• 제목/요약/키워드: Reinforced Concrete Deep Beam

검색결과 85건 처리시간 0.022초

탄소섬유시트로 보강된 춤이 큰 철근콘크리트 보의 전단파괴거동(剪斷破壞擧動) (Shear Failure Behaviour of Reinforced Concrete Deep Beam Strengthened by Carbon Fiber Sheets)

  • 조수제;손성현;박성수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권4호
    • /
    • pp.145-153
    • /
    • 1999
  • The major objective of this study is to investigate experimentally the shear strengthening effect of carbon fiber sheets upon reinforced concrete deep beam and shear failure behavior variation of reinforced concrete deep beam strengthened by carbon fiber sheets. Tests are carried out with 6 specimens were shear failure at first loading tests, and with parameters including the types of shear strengthening of carbon fiber sheets (I type, S type, U type), and plies of sheets (2 ply and 1 ply). From the results of test, analyzed load-deflection of midspan, strain variation of main bars and transverse reinforcement, maximum load capacity of strengthened specimens, and compared with the previous test results.

  • PDF

강섬유보강(鋼纖維補强)콘크리트 Deep Beam의 전단특성(剪斷特性)에 관한 연구(硏究) (A Study on the Shear Properties of Steel Fiber Reinforced Concrete Deep Beams)

  • 문제길;홍익표
    • 대한토목학회논문집
    • /
    • 제13권1호
    • /
    • pp.75-87
    • /
    • 1993
  • 본 논문은 강섬유보강콘크리트 deep beam의 전단특성을 규명하고 균열전단강도와 극한전단강도를 예측하기 위한 것으로 섬유로 보강된 16개의 보를 포함한 총 20개의 보를 4 series로 나누어 실험을 수행하였다. 실험의 변수는 콘크리트의 강도, 섬유혼입률, 전단지간 등이며, 실험 과정을 통해 파괴형상, 처짐, 변형률, 전단강도 등을 측정 하였다. 실험결과로 부터 섬유의 혼입량이 많아지고, 콘크리트의 강도가 커질 수록, 그리고 전단지간이 짧아질수록 섬유보강콘크리트 deep beam의 균열 및 극한전단강도가 증가됨을 밝혔다. 또한, 실험성과를 회귀분석하여 균열전단강도와 극한전단강도 추정식을 제안 하였다. 제안된 추정식에 의한 계산값과 실험성과를 비교 검토하여 그 상관성을 확인하였다.

  • PDF

변단면 깊은 보의 전단설계 (Shear Design of Deep Beam with Variable Depth)

  • 최정호;김태완;이승훈;엄장섭;진치섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.377-380
    • /
    • 2004
  • Reinforced concrete deep beams are commonly used in many structural applications, including transfer girders. pile caps, foundation walls. and offshore structures. In this paper. the shear behavior and reinforcement effects of simply supported reinforced concrete deep beam with variable depth subject to concentrated loads have been scrutinized using strut-and-tie model to verify the effects of variable depth. The analysis results show that strut-and-tie Model of ACI 318-02 code is very effective method to design of simply supported reinforced concrete deep beam with variable depth.

  • PDF

철근콘크리트 보의 강도해석을 위한 격자 연화 스트럿-타이 모델(GS-STM) 방법 (GS-STM Approach for Ultimate Strength Analysis of Reinforced[ Concrete Beams)

  • 박정웅;윤영묵
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.451-456
    • /
    • 2003
  • The behavior of concrete deep beams in shear is substantially influenced by beam size and shape, loading conditions, reinforcement details, and material properties. Therefore, it is not easy to predict the ultimate response of beams correctly and take into account all those factors in practical shear design. In this study, a grid softened strut-tie model approach for determining the shear strengths of various reinforced concrete deep beams is proposed. The validity of the approach is examined through the strength analysis of numerous reinforced concrete deep beams tested to failure. The approach can be further developed to improve the current deep beam design procedures by incorporating the actual shear resisting mechanisms of deep beams.

  • PDF

철근 콘크리트 깊은보의 전단 거동에 대한 개구부의 영향 (The effect of opening on the shear behavior of reinforced concrete deep beam)

  • 정원태;양근혁;이영호;은희창;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.335-340
    • /
    • 2002
  • The focus of this experimental study is to verify the effect of openings in reinforced concrete deep beam. Main variables are opening depth, width and vertical locations but the shear span-to-overall depth ratio was fixed by 0.5. The experimental results about 8 deep beams which was tested under two equal symmetrically placed point loads are reported.

  • PDF

Energy absorption of reinforced concrete deep beams strengthened with CFRP sheet

  • Panjehpour, Mohammad;Abang Ali, Abang Abdullah;Aznieta, Farah Nora
    • Steel and Composite Structures
    • /
    • 제16권5호
    • /
    • pp.481-489
    • /
    • 2014
  • The function of carbon fibre reinforced polymer (CFRP) reinforcement in increasing the ductility of reinforced concrete (RC) deep beam is important in such shear-sensitive RC member. This paper aims to investigate the effect of CFRP-strengthening on the energy absorption of RC deep beams. Six ordinary RC deep beams and six CFRP-strengthened RC deep beams with shear span to the effective depth ratio of 0.75, 1.00, 1.25, 1.50, 1.75, and 2.00 were tested till failure in this research. An empirical relationship was established to obtain the energy absorption of CFRP-strengthened RC deep beams. The shear span to the effective depth ratio and growth of energy absorption of CFRP-strengthened deep beam were the significant factors to establish this relationship.

