• 제목/요약/키워드: Relative Rib Area

검색결과 26건 처리시간 0.023초

국내외 이형철근의 마디 형태 및 부착강도 비교 (Evaluation of Rib Geometries of Reinforcing Bars Available in Korea, Japan and USA)

  • 서동민;김기성;봉원용;양승열;홍기섭;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.278-281
    • /
    • 2006
  • The aims of this study are to investigate rib geometries of reinforcing bars commercially available in Korea, Japan and USA, and evaluate bond performance using beam-end test specimens. Measurement of rib geometries of the bars include nominal area, average distance of rib, height of rib and an angle of rib perpendicular to bar axis. The result of this study show that rib height of Korean reinforcement bars are much less than those of Japan and USA resulting in the lowest value of relative rib area. Average bond strength of Korean D25 deformed bars is known as 9 % less than that of bars produced in USA. Bond strength depends primarily on the relative rib area. Bond strength of the high relative rib area bars produced in USA show 18% higher than that of bars produced in Korea.

  • PDF

높은 마디 고강도 철근의 이음성능 (Splice Length of High Relative Rib Area Reinforcing Bars)

  • 오하나;홍건호;송기모;최동욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.116-119
    • /
    • 2004
  • The use of higher strength materials frequently requires the change of design provisions. Following to the previous researches, high strength reinforcing bars have a weak point about the development and splice length. Based on the previous research about high relative rib area, bond strength between reinforcing bars and concrete can be improved by the control of rib height and spacing. But, the code provisions do not include these specific shape of reinforcing bars. So, the purpose of this paper is to determine the effect of relative rib area to the bond strength. This paper describes the experiment and analysis of 5 beam-spliced specimens containing D25 with relative rib areas ranging from 0.073 to 0.17. The test results are also analyzed to make a design formula about the calculation of splice length on the consideration of relative rib area.

  • PDF

상대마디면적에 따른 이형철근의 겹침이음 강도 (Lap Splice Strength of Reinforcing Bars on the Relitive Rib Area)

  • 박성규;홍건호;최동욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.307-310
    • /
    • 2005
  • The effects of deformation properties on the bond of steel reinforcing bars to concrete are experimentally studies to expect the lap splice strength. Based on the previous research about relative rib area, lap splice strength between reinforcing bars and concrete can be improved by the control of rib height and spacing. This paper describes the testing and analysis of 15 beam-spliced specimens containing D25, D22, D19 with relative rib areas ranging from 0.066 to 0.162. The tests are analyzed to determine the effect of relative rib area(Rr) on the increase in bond strength. The tests also provide a preliminary indication of the effect of high relative rib area on the splice strength of uncoated bars.

  • PDF

반복하중시 철근의 마디형태에 따른 부착특성 (Bond Performance of Steel to Concrete subjected to Cyclic Loading)

  • 이재열;이웅세;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.545-550
    • /
    • 2000
  • Bond between reinforcing bars and the surrounding concrete is supposed to safely transfer load in the design process of reinforced concrete structures. Bar with high relative rib area will be studied further not only static load but also dynamic loading conditions to sustain better performance of bond for reinforced concrete structures under earthquake. To determine the bond behavior of high ribbed bars in beam and column joints under repeated loads, 31 pullout specimens were tested. Bond strength increases as relative rib area increases. Also the effect of relative rib area on bond is larger in cyclic loading than in monotonic loading.

  • PDF

하이브리드 FRP 보강근의 상대 리브면적에 따른 부착 특성 (Bond Characteristics of Hybrid Fiber Polymer Reinforcing bars with Different Relative Rib Area)

  • 박지선;유영찬;박영환;유영준;김형열;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.201-204
    • /
    • 2005
  • The bond characteristics of two types hybrid FRP (fiber reinforced polymer) reinforcing bars with different rib geometry were analyzed experimentally. Two types of hybrid FRP. reinforcing bars such as spiral and cross type with different relative rib area were considered in this test. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made according to the recommendations of CSA Standard S806-02. From the test results, it was found' that cross type hybrid FRP reinforcing bars showed the higher bond strength than that of spiral type's due to the higher relative rib area.

  • PDF

갈고리 시험체를 이용한 높은마디면적 철근의 정착성능 (Evaluate Anchorage Strength of High Relative Rib Area Bars Using Hook Test Specimens)

  • 서동민;홍기섭;최동욱;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.327-330
    • /
    • 2005
  • Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. However, the confinement force in practice has a limitation. Thus, the only variable is the bearing area corresponding to the change of bond force. In this study, to the evaluate anchorage strength of high relative rib area bars, hook bond test specimens are tested and the results are discussed. Higher rib height bars when bars are confined showed higher anchorage strength than lower rib higher bars.

