Use of Nuclear Magnetic Resonance Spectroscopy in Analysis of Fennel Essential Oil

  • AbouZid, Sameh
    • Natural Product Sciences
    • /
    • 제22권1호
    • /
    • pp.30-34
    • /
    • 2016
  • A simple and rapid method based on proton nuclear magnetic resonance spectroscopy was developed for determination of trans-anethole content in fennel essential oil. Spectra of pure trans-anethole, of the pure essential oil of fennel, and of the pure oil of fennel with thymol internal standard were recorded. The signal of $H-1^/$ was used for quantification of trans-anethole. This proton signal is well separated in the proton magnetic resonance spectrum of the compound. No reference compound is needed and cheap internal standard was used. The results obtained from spectroscopic analysis were compared with those obtained by gas chromatography. Additionally, the developed method was used for determination of the type of vegetable oil used as a carrier in commercial products, which cannot be quantified as such by gas chromatography. This study demonstrates the application of proton nuclear magnetic resonance spectroscopy as a quality control method for estimation of essential oil components.

저열량 가스 적용에 따른 천연가스엔진의 대응 방안 연구 (Countermeasures to the Introduction of Low Caloric Gas Fuel for Natural Gas Engine)

  • 박철웅;김창기;오세철;이장희
    • 한국가스학회지
    • /
    • 제25권2호
    • /
    • pp.34-41
    • /
    • 2021
  • 국내에서 사용되는 천연가스가 저열량화 되면서 발생할 수 있는 문제점에 대응하기 위해서는 국내 산업용 가스기기에 미칠 수 있는 문제점을 사전에 파악하고, 이를 기반으로 에너지의 효율적인 사용을 위한 대응방안이 선행되어야 한다. 본 연구에서는 EURO-6 규제를 대응하는 희박연소방식의 천연가스 엔진을 이용할 경우, 저열량 가스의 도입으로 인한 엔진 출력성능과 효율의 저하 문제를 해결하기 위해, 실험을 토대로 한 구체적인 제어방안과 결과를 제시하고자 하였다. 전부하 운전조건인 1,400 rpm의 엔진 회전수에서 스로틀이 전부 개방된 전부하 조건과 정격운전조건의 엔진회전수인 2,100 rpm, 450 Nm의 토크 조건에서 점화시기로 대표되는 제어변수에 의한 개선효과 확인을 위해, 각 가스연료에 대해서 점화시기를 변경하여 열효율 및 배출가스특성을 파악하고 최적화하였다. 전부하조건에서 토크를 기준으로 가장 낮은 값을 보이는 순수메탄의 경우 기준 조건에서 약 2 CAD 정도 점화시기를 진각하면 NOx 배출의 큰 증가 없이 토크를 보상할 수 있다.

천연가스의 탄화수소 및 물 이슬점 계산 (Calculation of the Hydrocarbon and Water Dew points of Natural Gas)

  • 하영철;이성민;허재영;이강진;이승준
    • Korean Chemical Engineering Research
    • /
    • 제47권5호
    • /
    • pp.565-571
    • /
    • 2009
  • 본 연구에서는 천연가스의 탄화수소 이슬점과 물 이슬점을 계산하고자 하였다. 이를 위해 임계압력 근방까지 탄화수소 이슬점이 계산되도록 발산 방지 로직을 고안하였고 물 이슬점의 대해서는, 상용프로그램과 달리 탄화수소 이슬점 이하에서도 이슬점이 계산될 수 있도록 로직을 개발하였다. 그리고 계산결과는 국외 상용프로그램 및 ISO와 비교하였으며 차이는 없는 것으로 나타났다.

