R&D OF FREEZING AND REFRIGERATION SYSTEM USING CHP. (가역 화학 열 펌프(CHP)를 이용한 냉장.냉동 시스템 개발 연구)

  • 이종호;김석종
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.132-135
    • /
    • 1996
  • This study is to develop an ammonia based chemical heat pump(STELF) for a freezing and refrigeration system coupled to gas, fuel and/or waste from industrial processes as heat sources. Recently it has been continually taking a growing interest in chemical heat pumps without electric power and having higher COP's than those of existing compression type refrigeration systems using freon. By introducing STELF technology, efficient heat recovery utilizing enormous amount of waste heat in energy consuming large scale industries or building for their own refrigeration purposes is possible. Moreover, air-conditioning systems coupled to city gas for small scale industries or building can be realized. Therefore, STELF technology can contribute much for overall energy savings and efficient energy management.

  • PDF

Thermal stability of superconducting systems conduction-cooled by cryocooler (극저온냉동기로 전도냉각되는 초전도시스템의 열적 안정성)

  • 권기범;장호명
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.56-63
    • /
    • 2001
  • The thermal stability conditions are investigated for superconducting magnet systems cooled conductively by cryocooler without liquid cryogens. The worst scenario in the systems is that the heat generation in the resistive state exceeds the refrigeration. causing a rise in the temperature of the magnet winding and leading to the burnout. It is shown by an analytical solution that in the continuous resistive state, the temperature may increase indefinitely or a stable steady-state may be reached, depending upon the relative size of the magnet with respect to the refrigeration capacity of the cryocooler. The stability criteria include the temperature-dependent Properties of the magnet materials and the refrigeration characteristics of the cryocooler. A useful graphical scheme is Presented and discussed to demonstrate the physical importance of the results.

  • PDF

Lubrication Characteristics Between the Vane and the Rolling Piston in a Rotary Compressor Used for Refrigeration and Air-Conditioning Systems

  • Jung, Jae-Youn;Oh, Seok-Hyung;Cho, Ihn-Sung
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.562-568
    • /
    • 2001
  • The rolling piston type-rotary compressor has been widely used for refrigeration and air-conditioning systems due to its compactness and high-speed operation. The present analysis is part of a research program directed toward maximizing the advantages of refrigerant compressors. The study of lubrication characteristics in critical sliding components is essential for the design of refrigerant compressors. Therefore, theoretical investigation of the lubrication characteristics of a rotary compressor used for refrigeration and air-conditioning systems was studied. The Newton-Raphson method was used for the partial elastohydrodynamic lubrication analysis between the vane and the rolling piston of a rotary compressor. The results showed that the rotational speed of a shaft and the discharge pressure significantly influence the friction force and the energy loss between the vane and the rolling piston.

  • PDF

Experimental Study on Mass Transfer Rate at the Packed Column of Solar Cooling Liquid Desiccant System Using Counter Flow Configuration

  • Hengki R, R.;Choi, K.H.;Yohana, Eflita;Sukmaji, I.C.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.155-161
    • /
    • 2009
  • Desiccant systems have been proposed as energy saving alternatives to vapor compression air conditioning for handling the latent load. Use of liquid desiccants offers several design and performance advantages over solid desiccants, especially when solar energy is used for regeneration. The liquid desiccants contact the gas inside the packed column and the heat transfer and mass transfer will occur. This proposal is try study the mass transfer and heat transfer inside the packed column of dehumidifier and regenerator systems. And later on, the rates of dehumidification and regeneration that were affected by desiccant flow rates, air temperature and humidity, and desiccant temperature and all that variation will influence the performance of the systems.

  • PDF

The Lubrication Characteristics of a Rotary Compressor Used for Refrigeration and Air-conditioning Systems (Part III; Analysis of partial elastohydrodynamic lubrication on vane tip)

  • 조인성;오석형;정재연
    • Tribology and Lubricants
    • /
    • v.17 no.2
    • /
    • pp.138-145
    • /
    • 2001
  • The rolling piston type rotary compressor has been widely used for refrigeration and air-conditioning systems due to its compactness and high-speed operation. The present analysis is a part of research program directed toward maximizing these advantages of refrigerant compressors. The study of lubrication characteristics in the critical sliding component is essential for the design of refrigerant compressors. Therefore, theoretical investigation of the lubrication characteristics of a rotary compressor used for refrigeration and air-conditioning systems is studied. Newton-Raphson method is used for the partial elastohydrodynamic lubrication analysis between vane and rolling piston in the rotary compressor. The results show that the rotational speed of a shaft and the discharge pressure influence significantly the friction force and the energy loss between vane and rolling piston.

