• Title/Summary/Keyword: Regeneration temperature

Search Result 328, Processing Time 0.03 seconds

Thermodynamic Performance Analysis of Ammonia-Water Power Generation System Using Low-temperature Heat Source and Liquefied Natural Gas Cold Energy (저온 열원과 LNG 냉열을 이용하는 암모니아-물 동력 사이클의 열역학적 성능 해석)

  • Kim, Kyoung Hoon;Kim, Kyung Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.483-491
    • /
    • 2014
  • In this study, a thermodynamic analysis was carried out for a combined power generation system using a low-temperature heat source in the form of sensitive energy and liquefied natural gas cold energy. An ammonia-water mixture, which is a zeotropic mixture, was used as the working fluid, and systems with and without a regenerator were comparatively analyzed. The effects of the mass fraction of ammonia and the condensation temperature of the working fluid on the system variables, including the net work production, exergy destruction, and thermal and exergy efficiencies, are analyzed and discussed. The results show that the performance characteristics of the system varied sensitively with the ammonia concentration or condensation temperature of the working fluid. The system without regeneration was found to be better in relation to the net work per unit mass of the source fluid, whereas the system with regeneration was better in relation to the thermal or exergy efficiency.

Investigation of Catalytic Deactivation by Small Content Oxygen Contained in Regeneration Gas Influenced on DSRP (직접 황 회수 공정으로 유입되는 재생가스에 함유된 미량산소의 촉매활성저하 원인 규명)

  • Choi, Hee-Young;Park, No-Kuk;Lee, Tae Jin
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.212-217
    • /
    • 2014
  • In order to regenerate the sulfidated desulfurization sorbent, oxygen is used as the oxidant agent on the regeneration process. The small amount of oxygen un-reacted in regeneration process is flowed into direct sulfur recovery process. However, the reactivity for $SO_2$ reduction can be deteriorated with the un-reacted oxygen by various reasons. In this study, the deactivation effects of un-reacted oxygen contained in the off-gas of regeneration process flowed into direct sulfur recovery process of hot gas desulfurization system were investigated. Sn-Zr based catalysts were used as the catalyst for $SO_2$ reduction. The contents of $SO_2$ and $O_2$ contained in the regenerator off-gas used as the reactants were fixed to 5.0 vol% and 4.0 vol%, respectively. The catalytic activity tests with a Sn-Zr based catalyst were for $SO_2$ reduction performed at $300-450^{\circ}C$ and 1-20 atm. The un-reacted oxygen oxidized the elemental sulfur produced by $SO_2$ catalytic reduction and the conversion of $SO_2$ was reduced due to the production of $SO_2$. However, the temperature for the oxidation of elemental sulfur increased with increasing pressure in the catalytic reactor. Therefore, it was concluded that the decrease of reactivity at high pressure is occurred by catalytic deactivation, which is the re-oxidation of lattice oxygen vacancy in Sn-Zr based catalyst with the un-reacted oxygen on the catalysis by redox mechanism. Meanwhile the un-reacted oxygen oxidized CO supplied as the reducing agent and the temperature in the catalyst packed bed also increased due to the combustion of CO. It was concluded that the rapidly increasing temperature in the packed bed can induce the catalytic deactivation such as the sintering of active components.

The Effect of ZnO Content on the Performance of Spray-dried Zn-based Desulfurization Sorbent for H2 Cleanup (황화수소 정제용 아연계 분무건조 탈황제의 활성성분 함량 변경에 따른 물성 및 반응 특성)

  • Baek, Jeom In;Eom, Tae Hyoung;Lee, Joong Beom;Jegarl, Seong;Ryu, Chong Kul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.482-490
    • /
    • 2014
  • Gaseous sulfur compound such as $H_2S$ or COS in coal- or biomass-derived hot syngas can be purified by solid sorbents at high temperatures. In this study, we investigated the physical properties and reactivity of solid regenerable desulfurization sorbents with 37.2, 41.9, and 46.5wt% ZnO to look into the ZnO content effect. The sorbents were produced by spray-drying method to apply to a fluidized-bed process. Sulfidation and regeneration reaction were carried out using a thermogravimetric analyzer. Sorbent prepared with 46.5wt% ZnO had physical properties suitable for a fluidized-bed process applications such as spherical shape, sufficient mechanical strength and density, high porosity and surface area. It showed high sulfur sorption capacity of 10.4wt% (ZnO utilization of 57%) at reaction temperatures of 500 and $650^{\circ}C$ for sulfidation and regeneration, respectively. However, the sulfur sorption capacity and ZnO utilization were significantly reduced and dimple shape appeared when the ZnO content decreased to 37.2 and 41.9wt%. Sulfur sorption capacity and regenerability were improved as reaction temperature increased within the experimental temperatures used in this work. The reaction temperature zones of $1500{\sim}550^{\circ}C$ and $650{\sim}700^{\circ}C$ are recommended for sulfidation and regeneration, respectively, to lead best reaction performances of the ZnO-based spray-dried sorbents developed in this work.

