• Title/Summary/Keyword: Reference Equipment

Search Result 440, Processing Time 0.03 seconds

TOA-Based Ranging Method using CRS in LTE Signals (LTE 신호의 CRS를 이용한 TOA 기반 거리 측정 방법)

  • Kang, Taewon;Lee, Halim;Seo, Jiwon
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.437-443
    • /
    • 2019
  • In this paper, a new algorithm for the calculation of the range between an LTE base station (BS) and a user equipment (UE) using time-of-arrival (TOA) measurements of LTE signals is proposed. First, the cell identity (cell ID) of the received signal is acquired using the primary synchronization signal (PSS) and secondary synchronization signal (SSS) to identify the BS transmitted the signal. The proposed algorithm exploits the cell-specific reference signal (CRS), the reference sequence inserted in commercial LTE signals, to estimate the time delay using 2D cross-correlation. The obtained TOA estimations can be used to calculate the range employed from the known BS location. The performance of the proposed algorithm is evaluated with the experiment performed using real LTE signals transmitted from the commercial BS.

Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test (엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석)

  • Yang, In-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.1
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.

Development of Permanent Reference Electrode for Corrosion Monitoring of Underground Metallic Structures (지중 금속구조물 부식감시를 위한 영구매설용 기준전극 개발)

  • Ha, Y.C.;Bae, J.H.;Ha, T.H.;Lee, H.G.;Lee, J.D.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.532-534
    • /
    • 2004
  • The advancement of electronics and telecommunication technologies has forced the risk management system for underground metallic structures to evolve into the remote monitoring and control system. Especially, facilities such as gas pipelines, oil pipelines and water distribution lines might make hazardous effect on human safety without continuous monitoring and control. As a result, pipeline engineers have applied cathodic protection system to prevent the degradation of their facilities by corrosion and carried out a periodic monitoring of the pipe-to-soil (P/S) potentials at numberous test boxes along their pipelines. The latter action on a road in downtowns, however, is so much dangerous that the inspectors should be ready to suffer the threatening of their lives and maintenance. In order to minimize these social costs and hazards, a stand-alone type corrosion monitoring equipment which can be installed in test box, store the P/S data for given Belied and send the data by wired/wireless telecommunications is under development. In order to obtain the exact P/S data, however, a reference electrode should be located as close to the pipeline as possible. Actually, the measured potential by a conventional portable reference electrode contain inevitably an IR drop portion caused by the current flow from the cathodic protection rectifier or the subway railroad. To minimize this error, it is recommended that the reference electrode should be buried within 10 cm from the pipeline. In this paper, we describe the design parameters for fabricating the permanent type reference electrode and the characteristics of the developed reference electrode.

  • PDF

Study on Consumer Awareness for the Development of Personal Protective Equipment for Hog Raisers (양돈작업자의 개인보호구 개발을 위한 소비자 인식조사)

  • Hwang, Young-Mi;Kim, Kyung-Ran;Lee, Kyung-Suk;Chae, Hye-Seon
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.6
    • /
    • pp.522-531
    • /
    • 2013
  • Objectives: A field survey was conducted in a hog-raising industry in order to help develop personal protective equipment for workers which would secure the safety and the health of these workers. The attempt by this study will help enhance safety in the livestock industry and contribute to the advancement of the industry. Method: The study first selected a total of 111 workers from the hog-raising industry as research participants and designed a survey with questions on general characteristics, indoor and outdoor working environments, how the workers would in practice wear or purchase the working clothes, what needs to be improved in these new working clothes, how much the workers would be likely to accept the working clothes and protective equipment, and lastly, conditions of the communicable disease control overgarment. The collected data underwent frequency analysis and cross analysis with SPSS 21.0. Result: The research targets' average age was 50 years. Work efficiency by environmental factor was normal, but all age groups had experience of accidents (79.3%). Major wounded parts were under elbow and under knee. Protective equipment most commonly worn was helmet (83.4%), gloves (98.2%) and boots (99.1%), and satisfaction with them was normal at 3.41. Working clothing most commonly worn was old clothing (31.8%) and everyday wear (17.6%) and satisfaction with it was low. Considering the improvement of working clothing, they required attached pouches, elasticity and deodorization. The acceptability of improved working clothing was high at 69.2%. Conclusion: After problems have been addressed in relevant future research, what has been learned from the concerned study will be referred to as a useful basic reference when the relevant field works to develop high-quality working clothing and protective equipment for workers in the hog-raising industry.

