• Title/Summary/Keyword: Reference plane

Search Result 467, Processing Time 0.027 seconds

A Study on the Development of Image Processing Measurement System on the Structural Analysis by Optical Non-contact Measurement (광학적 비접촉 측정에 의한 구조물 해석의 화상처리 계측 시스템 개발에 관한 연구)

  • 김경석
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.6
    • /
    • pp.78-83
    • /
    • 1999
  • This study discusses a non-contact optical technique, electronic speckle pattern interformetry(ESPI), that is well suited for in-plane and out-of-plane deformation measurement. However, the existing ESPI methods that are based on dual-exposure, real-time and time-average method have difficulties for accurate measurement of structure, due to irregular intensity and shake of phase. Therefore, phase shifting method has been proposed in order to solve this problem. About the method, the path of reference light in interferometry is shifted and added to least square fitting method to make the improvement in distinction and precision. This proposed method is applied to measure in -plane displacement that is compared with the previous method. Also, Used as specimen AS4/PE따 [30/=30/90]s was analyzed by ESPI based on real-time to determine the characteristics of vibration under no-load and tension. These results are quantitatively compared with those of FEM analysis inmode shapes.

  • PDF

Limit Loads for Pipe Bends under Combined Pressure and in-Plane Bending Based on Finite Element Limit Analysis (압력과 모멘트의 복합하중을 받는 곡관에 대한 유한요소 한계하중 해석)

  • Oh C.S.;Kim Y.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.401-402
    • /
    • 2006
  • In the present paper, approximate plastic limit load solutions for pipe bends under combined internal pressure and bending are obtained from detailed three-dimensional (3-D) FE limit analyses based on elastic-perfectly plastic materials with the small geometry change option. The present FE results show that existing limit load solutions for pipe bends are lower bounds but can be very different from the present FE results in some cases, particularly for bending. Accordingly closed-form approximations are proposed for pipe bends under combined pressure and in-plane bending based on the present FE results. The proposed limit load solutions would be a basis of defective pipe bends and be useful to estimate non-linear fracture mechanics parameters based on the reference stress approach.

  • PDF

Multiview Stereoscopic Display based on Volume Holographic Memory (체적 홀로그래픽 메모리를 이용한 다시점 스테레오스코픽 디스플레이)

  • 이승현;손광철;심원섭;양훈기;김은수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.688-695
    • /
    • 2000
  • We present a multi-view autostereoscopic display system based on volume holographic storage technique. In this proposed system, the interference pattern of spatial multiplexed plane reference and angular multiplexed plane object beams are recorded into a photorefractive crystal, which plays a role of guiding object beams of multi-view images into the desired persfective directions. For reconstruction, object beams containing the desired multi-view image information, which satisfy Bragg matching condition, are illuminated in the time-division multiplexed manner onto the crystal. Then multiple stereoscopic images are Projected to the display plane for autostereoscopic 3D viewing.

  • PDF

Propagation Analysis of DGPS Antenna for Radial Ground and Obstacle

  • Kim, Young-Wan
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.4
    • /
    • pp.363-368
    • /
    • 2011
  • The DGPS transmits the enhancement signal to GPS using the medium frequency band. The NDGPS service that covers the Korean peninsula has been started since 2009. The service area of ocean-based DGPS(maritime-DGPS) reference stations covers the 100NM, but land-based DGPS(land-DGPS) covers 80km service area less than that of maritime DGPS. The DGPS's antenna has the top-loaded monopole antenna type. Top-loaded monopoles are the logical antennas to be used in order to get a low profile antenna and a performance according to the broadcaster and communication needs. The antenna needs to get the ground plane with good conductivity characteristics and flat ground plane without obstacle near to the transmitting antenna. In this paper, the radiation characteristics of an equivalent MF antenna are analyzed in view points of the ground conductivity and the ground plane with obstacle near to the antenna.

