• Title/Summary/Keyword: Reinforcing material

Search Result 540, Processing Time 0.026 seconds

A Study on the Improvement of Reinforcing Bar Detailing (국내 철근공사 배근상세 개선방안에 관한 연구)

  • Park, U-Yeol;Kim, Baek-Jung;Jung, Hyun-Ok;Yun, Seok-Heon;Cho, Hun-Hee;Kang, Kyung-In
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.1
    • /
    • pp.83-90
    • /
    • 2008
  • The reinforcing steel process is composed of the development of placing drawing, cutting and bending, and the placement and fabrication of the reinforcement, and is participated in by reinforcement detailer, the fabricator and placer. Because the reinforcing steel process-from estimating and rebar detailing, to production, material tracking, billing, and general accounting-is conducted by many participant, reinforcement details based on building code and reinforcing bar detailing standards are essential. The process, however, holds some problems. Building code has been revised recently, and the utilization of placing drawings was proved to be low, and the reinforcement estimating in early stage of the process is below what is required for placement. Therefore, in this study, a survey was conducted to the reinforcement detailer, the fabricator and placer of domestic construction industry. According to the analysis of the survey, the reinforcement details on site was not standardized. The improvement in reinforcing steel detailing standards was sought by analyzing the results of the survey including reinforcement constructability.

Effects of Graphite Shape and Composite Fabricating Method on Mechanical Properties of Graphite/Copper Composites (그라파이트/구리 복합재료의 기계적 특성에 미치는 그라파이트 형상과 복합재료 제조방법의 영향)

  • Sohn, Youhan;Han, Jun Hyun
    • Korean Journal of Materials Research
    • /
    • v.28 no.10
    • /
    • pp.601-609
    • /
    • 2018
  • To study the effects of graphite shape and the composite fabricating method on the mechanical properties of graphite/copper (Gr/Cu) composites, a copper composite using graphite flakes or graphite granules as reinforcing phases is fabricated using mechanical mixing or electroless plating method. The mechanical properties of the Gr/Cu composites are evaluated by compression tests, and the compressive strength and elongation of the Gr/Cu composites using graphite granules as a reinforcing phase are compared with those of Cu composites with graphite flakes as a reinforcing phase. The compressive yield strength or maximum strength of the Gr/Cu composites with graphite granules as a reinforcing phase is higher than that of the composites using graphite flakes as a reinforcing phase regardless of the alignment of graphite. The strength of the composite produced by the electroless plating method is higher than that of the composite material produced by the conventional mechanical mixing method regardless of the shape of the graphite. Using graphite granules as a reinforcing phase instead of graphite flakes improves the strength and elongation of the Gr/Cu composites in all directions, and reduces the difference in strength or elongation according to the direction.

Reinforcing Effect of Waste Tires As Reinforcement Material (지반보강재로서 폐타이어의 보강 효과)

  • 윤여원;최경순;천성한
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.827-832
    • /
    • 2003
  • This study presented the reinforcing effect of sands by using newly devised 3D Tirecell. Plate loading tests for sand were conducted for different relative density and number of reinforced layers. From the tests, the ultimate bearing capacity of reinforced sand increased with increasing relative densities. The effect of reinforced layers with 0.4B interval is limited to 2 layers and further reinforcing effects can not be obtained beyond 3 layers. Especially the bearing capacity increased remarkably at 1 layer of Tirecell reinforcement and the degree of increase was small for 1 layer to 2 layers increase of reinforcement. Test results show that the reinforcing effect of Tirecell is prominent compared with commercial geocell in the literature.

  • PDF

Repid Corrosion Test on Reinforcing Steels in Chloride-Penetrating Concrete Structures with Various Crack Patterns (균열특성에 따른 콘크리트 구조물의 염분침투에 관한 실험적 연구)

  • 이상국;정영수;문홍식;안태송;유환구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.345-350
    • /
    • 2001
  • Reinforced concrete is, in general, known as a high durability material due to a strong alkalinity of cement. Probable concrete cracks could incur steel corrosion of RC structures and then could easily deteriorate the concrete durability, which can be fully secured by a systematic quality control for the construction of concrete structures. For the corrosion protection of reinforcing steels in concrete, however, current design specifications of concrete cover depth do not in-depth consider the effect of the cracks as well as the chloride content of RC structures. Therefore, appropriate provisions for concrete cover depth should be coded by considering the influence of concrete cracks on the corrosion of reinforcing steels. The objective of this research is to investigate pertinent cover depth, which can prohibit rebar corrosion, on the basis of experimental corrosion measurements of reinforcing steels on crack characteristics such as the width, depth and frequency of concrete cracks.

