• Title/Summary/Keyword: Reference pattern

Search Result 898, Processing Time 0.029 seconds

Design of E-Tongue System using Neural Network (신경회로망을 이용한 휴대용 전자 혀 시스템의 설계)

  • Jung, Young-Chang;Kim, Dong-Jin;Kim, Jeong-Do;Jung, Woo-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.2
    • /
    • pp.149-158
    • /
    • 2005
  • In this paper, we have designed and implemented a portable e-tongue (electronic tongue) system using MACS (multi array chemical sensor) and PDA. The system embedded in PDA has merits such as comfortable user interface and data transfer by internet from on-site to remote computer. MACS was made up 7 electrodes (${NH_4}^+$, $Na^+$, $Cl^-$, ${NO_3}^-$, $K^+$, $Ca^{2+}$, $Na^+$, pH) and a reference electrode. For learning the system, we adapted the Levenberg-Marquardt algorithm based on the back-propagation, which could iteratively learned the pre-determined standard patterns, in e-tongue system. Conclusionally, the relationship between the standard patterns and unknown pattern can be easily analyzed. The e-tongue was applied to whiskeys and cognac (one high level whisky, one low level whiskey, two cognac) and 2 sample whiskeys for each standard patterns and unknown patterns. The relationship between the standard patterns and unknown patterns can be easily analyzed.

  • PDF

Pathogenicity of Korean isolates of Acanthamoeba by observing the experimental infection and zymodemes of five isoenzymes

  • Im, Kyung-Il;Shin, Ho-Joon;Seo, Dong-Whan;Jeon, Soung-Hoo;Kim, Tae-Eun
    • Parasites, Hosts and Diseases
    • /
    • v.37 no.2
    • /
    • pp.85-92
    • /
    • 1999
  • To determine the pathogenicity of Acanthamoeba spp. isolated in Korea and to develop a isoenzymatic maker, the mortality rate of infected mice, in vitro cytotoxicity against target cells and isoenzyme band pattern were observed. Five isolates of Acanthamoeba spp. (YM-2, YM-3, YM-4, YM-5 and YM-7) were used in this study as well as three reference Acanthamoeba spp. (A. culbertsoni, A. hatchetti, and A. royreba). According to the mortality rate of infected mice, Korean isolated could be categorized into three groups: high virulent (YM-4), low virulent (YM-2, YM-5, YM-7) and the nonpathogenic group (YM-4), In addition, the virulence of Acanthamoeba spp. was enhanced by brain passage in mice. In the cytotoxicity assay against chinese hamster ovary cells, especially, the cytotoxicity of brain-passaged amoebae was relatively higher than the long-term cultivated ones. The zymodeme patterns of glucose-6-phosphate dehydrogenase (G6PD), malate dehydrogenase (MDH), hexokinase (HK), glutamate oxaloacetate transaminase (GOT) and malic enzyme (ME)of Acanthamoeba spp. were different among each isolate, and also between long-term cultrued amoebae and brain passaged ones. In spites of the polymorphic zymodemes, a slow band of G6PD and K, and an intermediate band of MDH were only observed in pathogenic Acanthamoeba spp., which should be used as isoenzymatic makers.

  • PDF

Interim Report about The Comparative Clinical Study of Efficacy of Gamisoyo-san(Jiaweixiaoyaosan) on Anxiety of Generalized Anxiety disorder (범불안장애의 불안증상에 대한 가미소요산의 제형별 효능 비교 임상연구의 중간보고)

  • Lim, Jung-Hwa;Seo, Bok-Nam;Lee, Sang-Ryong;Jung, In-Chul
    • Journal of Oriental Neuropsychiatry
    • /
    • v.21 no.3
    • /
    • pp.29-44
    • /
    • 2010
  • Objectives : The purpose of this research is to examine the efficacy of Gamisoyosan on anxiety of generalized anxiety disorder according to dosage form. Methods : In this randomized, double blinded, placebo-controlled study, we planned to give Gamisoyosan simple extract mixture or Gamisoyosan compound extract or controlled medication for major symptoms of generalized anxiety disorder. As preparatory research, Hamilton rating Scale for Anxiety(HAM-A) was measured as the 1st evaluative instrument, and Korean State-Trait Anxiety Inventory(STAI-K), Penn State Worry Questionnaire(PSWQ) Korean Beck's Depression Inventory (BDI-K), Symptom Checklist-90-Revised(SCL-90R), WHO Quality of Life Abbreviated(WHOQOL-BREF) and Heart Rate Variability(HRV) were also measured as the 2nd evaluative instrument at the before treatment. Results : Demographic characteristics showed that there are Clinical characteristics-vital signs are within the normal range. The characteristics of disease-chief complaint, pattern Identification and etiological factor of the highest frequency number were worry, heart deficiency with timidity(心膽虛怯), family matters. The average period of disease in subjects is 6.31years. The results of Chest PA, EKG and clinicopathologic examination are within the reference range. The Scores of HAM-A, STAI-K, PSWQ were measured above the cutoff point. There are significant positive correlations among HAM-A, STAI-K, BDI-K and among HAM-A, STAI-K, PSWQ. There are no significant correlations between PSWQ and BDI-K. Conclusions : We considered that selection of subjects in this research is appropriately accomplished And this methodology is expected to be applied to the subsequent research. And also, we hope to make up for this study through various study and discussion.

