• Title/Summary/Keyword: Redundant Sensors

Search Result 48, Processing Time 0.035 seconds

A Calibration Technique for a Redundant IMU Containing Low-Grade Inertial Sensors

  • Cho, Seong-Yun;Park, Chan-Gook
    • ETRI Journal
    • /
    • v.27 no.4
    • /
    • pp.418-426
    • /
    • 2005
  • A calibration technique for a redundant inertial measurement unit (IMU) containing low-grade inertial sensors is proposed. In order to calibrate a redundant IMU that can detect and isolate faulty sensors, the fundamental coordinate frames in the IMU are defined and the IMU error is modeled based on the frames. Equations to estimate the error coefficients of the redundant IMU are formulated, and a test sequence using a 2-axis turntable is also presented. Finally, a redundant IMU with cone configuration is implemented using low-grade inertial sensors, and the performance of the proposed technique is verified experimentally.

  • PDF

Optimal Configuration of Redundant Inertial Sensors with Uncertainty (불확실성을 고려한 중복 관성센서의 최적 배치)

  • Shim Duk-Sun;Yang Cheol-Kwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.2
    • /
    • pp.81-86
    • /
    • 2005
  • In this paper we consider an optimal configuration problem for redundant inertial sensors which have uncertainty such as misalignment, scale factor error. The optimal configuration problem is treated from the viewpoint of navigation accuracy. We propose a necessary and sufficient condition for the optimal configuration of redundant sensors with no uncertainty, and a sufficient condition for the optimal configuration of redundant sensors with uncertainty. Finally we propose a condition for the optimal configuration based both navigation performance and FDI(fault detection and isolation).

Simultaneous Fault Isolation of Redundant Inertial Sensors based on the Reduced-Order Parity Vectors

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2188-2191
    • /
    • 2005
  • We consider a fault detection and isolation problem for inertial navigation systems which use redundant inertial sensors. We propose a FDI method using average of multiple parity vectors which reduce false alarm and wrong isolation, and improve correct isolation. We suggest the number of redundant sensors required to isolate simultaneous faults. The performance of the proposed FDI algorithm is analyzed by Monte-Carlo simulation.

  • PDF

Accommodation Rule Based on Navigation Accuracy for Double Faults in Redundant Inertial Sensor Systems

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.3
    • /
    • pp.329-336
    • /
    • 2007
  • This paper considers a fault accommodation problem for inertial navigation systems (INS) that have redundant inertial sensors such as gyroscopes and accelerometers. It is wellknown that the more sensors are used, the smaller the navigation error of INS is, which means that the error covariance of the position estimate becomes less. Thus, when it is decided that double faults occur in the inertial sensors due to fault detection and isolation (FDI), it is necessary to decide whether the faulty sensors should be excluded or not. A new accommodation rule for double faults is proposed based on the error covariance of triad-solution of redundant inertial sensors, which is related to the navigation accuracy of INS. The proposed accommodation rule provides decision rules to determine which sensors should be excluded among faulty sensors. Monte Carlo simulation is performed for dodecahedron configuration, in which case the proposed accommodation rule can be drawn in the decision space of the two-dimensional Cartesian coordinate system.

Optimal IMU Configurations for a SDINS

  • Kim, Kwang-Hoon;Lee, Jang-Gyu;Shim, Duk-Sun;Park, Chan-Gook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.116.5-116
    • /
    • 2001
  • When inertial navigation system(INS) employ more sensors that mutually orthogonal sets to three, the redundant sensor system can have improved reliability and accuracy. For the redundant system the placement of redundant sensors is related to the system performance and also the number and proper orientation of sensors are important. We consider INS sensor configurations using two IMUs comprised mutually orthogonal sets of three. We suggest several configurations using two IMUs and analyze the system performance and the FDI(fault detection and isolation) properties from suggested configurations.

