• Title/Summary/Keyword: Reference Elimination

Search Result 98, Processing Time 0.022 seconds

A fast full search algorithm for multiple reference image motion estimation (다중 참조 영상 움직임 추정을 위한 고속 전역탐색법)

  • Kang Hyun-Soo;Park Seong-Mo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.1 s.307
    • /
    • pp.1-8
    • /
    • 2006
  • This paper presents a fast full search algorithm for motion estimation applicable to multiple reference images. The proposed method is an extended version of the rate constrained successive elimination algorithm (RSEA) for multiple reference frame applications. We will show that motion estimation for the reference images temporally preceding the first reference image can be less intensive in computation compared with that for the first reference image. for computational reduction, we will drive a new condition to lead the smaller number of candidate blocks for the best matched block. Simulation results explain that our method reduces computation complexity although it has the same quality as RSEA.

Fast Algorithm Based on Successive Elimination Algorithm for Multi-Reference Motion Estimation (다중 참조영상 움직임 추정에 적응을 위한 연속 제거 알고리즘 기반 고속화 알고리즘)

  • Kim Young-Moon;Lee Jae-Eun;Lim Chan;Kang Hyun-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.7
    • /
    • pp.889-897
    • /
    • 2005
  • This paper presents a new fast motion estimation algorithm for multi-reference frames. We first analyze the experimental results of the successive elimination algorithm, which is a fast version of full search algorithm, being applied to Multi-reference frames. Based on the analysis, a new scheme for alleviating its computational burden is introduced. In the proposed method, the motion vector for the immediately previous reference frame is found by applying the successive elimination algorithm, while the motion vector for other reference frames is estimated by extrapolation of the already obtained motion vector. Adaptively restricting the motion search area to the local area centered on the estimated motion vector, the proposed method provides dramatic computational complexity reduction but slight quality degradation. The proposed method is evaluated by experiments for some image sequences.

  • PDF

Development of Portable Cable Fault Detection System with Automatic Fault Distinction and Distance Measurement (자동 고장 판별 및 거리 측정 기능을 갖는 휴대용 케이블 고장 검출 장치 개발)

  • Kim, Jae-Jin;Jeon, Jeong-Chay
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1774-1779
    • /
    • 2016
  • This paper proposes a portable cable fault detection system with automatic fault distinction and distance measurement using time-frequency correlation and reference signal elimination method and automatic fault classification algorithm in order to have more accurate fault determination and location detection than conventional time domain refelectometry (TDR) system despite increased signal attenuation due to the long distance to cable fault location. The performance of the developed system method was validated via an experiment in the test field constructed for the standardized performance test of power cable fault location equipments. The performance evaluation showed that accuracy of the developed system is less than 1.34%. Also, an error of automatic fault type and location by detection of phase and peak value through elimination of the reference signal and normalization of correlation coefficient and automatic fault classification algorithm not occurred.

Detection and Location of Cable Fault Using Improved SSTDR (개선된 SSTDR을 이용한 케이블 고장 검출과 위치 계산)

  • Jeon, Jeong-Chay;Kim, Jae-Jin;Choi, Myeong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1583-1589
    • /
    • 2016
  • This paper proposes an improved spread spectrum time domain reflectometry (ISSTDR) using time-frequency correlation and reference signal elimination method in order to have more accurate fault determination and location detection than conventional (SSTDR) despite increased signal attenuation due to the long distance to cable fault location. The proposed method has a two-step process: the first step is to detect a peak location of the reference signal using time-frequency correlation analysis, and the second step is to detect a peak location of the correlation coefficient of the reflected signal by removing the reference signal. The proposed method was validated through comparison with existing SSTDR methods in open-and short-circuit fault detection experiments of low voltage power cables. The experimental results showed that the proposed method can detect correlation coefficients at fault locations accurately despite reflected signal attenuation so that cable faults can be detected more accurately and clearly in comparison to existing methods.