Performance Test of Hypocenter Determination Methods under the Assumption of Inaccurate Velocity Models: A case of surface microseismic monitoring (부정확한 속도 모델을 가정한 진원 결정 방법의 성능평가: 지표면 미소지진 모니터링 사례)

  • Woo, Jeong-Ung;Rhie, Junkee;Kang, Tae-Seob
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • The hypocenter distribution of microseismic events generated by hydraulic fracturing for shale gas development provides essential information for understanding characteristics of fracture network. In this study, we evaluate how inaccurate velocity models influence the inversion results of two widely used location programs, hypoellipse and hypoDD, which are developed based on an iterative linear inversion. We assume that 98 stations are densely located inside the circle with a radius of 4 km and 5 artificial hypocenter sets (S0 ~ S4) are located from the center of the network to the south with 1 km interval. Each hypocenter set contains 25 events placed on the plane. To quantify accuracies of the inversion results, we defined 6 parameters: difference between average hypocenters of assumed and inverted locations, $d_1$; ratio of assumed and inverted areas estimated by hypocenters, r; difference between dip of the reference plane and the best fitting plane for determined hypocenters, ${\theta}$; difference between strike of the reference plane and the best fitting plane for determined hypocenters, ${\phi}$; root-mean-square distance between hypocenters and the best fitting plane, $d_2$; root-mean-square error in horizontal direction on the best fitting plane, $d_3$. Synthetic travel times are calculated for the reference model having 1D layered structure and the inaccurate velocity model for the inversion is constructed by using normal distribution with standard deviations of 0.1, 0.2, and 0.3 km/s, respectively, with respect to the reference model. The parameters $d_1$, r, ${\theta}$, and $d_2$ show positive correlation with the level of velocity perturbations, but the others are not sensitive to the perturbations except S4, which is located at the outer boundary of the network. In cases of S0, S1, S2, and S3, hypoellipse and hypoDD provide similar results for $d_1$. However, for other parameters, hypoDD shows much better results and errors of locations can be reduced by about several meters regardless of the level of perturbations. In light of the purpose to understand the characteristics of hydraulic fracturing, $1{\sigma}$ error of velocity structure should be under 0.2 km/s in hypoellipse and 0.3 km/s in hypoDD.

Nonlinear 3D image correlator using computational integral imaging reconstruction method (컴퓨터 집적 영상 복원 방법을 이용한 비선형 3D 영상 상관기)

  • Shin, Dong-Hak;Hong, Seok-Min;Kim, Kyoung-Won;Lee, Byung-Gook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.155-157
    • /
    • 2012
  • In this paper, we propose a nonlinear 3D image correlator using computational reconstruction of 3D images based on integral imaging. In the proposed method, the elemental images for reference 3D object and target 3D object are recorded through the lens array. The recorded elemental images are reconstructed as reference plane image and target plane images using the computational integral imaging reconstruction algorithm and the nonolinear correlation between them is performed for object recognition. To show the usefulness of the proposed method, the preliminary experiments are carried out and the experimental results are presented compared with the conventional results.

  • PDF

A Study on the Standardization of the Built-in Wardrobe by Housing Inside Dimension (공동주택 안목치수 설계기준에 의한 붙박이장의 표준화방안 연구)

  • Lee, Ga-Kyung;Lim, Seok-Ho
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.53-60
    • /
    • 2010
  • Built-in wardrobe is constructing after ordering and making, because built-in wardrobe's size is fixed as housing measurement. It is hard to speak built-in wardrobe components of construction in these ways, and application of an MC (Modular Coordination) design system is meaningless too. And above all, measurement before construction isn't to expect standardization, and to increase custom-made furniture. So I suggest the standardization of built-in wardrobe utilizing standard last finish and reference plane in order to prevent an evil influence of built-in wardrobe's construction. And we utilized a reference plane, and we present construction document and design plan in order to solve these problems. The first stage, we investigate manufacture of a preferential domestic system kitchen and construction state, and we derive from a problem in viewpoints of standardization for this. And we analyze an effect got by application of the assembly basis aspect that we presented, and we can raise efficiency of standardization of housing and construction industry, and we light ultimately up. I will apply a standardization plan as above, and define that this assures a standardization of components and an economic effect.

