to outdoor temperature did not deviate considerably from the cultivation environment of plants. Therefore, it was determined that the greenhouse cultivation in Saemangeum reclaimed land is possible with only natural ventilation systems without cooling facilities. As the reclaimed land is located in the seaside, the wind is stronger than the inland area, and the fog is frequent. This strong wind speed increases the ventilation rate of greenhouses, which is considered to be a factor for reducing the cooling load. In addition, since the fog duration is remarkably longer than that of inland area, the seasonal cooling load is expected to decrease, which is considered to be advantageous in terms of the operation cost of cooling facilities.

Evaluation of Water Stress Using Canopy Temperature and Crop Water Stress Index (CWSI) in Peach Trees (복숭아나무의 엽온 및 작물수분스트레스 지수를 이용한 수분스트레스 평가)

  • Yun, Seok Kyu;Kim, Sung Jong;Nam, Eun Young;Kwon, Jung Hyun;Do, Yun Soo;Song, Seung-Yeob;Kim, Minyoung;Choi, Yonghun;Kim, Ghiseok;Shin, Hyunsuk
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.20-27
    • /
    • 2020
  • The study was performed to calculate canopy temperatures and crop water stress index (CWSI) of 2-year-old 'Yumi' peach trees using thermal infrared imaging under different soil water conditions, and to evaluate availability for water stress determination. Canopy temperatures showed similar daily variations to air temperatures and they were higher during the daytime than air temperatures. Canopy temperatures for 24 h were correlated highly to air temperatures (r2 =0.95), solar radiations (r2 =0.74), and relative humidity (r2 =-0.88). In addition, soil water potential showed a highly negative correlation to canopy temperatures (r2 =-0.57), temperature differences between leaf and air (TD) (r2 =-0.71), and CWSI (r2 =-0.72) during the daytime (11 to 16 h). CWSI for 24 h was highly related to canopy temperatures (r2 =0.90) and TD (r2 =0.92), whereas CWSI was not correlated to soil water potential (r2 =-0.27) for 24 h but related highly to water potential (r2 =-0.72) during the daytime (11 to 16 h). Correlation coefficients between CWSI (y) and soil water potential (x) were highest from 11 to 12 h and a regression equation was deduced as y = -0.0087x + 0.14. CWSI was calculated as 0.575 at -50 kPa, which soil water stress generally occurs. Thus our result suggests that this regression equation using thermal infrared imaging is useful to evaluate soil water stress of peach trees.

Quality Characteristics of Sweet-pumpkin Paste with Different Thermal Condition and Sweet-Pumpkin Latte with Various Gums (가열 조건을 달리한 단호박 페이스트와 검 종류별 단호박 라떼의 품질특성)

  • Park, Bo-ram;Kim, Na-Jung;Yoo, Seon-Mi;Han, Gwi Jung;Kim, Ha Yoon;Han, Hye-min;Shin, Dong-Sun;Shin, Malshick
    • Korean journal of food and cookery science
    • /
    • v.31 no.3
    • /
    • pp.304-317
    • /
    • 2015
  • For the production of pumpkin paste with respect to heating conditions, we steamed the pumpkin for roughly 15 min, heated it with high pressure treatment for 0 min (A), 10 min (B), 20 min (C), 40 min (D), and subsequently investigated the quality characteristics. Generally a significant difference was observed between the pumpkin paste treated with and without high-pressure heat. The values of water content, crude protein and crude fiber of the high-pressure heat-treated groups B, C, D were decreased compared with untreated group A. The soluble fiber in experimental group B sweet-pumpkin paste treated with high-pressure heat for 20 min was higher than the control, and the highest value at 2.02. Experimental group D sweet-pumpkin paste treated with high-pressure heat for 40 min was found to have a decreased soluble fiber content relative to the control. The L value for the color of the group A untreated control sweet-pumpkin paste (no high-pressure heating) decreased as the time increased from 10 min to 40 min, with L values of 50.33, 49.46, and 48.06, respectively. The b value for the color of the sweet-pumpkin paste also decreased, showing a significant difference. Taking into account all the results, we chose experimental group B in order to prepare sweet-pumpkin latte. We used 0.2% gum (xanthan gum, locust bean gum, guar gum) as a stabilizer. Sweet-pumpkin latte with xanthan and locust bean gum has a suspension stability effect that lasts 90 min. The L and b values of sweet-pumpkin latte with gums increase and a value decrease compared with the control. In terms of the overall acceptance of the sweet-pumpkin latte, the experimental group with xanthan gum scored the best.