Absorption and Regeneration of Carbon Dioxide in Aqueous AMP + AEPD and AMP + TIPA Solutions (AMP + AEPD와 AMP + TIPA 수용액을 이용한 이산화탄소의 흡수 및 재생)

  • Kim, Mi-Sook;Choi, Won-Joon;Seo, Jong-Beom;Cho, Ki-Chul;Kim, Soo-Gon;Oh, Kwang-Joong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.539-546
    • /
    • 2007
  • Increasing emission of $CO_2$ significantly effects the global warming. Chemical absorption is one of separation methods of $CO_2$ from the industrial flue gases. In this study, the $CO_2$ removal efficiency as well as the $CO_2$ absorption amount of aqueous AMP (2-amino-2-methyl-1-propanol) solutions were measured using the continuous absorption and regeneration apparatus. We investigated the effect of aqueous AMP+AEPD(2-amino-2-ethyl-1, 3-propanediol) and AMP+TIPA (triisopropanolamine) solutions to enhance absorption characteristics of AMP. As a result of this study, the absorption amount and $CO_2$ removal efficiency were increased with adding TIPA into 30 wt.% AMP. The absorption amount and $CO_2$ removal efficiency of aqueous 30 wt.% AMP+5 wt.% TIPA solution were $1.70\;kg-CO_2/kg-absorbent$ and 91.1%, while those of aqueous 30 wt.% AMP solution were $1.58\;kg-CO_2/kg-absorbent$ and 89.3%. In addition, aqueous 30 wt.% AMP+5 wt.% TIPA solution used in the study revealed the high stripping efficiency, which was almost 98%, at the temperature of $110^{\circ}C$. Thus, the temperature of regenerator should be operated at $110^{\circ}C$.

Regeneration of Spent Nickel Catalyst for Hydrogenation (수소화 반응용 니켈 폐촉매의 재생)

  • 전종기;박영권;김주식
    • Resources Recycling
    • /
    • v.13 no.3
    • /
    • pp.27-36
    • /
    • 2004
  • Nickel oxide was recovered through roasting of a spent catalyst for hydrogenation reaction. Nickel on Kieselguhr catalysts were prepared by a precipitation method after a treatment of the recovered-nickel oxide with an acid. Effects of roasting temperature of the spent catalyst on recovery of nickel oxide was investigated. Most of nickel oxide could be recovered through roasting of the spent catalyst at $1000^{\circ}C$. In regeneration of catalysts by the precipitation method after the treatment of nickel oxide with an acid, the effect of promoter, precipitation condition and reduction condition on catalytic performance in vegetable oil hydrogenation were investigated. The addition of CaO or $Ce_2$$O_3$ resulted in an increase of catalytic activity.

The Application of Dump Combustor for Evaluation of After-Treatment System (후처리장치 성능 평가를 위한 Dump Combustor의 활용)

  • Nam, Youn-Woo;Lee, Won-Nam;Oh, Kwang-Chul;Lee, Chun-Beom
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.3
    • /
    • pp.16-23
    • /
    • 2007
  • Employing an after-treatment system has almost become a mandatory requirement for Diesel vehicles, which results from a reinforced exhaust regulations as the number of vehicles powered by a Diesel engine increases. The Diesel Particulate Filter (DPF) system is considered as one of the most efficient method to reduce particulate matter (PM); however, the improvement of a regeneration performance at any engine operation point presents a considerable challenge by itself. Temperature, gas composition and flow rate of exhaust gas are important parameters in DPF evaluation processes, especially during a regeneration process. Engine dynamometer and segment tester are generally used in DPF evaluation so far. These test methods, however, could not completely evaluate the effect of various parameters on real DPF, such as oxygen concentration, amount of soot and exhaust gas temperatures. The evaluation of DPF systems using a dump combustor has been verified experimentally and this dump combustor system is likely to be appropriate for the DOC (Diesel Oxidation Catalyst) and SCR (Selective Catalytic Reduction) assessments test, too.

