• Title/Summary/Keyword: Reference set

Search Result 1,204, Processing Time 0.032 seconds

Function of the Korean String Indexing System for the Subject Catalog (주제목록을 위한 한국용어열색인 시스템의 기능)

  • Yoon Kooho
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.15
    • /
    • pp.225-266
    • /
    • 1988
  • Various theories and techniques for the subject catalog have been developed since Charles Ammi Cutter first tried to formulate rules for the construction of subject headings in 1876. However, they do not seem to be appropriate to Korean language because the syntax and semantics of Korean language are different from those of English and other European languages. This study therefore attempts to develop a new Korean subject indexing system, namely Korean String Indexing System(KOSIS), in order to increase the use of subject catalogs. For this purpose, advantages and disadvantages between the classed subject catalog nd the alphabetical subject catalog, which are typical subject ca-alogs in libraries, are investigated, and most of remarkable subject indexing systems, in particular the PRECIS developed by the British National Bibliography, are reviewed and analysed. KOSIS is a string indexing based on purely the syntax and semantics of Korean language, even though considerable principles of PRECIS are applied to it. The outlines of KOSIS are as follows: 1) KOSIS is based on the fundamentals of natural language and an ingenious conjunction of human indexing skills and computer capabilities. 2) KOSIS is. 3 string indexing based on the 'principle of context-dependency.' A string of terms organized accoding to his principle shows remarkable affinity with certain patterns of words in ordinary discourse. From that point onward, natural language rather than classificatory terms become the basic model for indexing schemes. 3) KOSIS uses 24 role operators. One or more operators should be allocated to the index string, which is organized manually by the indexer's intellectual work, in order to establish the most explicit syntactic relationship of index terms. 4) Traditionally, a single -line entry format is used in which a subject heading or index entry is presented as a single sequence of words, consisting of the entry terms, plus, in some cases, an extra qualifying term or phrase. But KOSIS employs a two-line entry format which contains three basic positions for the production of index entries. The 'lead' serves as the user's access point, the 'display' contains those terms which are themselves context dependent on the lead, 'qualifier' sets the lead term into its wider context. 5) Each of the KOSIS entries is co-extensive with the initial subject statement prepared by the indexer, since it displays all the subject specificities. Compound terms are always presented in their natural language order. Inverted headings are not produced in KOSIS. Consequently, the precision ratio of information retrieval can be increased. 6) KOSIS uses 5 relational codes for the system of references among semantically related terms. Semantically related terms are handled by a different set of routines, leading to the production of 'See' and 'See also' references. 7) KOSIS was riginally developed for a classified catalog system which requires a subject index, that is an index -which 'trans-lates' subject index, that is, an index which 'translates' subjects expressed in natural language into the appropriate classification numbers. However, KOSIS can also be us d for a dictionary catalog system. Accordingly, KOSIS strings can be manipulated to produce either appropriate subject indexes for a classified catalog system, or acceptable subject headings for a dictionary catalog system. 8) KOSIS is able to maintain a constistency of index entries and cross references by means of a routine identification of the established index strings and reference system. For this purpose, an individual Subject Indicator Number and Reference Indicator Number is allocated to each new index strings and new index terms, respectively. can produce all the index entries, cross references, and authority cards by means of either manual or mechanical methods. Thus, detailed algorithms for the machine-production of various outputs are provided for the institutions which can use computer facilities.

