Browse > Article
http://dx.doi.org/10.5370/JEET.2011.6.1.048

Determination of Regulator Parameters and Transient Analysis of Modified Self-commutating CSI-fed IM Drive  

Pandey, A.K. (Department of Electrical Engineering, Madan Mohan Malaviya Engineering College)
Tripathi, S.M. (Department of Electrical Engineering, Kamla Nehru Institute of Technology)
Publication Information
Journal of Electrical Engineering and Technology / v.6, no.1, 2011 , pp. 48-58 More about this Journal
Abstract
In this paper, an attempt has been made to design the current and speed proportional and integral (PI) regulators of self-commutating current source inverter-fed induction motor drive having capacitors at the machine end and to investigate the transient performance of the same for step changes in reference speed. The mathematical model of the complete drive system is developed in closed loop, and the characteristic equations of the systems are derived using perturbation about steady-state operating point in order to develop the characteristic equations. The D-partition technique is used for finding the stable region in the parametric plane. Frequency scanning technique is used to confirm the stability region. Final selection of the regulator parameters is done by comparing the transient response of the current and speed loops for step variations in reference. The performance of the drive is observed analytically through MATLAB simulation.
Keywords
Current source inverter; D-partition technique; Frequency scanning; Induction motor drive; Speed and current regulator; Transient performance;
Citations & Related Records

Times Cited By Web Of Science : 2
Times Cited By SCOPUS : 2
연도 인용수 순위
  • Reference
1 P. Agarwal and V. K. Verma, "Performance Evaluation of Current Source Inverter-Fed Induction Motor Drive", Journals of Institution of Engineers, Vol.72, pp.209-217, February 1992.
2 P. N. Enjeti, P. D. Ziogas and J. F. Lindsay, "Pro grammed PWM technique to eliminate harmonics: A critical evaluation", IEEE Transactions on Industry Applications, Vol. 26, No. 2, pp. 302-315, March/ April 1990.   DOI   ScienceOn
3 S. R. Bowes and R. I. Bullough, "Optimal PWM Microprocessor Controlled Current-Source Inverter Drives", IEEE proceedings, Vol. 135, Pt. B, No. 2, pp. 59-75, March 1988.   DOI   ScienceOn
4 Y. Xiao, B. Wu, S. Rizzo and R. Sotuden, "A Novel Power Factor Control Scheme for High Power GTO Current Source Converter", Conference Record IEEE-IAS, pp.865-869, 1996.
5 Pramod Agarwal, V. K. Verma and A. K. Pandey, "Performance Evaluation of a Self-Commutating CSI-Fed Induction Motor Drive for Different Operating Conditions, IETE Journal of Research, Vol. 54, Issue 4, July/Aug. 2008.
6 P. Agarwal and V. K. Verma, "Parameter Coordination of Microcomputer Controlled CSI Fed Induction Motor Drive", IE (I) Journal – EL, Vol. 88, December 2007.
7 A. K. Pandey, Pramod Agarwal and V. K. Verma, "Optimal Capacitor Selection for Modified Self Commutated CSI-fed Induction Motor Drive", IEEE ISIE 2006, Montreal, Quebec, Canada, pp. 1166-1171, July 9-12, 2006.
8 Pramod Agarwal, A. K. Pandey and V. K. Verma, "Performance Investigation of Modified Self-Commutated CSI-fed Induction Motor Drive, Asian Power Electronics Journal, Vol. 3, No. 1, pp. 21-29, Sept 2009.
9 J. Nanda, "Analysis of Steady State Stability of a Two Machine System by the D-Composition Technique", IEEE Transactions of Power Apparatus and Systems, Vol. 90, pp. 1848-1855, July / Aug. 1971.   DOI   ScienceOn
10 M. A. Aizerman, "Theory of Automatic Control", Chapter-3, Pergamon Press, New York, 1963.