• Title/Summary/Keyword: Reference fuel

Search Result 324, Processing Time 0.025 seconds

A Study on Propulsion Control Device Characteristics of Small-scale Electric Railway Vehicle according to Driving Curve Tracking using Fuel Cell Generation System (연료전지 발전시스템을 이용한 축소형 철도차량의 운전곡선 추종에 따른 추진제어장치 특성 고찰)

  • Jung, No-Geon;Chang, Sang-Hoon;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1804-1809
    • /
    • 2015
  • The study in railway system to apply a fuel cell system with high efficiency and mobility than other renewable energy is being actively conducted. It is needed a analysis on load characteristics and control method of rolling stock in order to apply to rolling stock. This paper presents study on control small-scale prototype power converter electric railway vehicle using fuel cell generation system. Experiment is conducted through real fuel cell generation system and reference speed applying the driving curve of the actual electric railway vehicle was applied. Also, output voltage of boost converter is controlled considering characteristic of fuel cell. And it was confirmed characteristic according to powering and regeneration of inverter.

A Systematic Approach for Mechanical Integrity Evaluation on the Degraded Cladding Tube of Spent Nuclear Fuel Under Transportation Pinch Force

  • Lee, Seong-Ki;Park, Joon-Kyoo;Kim, Jae-Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.3
    • /
    • pp.307-322
    • /
    • 2021
  • This study developed an analytical methodology for the mechanical integrity of spent nuclear fuel (SNF) cladding tubes under external pinch loads during transportation, with reference to the failure mode specified in the relevant guidelines. Special consideration was given to the degraded characteristics of SNF during dry storage, including oxide and hydride contents and orientations. The developed framework reflected a composite cladding model of elastic and plastic analysis approaches and correlation equations related to the mechanical parameters. The established models were employed for modeling the finite elements by coding their physical behaviors. A mechanical integrity evaluation of 14 × 14 PWR SNF was performed using this system. To ensure that the damage criteria met the applicable legal requirements, stress-strain analysis results were separated into elastic and plastic regions with the concept of strain energy, considering both normal and hypothetical accident conditions. Probabilistic procedures using Monte Carlo simulations and reliability evaluations were included. The evaluation results showed no probability of damage under the normal conditions, whereas there were small but considerably low probabilities under accident conditions. These results indicate that the proposed approach is a reliable predictor of SNF mechanical integrity.

A Study on the Influence of Test Temperature & Cooling Fan Condition on the Fuel Test of Diesel Vehicle (디젤차량 연비시험에 있어 시험온도 및 냉각팬 조건이 미치는 영향분석에 관한 연구)

  • Kim, Hyun-Jin;Kim, Sung-Woo;Lim, Jae-Hyuk;Noh, Kyung-ha;Lee, Jung-Cheon;Kim, Ki-Ho;Oh, Sang-Gi
    • Journal of Power System Engineering
    • /
    • v.21 no.6
    • /
    • pp.46-55
    • /
    • 2017
  • Due to the arise of natural disasters caused by global warming, consumers have more interest in the fuel efficiency of their vehicles, and fuel efficiency became an important factor in comparing vehicles. In this market situation, methods to measure fuel efficiency has become one of the main interests of vehicle related organizations and laboratories, and the current method to measure fuel efficiency is to follow the notification established by the ministry of trade, industry and energy, ministry of environment, and the ministry of land, infrastructure and transport. In this study, we analyze the influence of vehicle fuel efficiency according to test temperature and cooling fan condition which have the possibility to cause difference in fuel efficiency. The analysis results of the influence of the fuel efficiency according to the test temperature, the difference of the fuel efficiency of the test temperature ($21{\sim}29^{\circ}C$) within the allowable range of the notification showed a maximum difference of 2.9%. Therefore, it is necessary to consider the introduction of a test method that permits only the temperature change based on the reference point as the allowable range even in the test within the allowable range. The analysis of the influence of the fuel efficiency according to the cooling method showed no significant effect, and it seems reasonable to maintain the test method of the current notification.

Development of a Simplified Source Term Estimation Model for a Spent Fuel from Westinghouse-type Reactors (웨스팅하우스형 원전 사용후핵연료에 대한 방사선원항 예측 모델 개발)

  • Cho, Dong-Keun;Kook, Dong-Hak;Choi, Heui-Joo;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.239-245
    • /
    • 2010
  • There are 11,811 LWR spent fuels stored at reactor sites, as of 2009. Source terms based on reference spent fuel which represents entire spent fuels with bounding values in the aspect of source term has been applied to a design of nuclear installations, instead of those which are generated by weighting respective source term for each spent fuel. Simplified regression models to estimate total decay heat, radioactivity, and ingestion hazard index for spent fuel from Westinghouse-type reactors were developed in this study, because it can be used as a fundamental model for weighting source term for respective spent fuel to exclude conservativeness in source terms. It was found that the estimated source terms agreed with calculated value from ORIGEN-ARP within 5%. It was also found that the conservativeness could be excluded if the weight source terms were used as reference source term in the design. Therefore, it is expected that the developed regression model could be widely used in the conceptual design process of nuclear facilities related with storage and disposal of spent nuclear fuel.