Improving Performance Certification of Aviation Security Equipment (항공보안장비 성능인증기술 고도화 방안 연구)

  • Jung, Jin Hyeong;Kim, Ki-Yeon;Yoon, Yeon Ah;Kim, Na Yeon;Sim, Hyun Su;Lee, Seung Hoon;Ha, Da Som;Seol, Eun-Suk;Han, Soo Jin;Park, Soo-Hong;Yu, Sang Woo;Kim, Yong Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.48 no.1
    • /
    • pp.187-199
    • /
    • 2020
  • Purpose: This study suggests how to upgrade performance certification technology. Current performance certification of aviation security equipment and the requirements thereof were analyzed. Methods: The performance certification of aviation security equipment worldwide and identified issues with the domestic certification system were compared. The government must upgrade certification in terms of technical standards, the assessment methodology used, and the operating system. Results: Three principal conclusions were drawn. First, certification requirements must be based on a review of the technical literature and real-world experience. Second, development priorities must be set by reference to assessment techniques. Third, both research on the certification system and improvements thereof are essential. Conclusion: Certification of aviation security equipment performance requires gradual upgrading.

Improvement of Inter prediction by using Homography Reference Picture (Homography 참조 픽처를 사용한 화면 간 예측 효율 향상 방법)

  • Kim, Tae Hyun;Park, Gwang Hoon
    • Journal of Broadcast Engineering
    • /
    • v.22 no.3
    • /
    • pp.397-400
    • /
    • 2017
  • Recently, a lot of images containing various global movements have been generated by the activation of the photographic equipment such as the drone and the action cam. In this case, when the motion such as rotation, scaling is generated, it is difficult to expect a high coding efficiency in the conventional inter-picture prediction method using the 2D motion vector. In this paper, we propose a video coding method that reflects global motion through homography reference pictures. As a proposed method, there are 1) a method of generating a new reference picture by grasping a global motion relation between a current picture and a reference picture by homography, and 2) a method of utilizing a homography reference picture for inter-picture prediction. The experiment was applied to the HEVC reference software HM 14.0, and the experimental result showed an increase in encoding efficiency of 6.6% based on RA. Especially, the results using the videos with rotational motion have a maximum coding efficiency of 32.6%, which is expected to show high efficiency in video, which is often represented by complex global motion such as drones.

Study on Measurement Accuracy by Auto-Collimation using Theodolite (데오드라이트를 이용한 자동 시준에 의한 측정 정확도에 관한 연구)

  • Lee Byoung-Gi;Kwon Jae-Wook;Yoon Yong-Sik
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1793-1796
    • /
    • 2005
  • The auto-collimation by using theodolite has been accomplished for the straight measurement and the horizontality adjustment. But according to the procedure of auto-collimation or composition of the measurement equipment, an error of the measurement can be occurred. Therefore, this paper accomplished the research for enhancement of measurement accuracy according to measurement procedure of auto-collimation. For that, it has been compared the study of the combination of several precise measurement equipment with using of several theodolite.

  • PDF

The field-test of Power Quality Meter and Power Management System in order to verify the performance (PQM 및 PQMS 성능검증을 위한 실증시험)

  • Choi, Sun-Kyu;Song, Il-Keun;Kwon, Tae-Ho;Han, Jae-Wook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.235-239
    • /
    • 2005
  • This paper gives a field-test method and result of PQM(Power Quality Meter) and PQMS(Power Quality Management System). The field-test was carried out as our own method. So, the test method has several kinds of improvement in this paper because it is first time to try the field-test of the equipment. However, we expect that the test result of PQM & PQMS has been used as a reference data which makes a scheme of evaluating performance of the equipment that has been used or is developed.

  • PDF

Relative Motion Control Methodology Using the Minimum Relative Error Between Two Systems (두 시스템간의 편차 최소화를 적용한 상대적 동작제어 방법)

  • 김성권
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.12
    • /
    • pp.994-1000
    • /
    • 2003
  • A new relative motion control methodology for a following system to an independent leading system is proposed for controlling relative position, velocity, and tension etc. It is based on maintaining minimum relative error between two independent systems. The control command of the following system to a leading system is generated by adding the current command and the output of the relative error compensation. The proposed control method is implemented on the experimental equipment which is a wire winding-unwinding system to control the tension of the line. The results show the unwinding system(follower) following the independent motion of the winding system(leader) to control the constant tension of the line in order to keep the roller dancer in reference position. The relative motion control method proposed in this paper can be applied to high precision equipment for unwinding and winding fine wire, fine fiber, and tape etc.

Development of a Digital Mock-up for Conceptual Design of a Submarine (잠수함 개념 설계를 위한 디지털 목업 개발)

  • Kim, Tae-Hwan;Chun, Sang-Hoo;Sheen, Dong-Mok
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.152-157
    • /
    • 2009
  • In designing and manufacturing a submarine, an expensive real mock up is usually built as a reference because of the spatial constraints of a submarine. This paper presents an integrated and automated design process for a submarine that uses a digital mock up. Various equipment libraries are built for feature based design. Using the developed digital mock up, this paper shows various ways to verify the design, including a space analysis to check for any interference between pieces of equipment and the hull and an ergonomic analysis using lifelike dummies to examine the work space and operability. As a part of the integrated design system, a design automation system was also developed to generate surface point data for the outer hull, pressure hull, casing, and sail. The whole process was applied to the design of a submarine for verification.