• Title/Summary/Keyword: Reference Material

Search Result 1,336, Processing Time 0.032 seconds

Development of certified reference material (CRM)s for surface analysis I : alloy thin film for surface compositional analysis (표면분석용 인증표준물질의 개발 I : 표면조성분석용 합금박막 표준물질)

  • 김경중;박용섭;문대원
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.3B
    • /
    • pp.276-282
    • /
    • 1999
  • For the quantitative surface analysis of multicomponent materials, algorithms for the compensation of the matrix effect and surface compositional change by ion beam sputtering must be established and reference materials having certified compositions are necessary. These certified reference material (CRM)s are needed for the improvement of instrument performance, inter-laboratory comparison and quantitative surface analysis. Surface analysis group of KRISS developed alloy thin film CRMs by and ion beam sputter deposition system and in-situ surface analysis system to control the composition of alloy thin films The real compositions of the CRMs were certified by inductively coupled plasma-atomic emission spectroscopy (ICP-AES).

  • PDF

Instantaneous Following PWM Control Strategy of Cuk Converter Using Integrator (적분기를 이용한 Cuk 컨버터의 순시추종형 PWM 제어)

  • Shon, Je-Bong;Jeong, Soon-Yang;Kim, Kwang-Tae;Lee, Woo-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.103-105
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of Cuk converter. In this control method, the duty ratio of a switch is exactly equal to or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with Cuk converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM.

  • PDF

Design of Readout IC for Uncooled Infrared Bolometer Sensor using Bias Offset Correction Technique (오프셋 보정 기술을 이용한 비냉각형 적외선 센서용 신호검출 회로 설계)

  • Park, Sang-Won;Hwang, Sang-Joon;Hong, Seung-Woo;Jung, Eun-Sik;Sung, Man-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.23-25
    • /
    • 2005
  • Infrared bolometer sensor's variation is detected by voltage drop between reference resistor and bolometer resistor in this architecture. One of the serious problems in this architecture is that these resistors value has a process variation. So common-mode level could be different from expectation in room temperature. Different common-mode level could lead to wrong output at the end of readout circuit. We suggest useful method to solve this problem. Difference correction using capacitor has reduced CM level difference to 86% for 1 $M\Omega$. bolometer and reference resistor's 10% variation.

  • PDF

A Study on the Control of Apartment House Design Factors considering Energy, Environment and Economical Efficiency (에너지, 환경 및 경제성을 통합 고려한 공동주택 설계요소 제어에 관한 연구)

  • Choi, Doo-Sung;Do, Jin-Seok
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.29-38
    • /
    • 2012
  • The current building energy efficiency rating certification regulation on apartment houses evaluates only the saving rate of energy consumed during operation, i.e. use, of a building, but doesn't consider the energy consumptions and environmental load($CO_2$) emissions occurring during the whole lifetime of a building. So this study calculated the energy consumptions and environmental load emissions occurring during the whole lifetime of a building, selected reference schemes and alternative items by design variables to present a design draft considering energy efficiency and environmental performance, and evaluated the total cost by combining and calculating its direct cost(material and heating cost) and indirect cost(environmental cost), for an existing apartment house as an evaluation object. As a result of analysis, the change of heating cost by alternative items of design variables showed a 4~8% change rate compared to the reference scheme, and the material cost of design variable 7 showed a maximum 4.4 times change rate in the alternative plan 6 compared to the reference scheme. The environmental cost showed a similar change rate to the material cost change rate in general, but showed a similar environmental cost change rate to the heating cost change rate in case of design variables 4-1, 4-2, 7.

Active Vibration Control of a Opened Box Structure By a Model Reference Neuro-Controller (모델기반 신경망 제어기를 이용한 열린 박스 구조물의 진동제어)

  • Jang, Seung-Ik;Shen, Yun-De;Kee, Chang-Doo
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1602-1607
    • /
    • 2003
  • Vibration causes noise and sometimes makes structure unstable. Especially, due to the efforts of lightening, deformation of flexible structure is increased in its shape. Just a little disturbance can cause vibration and low damping ratio makes residual vibration last long time. This research is concerned with the model reference neuro-controller design for the vibration suppression of smart structures. By using a model reference neurocontroller, which is one of the algorithms of adaptive control, we performed an adaptive control of flexible cantilever plate and opened box structure with piezoelectric materials. The proposed adaptive vibration control algorithm, a model reference neuro-controller, was proved in its effectiveness by applying to an opened box structure. The model reference neuro-controller is implemented with DSP, and the real-time adaptive vibration control experiment results confirm that the model reference neuro-controller is reliable.

  • PDF

Simulation of Microlens Array for the Improvement of Outcoupled Efficiency of Organic Light-emitting Diodes (유기 발광 소자의 광추출 효율 향상을 위한 마이크로 렌즈 어레이의 시뮬레이션)

  • Hwang, Deok Hyeon;Kim, Hye Sook;Lee, Won Jae;Lee, Seunghun;Kim, Tae Wan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.10
    • /
    • pp.745-753
    • /
    • 2013
  • Performance of organic light-emitting diodes incorporating microlens array was simulated using a Light Tools software. Use of microlens array can help the light to escape out of the device. We simulated a reference device that is consisted of reflection layer, emissive layer, and flat transparent substrate. And in this reference device, outcoupled efficiency of 22% was obtained. Several shapes of microlens were applied such as hemisphere, trapezoid, cone, and rectangular parallelepiped. The results showed the improvement of outcoupled efficiency of the device with microlens compared to that of the reference one. And from the analyses of the simulated data, the obtained appropriate shape of microlens is hemisphere, and the improvement of the device with hemispherical lens is 57% higher than that of the reference one.

