• Title/Summary/Keyword: Reference plane

Search Result 465, Processing Time 0.027 seconds

3D Linear and Circular Interpolation Algorithm for CNC Machines (CNC 공작기계의 3차원 직선 및 원호 보간 알고리즘에 관한 연구)

  • Yang, Min-Yang;Hong, Won-Pyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.9
    • /
    • pp.172-178
    • /
    • 1999
  • 3D linear and circular interpolations are a basic part for the machining of complex shapes. Until now, because of the absence of appropriate algorithms for the generation of 3D lines and circles, a full accomplishment for available machine tool resolution is difficult. this paper presents new algorithms for 3D linear and circular interpolation in the reference pulse technique. In 3D space, the line or circle is not expressed as an implicit function, it is only defined as the intersection of two surfaces. A 3D line is defined as the intersection of two planes, and a 3D circle is defined as the intersection of a plane and the surface of a sphere. Based on these concepts, interpolation algorithms are designed to follow intersection curves in 3D space, and a real-time 3D linear and circular interpolator was developed in software using a PC. The algorithm implemented in a PC showed promising results in interpolation error and speed performance. It is expected that it can be applied to the next generation computerized numerical control systems for the machining of 3D lines, circles and some other complex shapes.

  • PDF

3D Segmentation of a Diagnostic Object in Ultrasound Images Using LoG Operator (초음파 영상에서 LoG 연산자를 이용한 진단 객체의 3차원 분할)

  • 정말남;곽종인;김상현;김남철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.247-257
    • /
    • 2003
  • This paper proposes a three-dimensional (3D) segmentation algorithm for extracting a diagnostic object from ultrasound images by using a LoG operator In the proposed algorithm, 2D cutting planes are first obtained by the equiangular revolution of a cross sectional Plane on a reference axis for a 3D volume data. In each 2D ultrasound image. a region of interest (ROI) box that is included tightly in a diagnostic object of interest is set. Inside the ROI box, a LoG operator, where the value of $\sigma$ is adaptively selected by the distance between reference points and the variance of the 2D image, extracts edges in the 2D image. In Post processing. regions of the edge image are found out by region filling, small regions in the region filled image are removed. and the contour image of the object is obtained by morphological opening finally. a 3D volume of the diagnostic object is rendered from the set of contour images obtained by post-processing. Experimental results for a tumor and gall bladder volume data show that the proposed method yields on average two times reduction in error rate over Krivanek's method when the results obtained manually are used as a reference data.

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.

  • PDF

New Generalized SVPWM Algorithm for Multilevel Inverters

  • Kumar, A. Suresh;Gowri, K. Sri;Kumar, M. Vijay
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1027-1036
    • /
    • 2018
  • In this paper a new generalized space vector pulse width modulation scheme is proposed based on the principle of reverse mapping to drive the switches of multilevel inverters. This projected scheme is developed based on the middle vector of the subhexagon which holds the tip of the reference vector, which plays a major role in mapping the reference vector. A new approach is offered to produce middle vector of the subhexagon which holds tip of the reference vector in the multilevel space vector plane. By using middle vector of the subhexagon, reference vector is linked towards the inner two level sub-hexagon. Then switching vectors, switching sequence and dwell times corresponding to a particular sector of a two-level inverter are determined. After that, by using the two level stage findings, the switching vectors related to exact position of the reference vector are directly generated based on principle of the reverse mapping approach and do not need to be found at n level stage. In the reverse mapping principle, the middle vector of subhexagon is added to the formerly found two level switching vectors. The proposed generalized algorithm is efficient and it can be applied to an inverter of any level. In this paper, the proposed scheme is explained for a five-level inverter and the performance is analyzed for five level and three level inverters through MATLAB. The simulation results are validated by implementing the propose scheme on a V/f controlled three-level inverter fed induction motor using dSPACE control desk.

