• 제목/요약/키워드: Refrigerant Pressure Drop

검색결과 188건 처리시간 0.024초

냉동기 펌프다운 운전성능에 관한 연구 (A Study on Pump Down Operation Performance of Refrigerator)

  • 김철수;정한식;정효민
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.964-970
    • /
    • 2006
  • Vapor compression refrigerators have much critical variables such as the controls of temperature and pressure switches, control durations and operating hours of electronic valves. This study compares and analyzes the data which is obtained from system controlling of the evaporation temperatures which are generally used in automatic pump down operating systems. Through this study, the automatic evaporation control operation system will be more ideal for the system to keep the proper temperature distribution depending on the purpose of evaporation side. The automatic pump down control operation is more appropriate for the system to aim at the effective use of evaporation side without using the temperature difference. And this test will be proved that the changes at the low pressure side didn't have significant impacts on the high pressure side.

판형열교환기에서 R-22 냉매의 이상 압력 손실계수 평가 (Experimental measurements of R-22 two-phase friction factor in plate heat exchangers)

  • 유상훈;정지환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2273-2278
    • /
    • 2007
  • Brazed Plate Heat Exchanger (BPHE) is a type of compact plate heat exchanger with parallel corrugated plates which are brazed together in series. Each plate hascorrugation called herringbone pattern. Inside a BPHE, hot fluid and cold fluid alternate its flow direction to establish counter current flow configuration. Two-phase flow heat transfer and pressure drop of R-22 in BPHE were experimentally measured in this study. In the present experiments, single-phase region and two-phase region coexist in a BPHE. Therefore, the inside of a BPHE have to be divided into single phase region and two phase region and analyzed accordingly. The results from the single phase flow analysis are then extended to the two phase flow analysis to correlate the condensation and evaporation heat transfer and pressure drop for the refrigerant R-22 in the BPHEs. Previous models for two- phase friction factor have been compared with the present experimental results.

  • PDF

용접식 판형 열교환기의 성능에 관한 실험적 연구 (Experimental study on the performance of a brazed plate heat exchanger)

  • 김종하;윤재호;권오경;김종훈;류해성;이창식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.477-482
    • /
    • 2001
  • An experimental study on the performance evaluation of a brazed plate heat-exchanger with 10RT of normal cooling capacity has been carried out. In the present study, a brazed type plate heat exchanger was tested at a chevron angle $25^{\circ}$ with refrigerant R-22. Mass flux was ranged from $23\;to\;58kg/m^{2}s$ in condensation, and from $22\;to\;53kg/m^{2}s$ in evaporation. The heat transfer coefficient and pressure drop increased with the mass flux increases. The water side pressure drop increased with the cooling water flow rate and chilled water flow rate increases, while mass flux has little affect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

  • PDF

사이클론 방식 유분리기의 출구 튜브 설계 (Design of the Outlet-Port Tube of a Cyclone-Type Oil Separator for a Compressor)

  • 장성일;안준
    • 설비공학논문집
    • /
    • 제27권8호
    • /
    • pp.402-408
    • /
    • 2015
  • A series of numerical simulations have been carried out to study the performances of cyclone-type oil separators, which are designed for refrigeration-system compressors. The corresponding working fluid is R22, which is a typical refrigerant, whereby a mineral-oil droplet is supplied (Ed-highlight-My interpretation). The outlet-tube length in relation to the total chamber volume is considered a design parameter. Depending on the tube length, the separation efficiency varies from 98.7% to 99.3%, while the predicted pressure drop is between 5.1 kPa and 6.4 kPa. Considering both the pressure drop and separation efficiency, the length of the outlet-port tube of the separator is 152 mm.

수평평활 세관 내에서의 R-290, R-600a, R-22의 응축열전달과 압력강하 특성 (Condensation Heat Transfer Characteristics and Pressure Drop of R-290, R-600a, and R-22 in Horizontal Smooth Pipes with a Small Diameter)

  • 노건상;손창효
    • 청정기술
    • /
    • 제14권1호
    • /
    • pp.53-60
    • /
    • 2008
  • 본 연구에서는 내경이 각각 5.80 mm와 10.07 mm인 두 개의 수평 이중관열교환기 내에서의 탄화수소계 냉매의 응축열전달과 압력강하에 대한 실험을 $35.5{\sim}210.4\;kg/m^2\;s$의 질량유속과 응축온도인 $40^{\circ}C$에서 수행하였다. 탄화수소계 냉매 R-290과 R-600a의 응축열전달계수가 프레온계 냉매인 R-22보다 높았다. 응축압력강하는 R-600a > R-290 > R-22 순으로 나타났고, 내경이 5.8 mm인 관 내 보다 10.07 mm인 관 내의 압력강하가 R-600a에서는 $6{\sim}15%$ 정도 높았으며, R-290과 R-22에서는 각각 $9.8{\sim}12.5%$$2.1{\sim}4.6%$ 정도 높게 나타났다. 실험으로 구한 응축열전달계수와 종래의 상관관계식을 비교해 본 결과, 모든 관경에 대해 Haraguchi 등의 상관관계식과 가장 좋은 일치를 보였다.

  • PDF

수평미세관의 직경이 R-22 및 R-407C 비등열전달에 미치는 영향 (Effect on Boiling Bleat Transfer of Horizontal Micro-channel Diameters for R-22 and R-407C)

  • 윤국영;최광일;오종택
    • 대한기계학회논문집B
    • /
    • 제27권2호
    • /
    • pp.163-172
    • /
    • 2003
  • Boiling heat transfer coefficients and pressure drops for R-22 and R-407C were measured in horizontal micro-channels. The test section is stainless steel tube, inner tube diameters are 1.8mm and 2.8mm, and the respective lengths are 1500mm and 3000mm. The range of mass flux is 300-600kg/$m^2$s and heat flux is 5-15kW/$m^2$. In this results, pressure drop increased linearly for both R-22 and R-407C with increased mass flux, but the increase of heat flux did not affect the pressure. In addition, the pressure drop was fairly increased in the high quality region rather than low quality region. In the range of low quality, the mass flux had a small affect on the heat transfer coefficients, however, in high quality region, the heat transfer coefficients increased even more with increasing mass flux. Under the low quality region and low mass flux, the heat transfer coefficients increased with increasing heat flux densities. The effects of inner tube diameter were clearly observed. Namely, the measured pressure drop inside inner tube diameter 1.8 mm is higher than 2.8 mm with increasing the mass flux and heat flux. Also, the measured local heat transfer coefficient inside inner tube diameter 1.8 mm is higher than 2.8 mm in the range of high qualities. The experimental data for R-407C compared with proposed correlation using pure refrigerant. The experimental data for R-407C was more decreased than the proposed correlation for pure refrigerant up to 50% or more.

프로판/이소부탄(R-290/R-600a) 혼합 냉매를 적용한 가정용 소형 멀티 냉동시스템의 성능특성에 관한 연구 (A Study on Performance Characteristics of Propane/Isobutane Refrigerant Mixtures in a Domestic Small Multi-Refrigeration System)

  • 김상욱;이무연
    • 대한기계학회논문집B
    • /
    • 제29권2호
    • /
    • pp.271-278
    • /
    • 2005
  • In this paper, the performance of Kim-chi refrigerator with three evaporator and one compressor was investigated in employing $55\%$ propane and $45\%$ isobutane (R290/R600a) refrigerant mixture as an alternative refrigerant of R134a. The drop-in test was performed by varying both refrigerant charge and capillary tube length in order to find both the performance and reliability of a small multi-refrigeration system. Results show that the power consumption is decreased by about $15\%$ and COP is increased by about $10\%$, respectively as compared to the baseline system using R-134a. In addition, the propane/isobutane refrigerant mixture system took advantage of the minimization of modification and redesigning of system components because thermodynamic properties such as saturation pressure, temperature, normal boiling point(NBP) characteristics are similar to those of R134a. The reduction of sales cost is caused by the decrease of refrigerant cost per unit mass and refrigerant charge amount necessary for the refrigeration system.

프로판-이소부탄 혼합냉매를 적용한 소형 냉동시스템의 성능 특성에 관한 연구 (Performance Characteristics of Propane/isobutane Mixtures in a Small Refrigeration System)

  • 윤원재;김용찬
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.73-82
    • /
    • 2002
  • A small refrigeration system used in a water purifier was tested by employing propane/isobutane (R-290/R-6OOa) mixtures as an alternative refrigerant of R-12. The drop-in tests were performed by varying mass fraction of propane at 0.25, 0.5 and 0.75 with a change of both refrigerant charge amount and capillary tube length in order to find an optimum composition in aspect of performance and reliability of the system. As a result, the mixture of 50% propane-50% isobutane showed the best performance and reliability among them in a small refrigeration system. During steady state operations, both the COP and refrigeration capacity increased by 4% and 9%, respectively, as compared to the baseline R-12 system. In addition, the propane/isobutane (50/50) mixture system yielded advantages in the minimization of modification and redesigning of system components due to very similar saturation tempera- ture and pressure characteristics with R-12.

내경 4.55 mm의 경사진 헬리컬 코일형 열교환기내 이산화탄소의 열전달 특성에 관한 연구 (Heat Transfer Characteristics of Carbon Dioxide in a Inclined Helical Coil Type Heat Exchanger with Inner Diameter Tube of 4.55 mm)

  • 손창효
    • 한국가스학회지
    • /
    • 제11권3호
    • /
    • pp.1-6
    • /
    • 2007
  • 본 연구에서는 경사진 헬리컬 코일형 동관내 이산화탄소의 증발 열전달 계수와 압력강하를 실험적으로 조사하였다. 냉매 순환루프의 주요구성품은 수액기, 변속펌프, 질량유량계, 예열기, 경사진 헬리컬 코일형 가스냉각기(시험부)로 구성된다. 시험부는 내경 4.55 mm의 평활 동관으로 이루어져 있다. 냉매질량 유속은 $200kg/m^2s$에서 $600kg/m^2s$까지 변화시켰고, 가스냉각기의 입구압력은 7.5 MPa에서 10.0 MPa까지이다. 경사진 헬리컬 코일관내 이산화탄소의 열전달 계수는 질량유속과 냉각압력의 증가와 함께 따라 증가하였다. 이산화탄소의 압력강하는 헬리컬 코일관내 단상 상관식인 Ito식과 좋은 일치를 보였고, 이산화탄소의 국소 열전달 계수는 Pilta 등이 제안한 상관식과 좋은 일치를 보였다. 하지만, 유사임계 온도 영역부근에서는 실험데이터가 더 높게 나타났다.

  • PDF

불균일 공기분포와 관의 종류에 따른 핀-관 응축기의 성능 특성에 관한 해석적 연구 (Numerical Study on the Performance of a Fin-and-Tube Condenser with Non-Uniform Air Distribution and Different Tube Types)

  • 조다영;함형창;박창용
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.858-866
    • /
    • 2012
  • A numerical study was performed to predict the performance of a fin-and-tube condenser. A condenser model was developed and verified by comparing the simulation results with experimental data for a R410A condenser in a residential air-conditioning system. The prediction error was 0.07% and -5.77% for the condenser capacity and pressure drop, respectively. In simulation results, the capacity and pressure drop of the condenser with even air velocity distribution were 0.67% and 12.93% higher than those with uneven distribution of air velocity. It was predicted by the model that the refrigerant distribution at the condenser inlet to the two first passes was not significantly influenced by the air distribution. The simulation results presented that the 1.49% of capacity and 64.6% of pressure drop were reduced by replacing helical microfin tubes with smooth tubes for the condenser.