• 제목/요약/키워드: Reference phase

Search Result 1,366, Processing Time 0.025 seconds

A Novel Position Sensorless Speed Control Scheme for Permanent Magnet Synchronous Motor Drives (영구자석 동기전동기의 센서리스 속도제어 시스템)

  • Won, Tae-Hyun;Park, Han-Woong;Song, Dall-Sup;Kim, Moon-Soo;Lee, Man-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.112-116
    • /
    • 2002
  • A sensorless control strategy for permanent magnet synchronous motors is presented in this paper. A speed control scheme based on the measurement and observation of stator current, voltage. and flux vector is proposed. Two phase voltages and two stator currents are measured and processed in discrete form in DSP. The rotor position and speed are estimated through the stator flux and its derivative estimation. Flux and its derivative are calculated in the stationary reference frame and used to estimate the speed and position. The rotor position angle is then used in a microcontroller to produce the appropriate stator current command signals for the hysteresis current controller of the inverter. The closed-loop speed control has been shown to be effective from standstill to rated speed. Moreover, a flux drift problem caused by the integration can be eliminated so that a stable sensorless starting and running operation can be achieved. Computer simulation and experimental results are presented to demonstrate the effectiveness of the proposed scheme.

  • PDF

A Novel Method of the Harmonic Analysis by Using the Multi-Carrier PWM Techniques in the Multi-Level Inverter (멀티 레벨 인버터에서 멀티 캐리어 PWM 방법을 사용한 고조파 분석의 새로운 방법)

  • Kim June-Sung;Kim Tae-Jin;Kang Dae-Wook;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.171-174
    • /
    • 2002
  • This paper deals with a novel method in order to analyze the harmonic characteristics in the multi-level inverter. Generally, the magnitude of harmonic components is different according to the carrier PWM techniques, modulation Index(Mi), and the level of multi-level inverter The previous papers analyzed the harmonic characteristics from the viewpoint of the space vector. Hence, the calculation of the harmonic vector becomes difficult and complex in 4-level or more than S-level. However, the proposed method of this paper reduced an amount of calculation and simplified the process of calculation by using the relationship between reference voltage and output phase voltage to load neutral. This paper analyzed the harmonic and it is applied to the multi-carrier PWM techniques in 5- level and other-level of cascaded inverter system.

  • PDF

An Adoptive Current Control Scheme of an AC Servo Motor for Performance Improvement of a Servo Drive (서보 드라이브 성능 향상을 위한 AC 서보 전동기의 적응형 전류 제어)

  • Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.96-103
    • /
    • 2006
  • An MRAC-based adaptive current control scheme of an AC servo motor is presented for the performance improvement of a servo drive. Although the predictive current control is known to give ideal transient and steady-state responses, its steady-state response my be degraded under motor parameter variations. To overcome such a limitation, the disturbances caused by the parameter variations will be estimated by using an MRAC technique and compensated by a feedforward control. The proposed scheme does not require the measurement of the phase voltage unlike the conventional disturbance estimation scheme using observer. The asymptotic stability is proved. The proposed scheme is implemented using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

A New Random SPWM Technique for AC-AC Converter-Based WECS

  • Singh, Navdeep;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.939-950
    • /
    • 2015
  • A single-stage AC-AC converter has been designed for a wind energy conversion system (WECS) that eliminates multistage operation and DC-link filter elements, thus resolving size, weight, and reliability issues. A simple switching strategy is used to control the switches that changes the variable-frequency AC output of an electrical generator to a constant-frequency supply to feed into a distributed electrical load/grid. In addition, a modified random sinusoidal pulse width modulation (RSPWM) technique has been developed for the designed converter to make the overall system more efficient by increasing generating power capacity and reducing the effects of inter-harmonics and sub-harmonics generated in the WECS. The technique uses carrier and reference waves of variable switching frequency to calculate the firing angles of the switches of the converter so that the three-phase output voltage of the converter is very close to a sine wave with reduced THD. A comparison of the performance of the proposed RSPWM technique with the conventional SPWM demonstrated that the power generated by a turbine in the proposed approximately increased by 5% to 10% and THD reduces by 40% both in voltage and current with respect to conventional SPWM.

Enhanced Dynamic Response of SRF-PLL System for High Dynamic Performance during Voltage Disturbance

  • Choi, Hyeong-Jin;Song, Seung-Ho;Jeong, Seung-Gi;Choi, Ju-Yeop;Choy, Ick
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.369-374
    • /
    • 2011
  • Usually, a LPF (low pass filter) is used in the feedback loop of a SRF (synchronous reference frame) - PLL (phase locked loop) system because the measured grid voltage contains harmonic distortions and sensor noises. In this paper, it is shown that the cut-off frequency of the LPF should be designed to suppress the harmonic ripples contained in the measured voltage. Also, a new design method for the loop gain of the PI-type controller in the SRF-PLL is proposed with consideration of the dynamics of the LPF. As a result, a better transient response can be obtained with the proposed design method. The LPF frequency and the PI controller gain are designed in coordination according to the steady state and dynamic performance requirements. Furthermore, in the proposed method, the controller gain and the LPF cut-off frequency are changed from their normal value to a transient value when a voltage disturbance is detected. This paper shows the feasibility and usefulness of the proposed methods through the computer simulations and experimental results.

Fault Detection for thyristors of Power Converter Module in Control Rod Control System (원자로 제어봉구동장치 제어시스템의 전력변환기 사이리스터 고장 검출)

  • Kim, Choon-Kyung;Cheon, Jong-Min;Lee, Jong-Moo;Jung, Soon-Hyun;Kwon, Soon-Man
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.559-562
    • /
    • 2003
  • In this paper, we introduce a new method detecting thyristor faults of the power converter module in Control Rod Control System. When we control the currents in each coil of Control Rod Drive Mechanism by using the current control method, the current value can follow the current reference despite the faults like the missing phase or the diode acting. Comparing the fault current values with the normal current values, the bad transient characteristics of the abnormal current can make the operations of control rods incorrect. In this case, the information from the current trends cannot be enough to detect the fault occurrence in thyristors. Instead of the coil currents, the state of thyristors can be watched by measuring the coil voltages. In the existing system of Westinghouse type, the ripple detector takes charge of this task. But this detector has some shortcomings in the point of time for fault detection, we come to devise a new fault detection method solving the problems which belong to the ripple detector.

  • PDF

Effects of Deviations of RDPS on the Compensation for Distorted WDM Channels in Dispersion-Managed Optical Transmission Links of Random Distribution Schemes (랜덤 분포 구조의 분산 제어 광전송 링크에서 RDPS의 편차가 왜곡된 WDM 채널의 보상에 미치는 영향)

  • Lee, Seong-Real
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.2
    • /
    • pp.147-152
    • /
    • 2015
  • The compensation characteristics of WDM channels depending on residual dispersion per spans (RDPS) deviation in optical links with the randomly distributed RDPS for the adaptive configuration are investigated in this paper. Also, the link design rule related with RDPS deviations is proposed, from the viewpoint of the allowable net residual dispersion (NRD). It is confirmed that the effect of compensation for the distorted WDM channels is more increased as RDPS deviation is smaller. Also, it is confirmed that the decrease of the allowable NRD range for the exact eye opening penalty (EOP) is proportional to RDPS deviation. Therefore, the results of this research is expected to be the design reference for the flexible link configuration of long-haul optical transmission links.

B-6 Vitamers and $\beta$-Glucoside Conjugates in Milk of American and Egyptian Women during the first Six Months of Lactation

  • Lee, Jeong-Yeon
    • Journal of Nutrition and Health
    • /
    • v.30 no.4
    • /
    • pp.425-433
    • /
    • 1997
  • Levels and distribution of five B-6 vitamers(PMP, PM, PLP, PL, and PN) and pyridoxine $\beta$-glucoside conjugates(PN-glucoside) were examined in milk of American women who received supplements of 2.5 or 10mg PN HCl/d and of unsupplemented Egyptian women during the first six months of lactation. B-6 vitamer and PN-glucoside levels in human milk were determined by reverse-phase HPLC. Pyridoxal(PL), which has been reported to be the most rapidly absorbed form of vitamin B-6 and may facilitate bioavailability, was the predominant vitamer in human milk of all three groups. Pyridoxal made up 72% of total vitamin B-6 for the 2.5mg supplemented group, 76% for the 10mg group, and 59% for the Egyptian group. Level and Percent PL were significantly lower for Egyptian women. Mean growth of the two American groups was similar to each other and within the normal range of the NCHS reference, however, Egyptian infants showed growth faltering at 6 months. The Percent of PN-glucoside, a less bioavailable form of vitamin B-6 in humans was 1% in milk of American women and was 11% in Egyptian women and these values were significantly different. for Egyptian women, total vitamin B-6 levels in breast milk correlated Positively with animal protein intake(r=0.91) and percent PN-glucosides(r=0.53) and negatively with plant protein intake(r=-0.55). These findings showed that high plant protein intake was associated with low concentrations of PL and total vitamin B-6 in human milk.

  • PDF

A Zero Sequence Voltage Injection Method for Cascaded H-bridge D-STATCOM

  • Yarlagadda, Srinivasa Rao;Pathak, Mukesh Kumar
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1088-1096
    • /
    • 2017
  • Load variations on a distribution line result in voltage fluctuations at the point of common coupling (PCC). In order to keep the magnitude of the PCC voltage constant at its rated value and obtain zero voltage regulation (ZVR), a D-STATCOM is installed for voltage correction. Moreover, the ZVR mode of a D-STATCOM can also be used to balance the source current during unbalanced loading. For medium voltage and high power applications, a D-STATCOM is realized by the cascaded H-bridge topology. In the ZVR mode, the D-STATCOM may draw unbalanced current and in this process is required to handle different phase powers leading to deviations in the cluster voltages. Zero sequence voltage needs to be injected for ZVR mode, which creates circulating power among the phases of the D-STATCOM. The computed zero sequence voltage and the individual DC capacitor balancing controller help the DC cluster voltage follow the reference voltage. The effectiveness of the control scheme is verified by modeling the system in MATLAB/SIMULINK. The obtained simulations are further validated by the experimental results using a dSPACE DS1106 and five-level D-STATCOM experimental set up.

A Study on the Design of PLL for Improving of Characteristics of Locking Time and Jitter (Locking Time과 Jitter 특성의 개선을 위한 PLL 설계에 관한 연구)

  • Park, Jae-Boum;Park, Yun-Sik;Kim, Hwa-Young;Sung, Man-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1188-1191
    • /
    • 2003
  • In this paper, we focus our attention on the improvement of locking time and jitter parameter and propose the new structure of PLL which combined with the FVC, FOVI Matcher(FVC-Output and VCO-input Matching Circuit), Control Circuit and the conventional charge pump PLL. Using fast operation characteristics of the FVC, the circuit matching FVC-Output and VCO-input (FOVI Matcher) made to synchronize very fast. Fast locking time is usually required for application where the PLL has to settle rapidly if they switch from an idle mode to a normal mode and to track high-frequency data bit rate in data recovery systems. After a fast acqusition is achieved by the using the FVC, the conventional PLL operates for removing the phase error between the reference signal and the feedback signal. Therefore this structure can improve the trade-off between acquisition behavior and locked behavior.

  • PDF