• Title/Summary/Keyword: Rejection Ratio

Search Result 216, Processing Time 0.021 seconds

High Performance Millimeter-Wave Image Reject Low-Noise Amplifier Using Inter-stage Tunable Resonators

  • Kim, Jihoon;Kwon, Youngwoo
    • ETRI Journal
    • /
    • v.36 no.3
    • /
    • pp.510-513
    • /
    • 2014
  • A Q-band pHEMT image-rejection low-noise amplifier (IR-LNA) is presented using inter-stage tunable resonators. The inter-stage L-C resonators can maximize an image rejection by functioning as inter-stage matching circuits at an operating frequency ($F_{OP}$) and short circuits at an image frequency ($F_{IM}$). In addition, it also brings more wideband image rejection than conventional notch filters. Moreover, tunable varactors in L-C resonators not only compensate for the mismatch of an image frequency induced by the process variation or model error but can also change the image frequency according to a required RF frequency. The implemented pHEMT IR-LNA shows 54.3 dB maximum image rejection ratio (IRR). By changing the varactor bias, the image frequency shifts from 27 GHz to 37 GHz with over 40 dB IRR, a 19.1 dB to 17.6 dB peak gain, and 3.2 dB to 4.3 dB noise figure. To the best of the authors' knowledge, it shows the highest IRR and $F_{IM}/F_{OP}$ of the reported millimeter/quasi-millimeter wave IR-LNAs.

Design and implementation of planar UWB antenna with dual band rejection characteristics

  • Woon Geun Yang;Tae Hyeon Nam
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.109-115
    • /
    • 2023
  • In this paper, we design and implement an Ultra-Wide Band (UWB, 3.1~10.6 GHz) antenna with 5G mobile communication (3.42~3.70 GHz) and Wireless Local Area Network (WLAN, 5.15~5.825 GHz) bands rejection characteristics. The proposed antenna consists of a planar radiation patch with two slots. The upper slot contributes to reject 5G mobile communication band and the lower slot contributes to reject WLAN band. The Voltage Standing Wave Ratio (VSWR) values of the proposed antenna show good performances in whole UWB band except for rejection bands based on VSWR 2.0. The proposed UWB antenna was simulated using High Frequency Struture Simulator (HFSS) by Ansoft. The simulated antenna showed dual rejection bands of 3.31~3.92 GHz and 5.04~5.90 GHz in UWB band, and measured antenna showed dual rejection bands of 3.35~3.97 GHz and 5.06~5.97 GHz. The largest VSWR values measured at each rejection band are 13.60 at 3.64 GHz and 10.25 at 5.52 GHz. The measured maximum gain is 5.31 dBi at 10.00 GHz. The lowest gains for the measured antenna at rejection bands are -8.73 dBi at 3.70 GHz and -4.36 dBi at 5.56 GHz.

Image-rejection down-conversion mixer for bluetooth application using CMOS (CMOS를 이용한 Bluetooth용 이미지 제거 하향 주파수 변환기 설계)

  • 김대연;이진택;오승민;이상국
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.365-368
    • /
    • 2000
  • This paper describes image-rejection down conversion mixer for bluetooth application using 0.35u CMOS process. the proposed architecture is composed of LO phase shifter, mixer core, IF buffer, and IF phase shifter. IF phase shifter is designed using polyphase fillet. Simulation results show conversion gain = l0㏈, input 1㏈ compression point = -15.7㏈m. input third-order intercept point(IIP3) = -4.4㏈m, and image-rejection ratio = 37.8㏈, respectively, at 3V supply voltage, and 15.7㎃ current.

  • PDF

A Fast and Precise Blind I/Q Mismatch Compensation for Image Rejection in Direct-Conversion Receiver

  • Kim, Suna;Yoon, Dae-Young;Park, Hyung Chul;Yoon, Giwan;Lee, Sang-Gug
    • ETRI Journal
    • /
    • v.36 no.1
    • /
    • pp.12-21
    • /
    • 2014
  • In this paper, we propose a new digital blind in-phase/quadrature-phase (I/Q) mismatch compensation technique for image rejection in a direct-conversion receiver (DCR). The proposed image-rejection circuit adopts DC offset cancellation and a sign-sign least mean squares (LMS) algorithm with a unique step size adaptation both for a fast and precise I/Q mismatch estimation. In addition, several performance-optimizing design considerations related to accuracy, speed, and hardware simplicity are discussed. The implementation of the proposed circuit in an FPGA results in an image-rejection ratio (IRR) of 65 dB, which is the best performance with modulated signals, along with an adaptation time of 0.9 seconds, which is a tenfold increase in the compensation speed as compared to previously reported circuits. The proposed technique will be a promising solution in the area of image rejection to increase both the speed and accuracy of future DCRs.