  • PDF

Evaluation of difference in respiratory phase between amplitude- and phase-based four-dimensional computed tomography (위상 기반 사차원전산화단층촬영과 진폭 기반 사차원전산화단층촬영 영상에서의 위상차 평가)

  • Lee, So Hyang;Park, Soo Yeon;Kim, Jong Sik;Choi, Byung Ki;Park, Hee Chul;Jung, Sang Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.73-78
    • /
    • 2015
  • Purpose : Under the assumption of change to the amplitude based sorting, the study will use four dimensional computed tomography imaging (4DCT) arrayed using the phase based sorting to analyze the respiratory phase difference. Materials and Methods : The study analyzed the 4DCT (4-dimensional computed tomography) images of 10 liver cancer patients that were treated with respiratory gated radiotherapy from 2015 February to March. Using RPM respiratory gating (RPM 1.7.5, Varian, USA) equipment, imaging according to respiratory cycle of phase based sorting was acquired and using a treatment planning system (Pinnacle 9.2, Philips, USA) the acquired imaging according to respiratory cycle was used to measure the abdominal movement value by respiratory cycle. The measuring point was the point where the center point of the Marker Block and the body surface met in the 50% phase image and here the coordinate values Lateral, Vertical, Longitudinal (X, Y, Z) were set as reference points, and on the X, Z plane identical to the reference point, using the identical method the Y axis coordinate value of each 0%, 30%, 40%, 50%, 60%, 80% phase images were acquired to quantitatively measure the variation of distance to the Y axis. The abdominal movement value according to respiration was applied to the theoretical model that the value decreases linearly from maximum inhalation to maximum exhalation to divide the variation of my value to predict as amplitude value by respiratory cycle and conversely the variation in amplitude was recalculated with the phase variation deviation value to analyze. Results : The deviation value between expected value and actual location was the largest in the 30% phase with 0.24 cm, and standard deviation was also the largest in 30% phase with 0.13 cm. The effective value of the deviation value derived from the average of the deviation squared value of each patient appeared as minimum 0.7 cm, maximum 0.18 cm, average 0.12 cm, and standard deviation 0.4 cm. Also by dividing the actual movement distance value with the peak expiration value then converting it into %Phase, the deviation value with actual phase 16.5% in 30% phase, 10.0% and 40% phase, 10.0% and 60% phase, 15.4% and 80% phase, and overall average about 13%, and arraying based on amplitude, phase shift occurred and further it was from peak expiration the chance of deviation occurrence was increasingly measured. Conclusion : Based on the results of the study there were differences between value acquired based on theoretical model and actual value. Therefore in respiratory gated radiotherapy using external surrogates, there needs to be establishment of respiration gated radiation system that avoids the combination of two Sorting methods considering that there will be occurrence of treatment and corresponding clinical differences due to the phase difference that occur due to the Amplitude based Phase Sorting.

  • PDF

Application of Chemiluminescence Enzyme Immunoassay Method to Collect in vivo Matured Oocyte in Dog Cloning (개 복제 시 체내 성숙 난자 회수를 위한 화학발광효소면역분석기법의 적용)

  • Kim, Min-Jung;Oh, Hyun-Ju;Kim, Geon-A;Jo, Young-Kwang;Choi, Jin;Lee, Byeong-Chun
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.267-271
    • /
    • 2014
  • Accurate determination of in vivo oocyte maturation is particularly critical for dog cloning compared to other assisted reproductive technologies because oocytes in metaphase II stage have to be recovered in order to undergo somatic cell nuclear transfer right after its recovery. The aim of present study was to evaluate the reliability and to set a reference range of a chemiluminescence enzyme immunoassay (CLEIA) compared to radioimmunoassay (RIA) method to retrieve in vivo matured oocytes. Serum progesterone concentration during proestrus and estrus was analyzed by RIA and CLEIA to determine ovulation day (Day 0). On Day 3, in vivo oocytes were recovered surgically and evaluated microscopically maturation status after staining nucleus with bisbenzimidazole dye. Mean progesterone concentration by CLEIA ($7.64{\pm}0.06ng/ml$) was significantly higher than by RIA ($6.46{\pm}0.04ng/ml$, P < 0.0001). It was not different between CLEIA ($10.01{\pm}0.34ng/ml$) and RIA values ($7.91{\pm}0.14ng/ml$, P < 0.05) on Day 0, but significantly higher CLEIA level on Day -1 and Day 1 ($6.41{\pm}0.15$ and $14.25{\pm}0.44ng/ml$) was assessed compared to RIA ($4.95{\pm}0.10$ and $11.29{\pm}0.34ng/ml$). However, with both methods, progesterone level was significantly increased from Day -1 to Day 2. To determine oocyte maturation with CLEIA method, a wider and higher reference range has to be considered.

