• Title/Summary/Keyword: Refuse Derived Fuel (RDF)

Search Result 51, Processing Time 0.028 seconds

Dehydration and RDF Production of Organic Sludge with Hydrothermal Pre-treatment Process (증기열 전처리공정을 이용한 유기성 슬러지의 건조 및 성형연료화)

  • Park, Se-Joon;Choi, Yong-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.526-531
    • /
    • 2009
  • This paper suggests the dehydration and RDF(Refuse Derived Fuel) production of organic sludge, livestock manure and sewerage sludge causing environmental problems, with hydrothermal pre-treatment process. The renewable technology from the organic wastes must involve short treatment time required, reusable energy source, anti-odor and viruses, low cost for the treatment, and well-fertilization. The hydrothermal pre-treatment process promotes to evaporate moisture in the sludge after being shortly treated in a reactor, which is supplied steam and heat by an external boiler, due to the pressure with steam breaks the cell walls of the sludge, so this process removes the internal moisture of the cell. Then, the treated sludge(solid-state) is mixed with waste vinyls called RDF(6,706kcal/kg).

A Study on Fire Risk & Countermeasure of RDF(Refuse Derived Fuel) (생활폐기물 고형연료제품의 화재위험과 안전대책에 관한 연구)

  • Jeong, Ui-Su;Gang, Gyeong-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.04a
    • /
    • pp.17-25
    • /
    • 2009
  • 세계의 모든 나라가 화석연료를 대체하는 태양광, 풍력 등의 그린에너지 기술개발에 주력하고 있으며, 한편으로는 에너지의 효율제고 및 재생을 위하여 폐기물로부터의 자원순환을 이룩하는 폐기에너지 회수에도 많은 노력을 기울이고 있다. 그 하나의 방편이 버려지는 쓰레기에서 에너지를 회수하는 고형재생연료인 RDF(생활폐기물 고형연료 제품, Refuse Derived Fuel) 생산이다. 우리나라에서는 유일하게 강원도 원주시에서 하루 80톤을 생산하고 있으며 아직은 기술도입 초기단계에 있는 가연성폐기물의 연료화 기술이다. RDF의 특성은 불연성 성분이 제거된 일반 가연물을 분쇄하여 압출성형 가공한 펠릿형상의 고체연료로서의 열적 특성이 우수하나 화재안전 측면에서는 제조 및 취급공정에서의 일반적인 가연물 화재위험성을 가지고 있고, 저장과정에서는 축열발열에 의한 자연발화 위험성이 상존하며, 저장형태, 특히 사이로의 경우 구조특성으로 인하여 화재진압도 쉽지않다. 본 논문에서는 일본의 RDF 화재사례를 중심으로 그 화재 위험 특성과 안전대책을 고찰하고자 한다.

  • PDF

Dehydration and RDF Production of Organic Wastes with Pressurized Hydrothermal Treatment Process (증기가압형 처리공정을 이용한 유기성 폐기물의 건조처리 및 고형연료화)

  • Park, Se-Joon;Choi, Young-Chan;Choi, In-Kyu
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.5
    • /
    • pp.439-446
    • /
    • 2009
  • This paper investigates the dehydration and RDF (Refuse Derived Fuel) production of organic wastes, livestock manure and sewerage sludge with pressurized hydrothermal treatment process. The renewable technology for the organic wastes must involve short treatment time required, reusable energy source, anti-odor and viruses, low cost for the treatment, and well-fertilization. The pressurized hydrothermal treatment process promotes to evaporate moisture in the waste after being shortly treated in a reactor, which uses steam and heat supplied by an external boiler. By the pressurized steam, the cell walls of the waste break and effectively release the internal moisture. Then, the dried waste can be mixed with waste vinyls to produce RDF with a higher heating value as high as 6,700 kcal/kg.

Study on the HCl Exhaust and Reduction Characteristics of Refuse-Derived Fuel (폐기물(廢棄物) 고형연료(固形燃料)(RDF) 연소시의 염화수소(鹽化水素) 발생 및 저감 특성 연구)

  • Nho, Nam-Sun;Kim, Kwang-Ho;Jeon, Sang-Goo;Lee, Kyong-Hwan;Shin, Dae-Hyun;Suh, Jee-Mi;Park, Hyo-Nam
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2005.10a
    • /
    • pp.70-74
    • /
    • 2005
  • 최근에 국내에서 활발히 보급되기 시작한 폐기물 고형연료(Refuse-Derived Fuel : RDF)에 적합한 HCl 배출 저감설비의 개발에 필요한 기본적인 자료를 확보하기 위한 첫 번째 단계로서 RDF 연소시의 HCl 생성 및 저감 특성에 대한 실험실적인 기초 실험을 수행하였다. 개당 무게가 $2{\sim}3\;g$ 정도인 RDF 시료는 실험실적 방법으로 제조하였고, Ca 계통의 흡수제를 선택하여 RDF 중의 Cl 함량 및 원료 조성에 따른 HCl 배출농도 및 흡수제 사용량, Ca/Cl 몰비에 따른 HCl 제거효율, 연소 조건별 생성물질, 반응온도별 HCl 배출농도 및 회재의 Cl 함량, 흡수제별 HCl 저감효율 변화 등을 살펴보았다. 또한 40 kg/hr과 200 kg/hr의 용량을 가진 RDF 연소용 실험설비에서 측정된 HCl 배출농도, RDF의 Cl 함량, 회재 종류별 Cl 함량 분포 등을 기초실험 결과와 비교분석하였다.

