• Title/Summary/Keyword: Relative Power Distribution

Search Result 166, Processing Time 0.035 seconds

Development of Sequential Sampling Plans for Tetranychus urticae in Strawberry Greenhouses (딸기 온실에서 점박이응애의 축차표본조사법 개발)

  • Choe, Hojeong;Kang, Juwan;Jung, Hyojin;Choi, Sira;Park, Jung-Joon
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.4
    • /
    • pp.427-436
    • /
    • 2017
  • A fixed-precision-level sampling plan was developed to establish control of the two-spotted spider mite, Tetranychus urticae, in two strawberry greenhouses (conventional plot, natural enemy plot). T. urticae was sampled by taking a three-leaflet leaf (1 stalk) from each plant (3 three-leaflet leaves) from each sampling position. Each leaflet was divided into three different units (1-leaflet, 2-leaflet, and 3-leaflet units) to compare relative net precision (RNP) values for selection of the appropriate sampling unit. The relative net precision values indicated that a 1-leaflet unit was more precise and cost-efficient than other units. The spatial distribution analysis was performed using Taylor's power law (TPL). Homogeneity of the TPL parameters in each greenhouse was evaluated by using the analysis of covariance (ANCOVA). A fixed-precision-level sequential sampling plan was developed using the parameters of TPL generated from the combined data of the conventional plot and natural enemy plot in a 1-leaflet sampling unit. Sequential classification sampling plans were also developed using the action threshold of 3 and 10 mites for pooled data. Using the results obtained in the independent data, simulated validation of the developed sampling plan by Resampling validation for sampling plan (RVSP) indicated a reasonable level of precision.

APPLICATION OF FFT-BASED ANALYSIS TO CONTACT CONDITION PREDICTION FOR TRIBOLOGICAL SURFACE DESIGN

  • Sung, I.H.;Lee, H.S.;Kim, D.E.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.255-256
    • /
    • 2002
  • In this paper, the frictional behavior according to the contact geometry was investigated using a micro-tribotester built inside a Scanning Electron Microscope (SEM) and an Atomic Force Microscope (AFM). FFT (Fast Fourier Transform) analysis for friction was conducted as a method to interpret the contact condition. From the experimental results, it could be concluded that the relative dimensions and distribution of contact asperities on the surface could be predicted by the power spectrum and main frequency in the FFT analysis of the friction signal.

  • PDF

Development of Preventive Diagnosis Techniques for Transformer Oil by Capacitive Sensor (전기용량형 센서를 이용한 변압기 절연유 열화진단용 예방진단기법 개발)

  • Kim, Ju-Han;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2061_2062
    • /
    • 2009
  • Within serviced period of time in transformer, thermal stress is the most influential parameter affecting the aging behavior of an insulation system. The thermal stress on the insulation system may occur from operation in a high temperature environment due to Joule's heat at winding coils. This paper describes a development of capacitive sensor and preventive diagnosis techniques for electrical insulating oil, widely used for power and distribution transformer. To survey the dielectric properties of the virgin and used mineral insulating oil, we utilized the highly precise measuring system of KRISS. And the results were used to determine the design factors of the sensor. To evaluate diagnosis by the sensor, we performed accelerated aging test about insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor.

  • PDF

Line-profile Formula in the Carbon Nanotubes by Electron Spin Resonance

  • Park, Jung-Il;Lee, Haeng-Ki
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.16 no.1
    • /
    • pp.11-21
    • /
    • 2012
  • The line-width of carbon nanotubes (CNTs) was studied as a function of the temperature at a frequency of 9.49 GHz in the presence of external electromagnetic radiation. The relative frequency dependence of the absorption power is obtained with the projection operator technique (POT) proposed by Kawabata. The line-width increased as the temperature increased in the high-temperature region (T>200 K). The scattering is little affected in the low-temperature region (T<200 K) because there is no correlation between the resonance field and the Fermi-Dirac distribution function. Thus, the present technique is considered to be more convenient to explain the resonant system as in the case of other optical transition problems.

The New Aging Diagnosis in IEC-60587 (IEC-60587의 새로운 열화진단)

  • Lim, Jang-Seob;Chung, Seung-Chun;Jeong, Jong-Cheol;Park, Gye-Choon;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05b
    • /
    • pp.71-74
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used In surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outside HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IIR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from IEC-60587 is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 according to applied time.

