• Title/Summary/Keyword: Rehabilitation Treatment

Search Result 3,440, Processing Time 0.026 seconds

Removal Torque of Mg-ion Implanted Clinical Implants with Plasma Source Ion Implantation Method (마그네슘 이온주입 임플란트의 뒤틀림 제거력에 관한 연구)

  • Kim, Bo-Hyoun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.41-52
    • /
    • 2009
  • The surface treatment of titanium implant could bring out the biochemical bonding between bone and implant. The purpose of this study was to evaluate the biomechanical bone response of Mg-ion implanted implants with plasma source ion implantation method. Twelve New Zealand white rabbits were included in this study. Each rabbit received one control fixture (blasted with resorbable blasting media, RBM) and three types of Mg ion implanted fixtures in tibiae. The implants were left in place for 6 weeks before the rabbits were sacrificed. Removal torque value and resonance frequency analysis (ISQ) were compared. The repeated measured analysis of variance was used with $P{\leq}0.05$ as level of statistical significance. ISQ was not different among all groups. However, the ISQ was increased after 6 weeks healing. The group had lowest ISQ value showed the greatest increment. Mg-1 implants with 9.4% retained ion dose showed significantly higher removal torque value than that of the other implants. From this results, it is concluded that the Mg-1 implants has stronger bone response than control RBM surface implant.

Influence of the Dental Implant Abutment Screw Coating Materials on Joint Stability (임플란트 지대주나사 코팅이 결합안정성에 미치는 영향)

  • Lim, Hyun-Pil;Park, Young-Sun;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Yoon, Suk-ja
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.157-169
    • /
    • 2009
  • The aim of this study was to evaluate effect of implant abutment screw coating treatment on joint stability, investigating mechanical properties of these. For this study used $ExFeel^{(R)}$ external hexed implant system and $15mm{\times}1mm$ discs. Experimental group was $1{\mu}m$ TiN, TiCN, TiC coated abutment screws and discs. To know mechanical property, i evaluated adhesion strength, surface hardness, using disc, corrosion test using screw. The results were as follows : rotation angle of coated screws increased than that of non-coated screw because of lower friction coefficient, especially TiC coated screw group had the largest value, but removal torque decreased in all coated screws (p<0.05). Torque loss before and after fatigue test was the smallest in TiC-coated screws, and the largest in non-coated screws (p<0.05), and there was no statistically significant difference between dry condition and wet condition of screws because of higher surface hardness and lower friction coefficient. From the above results, TiN, TiCN, TiC coating group had high abrasion resistance, especially TiC coated group which had low torque-consuming, high rotation angle as low friction coefficient will be considered to influence on implant abutment screw joint stability positively.

3-dimensional finite element analysis of maxillary molar distalization using R-jig with TADs (TADs와 R-jig를 이용한 상악 구치 원심 이동에 관한 3차원 유한요소 분석)

  • Tark, Myung-Hyun;Lee, Keunyoung;Cho, Jin-Woo;Chee, Young-Deok;Cho, Jin-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.265-277
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the differences of displacement pattern depending on type of sliding jig and application method during maxillary molar distalization with temporary anchorage devices (TADs). Materials and Methods: Maxilla with normal tooth size and arch shape was selected to create a 3-dimensional finite element model, which included the bracket, orthodontic main archwire, removable sliding jig (R-jig). The orthodontic mini-implant anchorage was set 8 mm superiorly from main archwire, buccally between the second premolar and first molar. The base experimental design was Condition 1, which was composed $0.019{\times}0.025$ inch stainless steel (SS) of wire size of R-jig, 200 gm force, un-tied state. And the other designs varied to wire size of R-jig, magnitude of force. The results are as follows. Results: As the wire size of R-jig was increased, the deformation of R-jig was decreased. However, the displacement of second molar wasn't different each other. As the force to second molar was increased, the more displacement of second molar was observed, and the more distal tipping movement, vetical displacement was observed. Conclusion: R-jig can get distal teeth movement in orthodontic treatment without side effects.

A Systematic Review on Effects of School-Based Occupational Therapy (학교기반 작업치료에 관한 체계적 고찰)

  • Jung, Nam-Hae
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.12 no.1
    • /
    • pp.25-38
    • /
    • 2014
  • Objective : This study was conducted to determine effects of school-based occupational therapy through a systematic review Methods : We systematically reviewed studies published in PubMed and Ovid from 2000 to June 2014 using keyword 'school' or 'children' and 'occupational therapy'. Fourteen studies were selected. The level of evidence, participants, assessment, intervention area, method and effects were analyzed by reviewing full text. Results : The most group and age of participants were normal child with fine motor difficulties and 6~8 years old in selected studies. The most target area of intervention was handwriting, fine motor and visuo-motor integration (68.8%) and the most method was direct treatment (71.4%). The top on the assessment was Beery-Buktenica Test of Visual-Motor Integration (14.9%) and next was Bruininks-Oseretsky Test of Motor Proficiency (11.1%). Effects of school based occupational therapy were founded in the visual motor integration, learning skill, level of participation, fine motor, play and behavioral problem. Conclusion : This systematic review provides evidence concerning the participants, intervention, assessment and effects of school based occupational therapy. It should be used for basic data for the research and practice of school-based occupational therapy.

