Off-axis pSDF Spatial Matched Filter for Pattern Classification (패턴분류를 위한 Off-axis pSDF 공간정합필터)

  • 임종태;박한규;김명수;김성일
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.2
    • /
    • pp.83-88
    • /
    • 1991
  • Studies on space-invariant pattern recognition have been carried out from various approaches. Pattern recognition system using SDF filter, from weighted linear summation of tranining images, has been the focus of research since its first appearence. In this thesis, off-axis pSDF spatial matched filter has been constructed by combining angular multiplexing of off-axis reference plane wave with pSDF filter made from pseudo-inverse algorithm, and transformed to phase only filter. From observation of the correlation responses in the correlation plane, it is shown that proposed off-axis pSDF spatial matched filter is available to pattern classification and can be used for optical correlator.

  • PDF

CEPHALOMETRIC NORMS OF THE HARD TISSUES OF KOREAN FOR ORTHOGNATHIC SURGERY (악교정 수술을 위한 한국 성인 정상교합자의 경조직 기준치)

  • Kim, Kyung-Ho;Choy, Kwang-Chul;Kim, Hyoung-Gon;Park, Kwang-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.221-230
    • /
    • 2001
  • This study was performed to evaluate hard tissue cephalometric norms for Korean adults which can be implemented in surgical orthodontic treatment planning using selected horizontal reference plane especially for Koreans (Male: $SN-7.5^{\circ}$, Female: $SN-9.0^{\circ}$) and a simplified analytical method. 70 males and 70 females consisting of freshmen of Yonsei University from 1996 to 1997 and students from the Dental College of Yonsei University were chosen according to clinical examination and cephalometric analysis. The samples had normal profiles, normal anteroposterior skeletal relationship(ANB angle of $0^{\circ}$ to $4^{\circ}$ and Wits appraisal of -4.0mm to 0mm), and Class I molar and canine relationship. They had no missing or supernumerary teeth and had no experience of orthodontic or prosthetic treatment. After the selection of 23 landmarks and the construction of horizontal and vertical reference lines, 22 skeletal and 12 dental measurements were taken. These consisted of vertical and horizontal linear measurements and angular measurements. The results were as follows. 1. Mean and standard deviation of the measurements were calculated for males and females. 2. Most of the skeletal vertical measurements, and maxillary and mandibular length were bigger in males than females. Whereas anterior facial height ratio(N-ANS/ANS-Me) as well as maxillary and mandibular antero-posterior position in relation to the vertical reference line(N-perpendicular) showed no signigicant difference between sexes. 3. Maxillary and mandibular dental antero-posterior position in relation to the vertical reference line(N-perpendicular) showed no significant difference between sexes. 4. The upper incisor show(U1-Stms) was $2.1{\pm}1.7mm$ in males and $3.3{\pm}1.7mm$ in females. In this study, hard tissue cephalometric norms of Korean adults for orthognathic surgery were obtained.

  • PDF

Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration

  • Jiansong, Mei;Liya, Ma;Jiarui, Chao;Fei, Liu;Jiefei, Shen
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.369-378
    • /
    • 2022
  • PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations.

Development of Discontinuity Orientation Measurement (DOM) Drilling System and Core Joint Analysis Model (Discontinuity Orientation Measurement (DOM) 시추장비 및 코어절리 해석모델 개발)

  • 조태진;유병옥;원경식
    • Tunnel and Underground Space
    • /
    • v.13 no.1
    • /
    • pp.33-43
    • /
    • 2003
  • Field investigations of the orientations of discontinuity planes inside the borehole for designing the underground rock structures have been depend solely on the borehole image-taking techniques. But, borehole image-taking has to be processed after the completion of drilling operation and also requires the handling of highly expensive apparatus so that practical application is very restricted. In this study Discontinuity Orientation Measurement (DOM) drilling system and discontinuity analysis model RoSA-DOM are developed to acquire the reliable information of rock structure by analyzing the characteristics of joint distribution. DOM drilling system retrieves the rock core on which the reference line of pre-fixed drilling orientation is engraved. Coordinates of three arbitrary points on the joint surface relative to the position of reference line are assessed to determine the orientation of joint plane. The position of joint plane is also allocated by calculating the location of core axis at which joint plane is intersected. Then, the formation of joint set is analyzed by utilizing the clustering algorithm. Total and set spacings are calculated by considering the borehole axis as the scanline. Engineering applicability of in-situ rock mass around the borehole is also estimated by calculating the total and regional RQDs along the borehole axis.

Decoupled Neural Network Reference Compensation Technique for a PD Controlled Two Degrees-of-Freedom Inverted Pendulum

  • Seul Jung;Cho, Hyun-Taek
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.1
    • /
    • pp.92-99
    • /
    • 2004
  • In this paper, the decoupled neural network reference compensation technique (DRCT) is applied to the control of a two degrees-of-freedom inverted pendulum mounted on an x-y table. Neural networks are used as auxiliary controllers for both the x axis and y axis of the PD controlled inverted pendulum. The DRCT method known to compensate for uncertainties at the trajectory level is used to control both the angle of a pendulum and the position of a cart simultaneously. Implementation of an on-line neural network learning algorithm has been implemented on the DSP board of the dSpace DSP system. Experimental studies have shown successful balancing of a pendulum on an x-y plane and good position control under external disturbances as well.

