• Title/Summary/Keyword: Reference Level in Diagnostic

Search Result 85, Processing Time 0.025 seconds

Fluoroscopy examinations for the management of patient dose study on the establishment of diagnostic reference level (UGI, Esophagography standards) (투시 조영 검사 시 환자 선량 관리를 위한 진단참고선량 구축에 관한 연구 (UGI, Esophagography 기준))

  • Hong, Sun-Suk;Park, Eun-Seong;Cho, Joon-Yeong;Seong, Min-Suk;Yang, Han-Joon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • This round of tests in patients with UGI and Esophagography data collected by national and international reference levels based on the original set of guidelines and fluoroscopy, through the provision of medical radiation exposure reduction and further optimization of Defense to realize that is intended. 359 names in our hospital underwent Esophagography 302 patients who underwent UGI average fluoroscopy time and number of images to calculate the average 21 cm Acryl phantom dose for 10 seconds and 20 seconds, average area dose and the area dose of 1 spot image, 5 spot consecutive images by measuring the patient dose and third quartile of the mean area dose was set seonryangin reference dose. Esophagography average patient dose was set to 30.05 $Gy{\cdot}cm^2$, DRL was set at a 25.37 $Gy{\cdot}cm^2$. Average dose of UGI patients were selected as 45.33 $Gy{\cdot}cm^2$, DRL was set at a 34 $Gy{\cdot}cm^2$. UGI patients with established average dose recommended in the 2008 national recommendation from the UGI examination with a dose of less than 49.7 $Gy{\cdot}cm^2$ seonryangin is evaluated. This Note examines the dose of self-aware through education recognizes the importance of dose reduction and examine if their efforts and further reduce patient dose could achieve optimization of the medical exposure is considered.

  • PDF

Patient exposure doses from medical x-ray examinations in Korea (진단방사선검사에서 환자피폭선량에 관한 연구)

  • Kim, You-Hyun;Choi, Jong-Hak;Kim, Sung-Soo;Oh, Yuw-Han;Lee, Chan-Hyeup;Cho, Pyong-Kon;Kang, Dae-Hyun;Lee, Young-Bae;Kim, Hyung-Chul;Kim, Chel-Min
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.241-248
    • /
    • 2005
  • X-ray examinations represent the largest man-made source of radiation exposure for the population. The need for standardization of radiation exposures has been suggested and the guidance levels for various radiographic and radioisotope examinations has been proposed by the International Atomic Energy Aency(IAEA) as a safety standard. In many countries, the situation of medical radiographic exposures in each country should be researched before the appropriate guidance level is established. In this study, measurements of entrance surface dose, dose-area product(DAP), computed tomograghic dose index(CTDI) and mean glandular dose(MGD) were carried out in patients who underwent routine x-ray examinations, fluoroscopy, computed tomograghy and mamography in Korea. These measured quantities were compared with the results from the calculation method in previous study. And we suggested diagnostic reference levels in medical imaging in Korea.

  • PDF

Evaluation of Performance and No-reference-based Quality for CT Image with ADMIRE Iterative Reconstruction Parameters: A Pilot Study (ADMIRE 반복적 재구성 파라메터에 따른 CT 영상의 특성 및 무참조 기반 화질 평가: 선행연구)

  • Bo-Min Park;Yoo-Jin Seo;Seong-Hyeon Kang;Jina Shim;Hajin Kim;Sewon Lim;Youngjin Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.175-182
    • /
    • 2024
  • Advanced modeled iterative reconstruction (ADMIRE) represents a repetitive reconstruction method that can adjust strength and kernel, each of which are known to affect computed tomography (CT) image quality. The aim of this study was to quantitatively analyze the noise and spatial resolution of CT images according to ADMIRE control factors. Patient images were obtained by applying ADMIRE strength 2 and 3, and kernel B40 and B59. For quantitative evaluations, the noise level, spatial resolution, and overall image quality were measured using coefficient of variation (COV), edge rise distance (ERD), and natural image quality evaluation (NIQE). The superior values for the average COV, ERD, and NIQE results were obtained for the ADMIRE reconstruction conditions of ADMIRE 2 + B40, ADMIRE 3 + B59, and ADMIRE3 + B59. NIQE, which represents the overall image quality based on no-reference, was about 6.04 when using ADMIRE 3 + B59, showing the best result among the reconstructed image acquisition conditions. The results of this study indicate that the ADMIRE strength and kernel chosen for use in ADMIRE reconstruction have a significant impact on CT image quality. This highlights the importance of adjusting to the control factors in consideration of the clinical environment.

Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System (전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가)

  • Yu, Minsun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.455-464
    • /
    • 2012
  • This study suggested evaluation of approximately exposure to low-dose ionization radiation from medical images using a computed radiography (CR) system in standard X-ray examination and experimental model can compare diagnostic reference level (DRL) will suggest on optimization condition of guard about medical radiation of low dose space. Entrance surface dose (ESD) cross-measuring by standard dosimeter and optically stimulated luminescence dosimeters (OSLDs) in experiment condition about tube voltage and current of X-ray generator. Also, Hounsfield unit (HU) scale measured about each experiment condition in CR system and after character relationship table and graph tabulate about ESD and HU scale, approximately radiation dose about head, neck, thoracic, abdomen, and pelvis draw a measurement. In result measuring head, neck, thoracic, abdomen, and pelvis, average of ESD is 2.10, 2.01, 1.13, 2.97, and 1.95 mGy, respectively. HU scale is $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, and $2,318{\pm}4.64$, respectively, in CR image. At this moment, using characteristic relationship table and graph, ESD measured approximately 2.16, 2.06, 1.19, 3.05, and 2.07 mGy, respectively. Average error of measuring value and ESD measured approximately smaller than 3%, this have credibility cover all the bases radiology area of measurement 5%. In its final analysis, this study suggest new experimental model approximately can assess radiation dose of patient in standard X-ray examination and can apply to CR examination, digital radiography and even film-cassette system.

Evaluation of Radiation Dose and Image Quality according to CT Table Height (CT 테이블 높이에 따른 방사선 선량 및 화질 평가)

  • Lee, Jongwoong;Jung, Hongmoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.453-458
    • /
    • 2017
  • Computed Tomography (CT) provides information on the Diagnostic Reference Level Computed Tomography Dose Index (CTDI) and Dose Length Product (DLP) for accurate diagnosis of patients. However, it does not provide a dose change according to the table height for the diagnostic reference level provided by the CT equipment. The purpose of this study was to evaluate the image and dose according to the table height change using phantom (PMMA: Polymethyl Methacrylate) in order to find the optimal image and the minimum dose during computed tomography examination. When examining using a 32 cm PMMA phantom with the same thickness as the abdomen of an adult, there was little change in dose with table height. However, the noise evaluation of the image caused a high fluctuation of noise depending on the table height. and in the case of the 16 cm PMMA phantom, the change of the noise was small, but the dose change was about 30%. In conclusion, the location of the patient and the center of the detector are important during computed tomography (CT) examinations. In addition, table height setting is considered to be important for examinations with optimized image and minimum dose.

A Study on Models for Technical Security Maturity Level Based on SSE-CMM (SSE-CMM 기반 기술적 보안 성숙도 수준 측정 모델 연구)

  • Kim, Jeom Goo;Noh, Si Choon
    • Convergence Security Journal
    • /
    • v.12 no.4
    • /
    • pp.25-31
    • /
    • 2012
  • The SSE-CMM model is how to verify the level of information protection as a process-centric information security products, systems and services to develop the ability to assess the organization's development. The CMM is a model for software developers the ability to assess the development of the entire organization, improving the model's maturity level measuring. However, this method of security engineering process improvement and the ability to asses s the individual rather than organizational level to evaluate the ability of the processes are stopped. In this research project based on their existing research information from the technical point of view is to define the maturity level of protection. How to diagnose an information security vulnerabilities, technical security system, verification, and implementation of technical security shall consist of diagnostic status. The proposed methodology, the scope of the work place and the current state of information systems at the level of vulnerability, status, information protection are implemented to assess the level of satisfaction and function. It is possible that measures to improve information security evaluation based on established reference model as a basis for improving information security by utilizing leverage.

Myocardial Blood Flow Quantified by Low-Dose Dynamic CT Myocardial Perfusion Imaging Is Associated with Peak Troponin Level and Impaired Left Ventricle Function in Patients with ST-Elevated Myocardial Infarction

  • Jingwei Pan;Mingyuan Yuan;Mengmeng Yu;Yajie Gao;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.709-718
    • /
    • 2019
  • Objective: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI). Materials and Methods: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark. Results: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = -0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = -0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001). Conclusion: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.