Reference points suitable for evaluation of the additional arch length required for leveling the curve of Spee

  • Cho, Yong-Hwa;Lim, Sung-Hoon;Gang, Sung-Nam
    • The korean journal of orthodontics
    • /
    • v.46 no.6
    • /
    • pp.356-363
    • /
    • 2016
  • Objective: The additional arch length required for leveling (AALL) the curve of Spee (COS) can be estimated by subtracting the two-dimensional (2D) arch circumference, which is the projection of the three-dimensional (3D) arch circumference onto the occlusal plane, from the 3D arch circumference, which represents the arch length after leveling the COS. The purpose of this study was to determine whether the cusp tips or proximal maximum convexities are more appropriate reference points for estimating the AALL. Methods: Sixteen model setups of the mandibular arch with COS depths ranging from 0 mm to 4.7 mm were constructed using digital simulation. Arch circumferences in 2D and 3D were measured from the cusp tips and proximal maximum convexities and used to calculate the AALL. The values obtained using the two reference points were compared with the paired t -test. Results: Although the 3D arch circumference should be constant regardless of the COS depth, it decreased by 3.8 mm in cusp tip measurements and by 0.4 mm in proximal maximum convexity measurements as the COS deepened to 4.7 mm. AALL values calculated using the cusp tips as reference points were significantly smaller than those calculated using the proximal maximum convexities (p = 0.002). Conclusions: The AALL is underestimated when the cusp tips are used as measurement reference points; the AALL can be measured more accurately using the proximal maximum convexities.

Area storage density of ideal 3-D holographic disk memories (이상적인 디스크형 3차원 홀로그래픽 메모리에서의 면적 저장밀도)

  • 장주석;신동학
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.1
    • /
    • pp.58-64
    • /
    • 2000
  • Assuming that the performance of holographic storage media is ideal, we estimate the area storage density of disk-type holographic memories, when the method of either angle multiplexing, or rotational multiplexing, or both are used. The area storage density is strongly dependent on the f numbers (ratio of focal length to diameter) of both the Fourier transform lens in the signal arm, denoted by $F/#_2$, and the angle range over which the reference beam is incident (or, the equivalent f number corresponding to the angle range denoted by $F/#_1$). The area storage density is largely independent of the pixel pitch of the spatial light modulator when the Fourier plane holograms are recorded, while it is sensitive to the pixel pitch when the image plane holograms are recorded. In general, to obtain high area storage density, the Fourier or at least near Fourier plane holograms rather than the image plane holograms should be recorded. In addition, when the thickness of the recording materials are less than approximately $500\mu\extrm{m}$, rotational multiplexing gives higher area storage densities than angle multiplexing does. To increase the storage density further, however, it is desirable to use both of the two multiplexing methods in combination.nation.

  • PDF

Triple Folded Omnidirectional Microstrip Antenna for GBAS (GBAS용 3중 폴디드 무지향성 마이크로스트립 안테나)

  • Ju, Dae-Keun;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.20 no.4
    • /
    • pp.83-94
    • /
    • 2021
  • In this paper, we proposed a microstrip antenna (center frequency 118 MHz) with an omnidirectional radiation pattern that can replace the antennae used in VDB systems in GBAS. First, to obtain an omnidirectional radiation pattern from a microstrip antenna, we constructed a folded antenna. We then designed a miniaturized triple-folded antenna using perturbation effects. Thus we obtained suitable characteristics with a S11 of -13.91dB, -10 dB bandwidth of 1.5 MHz (1.27%) in the center frequency of 118 MHz. Furthermore, in the yz-plane and xy-plane, the component exhibits an omnidirectional radiation pattern, and the size of the antenna achieves miniaturization of 64.2% compared to the reference antenna. Finally, it is suitable as an antenna for VDB systems in GBAS.

