• Title/Summary/Keyword: Reduced scale experiment

Search Result 195, Processing Time 0.033 seconds

Experimental Study on the Small-Scale Rotor Hover Performance in Partial Ground Conditions (부분적 지면조건 하에서의 소형 로터 블레이드 제자리 비행 성능에 대한 실험적 연구)

  • Seo, Jin-Woo;Lee, Byoung-Eon;Kang, Beom-Soo;Oh, Se-Jong;Yee, Kwan-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.1
    • /
    • pp.12-21
    • /
    • 2010
  • This paper focuses on the hover performance experiment of a small-scale single rotor in partial ground conditions. In this study, small-scale rotor blade rotating device and floor panel are used to include partial ground effect. Thrust and torque were measured with varying collective pitch angles at fixed rotor rotating speed. The overlap distance between rotor and ground is d, the rotor diameter is D. It was shown that the ground effects have little effect on the rotor performance until d/D is 0.25. Four blade rotor has more increased thrust and more reduced power than those of two blade rotor because of stronger ground effect. In addition, it was also found that the thrust increases as a collective pitch angle become smaller. Based on these experiment results, we deduced new empirical equation considered blade number and partial ground effect.

Analysis on Effect of Energy Mitigation by Arrangement of Cylindrical Countermeasures through 3D Debris Flow Numerical Analysis (3차원 토석류 수치해석을 통한 원통형 대책구조물의 배치조건에 따른 에너지 저감효과 분석)

  • Kim, Beom Jun;Yune, Chan-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.621-630
    • /
    • 2023
  • In this study, to investigate an energy reduction effect by field application of cylindrical baffle arrays, the 3D Debris flow numerical analysis was conducted with various baffle configurations for the simulation of a real-scale valley, where the cylindrical baffle arrays were installed. For this, the valley of the watershed was modeled using terrestrial LiDAR data from the real-scale experiment site. Numerical analysis simulated the flow behavior of debris flow and the structures using Smooth Particle Hydrodynamics (SPH) technique of ABAQUS (Ver. 2021). The numerical analysis results that the case without cylindrical baffle arrays had a similar velocity change to that of the real-scale experiment. Also, the installation of baffles significantly reduced the frontal velocity of debris flow. Furthermore, increasing the baffle height increased the downstream energy reduction because of the higher flow impedance of taller baffles.

A Study on the Change of Indoor Heating Environment with the Creation of Indoor Water Space through a Scale Model (축소모형을 이용한 실내 수공간 도입 효과 연구)

  • Oh, Sang Mok;Oh, Se Gyu
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.67-72
    • /
    • 2010
  • This study was conducted to examine the change of heating environment with the creation of an indoor water space. Living environments and comfort of dwellers can be improved by utilizing the physical properties of water effectively. This study focuses on the basic examination of the effect of water space and the environmental effects of water space by experiment. Two identical models were fabricated to compare the changes in indoor temperature and humidity with and without a water space. With the water space, temperature was reduced by an average of $0.55^{\circ}C$ a day and moisture content increased by an average of 4%. As a result, it was possible to obtain quantitative data on water space's temperature reduction and humidity control capacities. This study is expected to provide basic information for further studies on the effect of water spaces in various buildings.

Noise reduction of noise barrier with noise reducer for high speed train by using scale down model test (축척모형 실험에 의한 고속전철 방음벽용 소음저감 장치)

  • 정성수;전병수;나희승;김준엽;양신추
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.647-652
    • /
    • 2001
  • A noise reduction of noise barrier for high speed train was measured by using scale down model test. A selected types of noise barriers were simple vertical barrier, interference type barrier with plate, interference type barrier with cylindrical pipes. On experiment, in order to make similar present test lane condition, reduced train model and multiple noise sources were considered. As a result. interference type noise barrier with cylindrical pipes is most effective than other barriers. A present height of noise barrier which is established in a test lane is not high enough for reducing patograph noise.

  • PDF

A study of estimation for excess attenuation of Noise propagated on the ground (지표면상을 전파하는 소음의 초과감쇠 산정방법에 관한 연구)

  • Oh, J.E.;Kim, D.G.;Yim, T.K.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.20-25
    • /
    • 1988
  • This study is to explain the characteristic of excess attenuation on the ground through the outdoors experiment about noise propagation and the reduced model experiment of acoustic. The outdoors experiment on the attenuation of noise propagation was tried with the small engine that had large acoustic output, and then it was conformed that there was relationship between the excess attenuation calculated by measurement from distance attenuation and Log(D/(Hs+Hr)). As a result, it was found that the attenuation of noise propogation depended upon the direction of the wind and frequency and was regressed in a straight line. And the numerical values of excess attenuation on the ground could be calculated by regarding Log(D/(Hs+Hr)) as a parameter with an airing resistance $\sigma$. It was found that when the mean square error between the excess attenuation calculated by measurement and the value calculated by a fomula $L=-20Log\mid1+(r_1/r_2)Qexp(ik, \bigtriangleup r)\mid$ about optional $\sigma$ was least, the optimal decision of u was made. As the characteristic of model is the model experiment on a reduced scale of 1 to 40, It was conformed that it corresponds enough with the measurement value with measuring the distance attenuation in the large anecoic chamber.

