• Title/Summary/Keyword: Reduction Power

Search Result 4,679, Processing Time 0.035 seconds

Part-load Performance Characteristics of a Solid Oxide Fuel Cell/Gas Turbine Hybrid Power System Operating with Various Load-following Operation Modes (부하추종 운전방법에 따른 고체산화물 연료전지/가스터빈 하이브리드 동력 시스템의 부분부하 성능특성)

  • Kim Jae-Hoon;Yang Jin-Sik;Ro Sung-Tack;Sohn Jeong-Lak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.3 s.246
    • /
    • pp.193-200
    • /
    • 2006
  • The purpose of this study is to compare the part-load performance of a SOFC/GT hybrid power system with three different kinds of load-following operation modes. The primary mode for the part load operation of a hybrid power system is the reduction of supplied fuel (e.g., fuel control mode) to the hybrid system. The other two options, i.e., variable speed and VIGV controls, are related to the reduction of supplied air simultaneously with the reduction of supplied fuel to the system. With the performance analysis of a SOFC/GT hybrid power system, it is concluded that the variable speed con佐ol mode Provides the best performance for the part-load operations. It is also found that the VIGV control mode, with its better performance behavior than the fuel control mode, can be used as an important option for the part-load operation especially in case that the variable speed control mode can not be adopted.

A study on Source Stability Design Method by Power Integrity Analysis (전원무결성 해석에 의한 PCB 전원안정화 설계기법 연구)

  • Chung, Ki-Hyun;Jang, Young-Jin;Jung, Chang-Won;Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.7
    • /
    • pp.753-759
    • /
    • 2014
  • This paper introduces the reduction design technique of the resonance phenomenon of the inner PCB based on power integrity from the analysis about the inner power supply line generating RLC resonance. With the technique, the resonant frequency resulted from the structural characteristics of the PCB can be analyzed and allows to predict and the capacitor for resonance phenomenon reduction can be decided as a decoupling capacitor. From the simulation result, it was confirmed that the PCB's resonance phenomenon reduction design technique should have the reduction effect in the inner motherboard of the industrial controller. This research will be contributed to the improvement of the safety of a PDN (Power Delivery Network) structure in the layout design technique of the PCB.

A Study on Monitoring the Progressive Tax-based Power Charges Reduction Effects by Applying Fiber-based Artificial Vegetation System to Obsolete Houses (섬유기반 녹화시스템 적용에 따른 노후주택의 누진세기반 전력요금 저감효과에 대한 모니터링 연구)

  • Kim, Tae-Han;Lee, So-Dam
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.6
    • /
    • pp.67-77
    • /
    • 2017
  • Demands for housing has diversified recently due to low birth rate and the growth of aging population. Also, a share of idle houses and obsolete houses over 20 years old is gradually rising. Therefore, there is a need for a sustainable, environment-friendly improvement policy that is in line with a new housing paradigm and avoids full-scale new construction, such as a customized housing renovation plan considering local economic circumstances. Therefore, afforestation system applicable to buildings are assessed positively, but lack objective performance evaluation. Through one-year, long-term monitoring of replicated obsolete buildings that have poor insulation performance, this study calculated monthly average power consumption and analyzed power charges by applying pricing plans before and after the revision of progressive tax in order to examine economic effects expected by applying the afforestation system. In the obsolete buildings, the study showed that monthly average power consumption was reduced by 16.6kWh with 5.2% average reduction rate. Highest reduction was made in July at 11.3%. Aggregate monthly power consumption charges were relatively high in winter before and after the revision of progressive tax. Power charges reduction effect was highest in March when monthly power consumption was reduced to 300kWh level by applying the afforestation system.

Protection Assessment using Reduced Power System Fault Data

  • Littler, T.B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.172-177
    • /
    • 2007
  • Wavelet transforms provide basis functions for time-frequency analysis and have properties that are particularly useful for the compression of analogue point on wave transient and disturbance power system signals. This paper evaluates the compression properties of the discrete wavelet transform using actual power system data. The results presented in the paper indicate that reduction ratios up to 10:1 with acceptable distortion are achievable. The paper discusses the application of the reduction method for expedient fault analysis and protection assessment.

