• Title/Summary/Keyword: Reduction of Wall Thickness

Search Result 134, Processing Time 0.028 seconds

The Dose Distribution of Arc therapy for High Energy Electron (고에너지 전자선 진자조사에 의한 선량분포)

  • Chu, S.S.;Kim, G.E.;Suh, C.O.;Park, C.Y.
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.29-36
    • /
    • 1983
  • The treatment of tumors along curved surfaces with stationary electron beams using cone collimation may lead to non-uniform dose distributions due to a varying air gap between the cone surface and patient. For large tumors, more than one port may have to be used in irradiation of the chest wall, often leading to regions of high or low dose at the junction of the adjacent ports. Electron-beam arc therapy may elimination many of these fixed port problems. When treating breast tumors with electrons, the energy of the internal mammary port is usually higher than that of the chest wall port. Bolus is used to increase the skin dose or limit the range of the electrons. We invertiaged the effect of various arc beam parameters in the isodose distributions, and combined into a single arc port for adjacent fixed ports of different electron beam eneries. The higher fixed port energy would be used as the arc beam energy while the beam penetration in the lower energy region would be controlled by a proper thickness of bolus. We obtained the results of following: 1. It is more uniform dose distribution of electron to use rotation than stationary irradiation. 2. Increasing isocenter depth on arc irradiation, increased depth of maximum dose, reduction in surface dose and an increasing penetration of the linear portion of the curve. 3. The deeper penetration of the depth dose curve and higher X-ray background for the smaller field sized. 4. If the isocenter depth increase, the field effect is small. 5. The decreasing arc beam penetration with decreasing isocenter depth and the isocenter depth effect appears at a greater depth as the energy increases. 6. The addition of bolus produces a shift in the penetration that is the same for all depths leaving the shape of the curves unchanged. 7. Lead strips 5 mm thick were placed at both ends of the arc to produce a rapid dose drop-off.

  • PDF

Response of Ovaries and Cyst According to Treatment with Dinoprost or Fenprostalene in Dairy Cows with Ovarian Luteal Cyst (황체낭종우에서 Dinoprost 또는 Fenprostalene 치료에 대한 난소 및 낭종의 반응)

  • 강현구;김일화;백인석;손창호;이청산
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.154-160
    • /
    • 2004
  • This study was carried out to monitor the response of ovaries and cyst according to treatment with dinoprost or fenprostalene in dairy cows with ovarian luteal cyst. Twenty cows were diagnosed as luteal cysts by rectal palpation, ultrasonography and progesterone analysis. The cystic cows were treated with dinoprost or fenprostalene. All the animals were re-examined by ultrasonography and blood was collected for the measurement of plasma progesterone concentration at day 0 (the day of treatment), 3, 13 and 24, respectively. Mean plasma progesterone concentrations on day -11 and day -1 before treatment were 2.1$\pm$0.2 ng/ml and 2.8$\pm$0.3 ng/ml, respectively. On day 3 and day 13 were 0.3$\pm$0.1 ng/ml and 4.3$\pm$0.2 ng/ml, respectively. Mean cystic wall thickness on day -11 and day -1 were 3.2$\pm$0.2 mm and 3.9$\pm$0.2 mm, respectively. And on day 3 was 2.4$\pm$0.3 mm. The responses of luteal cyst after treatment noted during ultrasonography included dramatical degeneration of the luteal tissue of cystic wall on day 3 (all cows), slowly reduction of cyst size (cyst resolution) until last examination (8 cows), complete disappearance on day 13 (7 cows) and no changes of cyst size (5 cows). A group of 10 cows with luteal cysts injected fenprostalene compared with another 10 cows treated dinoprost showed a slightly higher pregnancy rate on first service after initial treatment (50.0 vs 30.0%). But treatment effects of dinoprost or fenprostalene did not significantly different results for each groups. This study suggested that the response of the cyst according to treatment revealed various types. Therefore, veterinarians should have attention on monitoring of the response of cystic ovaries after treatment, specially on no change of cyst size after treatment.

The Effect of Nozzle Collar on Single Phase and Boiling Heat Transfer by Planar Impinging Jet (평면 충돌제트에서 노즐 깃이 단상 및 비등 열전달에 미치는 영향)

  • Shin Chang Hwan;Yim Seong Hwan;Wu Seong Je;Cho Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.878-885
    • /
    • 2005
  • The water jet impingement cooling is one of the techniques to remove the heat from high heat flux equipments. Local heat transfer of the confined water impinging jet and the effect of nozzle collar to enhance the heat transfer are investigated in the fee surface jet and submerged jet. Boiling is initiated from the farthest downstream and increase of the wall temperature is reduced with developing boiling, forming the flat temperature distributions. The reduction in the nozzle-to-surface distance fur H/W$\le$1 causes significant increases and distribution changes of heat transfer. Developed boiling reduces the differences of heat transfer for various conditions. The nozzle collar is employed at the nozzle exit. The distances from heated surface to nozzle collar, Hc are 0.25W, 0.5W and 1.0W. The liquid film thickness is reduced and the velocity of wall jet increases as decreased spacing of collar to heated surface. Heat transfer is enhanced fur region from the stagnation to x/W$\~$8 in the free surface jet and to x/W$\~$5 in the submerged jet. For nucleate boiling region of further downstream, the heat transfer by the nozzle collar is decreased in submerged jet comparing with higher velocity condition. It is because the increased velocity by collar is de-accelerated downstream.