A Study of the Family Caregiver's Burden for the Elderly with Chronic disease in a Rural Area (일부 농촌 지역 노인 만성질환자 가족의 부담감에 관한 연구)

  • Jang, In-Sun
    • Journal of Home Health Care Nursing
    • /
    • v.2
    • /
    • pp.19-34
    • /
    • 1995
  • The purpose of this study was to analysis level on family caregiver's burden for the elderly with chronic disease in a rural area and to choose priority care group, thereby facilitating the development of interventions to reduce the caregiver's burden. For this purpose, data were collected by questionaire from June 10 to October 8, 1994. The instruments for data collection were Caregiver Burden Inventory by Novak(1989) and Zarit et al(1982), severity of dementia by Hughes Scales(1982), ADL by Lawton(1971), patients' family caregiving activity by pre-survey and reference review(Lee, 1993 ; Jang, 1990 ; Yoo, 1982). The subjects were 213 family caregiver of elderly with chronic disease in a rural area. The data was analysed by the use of t-test, ANOVA, correlation and multiple regression. The results were as follows ; 1. Total burden was evaluated below average, the mean of family burden was 46.98. By the diagnostic classification, Hypertension was 27.37, DM 32.46, CVA 62.96, Dementia 61.24. 2. Significant variables which were correlated to the family caregiver's burden were the patient's disease diagnosis (F=33.82, p<0.001), severity of dementia(F=30.52, p<0.001), the status of disease management(F=11.53, p<0.001), ADL(F=10.54, p<0.001), PADL(F=7.50, p<0.001), income(F=7.17, p<0.001), caregiver's health status(F=24.53, p<0.001), a view of patient's prognosis (F=22.17, p<0.001), relationship with the patient(F=33.82, p<0.001), the number of hours per day spent on caregiving(F=77.52, p<0.001), level of intimacy of caregiver and patients(F=8.75, p<0.001), level of helping(F=4.90, p<0.01), the frequency of caregiving activity(F=3.80, p<0.01), the number of admission(F=5.54, p<0.01), the length of caregiving(F=4.43, p<0.01), other chronic patient in family(t=2.81, p<0.01), caregiver's job(F=3.11, p<0.01), the duration of illness(F=2.98, p<0.05), caregiver's religion(F=2.93, p<0.05), medical security(F=3.89, p<0.05), caregiving's helper(t=2.42, p<0.05). 3. PADL was the most important predictor to family caregiver burden(R2=0.6611). In addition to this, IADL, caregiver's health status, the length of caregiving. level of intimacy of caregiver and patients, patient's age, the patient's disease diagnosis and patient's job accounted for 76% of family caregiver burden. 4. The criteria of priority care group were as follows ; the mean of family caregiver burden was above 58, above of moderate ADL, the number of hours per day spent on caregiving above of 8 hours, above of moderate dementia. By the diagnostic classification, number of priority care group, Hypertension was 4 (8.0%), DM 4(8.0%), CVA 34(64.1%), Dementia 45(75.0%).

  • PDF

Correlation between attention deficit hyperactivity disorder and sugar consumption, quality of diet, and dietary behavior in school children

  • Kim, Yu-Jeong;Chang, Hye-Ja
    • Nutrition Research and Practice
    • /
    • v.5 no.3
    • /
    • pp.236-245
    • /
    • 2011
  • This study investigated the correlation between consumption of sugar intake by fifth grade students in primary schools and development of Attention Deficit Hyperactivity Disorder (ADHD). A total of 107 students participated, and eight boys and one girl (8.4% of the total) categorized as high risk for ADHD according to diagnostic criteria. There were significant differences in the occupations and drinking habits of the respondents' fathers between the normal group and risk group. In a comparison of students' nutrition intake status with daily nutrition intake standards for Koreans, students consumed twice as much protein as the recommended level, whereas their calcium intake was only 60% of the recommended DRI (dietary reference intake). Regarding intake volume of vitamin C, the normal group posted 143.9% of the recommended DRI, whereas the risk group showed only 65.5% of the recommended DRI. In terms of simple sugar intake from snacks, students in the normal group consumed 58.4 g while the risk group consumed 50.2 g. These levels constituted 12.5% of their total daily volume of sugar intake from snacks, which is higher than the 10% standard recommended by the WHO. In conclusion, children who consumed less sugar from fruit snacks or whose vitamin C intake was less than RI was at increased risks for ADHD (P < 0.05). However, no significant association was observed between total volume of simple sugar intake from snacks and ADHD development.

Set Up and Operation for Medical Radiation Exposure Quality Control System of Health Promotion Center (건강검진센터의 의료방사선 피폭 품질관리 시스템 구축 운영 경험 보고)

  • Kim, Jung-Su;Jung, Hae-Kyoung;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT $357.9mGy{\cdot}cm$ in abdomen and pelvic CT, $572.4mGy{\cdot}cm$ in brain without CT, $55.9mGy{\cdot}cm$ in calcium score/heart CT, screening CT at $54mGy{\cdot}cm$ in chest screening CT(low dose screening CT scan), $284.99mGy{\cdot}cm$ in C-spine CT and $341.85mGy{\cdot}cm$ in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows $274.0mGy{\cdot}cm2$ and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure.