• Title/Summary/Keyword: Reference ranges

Search Result 248, Processing Time 0.031 seconds

Diagnostic Techniques of Lightning Arresters for DC Electric Traction Vehicles (직류전동차용 피뢰기 진단기술)

  • Kil Gyung-Suk;Song Jae-Yong;Kim Il-Kwon;Moon Seung-Bo;Shin Gwang-Chul
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.357-361
    • /
    • 2006
  • This paper dealt with the performance evaluation and the diagnostic techniques of lightning arresters for DC electric traction vehicle. Field Measurements on the protective operation of lightning arresters against surge currents were carried out on running vehicles to acquire the data necessary for the diagnosis. The frequency and the magnitude of surge events were analyzed. Surge currents of $1\sim3$ times were recorded in one running service route and their magnitudes were ranges of $150A\sim2kA$. Also, an acceleration experiment on a lightning arrester by the standard lightning impulse current of 8/20 us and 5 kA was performed to know the aging characteristics. After the surge current application of 3,000 times, the reference voltage decreased by 4.5 %, and the leakage current was below 10 uA at the continuous operating voltage and about 50 uA at the rated voltage. From the experimental results, we propose a decision level of leakage current for the arrester used in this paper and designed an arrester tester which analyzes arrester condition by the magnitude of leakage current.

Relationship between the Measurement Values of the Digital Dust Indicator and Personal Dust Sampler (Digital 분진계와 개인용 분진 포집기의 측정값의 관계)

  • Yoon, Young-No;Lee, Jeong-Joo;Chung, Ho-Keun;Choi, Ho-Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.20 no.2 s.22
    • /
    • pp.255-260
    • /
    • 1987
  • The digital dust indicator (Sibata P-5), one of the direct·reading instruments was evaluated for the respirable dust in the underground coal mine environments. As a reference, respirable dust was determined using three cyclones and/or impactors. All the tests were performed on aerosol in twenty underground coal mines. The coefficients of mass-relative concentration were $0.067{\pm}0.054$ (Mean$\pm$Standard deviation) (range: 0.006-0.172). The relationship between relative concentration and temperature was not significant statistically. Also, the relationship of relative concentration and relative humidity was not significant. Mass concentration and relative concentration were $5.31{\pm}5.22mg/m^3$ and $162{\pm}163$ CPM ($Mean{\pm}Standard$ deviation) respectively. The range of mass concentration was $1.22-22.69mg/m^3$; relative concentration 16-628 CPM. The relationship of mass concentration and relative concentration was not significant in these ranges.

  • PDF

DETERMINATION OF GPS HEIGHT WITH INCORPORATION OF USING SURFACE METEOROLOGICAL MEASUREMENTS

  • Wang, Chuan-Sheng;Liou, Yuei-An;Yeh, Ta-Kang
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.313-316
    • /
    • 2008
  • Although the positioning accuracy of the Global Positioning System (GPS) has been studied extensively and used widely, it is still limited due to errors from sources such as the ionospheric effect, orbital uncertainty, antenna phase center variation, signal multipath and tropospheric influence. This investigation addresses the tropospheric effect on GPS height determination. Data obtained from GPS receivers and co-located surface meteorological instruments in 2003 are adopted in this study. The Ministry of the Interior (MOl), Taiwan, established these GPS receivers as continuous operating reference stations. Two different approaches, parameter estimation and external correction, are utilized to correct the zenith tropospheric delay (ZTD) by applying the surface meteorological measurements (SMM) data. Yet, incorrect pressure measurement leads to very poor accuracy. The GPS height can be affected by a few meters, and the root-mean-square (rms) of the daily solution ranges from a few millimeters to centimeters, no matter what the approach adopted. The effect is least obvious when using SMM data for the parameter estimation approach, but the constant corrections of the GPS height occur more often at higher altitudes. As for the external correction approach, the Saastamoinen model with SMM data makes the repeatability of the GPS height maintained at few centimeters, while the rms of the daily solution displays an improvement of about 2-3 mm.