The Effect of Nozzle Collar on Single Phase and Boiling Heat Transfer by Planar Impinging Jet (평면 충돌제트에서 노즐 깃이 단상 및 비등 열전달에 미치는 영향)

  • Shin, Chang-Hwan;Yim, Seong-Hwan;Wu, Seong-Je;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1452-1457
    • /
    • 2004
  • The water jet impingement cooling is one of the techniques to remove heat from high heat flux equipments. We investigate the local heat transfer of the confined water impinging jet and the effect of nozzle collar to enhance the heat transfer in the free surface jet and submerged jet. Boiling is initiated from the furthest downstream and the wall temperature increase is reduced with developing boiling, forming the flat temperature distributions. The reduction in the nozzle-to-surface distance for $H/W{\leq}1$ causes the significant increases and distribution changes in heat transfer. Developed boiling reduces the differences in heat transfer for various conditions. The nozzle collar is employed at the nozzle exit. The distances from heated surface to guide plate, $H_c$ are 0.25W, 0.5W and 1.0W. The liquid film thickness is reduced and the velocity of wall jet increase as decreased spacing of collar to heated surface. Heat transfer is enhanced for region from the stagnation to $x/W{\sim}8$ in the free surface jet and to $x/W{\sim}5$ in the submerged jet. For nucleate boiling region of further downstream, the heat transfer by the nozzle collar is decreased in submerged jet compare with higher velocity condition. It is because the increased velocity by collar is de-accelerated at downstream.

  • PDF

Burst strength behaviour of an aging subsea gas pipeline elbow in different external and internal corrosion-damaged positions

  • Lee, Geon Ho;Pouraria, Hassan;Seo, Jung Kwan;Paik, Jeom Kee
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.3
    • /
    • pp.435-451
    • /
    • 2015
  • Evaluation of the performance of aging structures is essential in the oil and gas industry, where the inaccurate prediction of structural performance can have significantly hazardous consequences. The effects of structure failure due to the significant reduction in wall thickness, which determines the burst strength, make it very complicated for pipeline operators to maintain pipeline serviceability. In other words, the serviceability of gas pipelines and elbows needs to be predicted and assessed to ensure that the burst or collapse strength capacities of the structures remain less than the maximum allowable operation pressure. In this study, several positions of the corrosion in a subsea elbow made of API X42 steel were evaluated using both design formulas and numerical analysis. The most hazardous corrosion position of the aging elbow was then determined to assess its serviceability. The results of this study are applicable to the operational and elbow serviceability needs of subsea pipelines and can help predict more accurate replacement or repair times.

Fabrication and Evaluation of Carbon Nanotube Reinforced Al Matrix Composite by a Powder-in-sheath Rolling Method (분말시스압연법에 의한 CNT 강화 Al기 복합재료의 제조 및 평가)

  • Lee, Seong-Hee;Hong, Dongmin
    • Journal of Powder Materials
    • /
    • v.21 no.1
    • /
    • pp.50-54
    • /
    • 2014
  • A powder-in-sheath rolling method was applied to a fabrication of a carbon nano tube (CNT) reinforced aluminum composite. A STS304 tube with an outer diameter of 34 mm and a wall thickness of 2 mm was used as a sheath material. A mixture of pure aluminum powders and CNTs with the volume contents of 1, 3, 5 vol was filled in the tube by tap filling and then processed to 73.5% height reduction by a rolling mill. The relative density of the CNT/Al composite fabricated by the powder-in-sheath rolling decreased slightly with increasing of CNTs content, but exhibited high value more than 98. The grain size of the aluminum matrix was largely decreased with addition of CNTs; it decreased from $24{\mu}m$ to $0.9{\mu}m$ by the addition of only 1 volCNT. The average hardness of the composites increased by approximately 3 times with the addition of CNTs, comparing to that of unreinforced pure aluminum. It is concluded that the powder-in-sheath rolling method is an effective process for fabrication of CNT reinforced Al matrix composites.