  • PDF

Evaluation of the Performance on WindPRO Prediction (WindPRO의 예측성능 평가)

  • O, Hyeon-Seok;Go, Gyeong-Nam;Heo, Jong-Cheol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.300-305
    • /
    • 2008
  • Using WindPRO that was software for windfarm design developed by EMD from Denmark, wind resources for the western Jeju island were analyzed, and the performance of WindPRO prediction was evaluated in detail. The Hansu site and the Yongdang site that were located in coastal region were selected, and wind data for one year at the two sites were analyzed using WindPRO. As a result, the relative error of the Prediction for annual energy Production and capacity factor was about ${\pm}20%$. For evaluating wind energy more accurately, it is necessary to obtain lots of wind data and real electric power production data from real windfarm.

  • PDF

EEG model by statistical mechanics of neocortical interaction

  • Park, J.M.;Whang, M.C.;Bae, B.H.;Kim, S.Y.;Kim, C.J.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.15-27
    • /
    • 1997
  • Brain potential is described using the mesocolumnar activity defined by averaged firings of excitatory and inhibitory neuron of neocortex. Lagrangian is constructed based on SMNI(Statistical Mechanics of Neocortical Interaction) and then Euler Lagrange equation is obtained. Excitatory neuron firing is assumed to be amplitude- modulated dominantly by the sum of two modes of frequency .omega. and 2 .omega. . Time series of this neuron firing is calculated numerically by Euler Lagrangian equation. I .omega. L related to low frequency distribution of power spectrum, I .omega. H hight frequency, and Sd(standard deviation) were introduced for the effective extraction of the dynamic property in the simulated brain potential. The relative behavior of I .omega. L, I .omega. H, and Sd was found by parameters .epsilon. and .gamma. related to nonlinearity and harmonics respectively. Experimental I .omega L, I .omega. H, and Sd were obtained from EEG of human in rest state and of canine in deep sleep state and were compared with theoretical ones.

  • PDF

Highly Accurate Approximate Multiplier using Heterogeneous Inexact 4-2 Compressors for Error-resilient Applications

  • Lee, Jaewoo;Kim, HyunJin
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.16 no.5
    • /
    • pp.233-240
    • /
    • 2021
  • We propose a novel, highly accurate approximate multiplier using different types of inexact 4-2 compressors. The importance of low hardware costs leads us to develop approximate multiplication for error-resilient applications. Several rules are developed when selecting a topology for designing the proposed multiplier. Our highly accurate multiplier design considers the different error characteristics of adopted compressors, which achieves a good error distribution, including a low relative error of 0.02% in the 8-bit multiplication. Our analysis shows that the proposed multiplier significantly reduces power consumption and area by 45% and 26%, compared with the exact multiplier. Notably, a trade-off relationship between error characteristics and hardware costs can be achieved when considering those of existing highly accurate approximate multipliers. In the image blending, edge detection and image sharpening applications, the proposed 8-bit approximate multiplier shows better performance in terms of image quality metrics compared with other highly accurate approximate multipliers.

Mass estimation of halo CMEs using synthetic CMEs based on a full ice-cream cone model

  • Na, Hyeonock;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.43.3-43.3
    • /
    • 2019
  • A coronal mass ejection (CME) mass is generally estimated by the total brightness measured from white-light coronagraph observations. The total brightness are determined from the integration of the Thomson scattering by free electrons of solar corona along the line of sight. It is difficult to estimate the masses of halo CMEs due to the projection effect. To solve this issue, we construct a synthetic halo CME with a power-law density distribution (ρ = ρ0r-3) based on a full ice-cream cone model using SOHO/LASCO C3 observations. Then we compute a conversion factor from observed CME mass to CME mass for each CME. The final CME mass is determined as their average value of several CME masses above 10 solar radii. Our preliminary analysis for six CMEs show that their CME mass are well determined within the mean absolute relative error in the range of 4 to 15 %.

  • PDF

A Investigation on the Actual Condition of PV Maintenance on Residental Buildings

  • Lee, Eung-Jik
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.53-58
    • /
    • 2014
  • Residental photovoltaic power system achieved remarkable results in distribution and activation through 'One Million Green Homes Program' led by the government. However, system maintenance and management after installation are relative unsatisfactory. Thus, problems, such as malfunctioning, decrease in efficiency, breakage, etc, are occurring in succession which means that expensive facilities are not used effectively. This study attempted to propose a more preferred alternative to the photovoltaic power system currently applied and installed to the housing by investigating and analyzing the said system, identifying management practices, and deriving problems. For this study, 48 houses equipped with photovoltaic systems in J City were chosen and they were analyzed after preliminary research and field investigation. The results revealed that most of the surveyed systems in J City are still in fairly good conditions. But the instruction and information regarding the appropriate operational management of those surveyed systems have not been delivered to the owner. Therefore, promotion education and related manual deployment should be done by the contractor. In terms of installation, inadequate system location and some warranty services are required to be improved, which are usually caused by a lack of careful planning and construction. In addition, the follow-up management needs to be provided about five years later after installation considering system deterioration.