DNA-functionalized single-walled carbon nanotube-based sensor array for gas monitoring

  • Zhang, Wenjun;Liu, Yu;Wang, Ming. L
    • Smart Structures and Systems
    • /
    • 제12권1호
    • /
    • pp.73-95
    • /
    • 2013
  • Nine deoxyribonucleic acid (DNA) sequences were used to functionalize single-walled carbon nanotube (SWNT) sensors to detect the trace amount of methanol, acetone, and HCl in vapor. DNA 24 Ma (24 randomly arranged nitrogenous bases with one amine at each end of it) decorated SWNT sensor and DNA 24 A (only adenine (A) base with a length of 24) decorated SWNT sensor have demonstrated the largest sensing responses towards acetone and HCl, respectively. On the other hand, for the DNA GT decorated SWNT sensors with different sequence lengths, the optimum DNA sequence length for acetone and HCl sensing is 32 and 8, separately. The detection of methanol, acetone, and HCl have identified that DNA functionalized SWNT sensors exhibit great selectivity, sensitivity, and repeatability with an accuracy of more than 90%. Further, a sensor array composed of SWNT functionalized with various DNA sequences was utilized to identify acetone and HCl through pattern recognition. The sensor array is a combination of four different DNA functionalized SWNT sensors and two bare SWNT sensors (work as reference). This wireless sensing system has enabled real-time gas monitoring and air quality assurance for safety and security.

상압 용융탄산염 연료전지와 가스터빈을 결합한 하이브리드 시스템의 성능설계 해석 (Performance Design Analysis of Hybrid Systems Combining Atmospheric Pressure Molten Carbonate Fuel Cell and Gas Turbine)

  • 정영현;김동섭
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1361-1369
    • /
    • 2003
  • Design performance of hybrid power generation systems, comprised of a gas turbine and an atmospheric pressure molten carbonate fuel cell, has been analyzed. Two different configurations were analyzed and performances were compared. A reference calculation was performed for the design condition of a system under development and simulated results agreed well with the published data. Performances were analyzed in terms of main design parameters including turbine inlet temperature, operating temperature of the fuel cell and pressure ratio. Also examined were the effects of fuel utilization factor and heat exchanger effectiveness. It was found that the relationship between the turbine inlet temperature and the fuel cell temperature should be critically examined to evaluate achievable design performance. Considering current state of the art technologies, a system with the combustor located before the turbine could achieve higher efficiency and specific power than the other system with the combustor located after the turbine.

열량형 질량 유량계의 성능 평가 (A Study on the Performance of Thermal Mass Flowmeter)

  • 최용문;박경암;윤복현;장석;최해만;이생희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.595-600
    • /
    • 2001
  • Thermal mass flow meter(TMF) and thermal mass flow controller(MFC) were used to measure and to control the mass flow rate of gases. TMF and MFC were designed for specified working pressure and gas. For the case of different working pressure and gases, the flow rate measurement accuracy decreased dramatically. In this study, a TMF and MFC was tested with three different gases and pressure range from 0.2 MPa up to 1.0 MPa. Effect of specific heat causes to increase flow measurement error as much as ratio of specific heat compared with reference gas. Changing of pressure causes to increase flow rate measurement error about -0.2% as the working pressure decreased 0.1 MPa. Response time of MFC was below 3.12 s for the case of increasing of flow rate. But the response time was increased up to 6.92 s for the case of decreasing of flow rate. When the solenoid valve was fully closed, a initial delay time of output of MFC was increased up to 1.36 s.

  • PDF

마이크로 가스터빈 설계 및 운전 성능 분석 : 제2부 - 압축기와 터빈 성능저하에 의한 엔진 운전 및 성능변화 (Analysis of Design and Operation Performance of Micro Gas Turbine : Part 2 - Variations in Engine's Operation and Performance Caused by Performance Degradation of Compressor and Turbine)

  • 김정호;김민재;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제18권4호
    • /
    • pp.30-35
    • /
    • 2015
  • This study analyzed the variations in the performance and operation of a 200 kW class micro gas turbine according to performance degradation of compressor and turbine. An in-house code, developed by the present authors and presented in the first part of these series of papers, were used for the analysis. The degradation of compressor and turbine were simulated by modifications in the their performance maps: mass flow rate, pressure ratio and efficiency were decreased from the reference values. Firstly, the variations in the operating conditions (air flow rate, pressure ratio) were predicted for the full load condition. Then, the same analysis were performed for a wide partial load operating range. The change in engine's performance (power output and efficiency) due to the component degradation was predicted. In addition, the change in the compressor surge margin, which is an important indicator for safe engine operation, was evaluated.