The Degumming and Sericin Recovery of the Silk fabric Using the Electrolytic Water(II) (전해수를 이용한 견섬유 정련 및 세리신 회수(II)-분리막에 의한 세리신 농축을 중심으로-)

  • 배기서;이태상;노덕길;홍영기
    • Textile Coloration and Finishing
    • /
    • v.16 no.4
    • /
    • pp.10-18
    • /
    • 2004
  • In this work, Aqueous sericin solution was prepared by degumming process with electrolytic reduction water. Then, the microfiltration and ultrafiltration systems were applied to the concentration of aqueous sericin solution. The objective of this study was to select the optimum operating condition among the different pressure. The permeate flux and rejection ratio were observed with time, pressure, flow rate and concentration. and, the wastewater and permeated water quality values such as pH, BOD, COD, and NH levels were measured. In order to see the influence of electrolytic reduction water, the flux of pure water and electrolytic reduction water by PVDF22(MF) and PS100(UF) membrane was measured. In microfiltration system, the relative flux reduction decreased rapidly to 0.02 in the 30min, as the concentration polarization and gel layer formation were increased. and then the sericin concentration rejection ratio was 40%. In ultrafiltration system, the permeate flux decreased with time and concentration, and increased with the operating pressure and flow rate. Optimal condition in PS100 membrane system for sericin concentration was operating pressure 1.464kgf/$cm^24, operating flow rate $7\ell/min at\; 40^{\circ}C$. At that time, sericin concentration rejection ratio was 83% respectably. The sericin solution was concentrated from 0.1wt% solution to 0.2 wt % solution during about 2 hrs by the UF filteration membrane system.

Interference Analysis Between Fixed Wireless System and Radar Operating in VHF/UHF Bands with Geographic Information (지리정보에 기반한 VHF/UHF 대역의 고정무선시스템과 레이더 간의 간섭분석)

  • Suh, Kyoung-Whoan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.40-47
    • /
    • 2013
  • By virtue of Rec. ITU-R P.1546 and geography information system, interference analysis for the fixed wireless system and radar has been presented based upon the frequency-distance rules with minimum coupling loss, and a comprehensive methodology for assessing interoperability between systems was examined in terms of received signal, protection ratio, frequency dependent rejection. Also to find the antenna gain from a discrimination angle, a useful S-I plane was introduced based on signal and interference vectors derived from the real map with geographic information. To show some computational results, geography information on the map was taken for the given area, and field strength and path profile were illustrated for the radar and fixed wireless system operating at 2.7 GHz, for convenience. In addition the interference effect of receiver was also checked as a function of radar beam direction including protection ratio and frequency dependent rejection. The developed interference analysis can be actually applied to evaluate interoperability for wireless systems in the VHF and UHF bands.

Nuclear Medicine Methods of Rejection Diagnosis in Transplanted Rat Model (심장 이식된 백서에서의 거부반응 진단의 핵의학적 방법)

  • Chung, Won-Sang;Kim, Sang-Heon;Kim, Hyuck;Kim, Young-Hak;Kang, Jung-Ho;Choi, Yun-Young;Lee, Chul-Beom
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.379-383
    • /
    • 2003
  • Background: An accurate diagnosis of the severity of the rejection after a heart transplantation relies on endomyo-cardial biopsy, but because of its invasiveness and the need for repeated examination makes it is an inappropriate monitoring method. Therefore, we have tried to find a monitoring method that is continuous and less invasive. Material and Method: Heterotopic heart transplantation using Ono-Lindsey Method was done in 20 rats, and then $^{99m}$ Tc-Pyrophosphate (PYP) scan was done after a month, Uptake ratio of transplanted heart to vertebrae (H/V) was obtained to be compared with the biopsy result. Result: Rejection was defined when the H/V uptake ratio was higher than 0.09, and we compared the uptake ratio with the results of biopsy. The result was true positives was 3, true negatives 12, false negatives 2, andfalse positives 3. Therefore sensitivity was 60% and specificity was 80%, diagnostic value was 75%. Conclusion: $^{99m}$Tc-Pyrophosphate (PYP) scan was a useful method for the evaluation of the heart transplantation rejection and it will be helpful for monitoring rejection as an non-invasive and simple method.hod.

