• Title/Summary/Keyword: Reduced scale test

Search Result 486, Processing Time 0.03 seconds

A Study on the Insertion Loss of Noise Barrier with the Variation of Top Shape (방음벽 상단부 형상에 따른 삽입손실 연구)

  • 정성수;김용태;이우섭
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.7
    • /
    • pp.624-631
    • /
    • 2002
  • The insertion loss of the noise barriers with several top shape is measured in an anechoic room by using a reduced scale model test. The insertion loss differences between a straight vertical barrier having 0.3 m height and several barriers with simple top shaped are compared. The results show that the latter is more effective than the former and absorptive barrier is more effective than the reflective one. Among the barrier types of 'T', 'Y', and '(equation omitted)', type 'Y' is the best one and the rest have similar effect. This result is well agree with Alfredson (PIOC. Inter-Noise 95, p. 381, 1995)'s but contradict to May (J. Sound Vb. 71, p. 73, 1980)'s. Therefore, it is difficult to determine which type is the best. In order to find out this discrepancy, boundary element method is adopted and the result shows one can have different result because each supposed different experimental conditions like height of noise barrier, positions of sound source and receiver, etc.

Effect of Rack Compartment using Barriers on Reducing the Fire Spread (차단막에 의한 랙크 구획화가 화재확산 저감에 미치는 영향)

  • Cho, Gyu-Hwan;Yeo, In-Hwan
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.66-75
    • /
    • 2018
  • A barrier installed within a rack plays a significant role in delaying the initial spread of fire but it can be an obstacle to a ceiling-type sprinkler installed for extinguishing fires and for supplying fire extinguishing water. An in-rack sprinkler and a barrier can be applied at the same time, but a study on a barrier's ability to delay fire spread or its effect on the in-rack sprinkler is needed. Accordingly, this study examined the effect of a barrier on the delay of fire spread and the in-rack sprinkler according to installation conditions through the reduced scale fire test. As a result, the delay in fire spread increased more than four times when a horizontal barrier and a vertical barrier were installed at the same time. The temperature was also increased two to three times with the compartment, resulting in the early operation of the in-rack sprinkler.

A Comparative Study on The Effect of Cupping and Moxibustion Therapy on Treating Constipation of Stroke Patients (부항-뜸 병행치료와 뜸 단독치료가 뇌졸중 환자의 변비 완화에 미치는 효과 비교)

  • Kim, Gyeong-Cheol;Kim, Yi-Soon;Lee, Hai-Woong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.13 no.3
    • /
    • pp.101-112
    • /
    • 2009
  • Objectives : This comparative study aimed to identify the effect of the Buddeumi(cupping-and-moxibustion device) therapy and moxibustion-only therapy on treating constipation of stroke patients who were admitted in the hospital of oriental medicine. The research design was a nonequivalent control group pretest-posttest design. Methods : The subjects of the study consisted of 23 stroke patients, and they were divided into two groups : one was the experimental group of 11 patients and the other was the control group of 12 patients. The Buddeumi therapy and the moxibustion-only therapy were given respectively. Each Buddeumi and moxibustion-only therapies on the 天樞(ST25, right & left) in abdomen were administered to the each group for 40 minutes a total at 10 times. The posttest included the frequency of defecation with the Constipation Assessment Scale every day for one week after the experiment. The data were analyzed by the $x^2$ test, t-test, Fisher exact test, and repeated measures ANCOVA using SPSS/WIN 12.0 program. Results : The results were as follows : First, Hypothesis 1 : 'The patients who are given the Buddeumi therapy in the experimental group have a lower Constipation Assessment Scale than the control group.' was supported(F=4.367, P=0.049). Second, Hypothesis 2 : 'The patients who are given meridian acupressure in the experimental group have a higher frequency of defecation per week than the control group.' was supported(F=0.947, P=0.034). Accordingly, 'The patients who are given the Buddeumi therapy in experimental group have a higher effect on constipation than the control group.' was supported. Conclusion : The Buddeumi therapy reduced the constipation assessment scale of stroke patients and increased the frequency of their defacation per week. Therefore, the Buddeumi therapy could be an effective treatment for constipation of stroke patients.