Determination of Regulator Parameters and Transient Analysis of Modified Self-commutating CSI-fed IM Drive

  • Pandey, A.K.;Tripathi, S.M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.48-58
    • /
    • 2011
  • In this paper, an attempt has been made to design the current and speed proportional and integral (PI) regulators of self-commutating current source inverter-fed induction motor drive having capacitors at the machine end and to investigate the transient performance of the same for step changes in reference speed. The mathematical model of the complete drive system is developed in closed loop, and the characteristic equations of the systems are derived using perturbation about steady-state operating point in order to develop the characteristic equations. The D-partition technique is used for finding the stable region in the parametric plane. Frequency scanning technique is used to confirm the stability region. Final selection of the regulator parameters is done by comparing the transient response of the current and speed loops for step variations in reference. The performance of the drive is observed analytically through MATLAB simulation.

Elastic-Plastic Fracture Mechanics Analyses For circumferential Part-through Surface Cracks At The Interface Between Elbows and Pipes (직관과 곡관의 경계 용접부에 존재하는 원주방향 표면균열에 대한 탄소성 파괴역학 해석)

  • Song, Tae-Kwang;Oh, Chang-Kyun;Kim, Yun-Jae;Kim, Jong-Sung;Jin, Tae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1766-1771
    • /
    • 2007
  • This paper presents plastic limit loads and approximate J-integral estimates for circumferential part-through surface crack at the interface between elbows and pipes. Based on finite element limit analyses using elastic-perfectly plastic materials, plastic limit moments under in-plane bending are obtained and it is found that they are similar those for circumferential part-through surface cracks in the center of elbow. Based on present FE results, closed-form limit load solutions are proposed. Welds are not explicitly considered and all materials are assumed to be homogeneous. And the method to estimate the elastic-plastic J-integral for circumferential part-through surface cracks at the interface between elbows and straight pipes is proposed based on the reference stress approach, which was compared with corresponding solutions for straight pipes.

  • PDF

Improvement of accuracy of surface measurement in the phase-shifting shadow moire method (위상이동 그림자 무아레방법에서 형상측정 정확도의 개선)

  • 유원재;강영준;권기용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.402-406
    • /
    • 1995
  • The shadow moire is one the optical techniques which able to give contour lines of an object with respect to a master grating plane. The moire patterns are issued from the superposition of a grating and its shadow projected on the surface of an object. But in the conventional shadow moire method the reference grating and deformed grating are mutually dependent, it is impossible to obtain uniform phase shifts on the whole field by moving the reference grating. Here we propose ane trial to apply phase shifting to conventional shadow moire. When, in the conventional arrangement, Phase-shifting that is sctually constant regardless of fringe orders is achieved by moving the grating and the light source. Finally we obtained a better result by using this procedure and applied the phase shifting shadow moire to three dimensional measurement.

  • PDF

Color display evaluation vs. viewing angle using $L^*a^*b^*$ color space and Fourier-optics measurements

  • Boher, Pierre;Leroux, Thierry;Bignon, Thibault;Blanc, Pierre
    • Journal of Information Display
    • /
    • v.12 no.4
    • /
    • pp.179-190
    • /
    • 2011
  • A complete analysis of the color-viewing-angle properties of different displays is presented herein using color-viewing-angle measurements made with a Fourier-optics system. The color gamut in the CIE u'v' chromatic plane was computed for all the viewing angles. The introduction of the lightness using the $L^*a^*b^*$ color space allowed a more precise analysis of the emissive properties of each display. The displays can be directly compared using a common reference. The viewing-angle dependence can be analyzed in full detail using the on-axis values as reference. The gravity center behavior and area of the color hull were computed for a more precise evaluation and comparison.

A study on the flatness of automotive torque-angle sensors (자동차 토크앵글센서(TAS)의 평면 정밀도에 관한 연구)

  • Yoon, Sean-Jhin;Cho, Yong-Moo
    • Design & Manufacturing
    • /
    • v.12 no.2
    • /
    • pp.11-15
    • /
    • 2018
  • In this study, we proposed three analysis methods to calculate the flatness of torque-angle sensors (TAS). We introduced two statistical and one geometrical methods in evaluating the precision of the flat plane in the axis direction for TAS. To verified the results, we fabricated TAS and a reference sample using a injection molding machine, mold, polyester as a raw material. We measured ($x_i$, $y_i$) position using 3D contact automated system and applied three analysis methods developed for TAS and a reference sample to see the feasibility. While each analysis method has its own pros and cons, the analysis using the shortest optimal distance was the most precise technique for the flatness evaluation of TAS components.