  • PDF

철근 마디 형상에 따른 RC 휨부재의 부착강도 평가 (Bond Strength Evaluation of RC Beams on the Rib Shape of Reinforcing Bars)

  • 홍건호;김진아;최완철
    • 콘크리트학회논문집
    • /
    • 제23권3호
    • /
    • pp.393-400
    • /
    • 2011
  • 최근 구조물 설계개념의 변화로 사용응력 수준이 높아지고, 시공 및 경제성의 이유로 고강도 재료의 활용이 증가되고 있다. 그러나 고강도 철근을 사용하면 정착 및 이음 길이가 증가하게 되어 시공성이 저하되고 상세 설계의 어려움을 유발할 수 있다. 이에 따라 이 연구에서는 고강도 철근의 정착 및 이음 길이를 단축시키기 위하여 철근 마디형상의 변화가 부착 성능에 미치는 효과를 분석하도록 하였다. 기존 철근을 포함하여 마디의 형상을 개선한 총 5개의 단순보형 실험체를 제작하여 실험하였으며, 각 실험체는 경간 중앙부에서 겹침 이음되어 부착 파괴를 유도하도록 설계하였다. 실험의 결과는 부착강도, 하중-처짐 관계 및 균열의 관점에서 분석하였으며, 기존 연구자들의 부착강도 관련 설계 및 제안식과 비교 분석하였다. 실험 결과 마디면적비가 증가된 철근은 보통 철근보다 약 11%의 부착강도 향상을 나타내었으며, 마디면적비가 같더라도 높고 낮은 마디를 혼합한 경우에는 23%의 강도 증가를 나타내었다. 또한, 부재의 처짐, 균열의 개수 및 균열폭 등 사용성 관점에서 살펴볼 때, 개선된 형태의 철근은 보통 철근과 유사한 거동을 나타내어 현장적용에 큰 문제가 없을 것으로 분석되었다.

높은 마디면적 고강도 철근의 부착강도에 관한 실험적 연구 (An Experimental Study on Bond Strength of High-Strength Reinforcing Bars with High Relative Rib Area)

  • 홍건호;최동욱;최완철;홍기섭
    • 콘크리트학회논문집
    • /
    • 제17권3호
    • /
    • pp.375-384
    • /
    • 2005
  • 본 논문에서는 철근과 콘크리트 사이의 부착강도에 영향을 미치는 철근 마디의 효과를 실험적으로 연구하였다. 높은 마디면 적 철근에 관련된 기존 연구결과에 따르면, 철근과 콘크리트 사이의 부착강도는 철근 마디의 높이와 간격을 조정함으로써 향상시킬 수 있는 것으로 나타나고 있다. 그러나, 정착 및 이음길이 산정과 관련된 현행 국내 설계기준에서는 이러한 철근 마디모양의 효과를 반영하고 있지 못하다. 따라서, 본 연구에서는 철근의 상대마디면적이 부착강도에 미치는 영향을 분석하는 것을 목적으로 하였다. 본 논문에서는 크게 2 종류의 실험적 연구를 실시하였다. 철근의 직경과 상대마디면적(0.112${\~}$0.162)의 효과를 분석하기 위하여, 30개의 보단부형 부착시험체와 12개의 단순보형 겹침 이음 시험체에 대한 실험을 수행하였다. 각 실험의 결과는 변수의 일반화과정을 통하여 ACI 408 위원회의 제안식과 비교$\cdot$분석하였다. 본 연구의 실험결과, 철근과 콘크리트 사이의 부착강도는 철근의 직경과 상대마디면적에 비례하여 증가하는 것을 확인할 수 있었으며, 휨균열의 발생이나 부재의 파괴양상에는 상대마디면적의 효과가 거의 없는 것으로 분석되었다.

보 단부 부착시험체에 의한 높은마디 철근의 부착성능 (Evaluate Bond strength of high Relative Rib Area Bars Using Beam-end test specimens)

  • 서동민;양승열;홍기섭;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.112-115
    • /
    • 2004
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. However, the confinement force has a limitation. Thus, the only variable is the bearing angle corresponding to the change of bond force. Higher rib height bars possessing higher shearing resistance can maintain higher bearing angle and higher splitting resistance when bars are highly confined, and consequently higher bond strength, than lower rib higher bars. In this study, from the evaluate bond strength of high Relative Rib Area Bars Using beam-end test specimens are compared with the current provisions for development of reinforcement, and the improved design method of bond strength is proposed.

  • PDF

높은 마디면적비 철근의 부착강도에 따른 정착설계 연구 (Study on the Development Design Criteria of High Relative Rib Area bars)

  • 박성규;홍건호;최완철;홍기섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.270-273
    • /
    • 2006
  • Bond between reinforcing bar and the surrounding concrete is made up of three components. There are chemical adesion, friction, and mechanical interaction between the rib of the bar and the surrounding concrete. bond of deformed bars depends primarily on the beraing of rib deformation anainst the surrounding concrete. The final objective of the study is to enhance structural stability, and workability thorough increasing the bond strength between deformed bar and surrounding concrete. The results of this study will be used to shorten bond and development length by $20{\sim}30$ percent and it will facilitate to use of high strength and high-relative rib area bars.

  • PDF