Nonlinear behavior of deep reinforced concrete coupling beams

  • Zhao, Z.Z.;Kwan, A.K.H.
    • Structural Engineering and Mechanics
    • /
    • 제15권2호
    • /
    • pp.181-198
    • /
    • 2003
  • Six large scale models of conventionally reinforced concrete coupling beams with span/depth ratios ranging from 1.17 to 2.00 were tested under monotonically applied shear loads to study their nonlinear behavior using a newly developed test method that maintained equal rotations at the two ends of the coupling beam specimen and allowed for local deformations at the beam-wall joints. By conducting the tests under displacement control, the post-peak behavior and complete load-deflection curves of the coupling beams were obtained for investigation. It was found that after the appearance of flexural and shear cracks, a deep coupling beam would gradually transform itself from an ordinary beam to a truss composed of diagonal concrete struts and longitudinal and transverse steel reinforcement bars. Moreover, in a deep coupling beam, the local deformations at the beam-wall joints could contribute significantly (up to the order of 50%) to the total deflection of the coupling beam, especially at the post-peak stage. Finally, although a coupling beam failing in shear would have a relatively low ductility ratio of only 5 or even lower, a coupling beam failing in flexure could have a relatively high ductility ratio of 10 or higher.

FRP Bar로 보강된 콘크리트 깊은보의 전단강도에 관한 실험적 연구 (Experimental Study on Shear Strength of Concrete Deep Beam Reinforced FRP Bars)

  • 조장세;김민숙;이영학;김희철
    • 한국전산구조공학회논문집
    • /
    • 제24권1호
    • /
    • pp.23-31
    • /
    • 2011
  • 본 연구는 섬유 보강 폴리머(Fiber Reinforced Polymers, 이하 FRP) bar로 보강된 콘크리트 깊은보의 전단강도을 평가하기 위하여 전단경간비, 보강비, 유효깊이, 주근의 종류를 변수로 총 15개의 시험체에 대한 전단 실험을 수행하였다. 전단 실험을 토대로 FRP bar로 보강된 콘크리트 깊은보의 균열 및 처짐에 대한 거동 조사를 수행하였으며, ACI 318-08의 스트럿-타이 모델(이하 STM)을 이용한 전단강도와 아치작용을 고려한 기존 제안식에 의한 전단강도를 비교 평가하였다. 그 결과 FRP bar로 보강한 경우가 Steel bar로 보강한 경우보다 전단강도가 증가하는 것으로 나타났으며, 전단강도 산정에 있어 ACI 318-08 STM을 이용한 방법이 경험식에 의한 방법보다 상대적으로 정확했다.

RC deep beams with unconventional geometries: Experimental and numerical analyses

  • Vieira, Agno Alves;Melo, Guilherme Sales S.A.;Miranda, Antonio C.O.
    • Computers and Concrete
    • /
    • 제26권4호
    • /
    • pp.351-365
    • /
    • 2020
  • This work presents numerical and experimental analyses of the behavior of reinforced-concrete deep beams with unconventional geometries. The main goal here is to experimentally and numerically study these geometries to find possible new behaviors due to the material nonlinearity of reinforced concrete with complex geometries. Usually, unconventional geometries result from innovative designs; in general, studies of reinforced concrete structures are performed only on conventional members such as beams, columns, and labs. To achieve the goal, four reinforced-concrete deep beams with geometries not addressed in the literature were tested. The models were numerically analyzed with the Adaptive Micro Truss Model (AMTM), which is the proposed method, to address new geometries. This work also studied the main parameters of the constitutive model of concrete based on a statistical analysis of the finite element (FE) results. To estimate the ultimate loads, FE simulations were performed using the Monte Carlo method. Based on the obtained ultimate loads, a probabilistic distribution was created, and the final ultimate loads were computed.

Shear strength of steel fiber reinforced concrete deep beams without stirrups

  • Birincioglu, Mustafa I.;Keskin, Riza S.O.;Arslan, Guray
    • Advances in concrete construction
    • /
    • 제13권1호
    • /
    • pp.1-10
    • /
    • 2022
  • Concrete is a brittle material and weak in tension. Traditionally, web reinforcement in the form of vertical stirrups is used in reinforced concrete (RC) beams to take care of principal stresses that may cause failure when they are subjected to shear stresses. In recent decades, the potential of various types of fibers for improving post-cracking behavior of RC beams and replacing stirrups completely or partially have been studied. It has been shown that the use of steel fibers randomly dispersed and oriented in concrete has a significant potential for enhancing mechanical properties of RC beams. However, the studies on deep steel fiber reinforced concrete (SFRC) beams are limited when compared to those focusing on slender beams. An experimental program consisting of three RC and nine SFRC deep beams without stirrups were conducted in this study. Besides, various models developed for predicting the ultimate shear strength and diagonal cracking strength of SFRC deep beams without stirrups were applied to experimental data obtained from the literature and this study.