Friction Characteristics Between Vane and Rolling Piston in a Rotary Compressor Used for Refrigeration and Air-Conditioning Systems

  • Cho, Ihn-Sung;Baek, Il-Hyun;Oh, Seok-Hyung;Jung, Jae-Youn
    • KSTLE International Journal
    • /
    • v.9 no.1_2
    • /
    • pp.17-21
    • /
    • 2008
  • The rolling piston type rotary compressor has been widely used for refrigeration and air-conditioning systems due to its compactness and high-speed operation. The present study is one of studies to maximize the advantages of refrigerant compressors. In addition, because friction characteristics of the critical sliding component is essential in the design of refrigerant compressors, the present study also analyzed the lubrication characteristics of a rotary compressor used for refrigeration and air-conditioning systems. In order to measure the friction force between the vane and the rolling piston, an experimental apparatus known as the Pin-on-Disk was used. Load is applied by the hydraulic servo valve controlling the pressure of the hydraulic cylinder. The results showed that the rotational speed of the shaft, the operating temperature, and the discharge pressure significantly influenced the friction force between the vane and the rolling piston.

Research and Development of the Triple Effect Absorption Chiller-Heater Technology in Japan

  • Kashiwagi, Takao;Akisawa, Atsushi;Hamamoto, Yoshinori
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.3
    • /
    • pp.43-49
    • /
    • 2004
  • This article reviews R&D of triple effect cycle developed in Japan. Most of the refrigeration and heat pump technologies are dominated by vapor compressor system. The vapor compressor system, however, is highly concerned with the environmental regulations , as most of the vapor compressor technologies are using CFCs or HCFCs which are known as ozone depleting and global warming gases. As a consequence, refrigeration technologists are trying to invent or to develop an alternative to vapor compressor refrigeration devices. Thermally driven, absorption technology is one of the possible alternatives. At the moment, absorption cycle is most promising technology The paper summarizes briefly the current research and development in advanced technologies of triple effect absorption chiller-heater in Japan.(omitted)

  • PDF

Control of Refrigerating Compressor Capacity Using Inverter (인버터를 이용한 냉동용 압축기의 용량 제어)

  • Yang, H.S.;Kim, H.S.;Kim, J.H.;Kim, S.B.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.2
    • /
    • pp.94-101
    • /
    • 1993
  • Recently, efforts of decreasing energy consumption are continously increased and user's preference is also diversified in refrigeration and air conditioning systems. Thus, in order to satisfy these demands, high efficiency, high intelligence, and energy saving for those systems are essential. As the basic study for diverse functions and intelligence of those systems, we investigated the response characteristics through the compressor capacity control concerned with superheat and refrigeration room temperature. And, response characteristics are investigated experimentally by using micro computer based PWM inverter control method. Experimental result of the conventional on-off control method is given in order to be compared to the results of inverter control method. The results obtained through this study are summarized as follows. It is shown from the experimental results of the on-off control method that the range of temperature variation around the steady state ($-18^{\circ}C$) is very large (about $7{\sim}8^{\circ}C$) and the settling time bringing the steady state is not found. In the inverter control method, we can see that the refrigeration room temperature after reaching the setting temperature is very stable without fluctuation and a robust control for disturbance such as opening the door has been realized.

  • PDF

The Effect of LiBr Concentration on Corrosion of Absorption Refrigeration Systems Using $LiBr-H_2O$ Working Fluids ($LiBr-H_2O$계 흡수식냉동기의 부식에 미치는 LiBr 농도의 영향)

  • Lim Uh Joh;Jeong Ki Cheol
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.33-39
    • /
    • 2001
  • This paper was studied on corrosion behavior of absorption refrigeration systems using $LiBr-H_2O$ working fluids. In the various concentration of lithium bromide solution, polarization test of SS 400, Cu(C1220T-OL) and Al-Ni bronze is carried out. And the corrosion behavior of materials forming absorption refrigeration systems is investigated. The main results are as following: 1) As concentration of lithium bromide solution increases, polarization resistance of materials of each kinds is low. And open circuit potential becomes less noble, the corrosion current density is high drained 2) Open circuit potential of SS 400 is less noble than that of Cu and Al-Ni bronze, corrosion current density of SS5 400 is high drained than that of Cu and Al-Ni bronze. 3) Anodic polarization of Cu and Al-Ni bronze in $62\%$ LiBr solution continues the active state. that of Cu and Al-Ni bronze in the natural sea water maintains the active state and the critical current for passivation appears.

  • PDF

Performance Analysis of Refrigeration System by Adjusting Manual Expansion Valve (수동식 팽창밸브 조정에 의한 냉동시스템의 성능 분석)

  • Yang, Hyung-Suk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.3
    • /
    • pp.113-119
    • /
    • 2011
  • This study analyzed facts affecting the performance of refrigeration systems after throttling actions, by changing the amount of refrigerant according to adjusting the opening of manual expansion valve to 80%, or 20% with vapor compressional refrigeration training equipment. At opening of 20%, the inlet and outlet temperature of compressor, subcooling and superheat, condenser heat, refrigeration effect, flash gas heat, coefficient of performance were higher, while at 80%, condensing pressure, evaporating pressure, compression work were higher, Thus, we could see changes in the amount of refrigerant affect the performance of the refrigeration system.