Peak-to-Average Power Ratio Reduction by Partial Parallel Transform in an OFDM-CDMA System (OFDM-CDMA 시스템에서 부분병렬환을 이용한 PAPR 감쇄기법)

  • 주양익
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.10A
    • /
    • pp.1548-1553
    • /
    • 2000
  • In this paper, an effective peak power reduction scheme for a downlink OFDM-CDMA system is proposed. Using the partial parallel transform(PPT) structure, peak-to-average power ratio(PAPR) can be reduced. The patterns of inputs of Inverse Fast Fourier Transform(IFFT) are more randomized in this structure by allotting the subcarriers to each users. At the cost of complexity we can obtain reduced PAPR and multiple access interference(MA) Computer simulations are carried out from the viewpoint of PAPR and demonstrated the improved PAPR performance.

  • PDF

Adaptive TR Scheme for PAPR Reduction in OFDM Systems (OFDM 시스템의 PAPR 감소를 위한 적응적 TR 기법)

  • Lim, Dae-Woon;Noh, Hyung-Suk;No, Jong-Seon;Shin, Dong-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.7C
    • /
    • pp.554-561
    • /
    • 2008
  • For the tone reservation (TR) scheme in orthogonal frequency division multiplexing (OFDM), there exists a trade-off between peak to average power ration (PAPR) reduction performance and data transmission rate. While PRT set is fixed in the conventional TR scheme, the proposed scheme adaptively select the PRT set according to the PAPR of the input OFDM symbol. It is shown that the PAPR reduction performance of the proposed scheme is better than that of the conventional scheme when the data transmission rate is the same.

Analysis of Grounding resistance reduction effect of Transmission tower (가공송전선로의 철탑 접지저항 저감효과 분석)

  • Min, Byeong-Wook;Kim, Tai-Young;Park, Bong-Gyu;Choi, Jin-Sung;Kang, Yeon-Woog;Park, Kwang-Uk;Bae, Hyun-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.453-454
    • /
    • 2011
  • With the transmission line the ratio of lightning breakdown the while whole breaking down is occupying a high share with average 72%, is a tendency which increases continuously. In order decreasing the back flashover faults from like this lightning breakdown, it is very important to maintain grounding resistance of tower below target. In this paper, we synthetically analyzed the grounding resistance reduction effect of tower foundation and standard ground connection from construction site, and investigated efficiency for ways to increase the length of counter poise and expand the size of conductivity concrete materials.

  • PDF

A Development of Efficient Power Conversion Technology for Reduction of Power Equipment (전원설비 저감을 위한 고효율 전력변환기술 개발)

  • Koo, Myoung-Wan;Lee, Woo-Won;Lim, Kye-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.142-144
    • /
    • 2008
  • The Former High Efficiency Inverter(the power restoration process) system process has advantage which is the energy reduction rather than the Former Inverter(the resistence damping process), However, under repair and remodeling, the power facilities capacity is not easy to increase that the former High Efficiency Inverter needs to increase the Power Facilities Capacity of 20~30% than the Inverter(the resistence damping process) so Therefore we are going to suggest the system which is not going to make an increase the power facilities capacity and is applicable the High Efficiency Inverter.

  • PDF

A Simple ZVT PWM Single-Phase Rectifier with Reduced Conduction Loss and Unity Power Factor

  • Kim, In-Dong;Choi, Seong-Hun;Nho, Eui-Cheol;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.55-63
    • /
    • 2007
  • This paper proposes a simple unity power factor zero-voltage-transition (ZVT) pulse-width-modulated (PWM) single-phase rectifier, which features reduced switching and conduction losses. The switching loss reduction is achieved by a simple auxiliary commutation circuit, and the conduction loss reduction is achieved by employing a single-stage converter, rather than a typical double-stage converter comprising of a front-end rectifier and a boost rectifier. Furthermore, thanks to good features such as a simple PWM control at constant frequency, low switch stress, low Var rating of commutation circuits, and simple power circuit structure, it is suitable for high power applications. The principles of operation are explained in detail, and a major characteristics analysis and the experimental results of the new converter are also included in this paper.

Reconfiguration of the Power Mix in Korea with the Introduction of Shale Gas and Analysis of Its Impact on Atmospheric Environment (셰일가스 도입으로 인한 전원믹스 재구성 및 환경 영향 분석)

  • Choi, Narae;Yeo, Minjoo;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.10 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • In line with the expected price reduction of natural gas associated with the introduction of shale gas, it is expected that the optimal power mix for the electric power generation be changed. In this study, the reconfigured power mix is estimated with the varying natural gas price by using the Screening Curve Method (SCM). It is found that about 3% and 9% coal in the overall power mix is replaced with natural gas if the natural gas price falls 20% and 40% of the current price, respectively. It is also found that the reconfigured power mixes would provide the reduction of the emissions of air pollutants which are equivalent to 369 and 807 MUS$.