Disposable Type Electrochemical Ethanol Sensor (일회용 전기화학적 에탄올 센서)

  • Kim, Moon Hwan;Yoo, Jae Hyun;Oh, Hyun Joon;Cha, Geun Sig;Nam, Hakhyun;Park, Sung Woo;Kim, Young Man
    • Analytical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.218-223
    • /
    • 1999
  • A single use, screen-printed sensor for the measurement of liquid phase ethanol was developed and its electrochemical performance was investigated. Disposable type edthanol sensor was fabricated by serially screen printing the carbon paste, silverd pasted and insulator inlon a polyester substrate to pattern working and reference electrode sites and electrical contact. Alcohol dehydrogenase(ADH) or alcohol oxidase(AOD) together with appropriate electron transfer mediators was immobilized on the working electrode. To improve the sensitivity and reproducibility of carbon paste electrode, some pretreatment procedures were applied and their resultant electrochemical performance was examined. The disposable type electrochemical ethanol sensor developed in this study conveniently determines the ethanol in liquid samples such as blood and in fermentation process.

  • PDF

Evaluation of Passive Monitor for the Measuring of Personal Exposure to Nitrogen Dioxide in Indoor and Outdoor Air (실내 및 실외 공기중 이산화질소의 개인 노출량 측정을 위한 수동식 시료채취기의 성능평가)

  • 양원호;이기영;백도명
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.625-631
    • /
    • 2000
  • Practical devices for measuring personal exposure to nitrogen dioxide(NO$_2$) have been made for epidemiological studies of the health effects of air pollution Standard methods for NO$_2$ measurement such as the chemiluminescent method and Saltzman method are not suitable for personal exposure because they are heavy, large and complicated to operate. In this study, a passive monitor was tested for the measurements of indoor and outdoor NO$_2$ level. Through a comparative analysis of data sets obtained by on-site chemiluminescence system, we assessed the accuracy and precision of NO$_2$ passive monitors. We also examined the possibility of passive monitor in the study of indoor, outdoor and personal NO$_2$ exposure. The accuracy and precision of NO$_2$ passive monitor were analyzed assuming measurements of on-site chemiluminescence system is reference value and using duplicated measure- ments, respectively. From these analysis the NO$_2$ passive monitor was useful for measuring indoor, outdoor and personal exposure. And NO$_2$ level from on-site chemiluminescence systems could not properly represent the personal NO$_2$ exposure as well as indoor and outdoor level of ones house. Personal exposures were correlated more strongly with indoor NO$_2$ concentrations than with outdoor NO$_2$ concentrations. Since activity pattern of each person is different, it was considered that personal daily behavior and life-style might prevent the air pollutant exposure.

  • PDF

Serological characteristics and antigenicities of Vibrio harveyi isolated from marine cultured fish (해산어류에서 분리된 Vibrio harveyi의 혈청학적 특성과 항원성)

  • Oh, Yun-Kyeong;Kim, Myoung-Sug;Park, Myoung-Ae;Kim, Jin-Woo;Cho, Ji-Young;Jeong, Hyun-Do
    • Journal of fish pathology
    • /
    • v.22 no.1
    • /
    • pp.23-33
    • /
    • 2009
  • Vibrio harveyi was a significant pathogenic agent and cause a high mortality of cultured fish and shrimp in the aquaculture industry. In this study, we have investigated biochemical, physiological, serological and immunological characteristics of V. harveyi isolated from marine cultured fish. The phenotypes of V. harveyi were differentiated with their own biochemical characteristics and colors of colony on the TCBS agar. V. harveyi were classified into more than four serogroups by agglutination test. Most isolates were classified into a group A which is categorized with the same band pattern generated by western blotting. Group A was characterized by a major protein, which is ranged from 26 and 34 kDa in size, and has a virulence to oliver flounder more than reference strain KCCM40866. Oliver flounders vaccined with FKC of V. harveyi C05011 were highly resistant to infection by other strains of group A.

