• 제목/요약/키워드: Reducing facility

검색결과 320건 처리시간 0.028초

INCIDENT FREQUENCY AND SEVERITY FOR CONSTRUCTION FACILITIES

  • Jong-Hyun Park;Jae-Su Jeong;Chan-Sik Lee
    • 국제학술발표논문집
    • /
    • The 4th International Conference on Construction Engineering and Project Management Organized by the University of New South Wales
    • /
    • pp.234-240
    • /
    • 2011
  • Preventing incidents occurred in construction process is important for safe implementation of construction projects. Due to the complexity and magnitude of the project and moreover, poor safe planning and management, construction incidents in Korea have been increasing. Reducing construction incidents effectively, appropriate safety management program in consideration of the incident rate of each facility is to be adapted. This study analyzes incident frequency and severity rate of each facility based on the data of construction sites(about 1,560 thousand cases) recorded by Korea Occupational Safety & Health Agency for 3 years from 2007 to 2009, and the incident related data (about 40 thousand cases) of Korea Workers' Compensation & Welfare Service. The results of this study revealed that construction incident rates of 'cold refrigeration storage facilities' are the highest among building types, followed by traditional building religious building, arcade department store and shopping center. In case of other facilities, the incident rate and the rate of intensity of 'pipelining project' are the highest, followed by 'tunneling project'. These results would be used in providing safety programs beneficial for preventing construction incidents.

  • PDF

방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(2) - 음압레벨에 의한 평가 - (Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(2) - Estimation by Sound Pressure Level -)

  • 김철환;장태순;이기정;김동준;정태량;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1125-1128
    • /
    • 2007
  • In order to improve the acoustic performance of a noise barrier without increasing its height, various type of acoustic devices are suggested but, there is no proper method to estimate the performance in Korea. For this, an outdoor test facility was established in Expressway and Transportation Technology Institute(ETTI) of Korea Expressway Corporation for testing the acoustical performance of noise reducing devices installed on the top of a noise barrier. Noise measurements before and after installation of the noise reducing devices were carried out by using sound pressure level for long distance range from the barrier, from 10m to 40m. For considering the directivity effects of noise reducing devices, multivariate regression analysis was attempted.

  • PDF

상수도관로 누수신호의 특성 분석을 위한 누수 실험시설 개발 (Development of leakage test facility for leak signal characteristic analysis in water pipeline)

  • 박상혁;곽필재;이현동;최창호
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.459-469
    • /
    • 2017
  • A real scale leakage test facility was developed to study the leak signal characteristics of water supply pipelines, and then leak tests were carried out. The facility was designed to overcome the limited experimental circumstances of domestic water supply pipeline experimental facilities. The length of the pipeline, which was installed as a straight line, is 280m. Six pipes were installed on a 70m interval with different pipe material and diameters that are DCIP(D200, D150, D100, D80), PE(D75) and PVC(D75).The intensity of the leakage is adjusted by changing the size of the leak hole and the opening rate of ball valve. Various pressure conditions were simulated using a pressure reducing valve.To minimize external noise sources which, deteriorate the quality of measured leak signal, the facility was built at a quiet area, where traffic and water consumption by customers is relatively rare. In addition, the usage of electric equipment was minimized to block out noise and the facility was operated using manual mode. From the experimental results of measured leakage signal at the facility, it was found that the signal intensity weakened and the signal of high frequency band attenuated as the distance from the water leakage point increased.

서울지역 대형연소시설에서의 질소산화물 배출계수 산정 (The Evaluation of NOx Emission Factor from Large Combustion Facilities in Seoul)

  • 조기찬;최종욱;박후경;유병태
    • 환경위생공학
    • /
    • 제15권4호
    • /
    • pp.78-83
    • /
    • 2000
  • The emission factor of nitrogen oxides(NOx) was evaluate to clarify the characteristics of NOx emitted from seven large combustion facilities in seoul area. The emission factors of NOx at A-1 and A-2 facilities of internal combustion engine were 66.957kgNOx/ton and 20.913kgNOx/ton, respectively. The emission factor of A-1 facility was higher than that of A-2 facility even same internal combustion engine, because A-1 facility adopted SCR(selective catalystic reactor) for reduction of NOx emission factor of A-2, A-4, and A-7 power generation boiler facilities were 4.300kgNOx/ton, 2.460kgNOx/ton and 1.796kgNOx/ton, respectively. The capacity of A-2 facility was about two times than that of A-4 and A-7. These emission factors were lower than those at facilities in other areas of korea, because of using low NOx burner of power generation boiler. The emission factors of NOx at A-3 and A-6 incinerator facilities were 0.147kgNOx/ton and 0.221kgNOx/ton which were lower than other facilities, respectively, because these facilities incinerate municipal solid waste of low heating value and uwe SCR for reducing NOx concentration.