  • PDF

The Effect of Corrosion Protection of Reinforcing Steel in Concrete Applied Surface Painting Materials (내염성도장 콘크리트 주에 묻은 철근의 방청효과)

  • 문한영;김성수;김홍삼;김홍삼
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.196-200
    • /
    • 1996
  • In the case of construction under the marine environment the durability of concrete structures is everely deteriorated by the penetration of salts which results in the corrosion of reinforcing steel. To verify the effect of corrosion protection of reinforcing steel by isolating the penetration of chlorideion this study investigated the bond strength between painting material and concrete, the degree of the penetration-diffusion of chloride ion and the accelerated corrosion test using different potential. Results show that the painted concrete has little the penetration-diffusion of cholride and the reinforcing steel in painted concrete is little corroding.

  • PDF

Seismic Retrofit of School Facilities Using Rapping and Attaching Composite Material (부착 및 래핑형 복합소재를 이용한 학교시설의 내진보강)

  • Park, Choon-Wook;Kim, Dong-Hwi;Kwon, Min-Ho;Choi, Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.2
    • /
    • pp.135-142
    • /
    • 2014
  • In paper after the strong earthquake of recently the Korea neighborhood, the Korean government survey show that the 86% of school buildings in Korea are in potential damage risk and only 14% of them are designed as earthquake-resistance buildings. Earthquake Reinforcing projects of school have been a leading by the ministry of education, however their reinforcing methods done by not proved a engineering by experiment which results in uneconomical and uneffective rehabilitation for the future earthquake. An experimental and analytical study have been conducted for the shear reinforcing method of RC beam by axis and horizontal axis load using attaching composite beam. Based on the previous research, in this study, design examples are given to show the performance evaluation for the column reinforcing of old school buildings using nonlinear analysis is going to be conducted and strengthening method is going to be on the market after their performance is proved by the test.

Study of Development on Mechanical Connection of Reinforcing Bars (With Study of Tensile Force) (철근 커플러 개발에 관한 연구 (인장력 시험을 중심으로))

  • 최희복;김광희;강경인
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.11a
    • /
    • pp.37-41
    • /
    • 2002
  • Lap splice is used in building construction up to recently. As buildings become higher and larger, the use of high tensile bar is increasing due to increasing in the use of high compression concrete. However the using of high tensile bar in lap splice causes eccentricity and difficulty in placing of concrete inside the form, therefore not allowing enough intervening material. Various mechanical connection are being developed but the coupler of today needs either a secondary intervening material or secondary processing that consumes much time. Therefore a coupler, needing neither a secondary intervening material nor secondary processing, was made in this study which lead to following results. (1) Breaking occurred in all experimented rebar. (2) Acquirement of tension exceeding the standard requirement. (3) Acquirement of elongation percentage within the standard requirement.

  • PDF

Elliptic Integral Solutions of Large Deflection of Reinforcing Fiber Elastica with Circular Wavy Pattern

  • Jung, Jae-Ho;Lee, Kyung-Woo;Kang, Tae-Jin
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.163-169
    • /
    • 2001
  • The solution of two-dimensional deflection of circular wavy reinforcing fiber elastics was obtained for one end clamped boundary under concentrated load condition. The fiber was regarded as a linear elastic material. Wavy shape was described as a combination of half-circular arc smoothly connected each other with constant curvature of all the same magnitude and alternative sign. Also load direction was taken into account. As a result, the solution was expressed in terms of a series of elliptic integrals. These elliptic integrals had two different transformed parameters involved with load value and initial radius of curvature. While we found the exact solutions and expressed them in terms of elliptic integrals, the recursive ignition formulae about the displacement and arc length at each segment of circular section were obtained. Algorithm of determining unknown parameters was established and the profile curve of deflected beam was shown in comparison with initial shape.

  • PDF

A Effects of applying the noise reduction method between existing buildings (기존 건축물 층간소음 저감공법 적용 효과 분석)

  • Song, Tae-Hyeob;Jeon, Chan-Soo;Kim, Ji-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.249-250
    • /
    • 2018
  • To control the floor noise generated in the apartment building, a method of reinforcing the floor at the floor is applied. However, since existing buildings are difficult to reinforce upper generations, the ceilings of lower generations should be reinforced. The purpose of this study is to analyze the reduction effect by measuring the impact noise after reinforcing the floor soundproofing material on the ceiling of the existing building. In order to ensure the economical efficiency and flame retardancy of the products used as building interior materials, the existing polyurethane foam was impregnated with mineral to prepare test specimens and attached to the concrete slab surface. As a result, it was shown that heavy impact sound can reduce 2dB~5dB and light impact sound can reduce 4~8dB.

  • PDF

Study on plain concrete crack reduction characteristics by fiber type (섬유보강재 종류에 따른 무근콘크리트 균열저감 특성에 관한 연구)

  • Lee, Ji-Hwan;Yun, Chang-Yeon;Park, Gi-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.178-179
    • /
    • 2022
  • This study evaluated the crack reduction characteristics of concrete by type of fiber reinforced concrete. As a result of the experiment, it was shown that the fluidity decreased due to the mixing of the fiber reinforcing material. The higher the amount of fiber reinforced material used, the higher the decrease in fluidity. It was confirmed that the tensile strength was improved by the mixing of the fiber reinforcing material. The selection of fiber reinforcement has a great influence on the crack reduction effect.

  • PDF