  • PDF

Verification of the Appropriateness of the Standard for Tunnel Luminance in the Threshold Zone Through a Full-scale Tunnel Driving Test (실 규모 터널 주행실험을 통한 터널 경계부 휘도 기준의 적정성 검증)

  • Park, Won Il;Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.105-115
    • /
    • 2015
  • PURPOSES : This study aimed to evaluate the appropriateness of safety with the standard for threshold zone luminance as specified in the Recommendation for Lighting of Traffic Tunnel, which has been widely adopted worldwide. METHODS : A driving test of the subject in a full-scale road tunnel was conducted. The adaptation luminance and threshold zone luminance, which should be known for the driver to perceive an object within stopping sight distance, were obtained. These values were compared with the adaptation luminance and threshold zone luminance obtained by the existing reduced model test and tunnel lighting standard that has served as a guideline for the current threshold zone luminance standard. RESULTS : According to this study, threshold zone luminance should be increased to at least 1.8 times the value proposed in the existing studies and to twice the domestic tunnel lighting standard (KS C 3703: 2014). CONCLUSIONS : The threshold zone luminance proposed in this study differs largely from that obtained from indoor tests and from the current tunnel lighting standard used worldwide; this difference may be attributed to the fact that the indoor tests did not incorporate driving workload, non-uniformity of luminance distribution in terms of sight, and factors that reduce the visibility of the driver, such as the light reflected into the driver's eyes. Hence, it is necessary to further review the factors that reduce the visibility of drivers approaching tunnels in order to determine the rational tunnel threshold zone luminance.

Evaluation of Applicability and Economical Efficiency of Peroxone Process for Removal of Micropollutants in Drinking Water Treatment (정수처리에서 미량유해물질 제거를 위한 Peroxone 공정의 적용성 및 경제성 평가)

  • Son, Hee-Jong;Kim, Sang-Goo;Yeom, Hoon-Sik;Choi, Jin-Taek
    • Journal of Environmental Science International
    • /
    • v.22 no.7
    • /
    • pp.905-913
    • /
    • 2013
  • We compared the applicability and economical efficiency of peroxone process with those of ozone process in the existing water treatment plant on downstream of Nakdong River. After comparing the peroxone process for removing geosmin with the ozone process in lab scale test, peroxone process showed much higher removal efficiency than the ozone process at the same ozone dosage. Proper range of $H_2O_2/O_3$ ratio were 0.5~1.0 and the half-life of geosmin was about 5.5~6.8 min when the $H_2O_2/O_3$ ratio was set to 0.5 during 1~2 mg/L of ozone dosage. Peroxone process could reduce the ozone dosage about 50 to maximum 30% for the same geosmin removal efficiency compared to the ozone process in the pilot scale test. In case of 1,4-dioxane treatment, peroxone process could have 3~4 times higher efficiency than ozone process at the same ozone dosage. The results of estimating the economical efficiency of ozone and peroxone process for treating geosmin and 1,4-dioxane by using pilot scale test, in case of the removal target was set to 85% for these two materials, the cost of peroxane process could be reduced about 1.5 times compared to ozone process, and in the same production cost peroxone process could have 2~3 times higher removal efficiency than ozone process. The removal efficiency by peroxone process showed a large difference depending on the physicochemical characteristics of target materials and raw water, therefore detailed examination should be carried out before appling peroxone process.

Effects of PZ Strength on Cyclic Seismic Performance of RBS Steel Moment Connections (RBS 철골모멘트접합부의 내진성능에 대한 패널존 강도의 영향)

  • Lee, Cheol-Ho;Kim, Jae-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.3 s.49
    • /
    • pp.149-158
    • /
    • 2006
  • The reduced beam section (RBS) steel moment connection has performed well in past numerous tests. However there still remain several design issues that should be further examined. One such issue on RBS connection performance is the panel zone strength. Although a significant amount of test data are available, a specific recommendation for a desirable range of panel zone strength versus beam strength has yet to be proposed. In this paper, the effects of panel zone strength on the cyclic performance of RBS connection are investigated based on the available test database from comprehensive independent testing programs. A criterion for a balanced panel zone strength that assures sufficient plastic rotation capacity while reducing the amount of beam buckling is proposed. Numerical studies to supplement the test results are then presented based on the validated finite element analysis. Satisfactory numerical simulation achieved in this study also indicates that numerical analysis based on quality finite element modeling can supplement or replace, at least in part, the costly full-scale cyclic testing of steel moment connections.