  • PDF

A numerical method for improving the reliability of knee translation measurement in skin marker-based motion analysis

  • Wang, Hongsheng;Zheng, Nigel
    • Advances in biomechanics and applications
    • /
    • v.1 no.4
    • /
    • pp.269-277
    • /
    • 2014
  • In skin-marker based motion analysis, knee translation measurement is highly dependent on a pre-selected reference point (functional center) on each segment determined by the location of anatomical landmarks. However, the placement of skin markers on palpable anatomical landmarks (i.e., femoral epicondyles) has limited reproducibility. Thus, it produces large variances in knee translation measurement among different subjects, as well as across studies. In order improve the repeatability of knee translation measurement, in this study an optimization method was introduced, by which the femoral functional center was numerically determined. At that point the knee anteroposterior translation during the stance phase of walking was minimized. This new method was tested on 30 healthy subjects during walking in gait lab with motion capture system. Using this new method, the impact of skin marker position (at anatomical landmarks) on the knee translation measurement has been minimized. In addition, the ranges of anteroposterior knee translations during stance phase were significantly (p<0.001) smaller than those measured by conventional method which relies on a pre-selected functional center ($11.1{\pm}3.5mm$ vs. $19.9{\pm}5.5mm$). The results of anteroposterior translation using this new method were very close to a previously reported knee translation (12.4 mm) from dual fluoroscopic imaging technique. Moreover, this new method increased the reproducibility of knee translation measurement by 50%.

A Case of B Cell Lymphoma Presenting with Multiple Osteolysis in a Juvenile Golden Retriever (다발성 골 융해를 동반한 림프종 증례)

  • Choi, Ji-Hye;Lee, Jin-Soo;Kim, Hyun-Wook;Choi, Ul-Soo
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.98-102
    • /
    • 2012
  • A 1.5-year-old male Golden Retriever was presented with worsening lameness of two month duration. Abnomral findings of blood works and serum chemistry included anemia, thrombocytopenia, hypercalcemia and hyperglobulinemia. Radiography revealed osteolysis of polyostotic regions including right femur and tibia, bilateral ilium, and spinous processes from the 13th thoracic vertebra to 5th lumbar vertebra. Enlarged multiple lymph nodes and mixed echo pattern of muscular region ventral to vertebra were observed with ultrasonography. Because concentrations of both parathyroid hormone and parathyroid hormone related peptide were all within reference ranges, humoral hypercalcemia by tumor was ruled out and extensive osteolysis was considered as the cause of hypercalcemia. Based on radiographic and ultrasonographic study, lymphoma, multiple myeloma and osteomyelitis were included in differential diagnosis. Fungal serologic test was negative. Monoclonal gammopathy was not found on serum protein electrophoresis. Cytological and histopathological examinations of the lytic lesions revealed neoplastic lymphoid proliferation, and B cell type clonal expansion was detected by polymerase chain reaction for the antigen receptor gene rearrangement. The case was diagnosed as B cell lymphoma involving polyostotic regions.

Diagnosis and treatment of a calf with patent urachus

  • Ha, Seungmin;Kim, Sooyoung;Kim, Seongmin;Park, Sookyoung;Lee, Soochan;Jung, Kihwa;Kim, Euntae;Gang, Seokjin;Han, Taeseok
    • Korean Journal of Veterinary Service
    • /
    • v.41 no.1
    • /
    • pp.47-49
    • /
    • 2018
  • A 2-month-old female Holstein Friesian calf was noted to leak urine from the umbilicus during urination. She urinated through both the umbilicus and the urethra. A conduit from the umbilicus to the bladder was identified with ultrasonography. Uroperitoneum was ruled out because blood urea nitrogen and creatinine were within reference ranges. Surgery was performed to resect the patent urachus. Urachitis was identified during surgery. Dexamethasone and an antibiotic were used for the inflammation and postoperative cares. Meloxicam was substituted for dexamethasone since the calf showed side effects to dexamethasone. The calf recovered completely and there was no urine leakage from the umbilicus.

Analysis of Database Referenced Navigation by the Combination of Heterogeneous Geophysical Data and Algorithms

  • Lee, Jisun;Kwon, Jay Hyoun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.4
    • /
    • pp.373-382
    • /
    • 2016
  • In this study, an EKF (Extended Kalman Filter) based database reference navigation using both gravity gradient and terrain data was performed to complement the weakness of using only one type of geophysical DB (Database). Furthermore, a new algorithm which combines the EKF and profile matching was developed to improve the stability and accuracy of the positioning. On the basis of simulations, it was found that the overall navigation performance was improved by the combination of geophysical DBs except the two trajectories in which the divergence of TRN (Terrain Referenced Navigation) occurred. To solve the divergence problem, the profile matching algorithm using the terrain data is combined with the EKF. The results show that all trajectories generate the stable performance with positioning error ranges between 14m to 23m although not all trajectories positioning accuracy is improved. The average positioning error from the combined algorithm for all nine trajectories is about 18 m. For further study, a development of a switching geophysical DB or algorithm between the EKF and the profile matching to improve the navigation performance is suggested.