Reference Electrode at Molten Salt: A Comparative Analysis of Electroceramic Membranes

  • Yoon, Seokjoo;Kang, Dokyu;Sohn, Sungjune;Park, Jaeyeong;Lee, Minho;Choi, Sungyeol
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.143-155
    • /
    • 2020
  • A reference electrode is important for controlling electrochemical reactions. Evaluating properties such as the reduction potential of the elements is necessary to optimize the electrochemical processes in pyroprocessing, especially in a multicomponent environment. In molten chloride systems, which are widely used in pyroprocessing, a reference electrode is made by enclosing the silver wire and molten salt solution containing silver chloride into the membranes. However, owing to the high temperature of the molten salt, the choice of the membrane for the reference electrode is limited. In this study, three types of electroceramic, mullite, Pyrex, and quartz, were compared as reference electrode membranes. They are widely used in molten salt electrochemical processes. The potential measurements between the two reference electrode systems showed that the mullite membrane has potential deviations of approximately 50 mV or less at temperatures higher than 650℃, Pyrex at temperatures lower than 500℃, and quartz at temperatures higher than 800℃. Cyclic voltammograms with different membranes showed a significant potential shift when different membranes were utilized. This research demonstrated the uncertainties of potential measurement by a single membrane and the potential shift that occurs because of the use of different membranes.

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(III) - Contribution and distribution characteristics of air pollutants according to elemental carbon, crystalline silica, and stable isotope ratio - (대구 안심연료단지 환경오염물질 노출 평가(III) - 원소 탄소, 결정형 실리카 및 안정동위원소비를 이용한 오염원 기여율 및 분포특성 -)

  • Jung, Jong-Hyeon;Phee, Young-Gyu;Shon, Byung-Hyun;Bae, Hye-Jeong;Yang, Won-Ho;Kim, Ji-Young;Kim, Geun-Bae;Choi, Jong-Woo;Park, Sung-Jun;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.392-404
    • /
    • 2015
  • Objectives: This study measured and analyzed the concentrations of crystalline silica, elemental carbon and the contribution ratio of pollutants which influence environmental and respiratory disease around the Ansim Briquette Fuel Complex in Daegu, Korea. Methods: We analyzed the crystalline silica and elemental carbon in the air according to FTIR(Fourier Transform Infrared Spectroscopy) and NIOSH(National Institute of Occupation Safety and Health) method 5040, respectively. In addition, lead stable isotopes, and carbon and nitrogen stable isotopes were analyzed using MC-ICP/MS(Multi Collector-Inductively Coupled Plasma/Mass Spectrometer), and IRMS(Isotope Ratio Mass Spectrometer), respectively. Results: The concentration of crystalline silica in the direct exposure area around the Ansim Briquette Fuel Complex was found to be $0.0014{\pm}0.0005mg/Sm^3$, but not to exceed the exposure standards of the ACGIH(American Conference of Governmental Industrial Hygienists). In the case of the autumn, the direct exposure area was found to show a level 2.5 times higher than the reference area, and on the whole, the direct exposure area was found to have a level 1.4 times higher than the reference area. The concentration of elemental carbon in the direct exposure area and in the reference area were found to be $0.0014{\pm}0.0006mg/Sm^3$, and $0.0006{\pm}0.0003mg/Sm^3$, respectively. This study confirmed the contribution ratio of coal raw materials to residentially deposited dusts in the area within 500 meters from the Ansim Briquette Fuel Complex and the surrounding area with a stable isotope ratio of 24.0%(0.7-62.7%) on average in the case of carbon and nitrogen, and 33.9%(26.6-54.1%) on average in the case of lead stable isotopes. Conclusions: This study was able to confirm correlations with coal raw materials used by the Ansim Briquette Fuel Complex and the surrounding area. The concentration of some pollutants, crystalline silica, and elemental carbon emitted to the direct-influence area around the Ansim Briquette Fuel Complex were relatively higher than in the reference area. Therefore, we need to impose continuous and substantive reduction countermeasures in the future to prevent particulate matter and coal raw materials in the study area. It is time for the local government and authorities to prepare active administrative methods such as the relocation of Ansim Briquette Fuel Complex.