CEPHALOMETRIC NORMS OF THE SOFT TISSUES OF KOREAN FOR ORTHOGNATHIC SURGERY (악교정 수술을 위한 한국 성인 정상교합자의 연조직 기준치)

  • Kim, Kyung-Ho;Choy, Kwang-Chul;Kim, Gin-Kap;Park, Kwang-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.231-238
    • /
    • 2001
  • This study was performed to evaluate soft tissue cephalometric norms for Korean adults which can be implemented in surgical orthodontic treatment planning using selected horizontal reference plane especially for Koreans (Male: $SN-7.5^{\circ}$, Female: $SN-9.0^{\circ}$) and a simplified analytical method. 70 males and 70 females consisting of freshmen of Yonsei University from 1996 to 1997 and students from the Dental College of Yonsei University were chosen according to clinical examination and cephalometric analysis. The samples had normal profiles, normal anteroposterior skeletal relationship(ANB angle of $0^{\circ}\;to\;4^{\circ}$ and Wits appraisal of -4.0mm to 0mm), and Class I molar and canine relationship. They had no missing or supernumerary teeth and had no experience of orthodontic or prosthetic treatment. After the selection of 15 soft tissue landmarks and the construction of horizontal and vertical reference lines, 25 measurements were taken. These consisted of vertical and horizontal linear measurements and angular measurements. The results were as follows. 1. Mean and standard deviation of the measurements were calculated in males and females. 2. Vertical measurements were comparably bigger in males than females whereas anterior facial height ratio(sN-Sn/Sn-sMe) and lower anterior facial height ratio(Sn-Stms/Stmi-sMe) showed no significant difference between sexes. 3. Most of the horizontal measurements in relation to the vertical reference line(G-perpendicular) showed no significant difference between sexes. 4. Nasofacial angle, columellar angle, nasolabial angle and facial contour angle showed no significant difference between sexes. 5. The upper and lower lip were positioned about $-1.0{\pm}2.0mm$ and $+1.0{\pm}2.0mm$ in relation to the Ricketts' esthetic line in both sexes. In this study, soft tissue cephalometric norms of Korean adults for orthognathic surgery were obtained.

  • PDF

Construction of Precise Local Geoid using GPS/Leveling (GPS/Leveling을 이용한 정밀 지역 지오이드 구축)

  • Park, Joon-Kyu;Ahn, Jong-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4595-4600
    • /
    • 2014
  • A geoid has great meaning as a vertical reference plane, and at this point when GPS measurement is vitalized, it is an important factor that makes level measurements with GPS possible. This study carried out GPS and leveling of newly created complex control points targeting Daejeon. The geoid for the precise area was built by calculating the plane location, elevation and the geoid of each reference point using GPS/Leveling. In addition, this study evaluated the potential of GPS leveling throughout the site calibration. The geoid for the precise area intervals of approximately 1.5km throughout the study was determined. The results highlight the possibility of leveling by estimating direct leveling performance and mean altitude deviation by less than 2cm. Based on the results, if a geoid model for the precise and wide area can be developed throughout ongoing research, survey tasks that require elevation can be streamlined and the efficiency maximized.

A Study on the Standard Joint Material and Reference Plane for the Standard of Construction in the Apartment (공동주택 시공표준화를 위한 조립기준면 및 표준마무리재에 관한 연구)

  • Lim, Seok-Ho;Park, Keun-Soo;Lee, Ga-Kyung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.230-235
    • /
    • 2009
  • In our country, the application of the design method of face to face dimension in wall-slab apartment has passed 10 years. So MC design method has fixed in the design step to some degree. In Design and Work Execution of House the exclusive area of the apartment was calculated by face to face dimension. And the term of face to face dimension was known broadly to clients, construction company, etc. But design method of face to face dimension is not to simply extend the room size so far as wall depth in design process but to ensure the actual space should be considered with efficient use and assembly of building components. That is to say, Design method of face to face dimension is not to be defined by design step but to be related with construction and maintenance. However in construction process the point of face to face design method was not understood even now. So the purpose of this study was to extract the effect and question of face to face design method in construction process by survey of actual condition of structure and construction quality, and compare this result with existing construction method. The following project of this study is to survey of actual condition of interior components such as gypsum board, windows & doors etc. Therefore this study is to induce architectural long-life through architectural standardization construction and component's exchange, and, by the subject of the study on Apartment to have design guideline and basis for joining part between Gypsumboard and windows.

  • PDF