• 제목/요약/키워드: Refrigerating effect

검색결과 935건 처리시간 0.042초

국소적 연돌효과 저감대책의 효용성에 관한 연구 (A Study on the Usefulness of the Countermeasures locally for the stack-effect in High-rise building)

  • 서정민;임현우;이준호;이중훈;송두삼
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.300-305
    • /
    • 2009
  • High-rise buildings have some problems by stack effect. And, the solutions on the problems should be determined by considering an overall building. But, ordinarily, the countermeasures on the problems are applied to local part of the building. Local countermeasures often can be possible to arouse the secondary problems accompanied by the stack-effect. In this study, the usefulness of local countermeasures are evaluated in terms of both the reduction effect on problems and the possible secondary problems with simulations. The simulation results show that the application of countermeasures on an overall building is very important and that local countermeasures can be used optionally according to building's conditions.

  • PDF

CFD를 이용한 초고층빌딩 누드 엘리베이터의 온열 및 연돌현상에 관한 연구 (A Study on the Thermal Phenomena and Stack Effect of Nude Elevator Shaft of High Rise Building that used CFD)

  • 박정한
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1059-1064
    • /
    • 2008
  • The present study is to reduce the thermal phenomena and stack effect of nude elevator of the high-rise building used CFD simulation. Since many High-rise buildings used the curtain-wall glass, thermal phenomena and stack effect can easily occur at hot and cold season, respectively. The simulation has been conducted and verified for the effects of the amount of suppling air to the environment of the inside nude elevator shaft. The results of simulations show that the problems due to the thermal and stack effect will be reduced by enforced ventilation or natural ventilation and those will be presented by temperature and velocity profiles and pressure differences.

  • PDF

단열재 두께 변화와 창호 침기 부하와의 관계 (A Study on Relationship Insulation Thickness and Infiltration Load by Window)

  • 최정민;조성우
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.422-427
    • /
    • 2012
  • This study investigates on the relationship between total load which is caused by infiltration and insulation thickness against compensation effect. As the result of experiment, the PVC(Synthetic resins sash) window frame in airtightness is superior to the AL(Aluminum sash) window frame. In this study, as the increasing of insulation thickness in reference building does not reduce significantly cooling load, the compensation effect due to airtightness against infiltration is very small. But the compensation effect against infiltration can be closely related with heating load. Therefore, the proper thermal insulation thickness can be needed respect to cooling and heating load.

수냉형 직렬방식 2중효용 흡수식 냉방기의 열해석과 최적 설계 (Thermal Analysis and Optimum Design of Water-Cooled, Series-Flow Type, Double-Effect Absorption Heat Pump)

  • 오명도;김영률;김선창;김영인
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.332-341
    • /
    • 1992
  • An absorption heat pump cycle has been modeled and simulated to analyze the system performance of water-cooled, series-flow, double-effect absorption heat pump, which can be applied to a direct gas fired cooling system with the medium range of cooling capacity (15RT level). Effect of absorption cooling system parameters, such as concentration difference, inlet temperature of cooling water, 1st generator temperature, leaving temperature differences of condenser and evaporator and efficiency of solution heat exchanger, has been investigated in the view of system cooling performance.

  • PDF

와류발생기의 충돌각과 루버각의 상호작용에 의한 열전달촉진 (Heat Transfer Enhancement by the Combined Effect of Louver Angle and Angle of Attack of Vertex Generator)

  • 박병규;정재동;이준식
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.477-484
    • /
    • 2002
  • A numerical investigation of the performance of the plate heat exchanger with rectangular winglet is conducted to examine the combined effect of vortex generator and louver fins. Velocity and temperature fields and spanwise averaged Nu and friction factor are presented. Enhancement of heat transfer and flow loss penalty is evident. A Parametric study of three factors (Re, angle of attack and louver angle) with levels of 5 (Re= 300, 500, 700, 900, 1100), 4($\alpha=15^{\circ}, 30^{\circ}, 45^{\circ}, 90^{\circ},$), and 4($\beta=0^{\circ}, 15^{\circ}, 30^{\circ}, 45^{\circ}$), respectively, indicates the performance defined by the ratio of heat transfer enhancement to flow loss penalty shows monotonic behavior for each parameter alone but the interactions between parameters is found to be considerable effect on the performance of heat exchanger and should be considered in design. The effect of stamping is also examined.

고층건물 피난계단에서의 연돌효과에 대한 현장실험 (Field Experiments on Stack Effect in Stairwells of High-Rise Building)

  • 김정엽
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.459-462
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The architectural factors affecting the pressure field of building should be examined for the successful design and operation of smoke management system and the stack effect is one of the important factors. The field experiments on stack effect in stairwells of high-rise building with regard to open/close condition of door are carried out to evaluate the features of pressure applied to door between each compartments, i.e, stair, lobby and accommodation. The procedures and results of experiments are presented.

  • PDF

바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향 (Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space)

  • 정광섭;한화택;홍승재
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

초고층 복합건축물 엘리베이터에서의 연돌현상 저감방안 평가 (Evaluation of the Alternatives to Minimize Stack Effect Problems with Elevators in Tall Complex Buildings)

  • 유정연;송규동;조동우
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.118-125
    • /
    • 2009
  • The purpose of this study is to evaluate the stack effect reduction alternatives in tall complex buildings in cold climates. The main problems in tall buildings occur in elevators. Such problems as elevator doors that do not close and exhaust airflows result in excessive pressure differences across elevator doors due to stack effect. Under the expected conditions causing these pressure differences, Field measurements are performed in three tall buildings. Each result of the measurements is analyzed in architectural design aspects. With these analysis, building design guidelines are proposed and analyzed by field measurements and computer simulations.

건축물 계단에서의 연돌효과 저감방안에 대한 3차원 수치해석 연구 (Study on 3D Numerical Analysis of Stack Effect Reduction in Stairwell of Building)

  • 김정엽;김지석
    • 설비공학논문집
    • /
    • 제27권3호
    • /
    • pp.152-157
    • /
    • 2015
  • Stack effect on high-rise building have negative effect on living environment, energy and life-safety aspect. Thus, it's necessary to find the measure to reduce the stack effect. As a result of field test on a 31-story building, a circulating type stack effect reduction technology was developed, which supplies air in the low stairs and discharges air in the high stairs. To evaluate the performance of this circulating type stack effect reduction technology on building stairs, a 3D numerical analysis was carried out by using Momentum Loss Model for analyzing leakage flow between compartments in a building. Consequently, numerical analysis proved that the stack effect on building stairs was reduced by a circulating type stack effect reduction technology.

Thermal Comfort Condition of Temperature and Humidity in Loess Interior Space

  • Kong, Sung-Hoon
    • 대한의생명과학회지
    • /
    • 제10권2호
    • /
    • pp.129-135
    • /
    • 2004
  • The study was carried out through measuring the temperature and humidity of the indoor/outdoor space and the distribution of interior thermal condition, and investigating the effect of loess materials on human body. The purpose of this study is to analyze the change of dry bulb temperature and relative humidity and correlation of thermal reaction of human body with ASHRAE (American Society of Heating, Refrigerating and Air-conditioning) comfort chart in the loess interior space. In the view point of biomedical sciences, loess interior space provides optimum thermal conditions for human thermal sensation.

  • PDF