• Title/Summary/Keyword: Reference phase

Search Result 1,366, Processing Time 0.023 seconds

Decoupled SVPWM for Five-Phase Permanent Magnet Machines with Trapezoidal Back-EMF

  • Lin, Zhipeng;Liu, Guohai;Zhao, Wenxiang;Chen, Qian
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1424-1433
    • /
    • 2018
  • This paper presents a novel space vector pulse-width modulation (SVPWM) to synthesize an arbitrary non-sinusoidal phase voltage. The key of the proposed method is that the switching vectors used to comprise the reference vectors in the ${\alpha}_1-{\beta}_1$ frame and the ${\alpha}_3-{\beta}_3$ frame are decoupled. In the ${\alpha}_1-{\beta}_1$ frame, the reference vector is comprised by near two large vectors. The corresponding vector comprised by the two vectors in the ${\alpha}_3-{\beta}_3$ frame is considered as a disturbance, which is restrained by close-loop control. In the ${\alpha}_3-{\beta}_3$ frame, there are two methods to comprise the reference vector. Method I is a near two middle vectors method. Method II uses near four vectors (two middle and two little vectors). The proposed SVPWM using decoupled switching vectors can guarantee a maximum modulation index in the ${\alpha}_1-{\beta}_1$ frame. The effectiveness of the proposed method is verified by simulated and experimental results under various operation conditions.

Simplified Control Scheme of Unified Power Quality Conditioner based on Three-phase Three-level (NPC) inverter to Mitigate Current Source Harmonics and Compensate All Voltage Disturbances

  • Salim, Chennai;Toufik, Benchouia Mohamed
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.544-558
    • /
    • 2013
  • This paper proposes a simplified and efficient control scheme for Unified Power Quality Conditioner (UPQC) based on three-level (NPC) inverter capable to mitigate source current harmonics and compensate all voltage disturbances perturbations such us, voltage sags, swells, unbalances and harmonics. The UPQC is designed by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The dc voltage is maintained constant using proportional integral voltage controller. The shunt and series AF are designed using a three-phase three-level (NPC) inverter. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt and the power reactive theory (PQ) for a series APFs. The reference signals for the shunt and series APF are derived from the control algorithm and sensed signals are injected in tow controllers to generate switching signals for series and shunt APFs. The performance of proposed UPQC system is evaluated in terms of power factor correction and mitigation of voltage, current harmonics and all voltage disturbances compensation in three-phase, three-wire power system using MATLAB-Simulink software and SimPowerSystem Toolbox. The simulation results demonstrate that the proposed UPQC system can improve the power quality at the common connection point of the non-linear load.

Control Method of Modular Multilevel Converter to Reduce Switching Losses (스위칭 손실을 줄이기 위한 모듈형 멀티레벨 컨버터의 제어 방법)

  • Park, So-Young;Kim, Jae-Chang;Kwak, Sang-Shin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.476-483
    • /
    • 2017
  • In this paper, a voltage-based model predictive control (MPC) scheme for a modular multilevel converter is used to reduce switching loss. The proposed method calculates an offset voltage that clamps the switching operation of submodules in which the current greatly flows at every sampling period by using the reference phase voltage and the reference phase current. To use the offset voltage, the proposed method converts the current-based MPC to the voltage-based MPC. The proposed voltage-based MPC then generates a new reference pole voltage that clamps the switching of submodules by applying the calculated offset voltage to the phase voltage. Therefore, the proposed method can reduce the switching loss by stopping the switching operation of submodules in which the current greatly flows. The switching loss reduction effect of the proposed method is verified by comparing its loss data with those of the conventional MPC method.

Estimation of Excitation Force and Noise of Drum Washing Machine at Dehydration Condition using Phase Reference Spectrum (위상 기준 스펙트럼을 이용한 드럼 세탁기 탈수 행정시의 가진력 및 방사소음 예측)

  • Kim, Tae Hyeong;Jung, Byung Kyoo;Heo, So Jung;Jeong, Weui Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.7
    • /
    • pp.617-623
    • /
    • 2013
  • Accurate prediction of the radiated noise is important to reduce the noise of the washing machine. It is also necessary to predict the excitation force accurately because excitation force can induce noise. In order to predict the excitation force acting on the washing machine, this paper conducts source identification method by use of phase reference spectrum. In this method, the transfer function between the cabinet and the motor through FEM and the measured response from the surface of the cabinet is used. The analysis of the radiation noise from the identified exciting force has been investigated. The comparison between the predicted SPL and the measured SPL at 1m apart from the front side of the washing machine showed good tendency.