Development of the Standard Size Dimensions and Reference Sizes for Improving Size Suitability of Gloves (장갑치수적합성 향상을 위한 기본치수 및 참고치수 설정)

  • Kim, Eun-Kyong
    • Fashion & Textile Research Journal
    • /
    • v.10 no.6
    • /
    • pp.966-978
    • /
    • 2008
  • The aim of this study was to provide size intervals in hand requisite in design of gloves. In this study, a survey was administered to gather information about glove manufacturers' sizing systems. In addition, KS glove standards' size dimensions were analyzed. As well, the ISO hand sizing system was also studied. Based on all the analyses' results, a new glove size intervals were composed. The size comprised the control dimensions of hand length and hand circumference. The size interval was 8mm in hand length and 13mm in hand circumference. The size range was established by making the coverage above 80%. The coverage of the new size interval system for an adult's hand was 86.4% and 13 sizes were suggested. The coverage of the male size system was 86.0% and 10 sizes were suggested. The coverage of the female size system was 87.6% and 8 sizes were suggested. For the unfitted gloves, size ranges based on hand length and hand circumference were developed. For the adults group, S, M, L, and XL were suggested and the coverage of the new size range was 78.8%. For the male group, S, M, and L were suggested and the coverage was 82.3%. For the female group, S, M, and L were also suggested and the coverage was 81.3%.

Dilution Reference Ranges by Predictive Value of Serum Level β-hCG in Early Pregnancy Viability (임신 초기 임신양상에 따른 혈청 β-hCG의 결과 예측에 의한 희석배수 참고치 설정)

  • Kim, Yoon Sik;Shin, Jang Yong;Seo, Yeong Mi;Yoo, Shin Soo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.210-214
    • /
    • 2004
  • This study was carried out to predict the value of serum ${\beta}$ subunit of humans chorionic gonadotropin(${\beta}$- hCG) in early pregnancy viability. This was performed among 85 women in vitro fertilization and embryo transfer(IVF-ET). The serum ${\beta}$-hCG levels were established for 30 normal singleton pregnancies, 10 twin and triplet pregnancies, 10 preclinical abortions, 10 clinical abortions, 20 biochemical abortions and 5 ectopic pregnancies. In comparison to normal singleton pregnancies, multiple pregnancies showed higher ${\beta}$-hCG. But clinical abortions, preclinical abortions and ectopic pregnancies showed lower ${\beta}$-hCG levels than singleton pregnancies. In conclusion, if we predict the value of serum ${\beta}$-hCG of variable early pregnancies and analyze it, we could predict the dilution protocol. Also, it can be useful in other ways.

  • PDF

CMOS Image Sensor with Dual-Sensitivity Photodiodes and Switching Circuitfor Wide Dynamic Range Operation

  • Lee, Jimin;Choi, Byoung-Soo;Bae, Myunghan;Kim, Sang-Hwan;Oh, Chang-Woo;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.223-227
    • /
    • 2017
  • Conventional CMOS image sensors (CISs) have a trade-off relationship between dynamic range and sensitivity. In addition, their sensitivity is determined by the photodiode capacitance. In this paper, CISs that consist of dual-sensitivity photodiodes in a unit pixel are proposed for achieving wide dynamic ranges. In the proposed CIS, signal charges are generated in the dual photodiodes during integration, and these generated signal charges are accumulated in the floating-diffusion node. The signal charges generated in the high-sensitivity photodiodes are transferred to the input of the comparator through an additional source follower, and the signal voltages converted by the source follower are compared with a reference voltage in the comparator. The output voltage of the comparator determines which photodiode is selected. Therefore, the proposed CIS composed of dual-sensitivity photodiodes extends the dynamic range according to the intensity of light. A $94{\times}150$ pixel array image sensor was designed using a conventional $0.18{\mu}m$ CMOS process and its performance was simulated.