• 제목/요약/키워드: Reference standard

검색결과 2,185건 처리시간 0.028초

Benzo[a]pyrene 분석용 토양 숙련도 표준시료 개발에 관한 연구 - 후보 표준물질의 인증을 위한 균질성, 안정성 평가를 중심으로 - (A Study on the Development of Soil-based PTMs for Analysis of Benzo[a]pyrene - Focusing on the Evaluation of Homogeneity and Stability for the Certification of Benzo[a]pyrenecandidate Reference Materials -)

  • 이민효;이군택;주창규;김용훈;이법열;최성헌;김명옥;홍석영;김금희;이원석
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권6호
    • /
    • pp.49-58
    • /
    • 2014
  • This study was implemented as a part of the experiment to develop two kinds of soil-based Benzo[a]pyrene (BaP) proficiency testing materials (PTMs) for soil analysis. A test was carried out for the check of solubility of the reference material (high purity reagent) using several solvents. Another test was also conducted for the evaluation of homogeneity and stability of two kinds of candidate soil reference materials. The test analysis of BaP in terms of the candidate materials was conducted according to the Standard Soil Analytical Methods by Ministry of Environment. Dissolution of the reference material was shown to vary depending on solvent type and was higher in the order of Dichloromethane > Acetone > Acetone/MeOH (9 : 1) > N-hexane. In addition, the slope on calibration curve for BaP standard solutions was largest on BaP standard solutions prepared with dichloromethane of the tested solvents. Such tendency appeared egually in the commercial BaP standard solution. Therefore, it is thought to be reasonable to use dichloromethane as the solvent in case of the standard stock solution that is used for the measurement of BaP concentration in soil. ISO 13528 and IUPAC protocol were used for verification of homogeneity on the two kinds of soil candidate materials, Both candidate materials were sufficiently homogeneous. Stability assessment of the two candidate materials was made according to ISO Guide 35 and the result showed that both batches did not have any long-term and short term stability issues that might occur during shipping. However, monitoring results of BaP concentration in soil showed that BaP concentration of the two batches measured at 15 days after the sample preparation was reduced by about 24~37% compared with that of the samples measured on 0 day of the sample preparation. Identification was done with several treatments such as irradiation and sterilization etc. The major cause was shown to be irradiation to the samples.

진단검사의학 검체검사의 정상치와 참고치

  • 이갑노
    • 한국건강관리협회지
    • /
    • 제1권1호
    • /
    • pp.19-20
    • /
    • 2003
  • In Korea association of health promotion(KHAP) there are fourteen laboratories in branch offices and one laboratory in headquarter office. To standardize the reference ranges of all laboratories of KAHP, they have been newly calculated from the laboratory data perfomed during the previous yearsby statistical metod annually for the period of 2000 through2003 so far. The referance ranges of total 56 test items were assigned. Among these there were eight test items that needed referance ranges by age groups and nine test items that needed reference rages by gender. The age grouping was into six groups : baby (0-3y), children(4-12y), adolescent(13-18y), adult(19-64y), younger elderly(19-64y), older elderly(over 80y) with references of statics in Medical Informatics and WHO classification. All the data collected were statistically analyzed with SAS 6.04 for Gaussian distribution that had been repeated two or three times after trimming out the the tests showed Gaussian distribution. Subsequently, Thereference ranges were defined in the rage from the point of lower 2.5% to the point of higher 97.5%. And in case the lower range could be "0", the reference ranges were defined in the range of 0 to 95%. Fifteen laboratoried troughout Korea of KAHP currently have standarzed reference rages of the tests that they perform. This means the patient data and reference values an be exchangeable among laboratories of KHAP.Annual revise of such reference rages can eventually lead to the level of those representing a standard of the national reference ranges.

  • PDF

전자게시판을 이용한 대학도서관의 참고정보저비스에 관한 연구 -자유게시판, Q&A, FAQ, 참고질의응답을 중심으로- (A Study on the Electronic Reference Services Using Electronic Bulletin Boards in University Libraries)

  • 이명희;이미영
    • 한국비블리아학회지
    • /
    • 제14권2호
    • /
    • pp.159-178
    • /
    • 2003
  • 본 연구는 대학도서관에서 제공하는 전자게시판 중 자유게시판, Q&A, FAQ, 참고질의 응답의 4가지 유형의 참고서비스를 대상으로 게재되는 질문의 유형과 내용을 분석함으로써 서비스 유형별 특성을 조사하고 이용자의 정보요구를 파악하였다. 분석한 결과, 4가지 서비스의 유형에 따라 질문유형별 차이를 발견하지 못하였다. 모든 서비스에서 안내형 질문이 가장 많았으며, 주제형 질문은 미미한 것으로 나타났다. 분석결과를 토대로 4가지 유형별 서비스에 대한 발전방안을 제시하였다: 서비스 유형에 대한 메뉴명칭의 표준화, 서비스 접근이 용이한 메뉴 배치, 각 서비스에 적합한 성격 명시, 내용검색기능과 응답기능을 첨가하는 구조개선, 질문작성 양식의 제안, 전자참고서비스의 전담부서 및 전담자배치, 정책마련, 홍보강화를 제안하였다.