A Preliminary Study for a Glass Geological Reference Material Using Obsidian (흑요암을 이용한 유리 지질 표준물질에 대한 예비 연구)

  • Jin, Mi-Eun;Jwa, Yong-Joo;Park, Sang Gu;Sun, Gwang Min
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.1
    • /
    • pp.65-71
    • /
    • 2020
  • Glass reference materials have been essentially used for precise geochemistry analytical techniques. In order to make up for the drawback of synthetic glass reference materials, which have the high uncertainty caused by the difference in composition of natural rocks, we introduce a glass geostandard using natural glass. The NK-B1G sample, which comes from the Baekdusan obsidian, is a natural glassy rock that contains only few crystals such as microlites or inclusions. We examined the feasibility of the sample as a reference material for microanalysis like EPMA or LA-ICPMS.

Influence of Microstructure on Reference Target on Ultrasonic Backscattering (기준표적상의 미세구조가 초음파 후방산란에 미치는 영향)

  • Kim, Ho-Chul;Kim, Yong-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.1E
    • /
    • pp.38-44
    • /
    • 2010
  • This paper is based on our comments and proposed amendments to the documents, Annex A, Phantom for determining Maximum Depth of Penetration, and Annex B, Local Dynamic Range Using Acoustical Test Objects 87/400/CDV. IEC 61391-2 Ed. 1.0 200X, prepared by IEC technical Committee 87; Ultrasonics. The documents are concerned with the influence of microstructure of reference target material on the ultrasonic backscattering. Previous works on the attenuation due to backreflection and backscattering of reference target materials are reviewed. The drawback to the use of ungraded stainless steel and metallic materials without microstructural data such as, crystal structure, basic acoustic data of sound velocity and attenuation, grain size, roughness and elastic constants has been discussed. The analysis suggested that the insightful conclusion can be made by differentiating the influence arising from target size and microstructure on the backscattering measurements. The microstructural parameters are associated with physical, geometrical, acoustical and mechanical origins of variation with frequency. Further clarification of such a diverse source mechanisms for ultrasonic backscattering would make the target material and its application for medical diagnosis and therapy simpler and more reliable.

Development of Methyl 2-aminobenzoate Reference Material in a Biocidal Product Matrix

  • So Yeon Lee;Kyungmin Kim;Junghyun Kim;Wooil Kim;Han Bin Oh
    • Mass Spectrometry Letters
    • /
    • v.14 no.4
    • /
    • pp.166-172
    • /
    • 2023
  • The utilization of methyl 2-aminobenzoate as a biocide and pesticide has raised concerns regarding its potential toxicity. To assess its safety, it is crucial to determine its quantity and related toxicity using reference materials (RMs) or certified reference materials (CRMs). As an RM and CRM containing methyl 2-aminobenzoate within a biocidal product matrix is currently unavailable, this study aimed to produce a high-quality RM containing methyl 2-aminobenzoate, ensuring its homogeneity and stability, following the ISO Guide 35 and ISO 17034. The study determined that the produced RM exhibited homogeneity, as indicated by a calculated F-value (1.91) smaller than the critical F-value (3.02). In the assessment of isochronous short-term stability, the slope of the linear regression for the RM showed no statistically significant difference from zero when stored at temperatures of 4, 18, and 60 ℃ for 4 weeks. Regarding classical long-term stability, the RM demonstrated sustained stability over the course of one year when stored at 4 ℃. This study has successfully developed an RM for monitoring methyl 2-aminobenzoate in biocides and pesticides. Its quality underwent rigorous evaluation, confirming both homogeneity and stability.

Development of Certified Reference Materials for Analysis of Heavy Metals in Paints to Cope with Environmental Regulations (환경규제 대응을 위한 페인트 중의 중금속 분석용 인증 표준물질 개발)

  • Yu, Byung Kyu;Sun, Yle Shik
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.209-219
    • /
    • 2018
  • In the areas of RoHS, WEEE, ELV and REACH, reinforcement of environmental regulations against harmful substances is a global trend not only in EC but also in all over the world. In the fields of Korea's major export products such as material parts, electrical and electronic products and automobile parts, we are responding to these regulations consistently. To develop reference material for analyzing lead and cadmium in paints, the candidate materials were produced through the screening process which separated shapes and sizes. To secure the traceability of the candidate materials produced, the characteristics and uncertainties are estimated by ICP-AES analysis using the primary reference material. The short-term and long-term stabilities also are evaluated in parallel. In order to calculate the final certification value of the candidate material, the verification were carried out by the performance evaluation through the comparison among the KOLAS (Korea Laboratory Accreditation Scheme) laboratories, and the CRM was produced in accordance with ISO Guide 35. The certified values and uncertainties of Pb and Cd of the final paint standard, determined according to the joint analysis among laboratories, are Pb [($191.4{\pm}3.1$) mg/kg, ($944.1{\pm}5.6$) mg/kg] and Cd [($45.0{\pm}2.6$) mg/kg, ($225.5{\pm}3.5$) mg/kg]. These standard materials were developed to enhance the reliability of measurement analysis, including the validity and traceability of measurement results. Also it is expected that the CRM will be used as QCM (quality control material) for the product design and the process monitoring, so that regulation and management of hazardous heavy metals can be systematically implemented.