• Title/Summary/Keyword: Reduced scale experiment

Search Result 191, Processing Time 0.028 seconds

Analysis on Ablation of KL-3 Engine Nozzle Throat Using Image Analysis (영상분석을 통한 KL-3 엔진 노즐목 삭마 경향 분석)

  • Kim, Young-Han;Park, Sung-Jin;Ryu, Chul-Sung;Kim, Yong-Wook;Han, Sang-Yeop;Kim, Byung-Hun
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.51-55
    • /
    • 2003
  • In this research, authors tried to measure the shape of the nozzle throat of KL-3 engines, which is the main engine of KSR-III rocket, to find the increase of nozzle area caused by the thermal ablation. For the purpose, we invented an image-based method instead of the 3D pointer, which is actually inaccessible to such large scale engines. As a result, our equipment showed satisfactory accuracy and performance. Analysing the results of experiments, we find that the pattern of ablation is determined by the spray pattern and that the process of thermal ablation phenomena can be categorized in three regimes - the first regime that the shape of nozzle throat is maintained and ablation is negligible, the second regime that saw-tooth form is developed and ablation is accelerated, and the third regime that the saw-tooth form is already established and the growth of ablation rate is reduced. Also, we find that the ratio of area increase after 60 seconds combustion is +5.82% and conclude that this figure is acceptable and satisfactory.

  • PDF

Development of a Ultrasonic System for Nano-Surface Reformation Process

  • Kim, Hyunse;Lim, Euisu;Park, Jong-Kweon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.4
    • /
    • pp.365-370
    • /
    • 2017
  • In this article, a 20 kHz Titanium (Ti) ultrasonic waveguide system for a nano-surface reformation process was designed and fabricated. First, finite element analysis using ANSYS software was performed to find the optimal dimensions. The obtained anti-resonance frequency for the Ti transducer with the piezoelectric device was 20.0 kHz, which value agreed well with the experiment result of 20.1 kHz (0.5% error). To test the system, chromium molybdenum steel (SCM) 435 was chosen as a test-piece. The result proved that the reformed depth was $36{\mu}m$. In addition, hardness was measured before and after the process. The value was changed from 14 HRC to 21 HRC, which is 50% increasing rate. Finally, the friction coefficient test result showed that the surface coefficient was reduced from 0.14 to 0.10 (28.6% reduction). Based on the results, the Ti ultrasonic equipment is regarded as a useful device for nano-scale surface reformation.

HSPF Modeling for Identifying Runoff Reduction Effect of Nonpoint Source Pollution by Rice Straw Mulching on Upland Crops (볏짚 피복에 의한 밭 비점원오염 저감효과 분석을 위한 HSPF 모델링)

  • Jung, Chung-Gil;Park, Jong-Yoon;Lee, Hyung-Jin;Choi, Joong-Dae;Kim, Seong-Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • This study is to assess the reduction of non-point source pollution loads for rice straw surface covering of upland crop cultivation at a watershed scale. For Byulmi-cheon watershed ($1.21km^2$) located in the upstream of Gyeongancheon, the HSPF (Hydrological Simulation Program-Fortran), a physically based distributed hydrological model was applied. Before evaluation, the model was calibrated and validated using 9 rainfall events. The Nash-Sutcliffe model efficiency (NSE) for streamflow was 0.62~0.78 and the NSE for water quality (Sediment, T-N, and T-P) were 0.68, 0.60, and 0.58 respectively. From the field experiment of 16 rainfall events, the rice straw covering reduced surface runoff average 10 % compared to normal surface condition. By handling infiltration parameter (INFILT) in the model, the value of 16.0 mm/hr was found to reduce about 10 % reduction of surface runoff. For this condition, the reduction effect of Sediment, T-N, and T-P loads were 87.2, 28.5, and 85.1 % respectively. The rice straw surface covering was effective for removing surface runoff dependent loads such as Sediment and T-P.

Effect of UV Irradiation and TiO2 Addition on the Ozonation of Pyruvic Acid (피루브산의 오존산화반응에 미치는 TiO2 첨가 및 UV 조사의 영향)

  • Lee, Cheal-Gyu
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.1
    • /
    • pp.23-29
    • /
    • 2016
  • Ozonation was investigated for its ability to remove pyruvic acid in a laboratory-scale batch reactor under various experimental conditions, including UV irradiation, TiO2 addition, and variations in temperature. An ozone flow rate of 1.0 L min-1 and a concentration of 75±5 mg L-1 were maintained throughout the experiment, and pH, COD, and TOC were measured at 10 min intervals during a 60 min reaction. Our results confirmed that the combination of UV irradiation and photocatalytic TiO2 in the ozonation reaction improved the removal efficiency of both COD and TOC in aqueous solution at 20℃. Pseudo first-order rate constants and activation energies were quantified based on the COD and TOC measurements. We observed that the O3/UV, O3/UV/TiO2 system increased mineralization and reduced the activation energy (Ea) necessary for pyruvic acid decomposition.

An Experiment Study for Flame Spread Prevention System of Snadwich Panels (샌드위치 패널의 화재확대 방지시스템 개발을 위한 실험적 연구)

  • Shin, Hyun-Joon;In, Ki-Ho;Yoo, Yong-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.6
    • /
    • pp.307-312
    • /
    • 2015
  • The sandwich panel is commonly used domestically because it's less costly and easier to handle. But fires have frequently occurred in buildings employing sandwich panels, such as the fires in Eecheon cold storage and in Gwangju Pyungdong industrial zone. Sandwich panels with steel plates on their surface prevent fire water from penetrating to the fire source, which makes it difficult to extinguish a fire in a timely manner. Toxic gas generated from some insulation material leads to serious loss of life and property. This study is intended to develop an extinguishing system for sandwich panels, thereby reducing the fire risk. Fire water and volume were determined in the wake of the study on the structure of a sandwich panel extinguishing system, and improvement and testing of the fire characteristics of the sandwich panel. Based on such study and test, a fire model test was conducted. Consequently, the sandwich panel with extinguishing system was proven to have a reduced fire risk, compared to traditional or fire retardant panels.