Design of 2-axis compensation servo system for angle multiplexing Holographic Data Storage (각 다중화 방식의 홀로그래픽 정보저장기기의 양방향틸트 보상시스템 설계)

  • Lim, Sung-Yong;Kim, Nak-Yeong;Han, Cho-Lok;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.1
    • /
    • pp.19-24
    • /
    • 2011
  • Holographic Data Storage System, one of the next generation data storage devices, is a 2-dimensional page oriented memory system using volume holograms in writing and retrieving process. Recently photopolymer with disc type substrate was selected as a media for the Holographic Data Storage System. The disc tilt occurs when the media rotates and the external disturbance applies. The disc tilt causes the change of the angle between the reference beam and the media, the data cannot be retrieved with the right angle or other data page is retrieved. The tilt is generated in a 2-axis direction (tangential, radial). The tangential tilt direction is the same with the multiplexing plane, while the radial tilt direction is a perpendicular to the multiplexing plane. In this research we propose 2-axis tilt angle servo system. The tilt errors are measured by using external photo detector and the additional red laser. Then the tangential direction tilt is compensated by using the galvano mirror. Also the radial direction tilt is compensated by the rotating prism between the relay lens in the reference field. Finally we confirm the compensation results through the Signal to Noise Ratio(SNR) and Bit Error Rate(BER).

Strain recovery-based equilibrated transverse shear stresses in functionally graded shell-like structures

  • Jin-Rae Cho
    • Structural Engineering and Mechanics
    • /
    • v.91 no.5
    • /
    • pp.527-538
    • /
    • 2024
  • The standard numerical approximation of structural displacement field leads to the thickness-wise transverse shear stress distributions which are quite different from the exact ones. To overcome this inherent problem, an effective and reliable post-processing method is presented based on the strain recovery and the stress equilibrium, particularly for functionally graded cylindrical and conical elastic panels. The present method is developed in the framework of locking-free 2-D natural element method. Through the recovery of displacement component-wise derivatives, the element-wise discontinuous in-plane strain distributions are enhanced to be globally continuous and smoothened. And, using the continuous in-plane strains, the troublesome poor transverse shear stress distributions are enhanced through the thickness-wise integration of static equilibrium equations. The validity of present post-processing method is verified through the comparison with the reference solutions. In addition, the comparative experiments are also performed to investigate the difference between the present method and other available post-processing methods. The numerical results confirm that the present method provides the accurate transverse shear stress distributions which are consistent with the reference solutions and much better than other available methods.

Comparison of Air Kerma­based and Absorbed Dose to Water­based Protocols in the Dosimetry of High Energy Electron Beams (고 에너지 전자선에 대한 공기커마와 물 흡수선량에 기반한 프로토콜간의 비교)

  • 박창현;신동오;박성용
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • A few years ago, a proposal was made to change the dosimetry from the air kerma-based reference dosimetry to the absorbed dose-based reference dosimetry for all radiotherapy beams of ionizing radiation to improve the accuracy of dosimetry. Here, we present a dosimetry study in which the two most widespread absorbed dose­based protocols (IAEA TRS­398 and AAPM TG­51) were compared with an air kerma­based protocol (IAEA TRS-277) by measuring the absorbed dose in the same reference depth. Measurements were performed in three clinical electron beam energies using a PTW 30002 cylindrical chamber, and Markus and Roos plane­parallel chambers. $^{60}$ Co calibration factors were obtained from the KFDA. The absorbed dose differences between the air kerma­based and absorbed dose­based protocols were within 2.0% for all chambers in all beams. The results thus show that the obtained absolute dose values will be not significantly altered by changing from the air kerma­based dosimetry to the absorbed dose­based dosimetry. It was also shown that absorbed dose values between the absorbed dose­based protocols agreed by deviations of less than 0.5% for a cylindrical chamber and less than 0.7% for plane­parallel chambers using cross­calibration factors. Although the use of a cylindrical chamber and plane­parallel chambers resulted in a difference of less than 2% for all situations investigated here, to reduce errors, the plane­parallel chambers are recommended for electron energies in which the use of cylindrical chamber is not permitted in each protocol.

  • PDF