A Case Study of Elementary Students' Developmental Pathway of Spatial Reasoning on Earth Revolution and Apparent Motion of Constellations (지구의 공전과 별자리의 겉보기 운동에 대한 초등학생들의 공간적 추론 발달 경로의 사례 연구)

  • Maeng, Seungho;Lee, Kiyoung
    • Journal of The Korean Association For Science Education
    • /
    • v.38 no.4
    • /
    • pp.481-494
    • /
    • 2018
  • This study investigated elementary students' understanding of Earth revolution and its accompanied apparent motion of constellation in terms of spatial reasoning. We designed a set of multi-tiered constructed response items in which students described their own idea about the reason of consecutive movement of constellations for three months and drew a diagram about relative locations of the Sun, the Earth, and the constellations. Sixty-five sixth grade students from four elementary schools participated in the tests both before and after science classes on the relative movement of Earth and Moon. Their answers to the items were categorized inductively in terms of transforming frames of reference which are observed on the Earth and designed from the Space-based perspective. We analyzed those categories by the levels of spatial reasoning and depicted the change of students' levels between pre/post-tests so that we could get an idea on the preliminary developmental pathway of students' understanding of this topic. The lower anchor description was that constellations move around the Earth with geocentric perspective. Intermediate level descriptions were planar understanding of Earth movement, intuitive idea on constellation movement along with the Earth. Students with intermediate levels did not reach understanding of the apparent motion of constellations. As the upper anchor description students understood the apparent motion of constellations according to the Earth revolution and could transform their frames of reference between Earth-based view and Space-based view. The features as the case of evolutionary learning progressions and critical points of students' development for this topic were discussed.

Evaluating efficiency of automatic surface irrigation for soybean production

  • Jung, Ki-yuol;Lee, Sang-hun;Chun, Hyen-chung;Choi, Young-dae;Kang, Hang-won
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.252-252
    • /
    • 2017
  • Nowadays water shortage is becoming one of the biggest problems in the Korea. Many different methods are developed for conservation of water. Soil water management has become the most indispensable factor for augmenting the crop productivity especially on soybean (Glycine max L.) because of their high susceptibility to both water stress and water logging at various growth stages. The farmers have been using irrigation techniques through manual control which farmers irrigate lands at regular intervals. Automatic irrigation systems are convenient, especially for those who need to travel. If automatic irrigation systems are installed and programmed properly, they can even save you money and help in water conservation. Automatic irrigation systems can be programmed to provide automatic irrigation to the plants which helps in saving money and water and to discharge more precise amounts of water in a targeted area, which promotes water conservation. The objective of this study was to determine the possible effect of automatic irrigation systems based on soil moisture on soybean growth. This experiment was conducted on an upland field with sandy loam soils in Department of Southern Area Crop, NICS, RDA. The study had three different irrigation methods; sprinkle irrigation (SI), surface drip irrigation (SDI) and fountain irrigation (FI). SI was installed at spacing of $7{\times}7m$ and $1.8m^3/hr$ as square for per irrigation plot, a lateral pipe of SDI was laid down to 1.2 m row spacing with $2.3L\;h^{-1}$ discharge rate, the distance between laterals was 20 cm spacing between drippers and FI was laid down in 3m interval as square for per irrigation plot. Soybean (Daewon) cultivar was sown in the June $20^{th}$, 2016, planted in 2 rows of apart in 1.2 m wide rows and distance between hills was 20 cm. All agronomic practices were done as the recommended cultivation. This automatic irrigation system had valves to turn irrigation on/off easily by automated controller, solenoids and moisture sensor which were set the reference level as available soil moisture levels of 30% at 10cm depth. The efficiency of applied irrigation was obtained by dividing the total water stored in the effective root zone to the applied irrigation water. Results showed that seasonal applied irrigation water amounts were $60.4ton\;10a^{-1}$ (SI), $47.3ton\;10a^{-1}$ (SDI) and $92.6 ton\;10a^{-1}$ (FI), respectively. The most significant advantage of SDI system was that water was supplied near the root zone of plants drip by drip. This system saved a large quantity of water by 27.5% and 95.6% compared to SI, FI system. The average soybean yield was significantly affected by different irrigation methods. The soybean yield by different irrigation methods were $309.7kg\;10a^{-1}$ from SDI $282.2kg\;10a^{-1}$ from SI, $289.4kg\;10a^{-1}$ from FI, and $206.3kg\;10a^{-1}$ from control, respectively. SDI resulted in increase of soybean yield by 50.1%, 7.0% 9.8% compared to non-irrigation (control), FI and SI, respectively. Therefore, the automatic irrigation system supplied water only when the soil moisture in the soil went below the reference. Due to the direct transfer of water to the roots water conservation took place and also helped to maintain the moisture to soil ratio at the root zone constant. Thus the system is efficient and compatible to changing environment. The automatic irrigation system provides with several benefits and can operate with less manpower. In conclusion, improving automatic irrigation system can contribute greatly to reducing production costs of crops and making the industry more competitive and sustainable.