Safety Assessment on Long-term Radiological Impact of the Improved KAERI Reference Disposal System (the KRS+)

  • Ju, Heejae;Kim, In-Young;Lee, Youn-Myoung;Kim, Jung-Woo;Hwang, Yongsoo;Choi, Heui-joo;Cho, Dong-Keun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.spc
    • /
    • pp.75-87
    • /
    • 2020
  • The Korea Atomic Energy Research Institute (KAERI) has developed geological repository systems for the disposal of high-level wastes and spent nuclear fuels (SNFs) in South Korea. The purpose of the most recently developed system, the improved KAERI Reference Disposal System Plus (KRS+), is to dispose of all SNFs in Korea with improved disposal area efficiency. In this paper, a system-level safety assessment model for the KRS+ is presented with long-term assessment results. A system-level model is used to evaluate the overall performance of the disposal system rather than simulating a single component. Because a repository site in Korea has yet to be selected, a conceptual model is used to describe the proposed disposal system. Some uncertain parameters are incorporated into the model for the future site selection process. These parameters include options for a fractured pathway in a geosphere, parameters for radionuclide migration, and repository design dimensions. Two types of SNF, PULS7 from a pressurized water reactor and Canada Deuterium Uranium from a heavy water reactor, were selected as a reference inventory considering the future cumulative stock of SNFs in Korea. The highest peak radiological dose to a representative public was estimated to be 8.19×10-4 mSv·yr-1, primarily from 129I. The proposed KRS+ design is expected to have a high safety margin that is on the order of two times lower than the dose limit criterion of 0.1 mSv·yr-1.

A Robust PLL of PCS for Fuel Cell System under Unbalanced Grid Voltages (불평형 계통전압에 강인한 연료전지용 전력변환시스템의 PLL 방법)

  • Kim, Yun-Hyun;Kim, Wang-Rae;Lim, Chang-Jin;Kim, Kwang-Seob;Kwon, Byung-Ki;Choi, Chang-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.103-105
    • /
    • 2008
  • In grid-interconnection system, a fast, robust and precise phase angle detector is most important to grid synchronization and the active power control. The phase angle can be easily estimated by synchronous dq PLL system. On the other hand under unbalanced voltage condition, synchronous dq PLL system has problem that harmonics occur to phase angle or magnitude of grid voltage because of the effect of the negative sequence components. So, To eliminate the negative sequence components, the PLL method using APF (All Pass Filter) in a stationery reference frame to extract positive sequence components under unbalanced voltage condition is researched. In this paper, we propose a new PLL method with decoupling network using APF in a synchronous reference frame to extract the positive sequence components of the grid voltage under unbalanced grid. The cut-off frequency of APF in a synchronous reference frame can be set to twice of the fundamental frequency comparing with that of APF in a stationery reference frame which is the fundamental frequency. The proposed PLL strategy can detect the phase angle quickly and accurately under unbalanced gird voltages. Simulation and experimental results are presented to verify the proposed strategy under different kind of voltage dips.

  • PDF

Design and Implementation of Green Light Optimal Speed Advisory Based on Reference Mobility Models (GLOSA-RMM) in Cyber-Physical Intersection Systems (CPIS) (사이버-물리 교차로 시스템에서 참조이동모형 기반 녹색신호 최적화 가속도 조언의 설계 및 구현)

  • Jeong, Han-You;Suramardhana, Tommy Adhyasa;Nguyen, Hoa-Hung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.8
    • /
    • pp.544-554
    • /
    • 2014
  • In this paper, we introduce a cyber-physical intersection systems (CPIS) which intimately interconnects roadside units (RSU) located at intersection, on-board units (OBU) of moving vehicles, and smartphone apps. Based on the architecture of CPIS, we also present a green light optimal speed advisory based on the reference mobility models (GLOSA-RMM) to reduce intersection stopping time (IST) and fuel consumption. Based on several reference mobility models, the GLOSA-RMM determines the appropriate speed advisory by taking into account the current mobility and the intersection traffic light status, and then provides screen/voice GLOSA instructions to minimize the driver's distraction. We show that the GLOSA-RMM can reduce both the IST and the fuel consumption through the numerical results obtained from the prototype of the CPIS consisting of the OBU, the RSU and the smartphone app.

Performance Design Analysis of Hybrid Systems Combining Atmospheric Pressure Molten Carbonate Fuel Cell and Gas Turbine (상압 용융탄산염 연료전지와 가스터빈을 결합한 하이브리드 시스템의 성능설계 해석)

  • Jeong, Young-Hyun;Kim, Tong-Soep
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1361-1369
    • /
    • 2003
  • Design performance of hybrid power generation systems, comprised of a gas turbine and an atmospheric pressure molten carbonate fuel cell, has been analyzed. Two different configurations were analyzed and performances were compared. A reference calculation was performed for the design condition of a system under development and simulated results agreed well with the published data. Performances were analyzed in terms of main design parameters including turbine inlet temperature, operating temperature of the fuel cell and pressure ratio. Also examined were the effects of fuel utilization factor and heat exchanger effectiveness. It was found that the relationship between the turbine inlet temperature and the fuel cell temperature should be critically examined to evaluate achievable design performance. Considering current state of the art technologies, a system with the combustor located before the turbine could achieve higher efficiency and specific power than the other system with the combustor located after the turbine.