The Relation of the Videotex Systems and Library Services (비디오텍스 시스템과 도서관 봉사간의 관계)

  • Sung Kee-Joo
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.24
    • /
    • pp.171-204
    • /
    • 1993
  • The purpose of this study is to verify the hypothesis that the contents and range of library services are changed as the use of videotex systems increases. 1000 members of Chollian II were chosen as subjects for this study and the questionnaire was posted to them. The returned responses to questionnaire were analyzed with the statistical software packages 'SAS PC' and 'STATGRAPHICS'. The findings and conclusions of this study are summarised as follows: 1. Users of Chollian II make more use of videotex systems in seeking daily information than in seeking scholarly and professional information. It seems desirable to co-ordinate the services of videotex systems and libraries by redefining the traditional boundary of the two systems. Users will then conveniently get daily information through videotex servics, scholarly and professional information through the reference service of libraries. 2. Sex does not make any significant difference in the use of videotex systems. Most frequent use of videotex systems is made by those at the age of thirties. Businessmen and enterprisers make the most frequent use of videotex systems. Those of higher education are the best users. 3. As the use of videotex systems increases, use of newspapers and periodicals decreases while its increase rarely has influence on the use of library materials. 4. There is limited correlation between the use of videotex systems and that of library services. The increase of the use of videotex systems does not significantly increase or decrease the use of libraries. It changes, however, the pattern and methods of information services provided by libraries. 5. Users of special libraries make the most frequent use of videotex systems and there is not much difference in the use by users of other kinds of libraries.

  • PDF

Numerical simulation on mining effect influenced by a normal fault and its induced effect on rock burst

  • Jiang, Jin-Quan;Wang, Pu;Jiang, Li-Shuai;Zheng, Peng-Qiang;Feng, Fan
    • Geomechanics and Engineering
    • /
    • v.14 no.4
    • /
    • pp.337-344
    • /
    • 2018
  • The study of the mining effect influenced by a normal fault has great significance concerning the prediction and prevention of fault rock burst. According to the occurrence condition of a normal fault, the stress evolution of the working face and fault plane, the movement characteristics of overlying strata, and the law of fault slipping when the working face advances from footwall to hanging wall are studied utilizing UDEC numerical simulation. Then the inducing-mechanism of fault rock burst is revealed. Results show that in pre-mining, the in situ stress distribution of two fault walls in the fault-affected zone is notably different. When the working face mines in the footwall, the abutment stress distributes in a "double peak" pattern. The ratio of shear stress to normal stress and the fault slipping have the obvious spatial and temporal characteristics because they vary gradually from the higher layer to the lower one orderly. The variation of roof subsidence is in S-shape which includes slow deformation, violent slipping, deformation induced by the hanging wall strata rotation, and movement stability. The simulation results are verified via several engineering cases of fault rock burst. Moreover, it can provide a reference for prevention and control of rock burst in a fault-affected zone under similar conditions.

A Study on the Direct Pole Placement PID Self-Tuning Controller Design for DC Servo Motor Control (직류 서어보 전동기 제어를 위한 직접 극배치 PID 자기동조 제어기의 설계)

  • Nam, Moon-Hyun;Rhee, Kyu-Young
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.2
    • /
    • pp.55-64
    • /
    • 1990
  • This paper concerned about a study on the direct pole placement PID self-tuning controller design for DC servo motor control system. The method of a direct pole placement self-tuning PID control for a DC servo motor of Robot manipulator tracks a reference velocity in spite of the parameters uncertainties in nonminimum phase system. In this scheme, the parameters of classical controller are estimated by the recursive least square (RLS)identification algorithm, the pole placement method and diophantine equation. A series of simulation in which minimum phase system and nonminimum phase system are subjected to a pattern of system parameter changes is presented to show some of the features of the proposed control algorithm. The proposed control algorithm which shown are effective for the practical application, and experiments of DC servo motor speed control for Robot manipulator by a microcomputer IBM-PC/AT are performed and the results are well suited.

  • PDF

A Musical Symbol recognition By Using Graphical Distance Measures (그래프간 유사도 측정에 의한 음악 기호 인식)

  • Jun, Jung-Woo;Jang, Kyung-Shik;Heo, Gyeong-Yong;Kim, Jai-Hie
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.54-60
    • /
    • 1996
  • In most pattern recognition and image understanding applications, images are degraded by noise and other distortions. Therefore, it is more relevant to decide how similar two objects are rather than to decide whether the two are exactly the same. In this paper, we propose a method for recognizing degraded symbols using a distance measure between two graphs representing the symbols. a symbol is represented as a graph consisting of nodes and edges based on the run graph concept. The graph is then transformed into a reference model graph with production rule containing the embedding transform. The symbols are recognized by using the distance measure which is estimated by using the number of production rules used and the structural homomorphism between a transformed graph and a model graph. the proposed approach is applies to the recognition of non-note musical symbols and the result are given.

  • PDF