  • PDF

Method of Elastic Constant Measurement for Transversely Isotropic Rocks: Application to Banded Gneiss of the Onyang Region (온양지역에 분포하는 호상편마암을 이용한 평면 이방성 암석의 탄성상수 측정방법)

  • Jang, Hyun-Sic;Lee, Ok-Top;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.22 no.3
    • /
    • pp.309-321
    • /
    • 2012
  • Elastic constants were measured for 70 samples of transversely isotropic banded gneiss from the Onyang region. Anisotropic angles of samples are $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $75^{\circ}$ and $90^{\circ}$. Exact values of $E_2$ and ${\nu}_{21}$ can be measured from samples with anisotropic angles of $0^{\circ}$ and those of $E_1$ and ${\nu}_{12}$ from samples with anisotropic angles of $90^{\circ}$. These values are set as reference values. Elastic constants measured from samples with anisotropic angles of $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, and $75^{\circ}$, using the methods proposed by Jang et al. (2001) and Park et al. (2008), are compared with the reference values to examine the effectiveness of the two methods. $E_1$ were measured correctly from samples with anisotropic angles of $60^{\circ}$ and $75^{\circ}$, and $E_2$ from samples with anisotropic angles of $15^{\circ}$ and $30^{\circ}$, when using the method suggested by Jang et al. (2001). $E_1$ were measured correctly from samples with anisotropic angles of $45^{\circ}$ and $60^{\circ}$, and $E_2$ from samples with anisotropic angles of $15^{\circ}$, $30^{\circ}$, and $60^{\circ}$, when using the method proposed by Park et al. (2008). The effectiveness of the two methods was determined by error rates between exact values and measured values. The effectiveness of the two methods was similar. However, the method suggested by Jang et al. (2001) may be more effective in measuring $E_1$, while the method suggested by Park et al. (2008) may be more effective in measuring $E_2$.

The Development of Air-kerma Strength Calculation Algorithm in Terms of the Absorbed Dose to Water for HDR Ir-192 Source (기준점에서의 물 흡수선량을 이용한 Ir-192 선원의 공기커마 세기 계산을 위한 알고리즘 개발)