  • PDF

Isolation of Uracil and Tryptophan Auxotrophs of Bacillus subtilis and Regeneration of their Protoplasts (Bacillus subtilis의 $Ura^-$$TrP^-$균주(菌株)의 육성(育成)과 Protoplast 조제(調製) 및 Regeneration)

  • Ha, Il-Ho;Lee, Ke-Ho
    • Applied Biological Chemistry
    • /
    • v.28 no.1
    • /
    • pp.13-18
    • /
    • 1985
  • To investigate the fusion of bacterial protoplasts, two auxotrophic mutants of Bacillus subtilis were isolated after treatment with nitrosoguanidine. Two auxotrophs were uracil-auxotroph and tryptophan-auxotroph. Back mutation frequencies of $ura^-$ and $trp^-$ -auxotrophs were $2.4{\times}10^{-8}$ and less than $1.0{\times}10^{-8}$, respectively. The optimal pH and temperature of protoplast formation with lysozyme were 6.5 and $30^{\circ}C$. The optimal lysozyme concentration was $200{\mu}g/ml$. The regeneration frequency of protoplast was 3.3%.

  • PDF

Performance Evaluation of an Electrohydrodynamic Spray Nozzle for Regeneration of Particulate Matter on Diesel Particulate Filter (경유차 입자상물질 저감필터(DPF) 재생용 전기수력학적 연료 후분사 노즐의 미립화 특성 평가 및 수치해석을 이용한 액적 입경별 연소 특성 평가)

  • Jeong, Seonghun;Park, Sung-Eun;Kim, Min-Jung;Cho, Hyung-Jei;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.8 no.2
    • /
    • pp.55-68
    • /
    • 2012
  • Particulate matters (PM) which are collected into a diesel particulate filter (DPF) system have to be periodically removed by thermal oxidation. In this report, we fabricated an electrohydrodynamic-assisted pressure-swirl nozzle to spray diesel droplets finer. Atomization performance of the nozzle was evaluated using both experimental and numerical methods. Two types of nozzle designs, the charge induction type and the charge injection type, were tested. While the former generated diesel droplets of $400\;{\mu}m$ at an applied electric potential over 10 kV, the latter presented the droplets smaller than $23\;{\mu}m$ at an applied electric potential of 8 kV. The numerical simulation results showed that the reduced size of droplets caused higher evaporation of droplets and therefore the increased temperature, which would eventually increase the regeneration performance of the DPF system.

PStudy on Characteristics of Dryness Storage Tank, Component of Open-type Dehumidifying and Drying System using Solar Energy(I Experiment on Flowing Characteristics of Storage Tank for Regenerator) (태양열을 이용한 개방형 제습.건조시스템의 저장탱크 유동특성에 관한 연구(제1보 재생기용 저장탱크의 유동특성에 관한 실험))

  • Kim, J.R.;Choi, K.H.;Kum, J.S.;Kim, J.R.
    • Solar Energy
    • /
    • v.20 no.2
    • /
    • pp.1-8
    • /
    • 2000
  • The present study has been conducted to offer geometrically optimal structure of a storage tank for a regenerator, one of the components of an open-type dehumidifying and drying system using solar energy to develop an alternatives for time-limited energy such as a fossil fuel, and to decrease an environmental pollutant. Two kinds of model classified by the mixing process were suggested to estimate the amount of regeneration rate. One was the stratified-type, "case 1", a method to place an entrance in the upper part of the tank and an outlet in the lower part. The other was the mixed-type, "case 2", a method to place vice versa. Solution temperature and concentration were used to evaluate the regeneration rate. As a result, the regeneration rate was better in "case 2".

  • PDF

Study on Characteristics of Dryness Storage Tank, Component of open-type Dehumidifying and Drying System using Solar Energy (2nd Paper: Experiment on Influence of Baffle Plates Installed in the Tank) (태양열을 이용한 개방형 제습.건조시스템의 저장탱크 유동특성에 관한 연구(제2보 배플 설치의 영향에 관한 실험))

  • Kim, J.R.;Choi, K.H.;Kum, J.S.;Kim, J.R.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.25-30
    • /
    • 2000
  • The present study has been conducted to offer an geometrically optimal structure of a storage tank for a regenerator. In this paper, three kinds of baffle plates supposed to increase the regeneration rate and classified as "Type A($L^*$=0.25, 80(L)$\times$300(W)$\times$50 (H) [mm])", "Type B($L^*$=0.5, 150(L)$\times$300(W)$\times$50 (H) [mm])", and "Type C($L^*$=0.75, 230(L)$\times$300(W)$\times$50(H) [mm])" were suggested and tested. They were placed between the vertical C-C layers in the tank. Solution temperature and concentration were used to evaluate the regeneration rate. As a result, the regeneration rate was better in "Type C".

  • PDF