  • PDF

Fault Detection and Isolation using Singular Value Decomposition for Redundant Sensors System (특이치 분해를 이용한 중복 센서의 EDI 기법과 성능 분석)

  • 심덕선;양철관
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.4
    • /
    • pp.364-370
    • /
    • 2004
  • In this paper, we propose a FDI method, which comes from singular value decomposition of measurement matrix fur redundant sensors. We analyze the performance of the proposed FDI method by comparing with the GLT method in two ways such as FDI performance and GN&C performance. Also, we propose a GN&C performance index by combining FDI and GN&C performance.

Calibration of a Redundant IMU with Low-grade Inertial Sensors (저급 관성센서로 구성된 중첩 IMU의 오차 보정)

  • Cho, Seong-Yun;Park, Chan-Gook;Lee, Dal-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.10
    • /
    • pp.53-59
    • /
    • 2004
  • A calibration technique for a redundant IMU with low-grade inertial sensors is proposed. In order to calibrate the redundant IMU that can detect and isolate a faulty sensor, the fundamental coordinate frames in the IMU are defined and the IMU error is modeled based on the frames. Equations to estimate the error coefficients of the redundant IMU are formulated, and a test sequence using the 2-axis rate table is also presented. Finally, a redundant IMU with cone configuration is implemented using the low-grade inertial sensors and the performance of the proposed technique is verified by some experiments.

Modified parity space averaging approaches for online cross-calibration of redundant sensors in nuclear reactors

  • Kassim, Moath;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.50 no.4
    • /
    • pp.589-598
    • /
    • 2018
  • To maintain safety and reliability of reactors, redundant sensors are usually used to measure critical variables and estimate their averaged time-dependency. Nonhealthy sensors can badly influence the estimation result of the process variable. Since online condition monitoring was introduced, the online cross-calibration method has been widely used to detect any anomaly of sensor readings among the redundant group. The cross-calibration method has four main averaging techniques: simple averaging, band averaging, weighted averaging, and parity space averaging (PSA). PSA is used to weigh redundant signals based on their error bounds and their band consistency. Using the consistency weighting factor (C), PSA assigns more weight to consistent signals that have shared bands, based on how many bands they share, and gives inconsistent signals of very low weight. In this article, three approaches are introduced for improving the PSA technique: the first is to add another consistency factor, so called trend consistency (TC), to include a consideration of the preserving of any characteristic edge that reflects the behavior of equipment/component measured by the process parameter; the second approach proposes replacing the error bound/accuracy based weighting factor ($W^a$) with a weighting factor based on the Euclidean distance ($W^d$), and the third approach proposes applying $W^d$, TC, and C, all together. Cold neutron source data sets of four redundant hydrogen pressure transmitters from a research reactor were used to perform the validation and verification. Results showed that the second and third modified approaches lead to reasonable improvement of the PSA technique. All approaches implemented in this study were similar in that they have the capability to (1) identify and isolate a drifted sensor that should undergo calibration, (2) identify a faulty sensor/s due to long and continuous missing data range, and (3) identify a healthy sensor.

Fault Detection and Isolation using navigation performance-based Threshold for Redundant Inertial Sensors

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2576-2581
    • /
    • 2003
  • We consider fault detection and isolation (FDI) problem for inertial navigation systems (INS) which use redundant inertial sensors and propose an FDI method using average of multiple parity vectors which reduce false alarm and wrong isolation, and improve correct isolation. We suggest optimal isolation threshold based on navigation performance, and suggest optimal sample number to obtain short detection time and to enhance detectability of faults little larger than threshold.

  • PDF

Redundant Sensor Systems for the Measurement under Uncertain Conditions (불확실한 조건에서의 계측을 위한 잉여센서시스템)

  • 도용태
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2000.11a
    • /
    • pp.436-439
    • /
    • 2000
  • To interact with surroundings robots and other automated machines employ sensors. However, the sensors measurements are uncertain in some amount and this may limit the potential applications of machines. Varying surrounding conditions and noises of sensor signals are major sources of the uncertainty. In this paper the uncertainty is tried to be reduced by using redundant sensor systems, where the redundancy is accomplished by varying the parameters of logically defined sensors. The target value redundantly measured is estimated adaptively. An experiment was done for measuring the stereoscopic 3D position measurement in an inconsistent light condition.

  • PDF