  • Huh, Hyun-Do;Kim, Woo-Chul;Loh, John-Jk;Lee, Suk;Lee, Sang-Hoon;Cho, Sam-Ju;Shin, Dong-Oh;Choi, Jin-Ho;Kwon, Soo-Il;Kim, Seong-Hoon
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.232-237
    • /
    • 2006
  • The aim of this study was to develop the calculation algorithm of source strength of Ir-192 source In terms of the absorbed dose to water instead of an apparent activity (Ci). For this work the Multi Purpose Brachytherapy Phantom(MPBP) was developed, which was designed to locate the source and the chamber precisely at a specific position Inside the water phantom. The reference point of measurement was set at the 5 cm distance along the transverse axis of the source. For a brachytherapy source calibration, the absorbed dose to water calibration factor ($N_{D.W.Q}$) of an lonization chamber were determined and then apply standard protocols of absorbed dose to water. The calibration factor ($N_{D.W.Q}$) of the ion chamber (TM30013, PTW, Germany) was determined using the EGSnrcCPP Monte Carlo Code. The calculated calibration factor ($N_{D.W.Q}$) was 5.28 cGy/nC. The calculated factor was then used to determine the absorbed dose to water from which the air kerma strength for an Ir-192 source can be easily derived at the reference point (5 cm). The calculated air kerma strength showed discrepancies of -0.6% to +1.8% relative to the air kerma strength provided by the vendor, In this work we demonstrated that the air kerma strength ($S_k$) could be determined from the absorbed dose to water calibration factor for Ir-192 source. In audition, this source calibration method could be applied directly to the dose Calculation formalism of AAPM report TG-43.

  • PDF

Development of Acquisition and Analysis System of Radar Information for Small Inshore and Coastal Fishing Vessels - Suppression of Radar Clutter by CFAR - (연근해 소형 어선의 레이더 정보 수록 및 해석 시스템 개발 - CFAR에 의한 레이더 잡음 억제 -)

  • 이대재;김광식;신형일;변덕수
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.347-357
    • /
    • 2003
  • This paper describes on the suppression of sea clutter on marine radar display using a cell-averaging CFAR(constant false alarm rate) technique, and on the analysis of radar echo signal data in relation to the estimation of ARPA functions and the detection of the shadow effect in clutter returns. The echo signal was measured using a X -band radar, that is located on the Pukyong National University, with a horizontal beamwidth of $$3.9^{\circ}$$, a vertical beamwidth of $20^{\circ}$, pulsewidth of $0.8 {\mu}s$ and a transmitted peak power of 4 ㎾ The suppression performance of sea clutter was investigated for the probability of false alarm between $l0-^0.25;and; 10^-1.0$. Also the performance of cell averaging CFAR was compared with that of ideal fixed threshold. The motion vectors and trajectory of ships was extracted and the shadow effect in clutter returns was analyzed. The results obtained are summarized as follows;1. The ARPA plotting results and motion vectors for acquired targets extracted by analyzing the echo signal data were displayed on the PC based radar system and the continuous trajectory of ships was tracked in real time. 2. To suppress the sea clutter under noisy environment, a cell averaging CFAR processor having total CFAR window of 47 samples(20+20 reference cells, 3+3 guard cells and the cell under test) was designed. On a particular data set acquired at Suyong Man, Busan, Korea, when the probability of false alarm applied to the designed cell averaging CFAR processor was 10$^{-0}$.75/ the suppression performance of radar clutter was significantly improved. The results obtained suggest that the designed cell averaging CFAR processor was very effective in uniform clutter environments. 3. It is concluded that the cell averaging CF AR may be able to give a considerable improvement in suppression performance of uniform sea clutter compared to the ideal fixed threshold. 4. The effective height of target, that was estimated by analyzing the shadow effect in clutter returns for a number of range bins behind the target as seen from the radar antenna, was approximately 1.2 m and the information for this height can be used to extract the shape parameter of tracked target..