Microstructure and Mechanical Properties of CNT/Al Composite Fabricated by a Powder-in-Sheath Rolling Method utilizing Copper Tube as a Sheath (구리튜브를 피복재로 이용한 분말시스압연법에 의해 제조된 CNT/Al 복합재료의 미세조직 및 기계적 특성)

  • Lee, Seong-Hee
    • Journal of Powder Materials
    • /
    • v.21 no.5
    • /
    • pp.343-348
    • /
    • 2014
  • A powder-in-sheath rolling (PSR) process utilizing a copper alloy tube was applied to a fabrication of a multi-walled carbon nanotube (CNT) reinforced aluminum matrix composite. A copper tube with an outer diameter of 30 mm and a wall thickness of 2 mm was used as a sheath material. A mixture of pure aluminum powders and CNTs with the volume contents of 1, 3, 5 vol% was filled in the tube by tap filling and then processed to 93.3% height reduction by a rolling mill. The relative density of the CNT/Al composite fabricated by the PSR decreased slightly with increasing of CNTs content, but showed high value more than 98%. The average hardness of the 5%CNT/Al composite increased more than 3 times, compared to that of unreinforced pure Al powder compaction. The hardness of the CNT/Al composites was some higher than that of the composites fabricated by PSR using SUS304 tube. Therefore, it is concluded that the type of tube affects largely on the mechanical properties of the CNT/Al composites in the PSR process.

축류회전차 익말단 틈새유동에 대한 수치해석

  • No, Su-Hyeok;Jo, Gang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.336-345
    • /
    • 1998
  • The substantial loss behind axial flow rotor was generated by wake, various vortices in the hub region and the leakage vortex in the tip region. Particularly, the leakage vortex formed near blade tip was one of the main causes of the reduction of performance, the generation of noise and the aerodynamic vibration in rotor downstream. In this study, the three-dimensional flowfields in an axial flow rotor for various tip clearances were calculated, and the numerical results were compared with the experimental ones. The numerical technique was based on SIMPLE algorithm using standard k-.epsilon. model (WFM). Through calculations, the effects of the tip clearance on the overall performance of rotor and the loss distributions, and the increase in the displacement, momentum, and blade-force-deficit thickness of the casing wall boundary layer were investigated. The mass-averaged flow variables behind rotor agreed well with the experimental results. The presence of the tip leakage vortex behind rotor was described well. Although the loci of leakage vortex by calculation showed some differences compared with the experimental results, its behavior for various tip clearances was clarified by examining the loci of vortex center.

Microstructure and Mechanical Properties of 3vol%CNT Reinforced Cu Matrix Composite Fabricated by a Powder in Sheath Rolling Method (분말시스압연법에 의해 제조된 3vol%CNT 강화 Cu기 복합재료의 미세조직 및 기계적 성질)

  • Lee, Seong-Hee
    • Korean Journal of Materials Research
    • /
    • v.30 no.3
    • /
    • pp.149-154
    • /
    • 2020
  • A powder-in-sheath rolling method is applied to the fabrication of a carbon nano tube (CNT) reinforced copper composite. A copper tube with outer diameter of 30 mm and wall thickness of 2 mm is used as sheath material. A mixture of pure copper powder and CNTs with a volume content of 3 % is filled in a tube by tap filling and then processed to an 93.3 % reduction using multi-pass rolling after heating for 0.5 h at 400 ℃. The specimen is then sintered for 1h at 500 ℃. The relative density of the 3 vol%CNT/Cu composite fabricated using powder in sheath rolling is 98 %, while that of the Cu powder compact is 99 %. The microstructure is somewhat heterogeneous in width direction in the composite, but is relatively homogeneous in the Cu powder compact. The hardness distribution is also ununiform in the width direction for the composite. The average hardness of the composites is higher by 8Hv than that of Cu powder compact. The tensile strength of the composite is 280 MPa, which is 20 MPa higher than that of the Cu powder compact. It is concluded that the powder in sheath rolling method is an effective process for fabrication of sound CNT reinforced Cu matrix composites.

Process Development of Constant Curvature Extrusion for Aluminum Alloy (알루미늄 합금의 일정 곡률 압출공정 개발)

  • Joe, Y.J.;Lee, S.K.;Oh, K.H.;Park, S.W.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.16 no.7
    • /
    • pp.555-560
    • /
    • 2007
  • This paper shows some achievements at bending of extruded aluminum profiles during the extrusion process. The conventional process for the production of bent profiles involves a successive extrusion, stretching, and bending of the profiles. Conventional bending methods can not meet demands far precision and cost-effective production in some cases, due to cross sectional deformation, irregular decrease of tube wall thickness and a complication of the process design. An estimation of spring-back required for precision of the bending radius can not always be achieved by the over bending of the profile. Since the profile is hot during the bending process, the spring-back phenomenon can be avoided. This means that an additional bending process is not necessary. Consequently, flexible bending can be achieved with cost reduction and quality improvement. Experimental tests were completed to study the relationship between curvature radius of profile and position of guide on the extrusion for vehicle bumper. A7108 is applied as a billet material in order to increase strength. The overall correlation between the experimental and numerical results is good. It is therefore concluded that the present method provides an efficient means for the constant curvature extrusion process.