• Title/Summary/Keyword: Reference Grid

Search Result 310, Processing Time 0.025 seconds

A Study on the Plan Photogrammetry for Clothing Design (피복구성학적 인체계측방법에 관한 연구 - 평면사진계측방법을 중심으로 -)

  • 박찬미;서미아
    • The Research Journal of the Costume Culture
    • /
    • v.5 no.1
    • /
    • pp.151-164
    • /
    • 1997
  • This study pursues the problems of plan photogrammetry which is widely used in somatotyping at present, and find out a method which can improve accuracy of measurement on the basis of principles and mechanisms of photography-the basic foundation of the photographic analysis methods. As a result, this study proposes a new method which is based on the reference point method and perspective coordinate system. And the test measurement was operated to compare the measurement accuracy of the proposed method and the method based on reference grid screen method and perpendicular coordinate system which is commonly used at present. The result of this test measurement showed that the proposed method has higher accuracy. Two reasons can be pointed out for the improvement of measuring accuracy. The first reason is that the proposed perspective coordinate system reduces the perspective distortion of photography. And second reason is that measuring points can be closely placed to the scale and coordinate reference plan of measurement by the proposed reference point method which make possible to place measuring object (or person) at the center of scale and coordinate reference plan by utilizing reference points of measurement in the three dimensional space not on screen.

  • PDF

The Reference Wave Generator for Dynamic Voltage Restorers by use of PQR Instantaneous Power Theory (PQR 순시전력이론에 의한 동적전압보상기의 기준파 발생기)

  • 김효성;이상준;설승기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.435-441
    • /
    • 2003
  • Dynamic Voltage Restorers (DVR)s are known as the best effective and economic means to compensate for voltage sags and swells. This paper proposes a novel method to generate reference voltages synchronized with the grid whether the line voltages are distorted by a fault or not. The proposed reference wave generator (RWG) looks for the original wave forms from the corrupted line voltages and synthesizes the expected positive sequence reference waves for DVRs. There is no transient problem on the generated reference waves when the line voltages are distorted by the fault.

Design of Control System for 1kW Grid-connected Permanent Magnet Synchronous Generator (가스 엔진용 1kW급 계통 연계 영구자석형 동기발전기 구동 시스템 설계)

  • Lee, Taeyeong;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.69-70
    • /
    • 2017
  • This paper presents design of control system for permanent magnet synchronous generator(PMSG). The gas engine make rotating mechanical energy from gas fuel energy. The rotor of synchronous generator is connected to axis of engine. And it converts the mechanical energy to the electrical energy. The control system of PMSG helps the electrical energy to flow to grid. the single phase pfc rectifier controls the DC-link voltage by controlling the current of filter inductor. If the DC-link voltage is higher than the voltage reference, the filter current could be controlled to flow to grid. The three phase inverter controls the stator current of generator. The direction of the current is controlled depends on motoring or generating mode. The feasibility of the grid-connected PMSG is verified by the experimental results with 1kW prototype.

  • PDF

Orthogonal Grid Generation Using Linear Grid Generating Equations (선형 격자 형성 방정식을 이용한 직교 격자 형성에 관한 연구)

  • Lee S. W.;Kwon J. H.;Kwon O. J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.05a
    • /
    • pp.99-106
    • /
    • 2000
  • A method of two and three dimensional orthogonal grid generation with control of spacing by using the covariant Laplace equation is Presented. An important feature of the methodology is its ability to control effectively the grid spacing especially near the boundaries still maintaining good orthogonality in whole field. The method is based on the concept of decomposition of the global transformation into consecutive transformation of an approximate conformal mapping and au auxiliary orthogonal mapping to have linear and uncoupled equations. Control of cell spacing is based on the concept of reference arc length, and orthogonal correction is performed in the auxiliary domain. It is concluded that the methodology can successfully generate well controlled orthogonal grids around bodies of 2 and 3 dimensional configurations.

  • PDF

Design of Substation Grounding Grid for Reduction of Touch Voltage (접촉전압 저감을 위한 변전소 접지망 설계)

  • Choi, J.K.;Kee, H.C.;Jung, G.J.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2352-2354
    • /
    • 1999
  • The purpose of substation grounding system is to provide reference potential with power system and protect field workers from electrical shock resulted from unsymetrical power system faults. For this purpose, grounding grid should be designed to maintain max, touch voltage under safety criteria in fault conditions. It is difficult, however, to design a safe grounding grid at very resistive or narrow area. This paper describes an example of substation grounding grid design procedures in such areas with very severe design conditions. By using grounding conductors, which is located close to earth surface, earth surface potential could be controlled effectively, so that maximum touch voltages is to be maintained under safety criteria.