Difference of Functional Outcome and Related Factors in Patients With Stroke (일부 뇌졸중 환자의 기능변화 및 관련요인)

  • Yi, Seung-Ju;Jeong, Seong-Yeong
    • Physical Therapy Korea
    • /
    • v.14 no.1
    • /
    • pp.46-54
    • /
    • 2007
  • The purposes of the present study were to determine the difference of functional outcome, and to identify factors associated with functional difference in patients with stroke. The sample consisted of 56 stroke patients who had received physical therapy at the physical therapy unit of the Dongeui Medical Center in Busan city between January 2000 and June 2002. Stroke patients were evaluated by physical therapists 3 times; The first day in physical therapy (PT) (T1), one month after the first day in PT (T2), and two months after the first day in PT (T3). Functional status was assessed with the Functional Independence Measure (FIM) instrument, a validated instrument for documenting the severity of disability and assessing the outcome of rehabilitation treatment. Functional gain was calculated over T2-T1, T3-T1, and T3-T2. SAS statistical software was used for the analysis. The Student's t-test, paired t-test, analysis of variance (ANOVA/Tukey and Scheffe), and analysis of covariance (ANCOVA) were used to examine the functional difference in variables. Repeated measures ANOVA was also used to analyze the functional difference by time (T1, T2, and T3). Multiple regression analysis was performed to determine the effects of independent variables on the difference of functional outcome as defined by the FIM score. A total of 56 stroke patients were evaluated, their average age${\pm}$standard deviation was $61.6{\pm}9.3$ years (range: 40~81 yr). The functional status of patients who received physical therapy for about 2~3 months was significantly improved (mean FIM scores, $20.5{\pm}1.8$, $28.9{\pm}1.9$, and $8.41{\pm}1.1$ points for each time period, respectively) (p<.0001). Diabetes was significantly associated with the FIM score for T2-T1 (p<.05). The type of diagnosis was significantly associated with the FIM score for T3-T1 (p<.05). Gender, smoking, and the FIM score on admission were significantly associated with the FIM score for T3-T2 (p<.05). In conclusion, gender, smoking, diabetes, the type of diagnosis, and the FIM score on admission were significantly associated with improved FIM scores. We recommend that further research should explore the functional outcome by using larger sample sizes, longer follow-up periods, and more sensitive assessment instruments.

  • PDF

A study on the Participation Motivation of Clinical Nurses in Job Training (임상간호사의 융복합적 직무교육 참여동기에 관한 연구)

  • Park, Hyun Hee;Lee, Kwang-Ok;Kim, Soon-Ok
    • Journal of Digital Convergence
    • /
    • v.14 no.8
    • /
    • pp.319-329
    • /
    • 2016
  • This study aimed to identify nurses' participation motivation, its influence factors, and their job training need. A survey was conducted on 345 nurses of general hospitals in Gyeonggi-do. Data was collected from October 5th to 18th, 2016 and was analyzed through t-test, ANOVA, Bonferroni post-test, and multiple regressions using SPSS 21.0. Participation motivation was high in 'expertise capability improvement and development' and low in personal gain and job stability. Job training need was the highest in nosocomial infection management and CPR and was the lowest in hospice and rehabilitation nursing. Participation motivation had significant differences depending on age, marital status, educational level, and clinical experience, and was influenced by the job training need of professional nursing and medical knowledge for disease treatment. Therefore, it is necessary to plan medical educational programs to enhance job training effectiveness, establish a strategy to increase participation motivation; and expand various job training support.

A Clinical Case Study of Common Peroneal Nerve Palsy(Foot Drop) Following Entrapment Neuropathy (압박성 신경병증에 의한 족하수(足下垂) 환자(患者) 1례(例)에 대한 임상적(臨床的) 고찰(考察))

  • Shin, Jeong-Cheol;Lee, Dong-Hyun;Wei, Tung-Shuen;Kim, Seon-Jong;Choe, Won-Hwak;Ryu, Chung-Ryul;Yun, Yeo-Choong;Cho, Myung-Rae;Che, Wu-Suk;Na, Gun-Ho
    • Journal of Acupuncture Research
    • /
    • v.22 no.4
    • /
    • pp.1-12
    • /
    • 2005
  • Objectives : The Purpose of this study is to report in patient with common peroneal nerve palsy, who improved by oriental medical treatament. Methods : We Checked the temperature of a leg by Digital Infrared Thermal Imaging(DITI) at intervals of 10 days, angle of active dorsiflexion and range of active motion for estimating the improvement of symptoms. We used the Visual Analogue Scale(VAS) for estimating the degree of pain, too. Results : After 4 weeks treatment, the movement and power of ankle joint improved to nearly normal range. The degree of active dorsiflexion of the ankle increased from $-40^{\circ}\;to\;15^{\circ}$ and range of active motion increased from Gr III to Gr I. The difference of temperature between the both legs decreased remarkably. Conclusion : In this case we experienced improvement of symptoms by conservative oriental medical therapy, e.g acupuncture stimulation, herbal medication, physical therapy. It should be needed further investigation on common peroneal nerve palsy and its symptoms in order to set up a reasonable standard about a surgical operation.

  • PDF

Clinical Study on the Effect of Bee Venom Acupuncture Therapy on the Post-stroke Pain (뇌졸중 후 중추성 통증 환자에 대한 봉독약침요법약침 치료 효과에 대한 임상적 연구)

  • Jeoung, Kyoung-suk;Kim, Su-hyun;Park, Seon-kyeong;Lim, Ho-jae;Yoon, Hyoung-seon;Ahn, Ho-jin
    • Journal of Acupuncture Research
    • /
    • v.22 no.3
    • /
    • pp.69-75
    • /
    • 2005
  • Objective : This study is designed to find out the effect of Bee Venom Acupuncture Therapy on the Post-stroke Pain. Methods : Bee venom solution was injected on Seven Points of CVA-GB2l(肩井), LI15(肩隅), Ll11(曲池), GB31(風市), ST36(足三里), GB39(絶骨), ect- every other day for 3 weeks, in twenty patients who were admitted in Dong-Seo Oriental Medical Hospital, as diagnosed by their typical pain characteristics of central pain from stroke. Result : After 3 weeks treatment, visual analogue scale of pain severity showed significant decrease.

  • PDF

A CASE REPORT OF DENTINOGENESIS IMPERFECTA (상아질 형성부전증에 대한 증례 보고)

  • Jun, Eun-Min;Kim, Eun-Jung;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.323-328
    • /
    • 2006
  • Dentinogenesis imperfecta is an inheritable disease of dentinal defect, generally is inherited as a single autosomal dominant trait. It has a prevalence of 1 in 8000 with the trait, and no significant difference between male and female, with involvement of the primary and permanent teeth. Shields proposed three types of Dentinogenesis imperfecta. Affected teeth have various discoloration, separation of enamel rapid destruction of underlying dentin, and severe attrition. Radiographically, the teeth have cervical constriction, bulbous crown, thin root, obliteration of the root canals and pulp chambers, and periapical lesions in a sound tooth. The objective of treatment is rehabilitation of the esthetics, the masticatory function, and the vertical dimension of occlusion. In these cases, two pediatric patients reported to the Kyungpook University Pediatric clinic, with a chief complaint of discolored teeth and severe attrition. As a result of clinical and radiographic exam, it was diagnosed as Dentinogenesis imperfecta. The posterior teeth were restored with Stainless Steel Crown, and the anterior teeth were restored with composite resin veneering.

  • PDF

An investigation of reosseointegration according to time course after mechanical loosening of the osseointegrated implant fixtures (표면처리 임플란트 고정체의 의원성 동요 후 시간 경과에 따른 재골유착에 관한 연구)

  • Ye, Sun-Hae;Cho, Jin-Hyun;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.203-211
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the reosseointegration periods when the rough surface implants, which had complete bone-implant ankylosis, suddenly losed the osseointegration. Materials and Methods: The implants with RBM surface treatment were inserted into both tibias of 23 rabbits. Two implants were submerged into each side. After six weeks, the primary removal torque was measured by Digital torque gauge, and then the implants were replaced and submerged to estimate the level of reosseointegration. After assigned healing periods for each group, the removal torque was measured again. BIC (Bone-Implant contact, %) ratio was measured through histomorphometric analysis.Paired t-test was processed by SPSS 14.0. One-way ANOVA and Tukey's post-hoc test was processed to analyze statistically significant differences among the groups. Results: In comparison with the primary removal torque, the secondary removal torque was increased after 11 days and significantly increased from 2 weeks. In fluorochrome labeling, the origin of mineralization was observed after 7 days, which showed as fluorescent bands around the bone-implant interfaces. After 11 days, the bone formation was apparent, and it is increased continuously with the passage of the time. Conclusion: In 11 days after the implant replacement, the secondary removal torque was almost as same as the primary value, and was significantly higher from 2 weeks. The mineralized shapes were observed in 7 days after the implant replacement, and then the bone formation appeared visibly in 11 days.