A Novel Fast Open-loop Phase Locking Scheme Based on Synchronous Reference Frame for Three-phase Non-ideal Power Grids

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1513-1525
    • /
    • 2016
  • Rapid and accurate phase synchronization is critical for the reliable control of grid-tied inverters. However, the commonly used software phase-locked loop methods do not always satisfy the need for high-speed and accurate phase synchronization under severe grid imbalance conditions. To address this problem, this study develops a novel open-loop phase locking scheme based on a synchronous reference frame. The proposed scheme is characterized by remarkable response speed, high accuracy, and easy implementation. It comprises three functional cascaded blocks: fast orthogonal signal generation block, fast fundamental-frequency positive sequence component construction block, and fast phase calculation block. The developed virtual orthogonal signal generation method in the first block, which is characterized by noise immunity and high accuracy, can effectively avoid approximation errors and noise amplification in a wide range of sampling frequencies. In the second block, which is the foundation for achieving fast phase synchronization within 3 ms, the fundamental-frequency positive sequence components of unsymmetrical grid voltages can be achieved with the developed orthogonal signal construction strategy and the symmetrical component method. The real-time grid phase can be consequently obtained in the third block, which is free from self-tuning closed-loop control and thus improves the dynamic performance of the proposed scheme. The proposed scheme is adaptive to severe unsymmetrical grid voltages with sudden changes in magnitude, phase, and/or frequency. Moreover, this scheme is able to eliminate phase errors induced by harmonics and random noise. The validity and utility of the proposed scheme are verified by the experimental results.

Development of CITIS Reference Model System on Internet (인터넷 기반 CITIS 참조모델시스템 개발)

  • 주경준;조장혁;박상봉
    • The Journal of Society for e-Business Studies
    • /
    • v.4 no.3
    • /
    • pp.139-158
    • /
    • 1999
  • In this paper we present the development of CITIS(Contractor Integrated Technical Information Service) reference model system which can be utilized for electronic commerce among enterprises. For the physical analysis target model, we selected switching system businesses of Korea Telecom. From analysis of life-cycle business process and data, we derived CITIS reference model containing CITIS To-Be model and CITIS scenario. Derived CITIS reference model is generalized so that it can be used not only for switching system businesses but other business areas regarding CITIS implementation. On the base of the derived CITIS reference model, We also developed CITIS information management system and CITIS-support workflow system as CITIS reference model system. Developed CITIS reference model system supports information and business process sharing among enterprises on internet and it does make a contribution to expansion of CITIS which is moving from conceptual research towards real implementation phase.

  • PDF

Accurate Current Reference Generator for Active Power Filters (능동전력필터의 정밀 기준신호 발생기)

  • Bae Byung-Yeol;Jon Young-Soo;Han Byung-Moon;Soh Yong-Choel
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.575-578
    • /
    • 2004
  • The performance of an active power filter(APF) depends on the inverter characteristic, the control method, and the accuracy of reference signal generator. The accuracy of reference generator is the most critical item to determine the performance of active power filter. This paper introduces a novel reference signal generator composed of improved adaptive predictive filter. The performance of proposed reference signal generator was first verified through a simulation with MATLAB. Furthermore, the application of feasibility was evaluated through experimenting with a single-phase APF prototype based on the proposed reference generator, which was implemented using the TMS320C31 floating-point signal processor. Both simulations and experimental results confirm that our reference signal generator can be used successfully in practical active power filters.

  • PDF

Measurement of Refractive Index Profile of Optical Fiber Using the Diffraction Phase Microscope (회절위상현미경을 이용한 광섬유의 굴절률 프로파일 측정)

  • Jafar-Fard, Mohammad R.;Moon, Sucbei
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.135-142
    • /
    • 2012
  • We have developed a measurement method of the refractive index profile of an optical fiber by using diffraction phase microscopy. In the microscope system, the reference light was extracted directly from the probe light that passed through the sample by means of pinhole filtering with a diffraction grating. The spatial interference pattern produced by the probe light and the reference light was processed to generate the phase image of the sample fiber. The index profile was obtained by the inverse Abel transform of the phase profile. In order to remove the background phase that originated from the index difference between the cladding and the surrounding medium, the background phase was calculated from the phase data of the cladding to make a core phase profile that can be directly transformed to the index profile of the core without the full phase image that includes the entire cladding part.

Air-pressure Control of Diaphragm using Variable Frequency Current Control (가변 주파수 전류 제어에 의한 다이어프램의 압력제어)

  • Lim, Geun-Min;Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.258-265
    • /
    • 2011
  • This paper presents a variable frequency current control scheme for the air-pressure control of diaphragm. Differ from the conventional air-pressure control of diaphragm, the proposed method uses a single-phase inverter to control the phase current and frequency. The phase current is adjusted to keep the reference air-pressure of the diaphragm. And the current frequency is changed to reduce the mechanical vibration. In order to smooth change of the operation with a constant air-pressure, the frequency is changed according to the voltage reference from the current controller. When the phase current is satisfied to the constant air-pressure, the current frequency is increased to reduce the vibration of the diaphragm. When the reference voltage to keep the phase current is over than the set value, the current frequency is decreased to keep the air-pressure. The proposed control scheme is verified by the experimental test of a commercial diaphragm.

An Efficient Battery Charging Algorithm based on State-of-Charge Estimation using 3-Phase AC-DC Boost Converter (3상 AC-DC 승압형 컨버터를 이용한 SOC 추정 기반의 효율적 배터리 충전 알고리즘)

  • Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.96-102
    • /
    • 2015
  • This paper presents battery charging method using 3-phase AC-DC boost converter. General battery charging method is that charging the battery voltage to the reference voltage according to the constant current(CC) control, when it reaches the reference voltage, charging the battery fully according to the constant voltage(CV) control. However, battery chaging time is increased because of the battery impedance, constant current charging section which shoud take the large amount of charge is narrow, and constant voltage charging section which can generate insufficient charge is widen. To improve this problem, we proposes the method to reduce the charging time according to the SOC(State of Charge) estimation using battery impedance.