좁은밴드모델을 이용한 실린더 내의 비회색 가스 복사열전달 연구 (Study on Nongray Gas Radiation within a Cylindrical Enclosure by Using the Narrow Band Model)

  • 박원희;정현성;김태국
    • 대한기계학회논문집B
    • /
    • 제26권6호
    • /
    • pp.859-867
    • /
    • 2002
  • Radiative transfer in energy systems such as furnaces, combustors, boilers and high temperature machineries is a significant mode of heat transfer. Although there are many solution schemes suggested for analysis of radiative transfer in multi-dimensional systems, the applicabilities and accuracies of these schemes have not fully tested for nongray gases. Especially reference data for enclosures of non-orthogonal shapes are not yet enough. In this paper we present some precise radiative transfer solutions for a black walled 3-dimensional cylindrical system filled with nongray gases. The SNB(statistical narrow band) model and the ray-tracing method with the T$_{N}$ quadrature set are used for finding nongray solutions. Although the solution method used in this study is not suitable for engineering purposes, the resulting solutions are proved to be quite accurate and can be regarded as the exact solutions and the results presented in this paper can be used in developing various solution schemes fur radiative transfer by real gas mixtures.s.

가상체적을 이용한 폭발위험장소 구분의 타당성 검토 (Validity Review on Classification of Explosion Hazardous Area using Hypothetic Volume)

  • 임지표;정창복
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.68-75
    • /
    • 2014
  • It is very important to classify explosion hazardous area (EHA) suitably and to use proper explosion-proof electric installations for facilities using flammable gases and liquids. In the past, various examples in the Notification of Ministry of Employment and Labor were referred to in classifying EHA. But, at present, many companies use the hypothetical volume in Korean Standards (KS). This study reviews the validity of EHA classification based on the hypothetical volume by comparing the calculated radii of EHA with those obtained by a consequence analysis program called PHAST and a mathematical approach in British Standards (BS). The radii of EHA by the hypothetical volume were found to be slightly larger than those by the other two methods. This was attributed to rather conservative uses of a safety factor(k) and a correction factor(f) for availability of ventilation in calculating the hypothetical volume. Since the differences are not so conspicuous, however, it is concluded that the hypothetical volume in KS is a valid means for the classification of EHA. This study also presents a table of the radii of EHA for easy reference by small-scale companies using city gas, C3-LPG and flammable liquid(toluene), respectively. The table consists of 25 leakage scenarios corresponding to combinations of 5 pipe(nozzle) sizes and 5 operating conditions for each flammable gas and liquid.

Infrared Light Absorbance: a New Method for Temperature Compensation in Nondispersive Infrared CO2 Gas Sensor

  • Yi, Seung Hwan
    • 센서학회지
    • /
    • 제29권5호
    • /
    • pp.303-311
    • /
    • 2020
  • Nondispersive infrared CO2 gas sensor was developed after the simulation of optical cavity structure and assembling the optical components: IR source, concave reflectors, Fresnel lens, a hollow disk, and IR detectors. By placing a hollow disk in front of reference IR detector, the output voltages are almost constant value, near to 70.2 mV. The absorbance of IR light, Fa, shows the second order of polynomial according to ambient temperatures at 1,500 ppm. The differential output voltages and the absorbance of IR light give a higher accuracy in estimations of CO2 concentrations with less than ± 1.5 % errors. After implementing the parameters that are dependent upon the ambient temperatures in microcontroller unit (MCU), the measured CO2 concentrations show high accuracies (less than ± 1.0 %) from 281 K to 308 K and the time constant of developed sensor is about 58 sec at 301 K. Even though the estimation errors are relatively high at low concentration, the developed sensor is competitive to the commercial product with a high accuracy and the stability.