  • PDF

Study on applicability of RDF in Municipal Waste Landfill Site (생활폐기물매립장에서의 RDF 적응가능성에 대한 연구)

  • Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.18 no.10
    • /
    • pp.1181-1187
    • /
    • 2009
  • Results for application of RDF(Refuse Derived Fuel) to selected wastes in metropolitan and small and medium cities are as follows. The physical characteristics of waste are paper, plastic, food waste, and so on. The proximate analysis in P city showed 20.2% of moisture, 71% of combustible material, and 8.8% of ash on annual average. That in G city showed 31.6% of moisture, 59.5% of combustible material, and 8.9% of ash. Ultimate analysis in P city showed 52.04% of carbon, 7.02% of hydrogen, 28.80% of oxygen, 0.66% of nitrogen, and 0.09% of sulfur. Heating value was 3,363 kcal/kg. Ultimate analysis in G city showed 50.85% of carbon, 6.56% of hydrogen, 29.86% of oxygen, 0.79% of nitrogen, and 0.12% of sulfur. Heating value in the G city was somewhat lower than that in the P city with 2,632 kcal/kg. Thus, application of RDF in metropolitan city was more effective than that in small and medium cities. Heating value in mixture for the P city was lower than that in waste of the volume rate waste charge system alone by 143 kcal/kg. In proximate analysis, moisture, and combustible material were likely to be more adequate to RDF.

Co-combustion of RPF in the Coal Power plant (석탄보일러에서 각종 RDF혼소시 다이옥신 농도 조사)

  • Choi, Yeon-Seok;Choi, Hang-Seok;Kim, Seock-Joon;Yoon, Kyoon-Duk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.452-455
    • /
    • 2008
  • The co-combustion of coal and three kinds of RDFs(Refuse Plastic Fuel) mixture has been experimented in a commercially operating CFB coal boiler respectively and the pollutant emissions such as SOx, NOx, TSP and dioxine were measured at the stack. The mixing ratio with coal was 7.5% RPF, 7.5% RDF and 10% SDF respectively. During co-combustion, dioxine emission level was very low and SOx, NOx and TSP were decreased comparing the single coal combustion. Emitting dioxine concentration was proportioned to the chlorine content of RDF. These RPF, SDF and RDF could be determined to be a good alternative fuel of general coal.

  • PDF

A Study on the Combustion Characteristics of Pelletized and Fluff RDF (Refuse Derived Fuel) (성형 및 비성형 폐기물 고형연료의 연소특성에 관한 연구)

  • Sanjel, Nawaraj;Gu, Jae-Hoi;Kwon, Woo-Teck;Oh, Sea Cheon
    • Applied Chemistry for Engineering
    • /
    • v.23 no.3
    • /
    • pp.333-338
    • /
    • 2012
  • To verify the utilization of fluff refuse derived fuel (RDF) as energy source, the combustion charateristic has been studied by an experimental combustion furnace under various temperatures. The characteristics of flue gas, dust and residue from fluff RDF combustion has been analyzed and compared with those of pelletized RDF. From this work, it was found that the incomplete combustion of fluff RDF was greater than that of pelletized RDF because the combustion reaction rate of fluff RDF was faster than that of pelletized RDF, and oxgen concentration in fluff RDF combustion decreased rapidly. It was also found that carbon monoxide concentration of flue gas from fluff RDF combustion increased with combustion temperature because the oxygen consumption and the incomplete combustion increased. Therefore, it is felt that the combustion operation conditions of fluff RDF should be carefully determined.

Circulting Fluidized Bed Combustion of Refuse Derived Fuel and Steam Production (폐기물 고형연료(RDF)의 순환유동층 연소 및 증기생산)

  • Shun, Do-Won;Bae, Dal-Hee;Cho, Sung-Ho;Lee, Seung-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.613-616
    • /
    • 2007
  • A pilot scale circulating fluidized bed for refuse derived fuel is developed and constructed in order to demonstrate efficient and safe utilization of waste fuel. The capacity of the facility is 8 steam tons per hour with the steam quality of $450^{\circ}C$ and 38atm. The quantity and the quality of the produced steam is sufficient to produce 1MWe power capacity. The test operation proved the high combustion efficiency of 99% and up. The emissions of NOx, SOx in flue gas are below 100, 60ppm respectively with out any emission control. HCl emissions were above 400ppm at the combustor exit but reduced below 10ppm after scrubber.

  • PDF

A Study on the RDF fuel mixing with household and organic wastes (생활(生活)쓰레기 및 유기성폐기물(有機性廢棄物) 혼합(混合)에 따른 RDF 연료화(燃料化)에 관한 연구(硏究))

  • Ha, Sang-An;You, Mi-Young;Kim, Dong-Kyun;Wang, Jei-Pil
    • Resources Recycling
    • /
    • v.20 no.5
    • /
    • pp.52-57
    • /
    • 2011
  • This study was conducted to examine the possibilities to utilize the mixture of domestic and organic wastes from B-city as a fuel. All types of mixing ratio for uncarried waste, sludge cake, and food waste were found 10 generate heating value with 6,000 kcal/kg, and in case of sludge cake the concentration of toxic substance produced was found to be decreased as air-fuel ratio and temperature were increased. It was noted that toxic gases such as CO, NOx, and SOx were observed below concentration of emission standard, and temperature inside the incinerator was stabilized at 2 of air-fuel ratio and 800$^{\circ}C$. It was observed that a heating value of 6000 kcal/kg generated using RDF(Refuse Derived Fuel) was appropriate to utilize a fuel if a complete combustion was attained.