A study on the model follwing adaptive control system of industrial robtoic manipulatior for factory automation

  • Han, Sung-Hyun;Lee, Man-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.993-998
    • /
    • 1988
  • Adaptive control system has evolved as an attempt to avoid degradation of the dynamic performance of a control system when environmental variations occurs. While the feedback control system is oriented toward the elimination of the effect of state perturbations, the adaptive control system is oriented toward the elimination of the effect of structural perturbation, upon the performances of the control system. The model reference adaptive controller is utilized in velocity loop controller for positioning and tracking is designed based on the linear decoupled dynamics.

  • PDF

Design of the analog phase shifter for the ghost signal elimination (고스트 신호 제거기용 애널러그 위상변위기 설계)

  • 주성호;김동현;이상설
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.825-828
    • /
    • 1999
  • In this paper, we design the analog phase shifter for the elimination of the ghost signal. Compensation of the delay between the reference signal and the relatively delayed signal is possible. This phase shifter uses the vector summing method. We use for the attenuator in our system FETs. The phase shifter is operated at the 200MHz and composed by lumped elements. The proposed analog phase shifter is simulated by the HP ADS software.

  • PDF

Comparison of Frequency and Stay Time between Normal and Abnormal Elimination Behavior of Cats Using a Litter Box with Automatic Sensor

  • Ji-Woo Shin;Sun-Woo Han;Soon-Hak Kweon;Myungseok Kang;Jong-Hyuk Kim;Chung-Gwang Choi;Joon-Seok Chae
    • Journal of Veterinary Clinics
    • /
    • v.41 no.2
    • /
    • pp.71-78
    • /
    • 2024
  • Changes in elimination behavior, including urination and defecation, are common clinical signs of numerous disorders in cats. Therefore, this study attempted to automatically measure the elimination behavior of cats using the litter box and develop an early warning system for the guardian in case of abnormalities. To construct an early warning system for abnormal changes through cat elimination behavior, it consisted of a litter box, an automatic sensor for data collection and data wifi transmission, a server for data analysis, and a mobile phone app for result transmission and early warning. To establish the reference interval (RI), the elimination behavior was monitored for more than 2 weeks using a motion sensor within a litter box in 37 healthy cats and 19 diseased cats. The data were expressed as daily total visits, daily total stay duration, average stay duration per elimination, weekly total visits, and weekly total stay duration. Healthy cats showed median daily total visits of 3 times/day (RI 1.0-7.0) and daily total stay duration of 192 s/day (RI 8.0-452.0). For weekly data, the median total visits were 20 times/week (RI 3.0-35.25) and the median total stay duration was 1,147 s/week (RI 80.0-2,249.5). The average stay duration per elimination was 59 s/elimination (RI 4.67-132.0). Diseased cats showed more frequent elimination behavior than healthy cats (p < 0.001). Otherwise, for each elimination, diseased cats had shorter stay durations than healthy cats (p < 0.001). This study established the RIs of elimination behavior parameters (frequency and duration) in healthy cats. The present study might help guardians and veterinarians detect changes in elimination behaviors in diseased cats at an early stage.

Improvement in rise time and robustness of AC servomotor (AC servo motor 제어시 rise time 과 강인성 개선)

  • 정광조;임선종
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.446-450
    • /
    • 1991
  • PID controller is popular but have defect inversing following reference input and noise elimination. Therefor, this paper focus on reducing rise time and robustness against noise. The result that is simulated with feedforward method and sliding mode show that rise time decrease and robustness increase.

  • PDF

A Study of the Current Reference Signal Generation Circuit for Single-Phase Harmonic Elimination Systems (단상 전원 고조파 제거 시스템을 위한 기준전류 생성회로에 대한 연구)

  • Jung Done-youl;Park Chong-yeon;Kim Sang-hun;Choi Won-ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.7
    • /
    • pp.335-342
    • /
    • 2005
  • This paper presents a circuit to generate the current reference signal for single-phase harmonic elemination systems. Some of conventional methods for the current reference signal generation based on neural network algorithms. It requires complex circuitry to implement. the simplest method is to use analog filters. but it is difficult to obtain good current reference signals. So, we propose the harmonic detection circuit using GIC(Generalized Impedance Converter) for the purpose of low cost ,simple circuitry and high performance, Simulation and experimental results verify that the proposed circuit has better harmonic detection performance than conventional circuit.