  • PDF

비 영역 업무공간과 일반 업무공간의 개선 우선순위 비교연구 (A Comparative Study on the Improvement-required order of Non-territorial office and Territorial office)

  • 조지연
    • 한국디지털건축인테리어학회논문집
    • /
    • 제7권2호
    • /
    • pp.51-58
    • /
    • 2007
  • The saying likely as "In the rapidly-changing outside management environment, the light-weighted body only able to survive" means the 'lightness' in working space, reducing expenditure for immovable property and unnecessary facility, and also means the flexibility of facility which is ready to cope promptly with the approaching situation. For such reason, as many enterprises do not support an individual workstation for each person but by introduction of sharing system, also reducing the area for working space, they have made the immovable property expense per person curtailed. Though the reduction of the immovable property expense that subsequently gained by merely decreasing of working space brings a remarkable effect of retrenchment, there is also a worrying opinion that because of the narrowed working space than before, or by disappearing of private space, a possible non-productive effect which let working enthusiasm falls down might be brought. By practicing such investigating method, at the first stage survey, the Satisfaction of non-territorial and territorial office user and the order of required improvement are figured out, also arranged the appraisal items as 6 factors in total, and all of the factors were being influenced to the entire satisfaction in statistically meaningful level.

  • PDF

실규모 연속유입간헐폭기 공정(ICEAS)에서 최적운전조건이 경제성에 미치는 영향 (Economic implications of optimal operating conditions in a full-scale continuous intermittent cycle extended aeration system (ICEAS))

  • 정용재;최윤성;이승환
    • 상하수도학회지
    • /
    • 제38권1호
    • /
    • pp.29-38
    • /
    • 2024
  • Wastewater management is increasingly emphasizing economic and environmental sustainability. Traditional methods in sewage treatment plants have significant implications for the environment and the economy due to power and chemical consumption, and sludge generation. To address these challenges, a study was conducted to develop the Intermittent Cycle Extended Aeration System (ICEAS). This approach was implemented as the primary technique in a full-scale wastewater treatment facility, utilizing key operational factors within the standard Sequencing Batch Reactor (SBR) process. The optimal operational approach, identified in this study, was put into practice at the research facility from January 2020 to December 2022. By implementing management strategies within the biological reactor, it was shown that maintaining and reducing chemical quantities, sludge generation, power consumption, and related costs could yield economic benefits. Moreover, adapting operations to influent characteristics and seasonal conditions allowed for efficient blower operation, reducing unnecessary electricity consumption and ensuring proper dissolved oxygen levels. Despite annual increases in influent flow rate and concentration, this study demonstrated the ability to maintain and reduce sludge production, electricity consumption, and chemical usage. Additionally, systematic responses to emergencies and abnormal situations significantly contributed to economic, technical, and environmental benefits.

악취 발산감소를 위한 필터의 이용 효과 (Effect of Biofilter on Reducing Malodor Emission)

  • 김원영;정광화;노진식;김원호;전병수;류호현;전영륜
    • 한국축산시설환경학회지
    • /
    • 제4권2호
    • /
    • pp.161-166
    • /
    • 1998
  • Controlling malodor originating from livestock feces has become a major issue, due to its influence on the health of man and livestock, together with its influences on atmospheric pollution. In this study, Five types of biofilters filled with saw-dust, night soil, fermented compost, leaf mold and a mixture(a compound of night soil, fermented compost and leaf mold at the same rates, respectively) were manufactured and tested. To study the effect of the biofilter on reducing malodor in a composting facility and swine building, a pilot scale composting facility enclosed with polyethylene film was constructed. Swine feces was composted in the facility and malodorous gas generated from the decomposition of organic matter in the feces was gathered by vacuum pump. Each biofilter achieved 87∼96% NH3 removal efficiency. This performance was maintained throughout 10 days of operation. The highest NH3 removal efficiency was achieved by leaf mold on the first day of operation period. It reduced the concentration of NH3 by about 96%. Night soil and fermented compost showed nearly equal performance of 93 to 94% for 10 days from the beginning of operation. The mixture achieved the lowest NH3 removal efficiency. It reduced NH3 concentration by about 89∼94% for 10 days from the beginning of operation. However NH3 removal efficiency of each biofilter declined with the passage of operational time. After 30 days from the beginning of operation, NH3 removal efficiency of each biofilter of each biofilter was below 60%, respectively. The concentration of H2S and CH3-SH originating from compost were equal to or less than 5mg/l and 3mg/l, respectively. After passing throughout the biofilter, the concentration of H2S and CH3-SH were not detected.