  • PDF

공급사슬 협업을 위한 참조모델 기반의 프레임워크 (A Reference Model Based Framework for Supply Chain Collaboration)

  • 최영환;채희권;김광수
    • 대한산업공학회지
    • /
    • 제31권2호
    • /
    • pp.152-163
    • /
    • 2005
  • The focus of enterprise collaboration of supply chain management, has changed from integrating and exchanging business information to integrating and managing business processes between business partners. However, the collaboration is difficult due to the inherent complexity such as diverse business processes and dynamic business environments. To settle these problems, a reference model based enterprise architecture framework for the collaboration of supply chains is proposed in this paper. The supply chain collaboration framework is composed of three reference models capturing the different views of supply chain collaboration: supply process reference model, service component reference model, and technology and standard reference model. As the framework adapts the OMG's metadata architecture, the processes in the supply chain can be extended and integrated with other value chains, such as design chains, when it is necessary. Using the proposed framework, business managers can rapidly integrate and manage their business processes with their suppliers and customers.

GPS 상시 관측망에서 산정된 가상기준점 자료의 정확도 분석 (Accuracy Analysis of Virtual Reference Station's Data by GPS Continuous Reference Station's Network)

  • 이용창
    • 대한공간정보학회지
    • /
    • 제12권1호
    • /
    • pp.55-62
    • /
    • 2004
  • 최근 들어 높은 정밀도를 요하는 여러 GPS 응용분야에서 표준 RTK 기법의 적용거리 제한의 극복 방안으로 다수의 GPS 상시관측소를 활용한 RTK 기법(VRS ; 가상기준점방식)이 세계적으로 주목받고 있다. 이동국의 측위 정밀도는 가상기준점의 정밀도와 긴밀한 연관관계가 있다. 본 연구에서는 사후처리방식으로 시험망에서 가상점의 측위정확도와 기준점으로서의 기능을 고찰하는데 목적을 두고 후처리 방식으로 시험망 영역 내외에 가상 기준점을 생성한 후, 기존의 GPS 기준점을 고정시켜 해석한 결과와 가상점 생성 시의 실제좌표를 비교 고찰하였다. 연구결과. 사후처리 VRS 방식으로 시험망에서 생성한 가상점의 정확도를 확인할 수 있었다.

  • PDF

Standard sand for geotechnical engineering and geoenvironmental research in Nigeria: Igbokoda sand

  • Ojuri, Oluwapelumi O.;Fijabia, David O.
    • Advances in environmental research
    • /
    • 제1권4호
    • /
    • pp.305-321
    • /
    • 2012
  • This study entails establishing reference standard sand in Nigeria for engineering and geoenvironmental research work. Sands from four geographical locations in southwestern Nigeria were examined for baseline geotechnical and mineralogical properties. A total of sixteen sand samples were collected. The samples were air dried and subjected to tests in accordance with standard specifications. The tests carried out were: specific gravity, grain size analysis, moisture content, bulk density, porosity, void ratio, chemical analysis, X-ray diffraction and Differential Thermal Analysis. The properties of the samples were compared with a standard (Ottawa sand in Illinois of the United States) in order to find out which of the four samples selected from southwestern Nigeria could serve as standard baseline sand. The results show that Igbokoda sand has geotechnical and mineralogical characteristics closest to Ottawa sand. It was therefore concluded that Igbokoda sand could be used as a standard baseline sand for research work in southwestern Nigeria and other parts of Nigeria since it needs little processing to bring it to the same level as standard baseline sand, like the Ottawa sand.

인증표준물질(CRM)을 이용한 소변 중 대마 대사체 분석법 평가 (Analysis of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in urine with certified reference material)

  • 고범준;김진영;김종상;이정직;정재철;서승일;인문교
    • 분석과학
    • /
    • 제23권1호
    • /
    • pp.83-88
    • /
    • 2010
  • 대검찰청 마약감식실은 대마 흡연여부를 판별하는 수단인 소변 중 대마 대사체 성분 분석법 에 대한 신뢰도 평가를 위하여 인증표준물질을 이용한 시험을 실시하였다. 시험에 사용된 인증표준물질은 미국 NIST에서 판매하는 Standard Reference Material 1507b로, 11-nor-${\Delta}^9$-tetrahydrocannabinol-9-carboxylic acid (THCCOOH)가 함유된 냉동 건조 소변이었다. NIST에서 구매한 인증표준물질의 농도값과 실험실에서 측정한 농도값을 비교 평가해 본 결과, 약 95% 신뢰수준에서 일치하였다.

