• Title/Summary/Keyword: Reduction device

Search Result 1,286, Processing Time 0.026 seconds

The input device system with hand motion using hand tracking technique of CamShift algorithm (CamShift 알고리즘의 Hand Tracking 기법을 응용한 Hand Motion 입력 장치 시스템)

  • Jeon, Yu-Na;Kim, Soo-Ji;Lee, Chang-Hoon;Kim, Hyeong-Ryul;Lee, Sung-Koo
    • Journal of Digital Contents Society
    • /
    • v.16 no.1
    • /
    • pp.157-164
    • /
    • 2015
  • The existing input device is limited to keyboard and mouse. However, recently new type of input device has been developed in response to requests from users. To reflect this trend we propose the new type of input device that gives instruction as analyzing the hand motion of image without special device. After binarizing the skin color area using Cam-Shift method and tracking, it recognizes the hand motion by inputting the finger areas and the angles from the palm center point, which are separated through labeling, into four cardinal directions and counting them. In cases when specific background was not set and without gloves, the recognition rate remained approximately at 75 percent. However, when specific background was set and the person wore red gloves, the recognition rate increased to 90.2 percent due to reduction in noise.

Effect of audio distraction with thermomechanical stimulation on pain perception for inferior alveolar nerve block in children: a randomized clinical trial

  • Devendra Nagpal;Dharanshi Viral Amlani;Pooja Rathi;Kavita Hotwani;Prabhat Singh;Gagandeep Lamba
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.6
    • /
    • pp.327-335
    • /
    • 2023
  • Background: Pain control is a crucial aspect of pediatric dentistry for patient management. Thermo-mechanical devices (BuzzyTM Pain Care Labs, USA) work on the concept of vibration and cooling and have shown promising results in pain control during local anesthesia in pediatric dentistry. On the other hand, audio distraction has also been used for pain management. The amount of pain endured is determined by the patient's perception and attentiveness. Thus, if audio function is added to the thermomechanical device it might increase its efficiency. Hence, the present study aimed to compare pain on injection using a thermo-mechanical device with and without audio during inferior alveolar nerve block (IANB) injection in children aged 5-10 years old. Methods: Twenty-eight children aged between 5 and 10 indicated for IANB were included in this randomized study. Children who were undergoing the dental procedure were divided into 2 groups, with 14 children in each group. The study group was the thermo-mechanical device with audio distraction; the control group was the thermo-mechanical device without audio distraction. IANB was administered. Subjective pain evaluation was performed using the Wong-Baker Faces Pain Rating Scale (WBFPR) and objective pain evaluation was done using the Faces, Leg, Activity, Consolability, Cry (FLACC) scale. Results: The outcome depicted a significant reduction in pain on injection for both objective and subjective evaluations in the thermo-mechanical device with an audio distraction group. Conclusions: Less pain on injection was observed, when a thermo-mechanical device was used with audio distraction for IANB procedures.

Improvement in Catalytic NOx Reduction by Using Dielectric Barrier Discharge (유전체장벽방전을 이용한 촉매공정의 질소산화물 저감성능 향상)

  • Mok, Young Sun;Nam, Chang-Mo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • The ozone produced by a dielectric barrier discharge device was injected into the exhaust gas to oxidize a part of NO to $NO_2$, and then the exhaust gas containing the mixture of NO and $NO_2$ was further treated in a catalytic reactor where both NO and $NO_2$ were reduced to $N_2$ in the presence of ammonia as the reducing agent. The $NO_2$ content in the mixture of NO and $NO_2$ was changed by the amount of ozone added to the exhaust gas. The experiments were primarily concerned with the effect of reaction temperature on the catalytic $NO_x$ reduction at various $NO_2$ contents. The increase in the $NO_2$ content by the ozone injection remarkably improved the performance of the catalytic $NO_x$ reduction, especially at low temperatures.

  • PDF

A Study on Electric Potential Change by Pulse Voltage Polarity in Liquid (펄스전압의 극성에 따른 액중 전위변화에 관한 연구)

  • Kim Jin-Gyu;Kim Hyung-Pyo;Park Young-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.79-84
    • /
    • 2005
  • This paper proposes the new type of an ion exchange water generator system. The system has an +/- ion exchange membrane located in center and a diagonal-interdigit type electrode applied to a pulsed power. This system is studied in the liquid for the oxidation/reduction potential and the dissolved oxygen concentration by the polarity effects. Consequently, as a diagonal-interdigit type electrode is installed in each side of device, the oxidation/reduction potential and dissolved oxygen concentration by polarity changes and electrical resistivity differences be observed. An ion concentration in the ion exchange water generator system is increased by dissolved oxygen generated from oxidation/reduction potential changes.

An Experimental Investigation on Reduction of List Angle of a Semi-submersible Platform in Head Sea

  • Kim, Nam Woo;Nam, Bo Woo;Choi, Young Myung;Hong, Sa Young
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.1 no.3
    • /
    • pp.168-175
    • /
    • 2015
  • This study consists of an experimental investigation of the reduction of the second-order roll motion of a semi-submersible platform in head sea conditions by adding hull damping. The second-order heave drift force and roll drift moment are known to be the main triggers that induce the list angle (Hong et al., 2010). Hong et al. (2013) used numerical calculations to show the possibility of reducing the list angle by changing the pontoon shape and adding a damping device on the hull. One of their findings was that the reduction in the list angle due to the increase in pontoon surface damping was significant. A series of model tests were carried out with a 1:50 scaled model of semi-submersible at the KRISO wave basin. The experiments indicated that adding damping on the hull surface effectively suppressed the list angle.