  • PDF

치매노인을 위한 노인요양시설의 배회 공간 특성 분석 (Analysis on Wandering Space Design of Elderly Care Facilities for the Elderly with Dementia)

  • 김미정;이소영
    • 한국실내디자인학회논문집
    • /
    • 제20권6호
    • /
    • pp.331-339
    • /
    • 2011
  • The purpose of this study was to examine wandering behaviors of the elderly with dementia at elderly care facilities, thus finding out the current status of supportability and safety of wandering space for facility residents and looking into the convenience of management for the control and Support of the elderly with dementia in wandering space, from the aspect of managers. Study methods consisted of literature examination, on-site assessment and investigation, observation and questionnaire survey. And via a questionnaire survey of facility workers at study subject facilities, the current status and facility workers' perception of wandering space and their job-satisfaction were examined. Collected data of 133 respondents were used for analysis. Data were processed with the SPSS 18.0 program, and such analytic techniques as frequency, percentage, mean, multiple response analysis, chi-square test and correlation analysis were carried out. The problems of physical environment of wandering space for the elderly with dementia: First, it is urgent to establish wandering space. Second, thoughtlessly installed chairs in the corridor impeded wandering behaviors. Third, the grips installed in the corridor space were irregular, thus causing inconvenience for wandering behaviors. Thus making residents' use of it difficult. In order to improve these problems, it is necessary to newly or additionally establish wandering space and modify the location of chairs or establish alcoves, thus reducing impedimentary elements for wandering behaviors. Providing a proper wandering space is important for facility residents. And it is also important for facility workers to manage facility residents.

2차원 CAD 건설도면과 공간DB 갱신기술을 활용한 시설물 유지관리 방안에 대한 연구 (A Study on A Facility Maintenance Management Method Using 2D CAD and Spatial Database Update Techniques)

  • 고원근;박형근
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2008년도 정기학술발표대회 논문집
    • /
    • pp.670-673
    • /
    • 2008
  • 본 연구는 시설물의 2D 건설도면과 공간 DB 갱신기술을 활용하여 시설물 유지관리의 체계적이고 효율적으로 수행하기 위한 방안 제시를 목적으로 한다. 기존의 유지관리 시스템 운영 및 업무 수행시에는 시설물 건설도면 정보의 활용이 미비한 실정이다. 또, 시설물 관리주체에서 운영 중인 유지관리 시스템 조사 분석을 통해 시설물 유지 보수에 대한 이력과 유지관리 시 얻어진 시설물 건설도면 정보의 DB 갱신의 관리가 체계적으로 수행되지 않는 문제점과 시설물 내 외부 위치정보의 부재에 대한 유지관리 업무의 효율성 저하 등에 대한 문제점을 도출하였다. 이를 바탕으로 기존의 시설물 2D 건설도면과 공간 DB 갱신 기술을 활용한 유지관리 이력 및 정보의 체계적인 관리와 시설물 위치정보 제공을 통한 효율적인 업무 수행을 위한 방안을 제시한다.

  • PDF

풍동시험과 CFD를 통한 방풍망의 풍속저감 효과 (Effects of an Anti-wind Net on Wind Velocity Reduction by a Wind Tunnel Test and CFD)

  • 염성현;강승희;김승희;이상봉;김민영
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.355-360
    • /
    • 2011
  • This study was carried out to analyze the installation effect of an anti-wind net on reducing wind velocity which was used to protect orchards as well as single-span plastichouses. The pressure drop through three types of anti-wind net was measured in a subsonic wind tunnel. The wind reduction through the anti-wind facility for several sets in respect to three types of the net and heights of the facility ranging from 3 to 11 m was analyzed by using computational fluid dynamics (CFD). The measured data showed that the pressure drop increased as an equation of the second degree of the inlet wind velocity. Numerical computations exhibited that the effect of wind reduction definitely augmented as the net size became smaller and increased with the height of the facility being heightened to some extent. For the typical and widely used anti-wind facility with a height of 5 m and a net size of 4mm, the amount of wind reduction came up to 5.1 m/s for the inlet wind velocity of 20 m/s, and also 7.6 and 10.1 m/s for the inlet wind velocities of 30 and 40 m/s, respectively. In case for the orchard's longitudinal length to be within about 200 m, the appropriately effective height of the facility was predicted to be 5 m. Finally, the negative total pressure on the top face of the single-span plastichouse certainly reduced for all the cases with the anti-wind facility being installed. In particular, the reduction of the negative total pressure was more considerable as the inlet wind velocity increased.