New Topology for Valve Performance Test Equipment of MMC based STATCOM (MMC 기반 STATCOM 용 밸브의 성능시험 장치를 위한 새로운 토폴로지)

  • Bae, Jongwoo;Jung, Jae-Hun;Nho, Eui-Cheol;Chung, Yong-Ho;Baek, Seung-Taek;Lee, Jin-Hee;Kim, Young-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • This study proposes a new topology for the performance test of a valve consisting of a modular multilevel converter (MMC)-based static synchronous compensator (STATCOM). The conventional valve performance test equipment requires high-voltage AC source of several kV rating because the number of submodules to be tested in a valve should be at least six or eight. However, the power source of the proposed scheme is DC and not AC source. The DC power source voltage range of the proposed test circuit is from several volts to several tens of volts. Therefore, the size and cost for the performance test equipment can be reduced considerably compared with the conventional method. The proposed scheme satisfies the requirements of the IEC 62927 standard. Simulations are conducted for a valve of 50[MVA] MMC-based STATCOM. Experimental results with a scale-downed setup show the validity of the proposed performance test topology.

Seismic Performance of Wide Flange Beam-to-Concrete Filled Tube Column Joints with Stiffening Plates around the Column (사각판 스티프너로 보강한 콘크리트 충전강관 기둥과 H형강 보 접합부의 내진성능)

  • Park, Jong Won;Kang, Seoung Min;Kim, Wook Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.2
    • /
    • pp.167-174
    • /
    • 2003
  • This paper presented the results of cyclic loading tests of 7 full-scale beams to column subassemblages with improved connection detail i.e., fillets of the stiffening plates at the column corners and ends of the stiffener-to-beam flange weld. Major findings from the test results were: (1) Fillets reduced the stress concentrations that may cause early brittle fractures and considerably improved the cyclic performance compared to the detail without fillets. (2) As the width of the stiffening plate increased, the stiffness and peak strength increased and energy dissipation capacity decreased. (3) While all specimens failed by a fracture, they could develop a total rotation of 0.04 radian required for special moment resisting frames.

Communications and Family Stress Between Mother and Adolescent (어머니와 청소년자녀의 의사소통유형지각과 가족스트레스)

  • 김오남
    • Journal of the Korean Home Economics Association
    • /
    • v.32 no.3
    • /
    • pp.105-120
    • /
    • 1994
  • The purposes of this research are to find out general trends of mother-adolescent communication and family stress to estimate the differences of communication patterns and family stress according to sociodemographic and communication variables and to analyze communication variables influencing on family stress. The samples were selected from high school students and their mothers and 342 couples were used in final analysis. Barnes & Olson(1982)'s parent-adolescent communication scale(PACI) and McCubbin(1981)'s family stress scale(FILE) were used to measure mother-adolescent communication pattern and family stress. The data were analyzed by frequency, percentage, mean, Chi-square, F-test Duncan-test, multiple regression, Pearson's r, and Chronbach's α. The result are summerized as follows: 1) Mothers highly perceived mother-adolescent open communication pattern but adolescents highly revealed mother-adolescent close communication pattern. The general trends of family stress showed that adolescents stress is higher than mothers. 2) Communication patterns showed significant differences in mother's age, adolescent's sex and communication variables in mother's education and conversation variables. Generally when mothers and adolescents communicated insufficiently and were not satisfied with communication patterns family stress was increased. 3) Family stress was significantly different in communication patterns. Form the regression analysis it was found that communication patterns are crucial to family stress. Especially open communication pattern between mothers and adolescents was the most important among the communication patterns for family stress was reduced.

  • PDF

The Treatment of Volatile Organic Compounds Using a Pilot-Scale Biofilter (Pilot 규모의 바이오필터를 이용한 휘발성유기화합물질 제거)

  • Son, Hyun-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.245-252
    • /
    • 2004
  • Two biofilter tests were conducted under different operating conditions. Test # 1 was performed to treat VOCs generated from a paint booth. The second test was performed to treat VOCs generated from chemical manufacturing processes. The volume of biofilter media was 4.3 $m^3$. For the test # 1, the biofilter was operated for 30 days with 99.9% reduction ratio. Range of temperature of each stage of the biofilter media was measured between $34^{\circ}C$ and $73^{\circ}C$. All the temperatures of stages reduced gradually after the initial dramatic increase. For the test # 2, the biofilter experiment was conducted for 14 days. In this case, the biofilter was installed outdoor and the experiment was performed during wintertime. Therefore, temperature management for the biofilter was needed. Seven-centimeter thick fiberglass insulation and $150^{\circ}C$ steam heating were used to overcome the outside freezing cold weather during test # 2. Temperature of stage # 5 was measured the highest and that of stage # 1 was the lowest. More acclimation time and test period was needed to determine the maximum loading rate.