Study on Ventilation Efficiency of A Naturally Ventilated Broiler House-( I ) Summer Season (자연환기식 육계사내의 환기효율성 조사연구-( I )하절기)

  • 이인복;유병기;정문성;윤진하;전종길;김경원;성시흥
    • Journal of Animal Environmental Science
    • /
    • v.9 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • Most of broiler houses in Korea have the trouble of environmental control such as suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens. Accordingly, it is very urgent to develop optimum designs of naturally and mechanically ventilated broiler houses for Korean climate. In this study, the internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were measured at a naturally ventilated broiler house. The data were collected during summer season including local weather data. It was found that the difference between measured and optimum air temperatures was $14.0^{\circ}C$ in maximum during the summer time. The daily maximum range of internal averaged air temperature was found $10.5^{\circ}C$ while the uniformity was $5.2^{\circ}C$ in maximum. The maximum, average, and minimum internal averaged relative humidity were 89.3%, 73.7%, and 49.2%, respectively while locally measured were 95.1% and 47.2%, respectively in maximum and minimum. Considering Temperature-humidity index, during summer season, over 97% of totally rearing period was shown that counter plan is needed for thermal stress while it was very dangerous situation for 22% of the rearing period. The ammonia gas and dust concentrations were seriously affected by the broilers activity, growth level, and relative humidity.

  • PDF

Heat Budget Analysis of Light Thin Layer Green Roof Planted with Zoysia japonica (한국잔디식재 경량박층형 옥상녹화의 열수지 해석)

  • Kim, Se-Chang;Lee, Hyun-Jeong;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.190-197
    • /
    • 2012
  • The purpose of this study was to evaluate thermal environment and heat budget of light thin layer green roof through an experiment in order to quantify its heat budget. Two concrete model boxes($1.2m(W){\times}1.2m(D){\times}1.0m(H)$) were constructed: One experiment box with Zoysia japonica planted on substrate depth of 10cm and one control box without any plant. Between June 6th and 7th, 2012, outside climatic conditions(air temperature, relative humidity, wind direction, wind speed), evapotranspiration, surface and ceiling temperature, heat flux, and heat budget of the boxes were measured. Daily maximum temperature of those two days was $29.4^{\circ}C$ and $30^{\circ}C$, and daily evapotranspiration was $2,686.1g/m^2$ and $3,312.8g/m^2$, respectively. It was found that evapotranspiration increased as the quantity of solar radiation increased. A surface and ceiling temperature of those two boxes was compared when outside air temperature was the greatest. and control box showed a greater temperature in both cases. Thus it was found that green roof was effective in reducing temperature. As results of heat budget analysis, heat budget of a green roof showed a greater proportion of net radiation and latent heat while heat budget of the control box showed a greater proportion of sensible heat and conduction heat. The significance of this study was to analyze heat budget of green roof temperature reduction. As substrate depth and types, species and seasonal changes may have influences on temperature reduction of green roof, further study is necessary.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

A Study on the Characteristics of Condensable Fine Particles in Flue Gas (배출가스 중 응축성미세먼지 특성 연구)

  • Gong, Buju;Kim, Jonghyeon;Kim, Hyeri;Lee, Sangbo;Kim, Hyungchun;Jo, Jeonghwa;Kim, Jeonghun;Gang, Daeil;Park, Jeong Min;Hong, Jihyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.501-512
    • /
    • 2016
  • The study evaluated methods to measure condensable fine particles in flue gases and measured particulate matter by fuel and material to get precise concentrations and quantities. As a result of the method evaluation, it is required to improve test methods for measuring Condensable Particulate Matter (CPM) emitted after the conventional Filterable Particulate Matter (FPM) measurement process. Relative Standard Deviation (RSD) based on the evaluated analysis process showed that RSD percentages of FPM and CPM were around 27.0~139.5%. As errors in the process of CPM measurement and analysis can be caused while separating and dehydrating organic and inorganic materials from condensed liquid samples, transporting samples, and titrating ammonium hydroxide in the sample, it is required to comply with the exact test procedures. As for characteristics of FPM and CPM concentrations, CPM had about 1.6~63 times higher concentrations than FPM, and CPM caused huge increase in PM mass concentrations. Also, emission concentrations and quantities varied according to the characteristics of each fuel, the size of emitting facilities, operational conditions of emitters, etc. PM in the flue gases mostly consisted of CPM (61~99%), and the result of organic/inorganic component analysis revealed that organic dusts accounted for 30~88%. High-efficiency prevention facilities also had high concentrations of CPM due to large amounts of $NO_x$, and the more fuels, the more inorganic dusts. As a result of comparison between emission coefficients by fuel and the EPA AP-42, FPM had lower result values compared to that in the US materials, and CPM had higher values than FPM. For the emission coefficients of the total PM (FPM+CPM) by industry, that of thermal power stations (bituminous coal) was 71.64 g/ton, and cement manufacturing facility (blended fuels) 18.90 g/ton. In order to estimate emission quantities and coefficients proper to the circumstances of air pollutant-emitting facilities in Korea, measurement data need to be calculated in stages by facility condition according to the CPM measurement method in the study. About 80% of PM in flue gases are CPM, and a half of which are organic dusts that are mostly unknown yet. For effective management and control of PM in flue gases, it is necessary to identify the current conditions through quantitative and qualitative analysis of harmful organic substances, and have more interest in and conduct studies on unknown materials' measurements and behaviors.