  • PDF

Studies on the Mackerel Purse Seine Operating in the Sea Area of Cheju Island - 2 . Model Experiment ob the Deformation of Net in Two Layer Current (제주도 주변 해역 고등어 포착망의 연구 - 2 . 이중조에 있어서 망의 변형에 관한 모형실험 -)

  • 박정식
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.4
    • /
    • pp.32-40
    • /
    • 1986
  • A model experiment of purse seine by the circulating water tank was carried out on the changes of net shape and the tension of purseline under operation in two layer current. In the circular tank, the two layer current was made by cutting off the current of upper layer and producing the bottom current by the equipment shown in Fig. 1. The model experiment of purse sein was made on a reduced scale 1 :400, and the experiment was carried out according to the Tauti's model law. When the bottom current of O. 5 knot flows to lower part of three-eighths of net, following results are derived. The depth of sinkerline reached only about 80% of that of no current set. The horizontal shift of sinker line caused by the bottom current is maximized in tight set. The enclosed area by the floatIine immediately after the completion of set net is 61. 5% in tight set, 50. 0 % in loose set and 54. 1 % in lateral set of those in the case of no current. In the first half period of pursing, the tension of the purseline is enhenced by the bottom current and the pattern of increasing is irregular in the tension curves.

  • PDF

DC Superconducting fault current limiter characteristic test with a DC circuit breaker

  • So, Jooyeong;Choi, Kyeongdal;Lee, Ji-kwang;Kim, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.2
    • /
    • pp.19-23
    • /
    • 2021
  • We have studied the breaking system that combines a resistive superconducting fault current limiter (SFCL) and a DC circuit breaker for DC fault current. To verify the design of the 15 kV DC SFCL, which was driven from the previous work, a 500 V DC system was built and a scale-down SFCL were manufactured. The manufactured SFCL module was designed as a bifilar coil which is a structure that minimizes inductive reactance. The manufactured SFCL module has been experiment to verify characteristics of the current-limiting performance in the DC 500 V system. Also, the manufactured FCL module was combined with the DC circuit breaker to be experimented to analyze the breaking performance. As a result of the experiment, when SFCL was combined to the DC circuit breaker, the energy dissipation received by the DC circuit breaker was reduced by up to 84% compared to when the DC circuit breaker operates alone. We are preparing methods and experiments for the optimal method for much higher performance as a future work.

Reduced-scale Model Experiment for Examination of Natural Vent and Fire Curtain Effects in Fire of Theater Stage (공연장 무대부 화재 시 자연배출구 및 방화막 영향 검토를 위한 축소모형 실험)

  • Baek, Seon A;Yang, Ji Hyun;Jeong, Chan Seok;Lee, Chi Young;Kim, Duncan
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.41-49
    • /
    • 2019
  • In the present experimental study, based on a real-scale theater, a 1/14 reduced-scale model was constructed, and the effects of natural vent and fire curtain in fire of a theater stage were investigated. The case without fire curtain under the opened natural vent showed lower temperatures in the stage, whereas the case with fire curtain under the opened natural vent showed lower temperatures in the auditorium. On the other hand, through analyzing the starting time of the temperature rise at the point near the proscenium opening in the auditorium, it was found that the opened natural vent condition can delay the starting time of smoke spread from the stage to the auditorium and suppress the temperature rise in the auditorium. Under the present experimental conditions, the fire curtain installation did not affect significantly the velocity and mass flow rate of the outflow through the natural vent of the stage, which might be due to openings in the stage. The present results can be used to examine the effects of natural vent and fire curtain in a real-scale fire of a theater and to check the accuracy of the numerical simulation code.

Shape Recognition Using Skeleton Image Based on Mathematical Morphology (수리형태론적 스켈리턴 영상을 이용한 형상인식)

  • Jang, Ju-Seok;Son, Yun-Gu
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.4
    • /
    • pp.883-898
    • /
    • 1996
  • In this paper, we propose improved method to recognize the shape for enhancing the quality of the pattern recognition system by compressing the source images. In the proposed method, we reduced the data amount by skeletonizing the source images using mathematical morphology, and then matched patterns after accomplishing the translation and scale normalization, and rotation invariance on the transformed images. Through the scale normalization, it was possible for the shape recognition at minimum amount of the pixel by giving the weight to the skeleton pixel. As the source images was replaced by the skeleton images, it was possible to reduce the amount of data and computational loads dramatically, and so become much faster even with a smaller memory capacity. Through the experiment, we investigated the optimum scale factor and good result was proved when realizing the pattern recognition system.

  • PDF

Effect of Self Resistance Exercise in Women with Frozen Shoulder (동결견을 가진 여성에 대한 탄력밴드 저항운동의 영향)

  • Nam, Kun-Woo;Ha, Mi-Sook
    • Journal of Korean Physical Therapy Science
    • /
    • v.19 no.2
    • /
    • pp.35-42
    • /
    • 2012
  • Background : This study was conducted to know the effect of resistance exercise using thera-band in parallel with conservative therapy in patients with frozen shoulder. Methods : We analyze subjective pain scale, ROM and shoulder functional scale 24 patients diagnosed with adhesive capsulitis were included for study. Among them, 12 patients(experiment group) were managed by resistance exercise as well as conservative physical therapy, another 12 patients(control group) were only treated by conservative therapy alone. All the patients were treated three times a week for 4 weeks, and after, and after each treatment subjective pain scale, ROM, shoulder functional score(SFI) were measured. Results : The VAS were significant reduced between experimental group and control group according to pre-treatment and post-treatment. In experimental group, the ROM and SFI has increased than control group according to pre-treatment and post-treatment. Conclusion : According to the results, we concluded that both conservative therapy and self resistance exercise using thera-band technique are more effective for increasing ROM especially flexion, abduction, internal rotation and SFI than conservative therapy alone.

  • PDF