Design and Implementation of UWB Antenna with Band Rejection Characteristics (대역저지 특성을 갖는 초광대역 안테나 설계 및 구현)

  • Yang, Woon Geun;Nam, Tae Hyeon;Yu, Jae Seong;Oh, Hee Oun
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.1
    • /
    • pp.31-36
    • /
    • 2018
  • In this paper, we designed and implemented an ultra wideband(UWB) antenna with band rejection characteristics. The proposed antenna consists of a planar radiation patch with slots and ground planes on both sides. Due to the slots in the radiation patch, the antenna shows band rejection characteristics. U-type slot contributes for wireless local area network(WLAN, 5.15~5.825 GHz) band rejection and n-type slot contributes for X-Band(7.25~8.395 GHz) band rejection. To make voltage standing wave ratio(VSWR) less than 2.0 for UWB frequency band except rejection bands, the shapes of planar radiation patch and ground plane was modified. The Ansoft 's high frequency structure simulator(HFSS) was used for the design process and simulations of the proposed antenna. The simulated antenna showed VSWR less than 2.0 for all UWB band excepts for dual rejection bands of 5.15 ~ 5.94 GHz and 7.02 ~ 8.45 GHz. And measured VSWR for the implemented antenna is less than 2.0 for all UWB band of 3.10~10.60 GHz excluding dual rejection bands of 5.12~5.95 GHz and 7.20~8.58 GHz.

Design and Implementation of UWB Antenna with 5G Mobile Communication and WLAN Bands Rejection Characteristics (5세대 이동통신 및 WLAN 대역저지 특성을 갖는 UWB 안테나 설계 및 구현)

  • Yang, Woon Geun;Nam, Tae Hyeon
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.4
    • /
    • pp.336-341
    • /
    • 2018
  • In this paper, we designed and implemented an ultra wideband (UWB) antenna with 5G mobile communication and WLAN bands rejection characteristics. The proposed antenna consists of a planar radiation patch with two slots, parasitic elements on both sides of the strip line and ground plane on back side. The upper n-type slot contributes for 5G mobile communication band (3.42~3.70 GHz) rejection and the lower n-type slot contributes for wireless local area network (WLAN) band (5.15~5.825 GHz) rejection. Parasitic elements were used in order to satisfy the voltage standing wave ratio (VSWR) less than or equal to 2.0 for UWB band (3.10~10.60 GHz) except two rejection bands. The Ansoft's high frequency structure simulator (HFSS) was used for antenna design and simulations. The simulated antenna showed dual rejection bands of 3.36~3.71 GHz and 5.13 ~ 5.92 GHz in UWB band, and measured result for the implemented antenna showed dual rejection bands of 3.40~3.72 GHz and 5.08~5.858 GHz. Simulated and measured VSWRs are less than or equal to 2.0 for all UWB band except dual rejection bands.

Rejection Characteristics of Various Heavy Metals by Low-pressure Nanofiltration (저압나노여과에 의한 각종 중금속의 제거 특성)

  • Oh, Jeong-Ik;Kim, Han-Seung;Kim, Chung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.493-499
    • /
    • 2004
  • Rejection characteristics of heavy metals by nanofiltration membranes were investigated. Nanofiltration membranes rejected heavy metals much better than chloride, sulfate and TOC, of which concentration in synthetic wastewater was higher than that of heavy metals. To consider rejection characteristics of various metals by nanofiltration membranes, separation coefficient, which is the ratio of the metal permeation rate to the chloride ion or TOC permeation rate, was introduced. In spite of different materials and different nominal salt rejection of nanofiltration membrane used, the separation coefficients of metals were nearly the same. In particular, the separation coefficient of arsenic against chloride ion and TOC was larger than any other separation coefficient of heavy metals. These phenomena were observed in the relationship between the molar conductivity and the separation coefficient for heavy metals.