Repeatability and Reproducibility in Effective Porosity Measurements of Rock Samples (암석시험편 유효공극률 측정의 반복성과 재현성)

  • Lee, Tae Jong;Lee, Sang Kyu
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.209-218
    • /
    • 2012
  • Repeatability and reproducibility in solid weight and effective porosity measurements have been discussed using 8 core samples with different diameters, lengths, rock types, and effective porosities. Further, the effect of temperature on the effective porosity measurement has been discussed as well. Effective porosity of each sample has been measured 7 times with vacuum saturation method with vacuum pressure of 1 torr and vacuum time of 80 minutes. Firstly, effective porosity of each sample is measured one by one, so that it can provide a reference value. Then for reproducibility check, effective porosity measurements with vacuum saturation of 2, 4, and 8 samples simultaneously have been performed. And finally, repeated measurements for 3 times for each sample are made for repeatability check. Average deviation from the reference set in solid weight showed 0.00 $g/cm^3$, which means perfect repeatability and reproducibility. For effective porosity, average deviations are less than 0.07% and 0.05% in repeatability and reproducibility test sets, respectively, which are in good agreement too. Most of porosities measured in reproducibility test lies within the deviation range in repeatability test sets. Thus, simultaneous vacuum saturation of several samples has little impact on the effective porosity measurement when high vacuum pressure of 1 torr is used. Air temperature can cause errors on submerged weight read and even effective porosity, because it is closely related to the temperature, density, and buoyancy of water. Consequently, for accurate measurement of effective porosity in a laboratory, efforts for maintaining air or water temperature constant during the experiment, or a temperature correction from other information are needed.

Current status and trends in estimated intakes and major food groups of vitamin E among Korean adults: Using the 1~6th Korea National Health and Nutrition Examination Survey (한국 성인의 비타민 E 섭취량 및 급원식품군의 현황 및 추이 : 제 1~6기 국민건강 영양조사 자료를 이용하여)

  • Ahn, Seoeun;Jun, Shinyoung;Kim, Seong-Ah;Ha, Kyungho;Joung, Hyojee
    • Journal of Nutrition and Health
    • /
    • v.50 no.5
    • /
    • pp.483-493
    • /
    • 2017
  • Purpose: The purpose of this study was to determine trends in dietary vitamin E intakes and contributing food groups among Korean adults. Methods: This study included 66,695 subjects aged ${\geq}19years$ who completed a nutrition survey as part of the Korea National Health and Nutrition Examination Survey (1998, 2001, 2005, 2007~2009, 2010~2012, 2013~2015). We estimated individual daily intakes of ${\alpha}-$, ${\beta}-$, ${\gamma}-$, ${\delta}-tocopherol$, and total vitamin E by linking food consumption data with a vitamin E database of commonly consumed foods. Results: Daily vitamin E intake significantly increased from $6.4mg\;{\alpha}-TE/d$ in 1998 to $7.7mg\;{\alpha}-TE/d$ in 2013~2015 (p for trend < 0.0001) among men as well as from $5.4mg\;{\alpha}-TE/d$ in 1998 to $6.5mg\;{\alpha}-TE/d$ in 2013~2015 among women (p for trend < 0.0001). However, the intake of vitamin E was lower than the adequate intake (AI) of Dietary Reference Intakes for Koreans 2015 (2015 KDRI). In 2013~2015, men consumed 6.5 mg/d of ${\alpha}-tocopherol$, 0.5 mg/d of ${\beta}-tocopherol$, 6.0 mg/d of ${\gamma}-tocopherol$, and 3.9 mg/d of ${\delta}-tocopherol$, whereas women consumed 5.7 mg/d of ${\alpha}-tocopherol$, 0.4 mg/d of ${\beta}-tocopherol$, 4.8 mg/d of ${\gamma}-tocopherol$, and 2.8 mg/d of ${\delta}-tocopherol$. The major food groups contributing to vitamin E intake were vegetables (men: 23.3%, women: 22.7%), grains (men: 14.5%, women: 13.9%), and eggs (men: 13.0%, women: 12.5%). Conclusion: This study provides scientific evidence for vitamin E intake in Korean adults. Since the current intake of vitamin E was lower than the reference intakes set by 2015 KDRI, dietary vitamin E intake should be monitored regularly among Korean adults.