Visual Comfort Evaluation of Interior Spaces by Daylighting Systems (채광시스템 유형별 실내공간의 시각적 쾌적성에 관한 평가)

  • Jeong, In Young;Choi, Yoon Seck;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • Daylight is a critical factor in architecture, as it enhances the working efficiency and visual comfort of the people working inside. Even though, low transmittance glazing has been used in the most office buildings in Korea. And it is reduced visual comfort in a indoor environment. So, we need to evaluation of quality for various daylighting systems to improve visual comfort This study aims to evaluate the visual comfort in a indoor environment by different daylighting system. For the purpose, four different daylighting systems-conventional window, conventional window with interior lightshelf, differentiated window, differentiated window with interior lightshelf-were selected and a questionnaire survey with 50 subjects were conducted. The results are as follows. Regardless daylighting systems, a view has an effect on visual comfort. A conventional system and conventional system with lightshelf were highly correlated between comfort and warmth. In case of differentiated window system were correlated between comfort and openness. Also, differentiated window with interior lightshelf were highly correlated between comfort and stability.

Study for a Secondary Air Affecting Fluid Flow in a Solid Waste Incinerator (쓰레기 소각로의 2차공기가 유동현상에 미치는 현상 연구)

  • Lee, Geum-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.9
    • /
    • pp.2924-2932
    • /
    • 1996
  • As the environmental pollution can be greatly reduced and the waste heat can be also recovered through a combustion of municipal solid waste, the incineration begins to be highlighted recently in our country. But it is very difficult to be operated with constant combustion conditions for a long time as the domestic waste is composed of various components, contains a large percentage of water, and has a low heating value. Therefore, the cold flow test and partial hot flow test were conducted in the incinerator by use of injection angles of a secondary air affecting fluid flow as the first action to maintain the optimum combustion conditions. A model to a scale of 1:10 was designed and manufactured through the similarity of model and prototype flows. Velocities and temperatures were measured through the experiment. From the results, fluid flows of secondary air obtained from partial hot flow test correspond almost well with those of main flow obtained from cold flow test. Consequently, injection angles of secondary air are proved to affect main flow decisively.

A Study on the Characteristics of Smoke Control using PIV in Tunnel Fires (터널내 화재시 PIV를 이용한 연기제어 특성에 관한 연구)

  • Ko, Jae-Woong;Kim, Jong-Yoon;Seo, Tae-Beom;Lim, Kyung-Bum;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.6-11
    • /
    • 2006
  • This study aims to measure a smoke density and velocity by using the PIV method in case a fire occurs in tunnels. By doing so, this will estimate a critical velocity, examine its appropriateness, and present the basic materials necessary for designing a smoke control equipment. For this study, a visualization test was conducted based on the 1/20 miniature of a real tunnel according to the Froude scaling. As a part of basic experiments, a correlation between smoke density and brightness was analyzed here, and a critical velocity was estimated on the condition that a fire breaks out in tunnels. As a result, this study finds that there is a correlation between smoke density and brightness within a range of 100% to 30% transmittance, from which a quantitative smoke density can be obtained. The study also suggests that a critical velocity calculated from the Kennedy formula shows about 10% difference from that estimated in the test.

The Effects of Taping Treatment on Sports Injury of Knee, Three Case Reports (첩대요법으로 호전된 스포츠 슬관절 손상 환자 3례)

  • Ahn, Hee-Bin;Kim, Ji-Young;Kim, Soon-Joong;Jeong, Su-Hyeon
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.2
    • /
    • pp.1-11
    • /
    • 2011
  • Objectives : The purpose of this study is to access the taping treatment in patients with sports injury of knee. Methods : Three patients were treated by taping to evaluate the effect of the treatment. The patient's symptoms were assessed by range of motion(ROM), verbal numerical rating scale(VNRS), knee injury and osteoarthritis outcome score(KOOS) and physical examinations. Results : In all case, the pain was reduced according to VNRS score. ROM and KOOS of two cases were improved. Conclusion : These results suggest that taping might be an effective method to treat patients with sports injury of knee. But, it's necessary to have more observations and experiment with taping.

  • PDF

Analysis of Inner Temperature in High Strength Concrete under Standard Temperature-time Curve (표준화재곡선에 의한 고강도 콘크리트 부재의 내부온도 예측)

  • Song, Hun;Lee, Sea-Hyun;Mun, Kyung-Ju;Do, Jeong-Yun;Soh, Yang-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.469-472
    • /
    • 2005
  • With all ensuring the fire resistance structure as a method of setting the required cover thickness to fire, the RC is significantly affected from the standpoint of its structural stability that the compressive strength and elastic modulus is reduced by fire. Normally, the degradation of concrete member exposed to fire is largely dependent on the fire scale and fire condition. There is therefore a need to precisely predict the deterioration and fire damage of the exposed member. Thus, this work estimated the temperature distribution inside a member taking into consideration of the thermal properties by means of finite element method(FEM). The estimation results in a little higher prediction value than the experimental value in surface layer and is almost coincident with the experiment as the heating depth increase. From this work it can be known that the simulation application of FEM using the thermal properties of concrete member in high temperature gives rise to the confident prediction in the prediction of temperature distribution.

  • PDF