  • PDF

Modulated Finite Control Set - Model Predictive Control for Harmonic Reduction in a Grid-connected Inverter

  • Nguyen, Tien Hai;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.268-269
    • /
    • 2017
  • This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. Distorted grid condition is undesirable due to negative effects such as power losses and heating problem in electrical equipments. To enhance the power quality of distributed generation systems under such a condition, a modulated finite control set - model predictive control (MFCS-MPC) scheme will be proposed, in which the optimal switching signals of inverter are chosen by online basis using the principle of current error minimization. In addition, the moving average filter (MAF) is used to improve the phase-lock loop in order to obtain the harmonic-free reference currents on the stationary frame. The usefulness of the proposed MFCS-MPC method is proved by the comparative simulation results under different operating conditions.

  • PDF

Power Factor Control of Wound Rotor Inductiion Generator for Wind Power Generation (풍력발전을 위한 권선형 유도발전기의 역률제어)

  • 김일환
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.6-9
    • /
    • 2000
  • In wind power generating system connected in power grid the value of stator flux has almost constant because the stator side of wound rotor induction generator is connected to power grid. Using the stator and rotor current it is possible to achieve control of generating power in stator side. This means that we can control the power factor by decoupled rotor current in synchronously rotating reference frame. To verify the theoretical analysis results of computer simulation and experiment are presented to support the discussion.

  • PDF

Optimal Control Design-based Gain Selection of an LCL-filtered Grid-connected Inverter in State-Space under Distorted Grid Environment

  • Tran, Vi-Thuy;Yoon, Seung-Jin;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.344-345
    • /
    • 2018
  • In order to alleviate the negative impacts of harmonically distorted grid condition on grid-connect inverters, an optimal control design-based gain selection scheme of an LCL-filtered grid-connected inverter and its ability to compensate selective harmonics are presented in this paper. By incorporating resonant terms into the control structure in the state-space to provide infinity gain at selected frequencies, the proposed control offers an excellent steady-state response even under distorted grid voltage. The proposed control scheme is achieved by using a state feedback controller for stabilization purpose and by augmenting the resonant terms as well as intergral term into a control structure for reference tracking and harmonic compensation. Furthermore, the optimal linear quadratic control approach is adopted for choosing an optimal feedback gain to ensure an asymptotic stability of the whole system. A discrete-time full state observer is also introduced into the proposed control scheme for the purpose of reducing a total number of sensors used in the inverter system. The simulation results are given to prove the effectiveness and validity of the proposed control scheme.

  • PDF

Research on a Multi-Objective Control Strategy for Current-source PWM Rectifiers under Unbalanced and Harmonic Grid Voltage Conditions

  • Geng, Yi-Wen;Liu, Hai-Wei;Deng, Ren-Xiong;Tian, Fang-Fang;Bai, Hao-Feng;Wang, Kai
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.171-184
    • /
    • 2018
  • Unbalanced and distorted grid voltages cause the grid side current of a current source PWM rectifier to be heavily distorted. They can also cause the DC-link current to fluctuate with a huge amplitude. In order to enhance the performance of a current-source PWM rectifier under unbalanced and harmonic grid voltage conditions, a mathematical model of a current-source PWM rectifier is established and a flexible multi-objective control strategy is proposed to control the DC-link current and grid-current. The fundamental positive/negative sequence, $5^{th}$ and $7^{th}$ order harmonic components of the grid voltage are first separated with the proposed control strategy. The grid current reference are optimized based on three objectives: 1) sinusoidal and symmetrical grid current, 2) sinusoidal grid current and elimination of the DC-current $2^{nd}$ order fluctuations, and 3) elimination of the DC-current $2^{nd}$ and $6^{th}$ order fluctuations. To avoid separation of the grid current components, a multi-frequency proportional-resonant controller is applied to control the fundamental positive/negative sequence, $5^{th}$ and $7^{th}$ order harmonic current. Finally, experimental results verify the effectiveness of proposed control strategy.

Wind Power Grid Integration of an IPMSG using a Diode Rectifier and a Simple MPPT Control for Grid-Side Inverters

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.548-554
    • /
    • 2010
  • In this paper, a 1.5 kW Interior Permanent Magnet Synchronous Generator (IPMSG) with a power conditioner for the grid integration of a variable-speed wind turbine is developed. The power-conditioning system consists of a series-type 12-pulse diode rectifier powered by a phase shifting transformer and then cascaded to a PWM voltage source inverter. The PWM inverter is utilized to supply sinusoidal currents to the utility line by controlling the active and reactive current components in the q-d rotating reference frame. While the q-axis active current of the PWM inverter is regulated to follow an optimized active current reference so as to track the maximum power of the wind turbine. The d-axis reactive current can be adjusted to control the reactive power and voltage. In order to track the maximum power of the wind turbine, the optimal active current reference is determined by using a simple MPPT algorithm which requires only three sensors. Moreover, the phase angle of the utility voltage is detected using a simple electronic circuit consisting of both a zero-crossing voltage detecting circuit and a counter circuit employed with a crystal oscillator. At the generator terminals, a passive filter is designed not only to decrease the harmonic voltages and currents observed at the terminals of the IPMSG but also to improve the generator efficiency. The laboratory results indicate that the losses in the IPMSG can be effectively reduced by setting a passive filter at the generator terminals.