한국원자력연구소 기준 광자 및 베타선장 측정의 국제상호비교 (Intercomparison of the KAERI Reference Photon and Beta Radiation Measurements)

  • 장시영;김봉환;김장렬
    • Journal of Radiation Protection and Research
    • /
    • 제21권4호
    • /
    • pp.255-262
    • /
    • 1996
  • 이 논문은 최근 한국원자력연구소(KAERI)와 미국 패시픽노스웨스트 국립연구소(일명, 바텔연구소, PNNL)이 개인선량계의 성능검사를 위한 미국 ANSI N13.11 기준에 근거하여 KAERI 방사선 측정/교정실험실에서 수행한 KAERI 기준 광자 및 베타 방사선장의 국제 상호비교 측정결과를 설명하고 있다. 두 기관이 각각 자국의 일차 표준에 소급성을 갖는 방사선 검출기와 방사선 측정장치를 사용하여 자유공기중에서 광자의 조사선량(율), 공기커마(율)와 베타선의 절대 흡수선량(율)을 측정한 결과, 광자선장에 대해서는 ${\pm}2.0%$을 베타선장에 대해서는${\pm}1.0%$의 오차범위 내에서 잘 일치하였다. 따라서 KAERI의 기준 광자 및 베타 방사선장은 국제표준에 잘 만족되고 있음이 입증되었으며 장차 방사선 도시메트리 연구개발의 국가 기술기반으로 활용될 수 있음이 확인되었다

  • PDF

시험선원을 이용한 기준 전리함의 감도변화와 임상필드전리함의 성능 안정성 비교 (Comparison the reference ion chamber in using the radioactive check source and field ion chamber for output dose for Co-60 source of remote afterloading system)

  • 최태진
    • 한국의학물리학회지:의학물리
    • /
    • 제12권2호
    • /
    • pp.141-146
    • /
    • 2001
  • 치료효과를 보증하기 위해서는 조사선량의 5% 이내의 선량오차가 방사선생물학적 의미가 높은 것으로 잘 알려져 있다. 따라서 종양치료를 위한 강내조사 선원이나 선형가속기의 고선량율의 선량 평가는 정확하고 안정적 평가가 이루어져야 된다. 선량을 평가 교정하기 위해 전리함의 교정 인정기관의 교정상수를 유지하기 위해 선진국에서는 기하학적으로 고정된 표준선원과 전리함의 사용을 오래 전부터 권고해 왔다. 본 연구는 전리함의 감도 변화를 측정할 수 있는 Sr-90 시험선원을 이용한 임의의 기준 전리함의장기간 안정성이 1.00$\pm$0.01 의 오차 범위에 있음을 알 수 있었고, 고선량률 원격강내조사선원인 Co-60 선원에 대한 기준전리함의 출력선량에 대한 임상측정용 전리함의 출력선량은 평균 0.997 $\pm$ 0.01의 오차범위에서 평가될 수 있었으며, 최대오차는 예상선량에 -2.5% 였다. 이 실험을 통해 반감기가 긴 시험선원을 이용하여 임상 측정용 공기전리함의 안정적 성능을 유지할 수 있음을 알 수 있다.

  • PDF

곡률보상 기능을 갖는 0.35㎛ CMOS 저전압 기준전류/전압 발생회로 (0.35㎛ CMOS Low-Voltage Current/Voltage Reference Circuits with Curvature Compensation)

  • 박은영;최범관;양희준;윤은정;유종근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.527-530
    • /
    • 2016
  • 본 논문에서는 $0.35-{\mu}m$ standard CMOS 공정에서 낮은 전력을 소모하면서 낮은 전원전압에서 동작하는 곡률보상 기능을 갖는 기준전류/전압 발생 회로를 제안한다. 제안된 회로는 weak-inversion 영역에서 동작하는 MOS 트랜지스터들을 사용함으로써 1V 이하 전원전압에서 동작할 수 있다. 시뮬레이션 결과는 제안되는 곡률보상 기술을 사용하여 기존의 곡률보상 기능이 없는 BGR 회로들처럼 종 모양이 아닌 사인 곡선과 같은 모양을 나타내 작은 TC 값을 보여준다. 제안된 회로들은 모두 0.9V의 전원전압에서 동작한다. 먼저, 기준전압 발생 회로는 176nW 전력을 소모하며, 온도 계수는 $26.4ppm/^{\circ}C$이다. 기준전류 발생 회로는 194.3nW 전력을 소모하며, 온도 계수는 $13.3ppm/^{\circ}C$이다.

  • PDF