Numerical Analysis Study on Damping Performance of Cable Damper (케이블댐퍼 감쇠성능의 수치해석적 연구)

  • Yhim, Sung-Soon
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.97-104
    • /
    • 2015
  • Compared with a strong axial rigidity due to large intial tension, cable has a weak laterally flexural rigidity. A variety of dynamic loads such as traffic loads and wind loads etc. cause the cables to vibrate significantly and affect the mechanical properties and the performance of cables. Therefore, vibration reduction design is an urgent task to control the vibration of cable-supported bridges. Because a various kind of dampers have shown to reduce the amplitude and duration time of vibration of cable from measured date in field test, damper can be considered that it is effective device significantly to reduce the amplitude and duration time in vibration of cable. Vibration characteristics of cable can change according to manufacturing method and type of established form, and damper has been designed according to distribution of natural frequencies and vibration modes. In this study, numerical analysis is used to show the reduction effects of vibrations and present the design of damper for vibration reduction of cable.

Development and efficiency of filter device for the emission reduction from the diesel engine in fishing boat (어선용 디젤엔진의 배출가스 저감 필터 개발과 저감 효율)

  • Lee, Kyounghoon;Kim, Sang-Keun;Kim, Seonghun;Yang, Yong-Su;Park, Seong-Wook
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.1
    • /
    • pp.50-57
    • /
    • 2014
  • The performance of five kind adsorbents, which can reduce nitrogen oxide (NOx) from the diesel engine occupying 85% of the fishing boat, was carried out and the emission reduction filter was manufactured and evaluated in the adsorption efficiency of the emission gas for 240 KW diesel portable generator. As a NOx emission filter made of mordenite which has an excellent cation exchange capacity was manufactured by ball type adsorbents having excellent specific surface area. The adsorption efficiency of mordenite material applying the emission reduction filter began to show up at the operating time 10 minutes in comparison with the activated carbon and zeolite materials, and it was exposed to continue until 100% capability with passing by 20 minutes. So the adsorption efficiency of the NOx reduction filter consistently maintained at the averaged 80%.

A Study on the Test Method for Noise Reduction Devices Installed on the Noise Barriers (방음벽 상단 소음저감장치의 감음성능 평가방법 연구)

  • Kim, Chul-Hwan;Chang, Tae-Sun;Kim, Deuk-Sung;Kim, Dong-Jun;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.791-796
    • /
    • 2010
  • Installing noise barriers is the most common method for reducing the highway traffic noise to the road side residential area. After the report about edge potential concept of a noise barrier, various types of noise reducing devices(NRDs) called "noise reducers" have been suggested for getting more shielding effect on the top of highway noise barriers. But, it has been doubtful about effect of the NRDs in field because there was no appropriate and unified method to estimate the acoustic performance by using field measurement of the NRDs in Korea. In this study, the authors have considered to setup a practical method to test and estimate the acoustic performance of NRDs. For eliminating the noise reduction effect of the NRDs height itself, the source and measuring points are adjusted as highly as the NRDs height. For the frequency weighting in the estimation of the NRDs effect, the highway noise spectra were measured at asphalt and concrete road side and then averaged for a unit spectral parameter.

The Study on ODD Acoustic Noise Reduction by Using Micro Muffler (마이크로 머플러를 이용한 ODD소음 저감에 관한 연구)

  • Moon Byeong G.;Cha Sung W.;Lee young H.
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.197-202
    • /
    • 2005
  • Current Optical Disk drive is dominating high share gradually in information storage device market through development of great skill. These technologies can achieve not only improvement of transmission speed but also elevation of recording/reproduction technology. However, these present state cause not only the increase of vibration in structural viewpoint but also problem of serious noise while the ODD becomes high speed/high performance. Specially, air-born noise is being bigger than structural-born noise as disk rotation speed increases gradually. The object of this research is that reduce the air-born noise in optical disk drive by reducing a quantity of flow by using a miniaturized muffler. The micro muffler is a miniaturized muffler. The muffler is used widely by solution to reduce air-born noise which is generated by flow. According to frequency band of the noise source, it can be applied by muffler of various forms. In this research, we examined the noise characteristics of the micro muffler and applied it by noise reduction solution of the ODD. It could get an excellent noise reduction in high frequency band by using the micro muffler than the opened case through the decrease of an inner flow. But it could not get a noise reduction in low frequency band through the decrease of an inner flow.

  • PDF

Gas Sensing Properties of Powder Prepared from Waste Thermoelectric Devices by Wet Reduction Process

  • So, Hyeongsub;Im, Dong-Ha;Jung, Hyunsung;Lee, Kun-Jae
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.1
    • /
    • pp.90-93
    • /
    • 2018
  • In this study, n-type $Bi_2Te_3$ in thermoelectric scrap is recovered through a wet reduction process. The recovered powder (tellurium) is grafted onto gas sensor in a new application that is not a thermoelectric device. Bismuth-rich powder is prepared by adding hydrazine when pH of the solution is brought to 13 using NaOH. The pH of the filtered solution was reduced using $HNO_3$, and then hydrazine was added to perform the re-reduction reaction. The tellurium-rich powder can be obtained through this reaction. The elemental analysis for these powders is confirmed by energy dispersive X-ray spectroscopy (EDS) analysis ; the successful separation of bismuth and tellurium is confirmed. Separated tellurium powder is mixed with DMF solvent and ethyl cellulose binder to confirm gas sensing properties. The tellurium paste was exposed in $NO_x$ atmosphere and exhibited a rapid reaction rate and recovery rate of less than 3 minutes for the gas.