• 제목/요약/키워드: Reduced Costs

검색결과 757건 처리시간 0.028초

Droop Control Method Based on Generation Cost in DC Microgrid

  • Hoang, Duc-Khanh;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.33-34
    • /
    • 2017
  • This paper presents a linear droop control scheme based on the generation costs of DGs in an autonomous DC microgrid. Unlike the proportional power sharing of the conventional droop control, in the proposed control algorithm, the minimum output voltage range is adjusted and the droop coefficients are regulated according to the generation costs of DGs. As a result, the DGs with lower costs supplies more power in comparison with those with higher costs. Therefore, total generation cost of the system is reduced significantly. The proposed method is simple to implement and it does not require the centralized controller and communication links.

  • PDF

Preoperative Serum Albumin Levels Predict Treatment Cost in Total Hip and Knee Arthroplasty

  • Rudasill, Sarah E.;Ng, Andrew;Kamath, Atul F.
    • Clinics in Orthopedic Surgery
    • /
    • 제10권4호
    • /
    • pp.398-406
    • /
    • 2018
  • Background: Hypoalbuminemia (serum albumin < 3.5 g/dL) is associated with increased morbidity and mortality in patients undergoing total hip arthroplasty (THA) and total knee arthroplasty (TKA). However, costs associated with hypoalbuminemia remain unknown. This study investigated the effect of serum albumin on direct treatment costs, length of stay (LOS), and readmissions for primary and revision THA and TKA patients. Methods: All adult patients at a single institution undergoing primary or revision THA or TKA between January 2014 and December 2016 were retrospectively reviewed. Patients were stratified by preoperative serum albumin level. The primary outcome was total direct costs at index hospitalization. Secondary outcomes included LOS and readmission within 30 days. Multivariable regressions were utilized to adjust for demographics and comorbidities. Results: Of 3,785 patients, 114 (3.0%) had hypoalbuminemia. After adjustment, hypoalbuminemia was associated with a 16.2% increase in costs (${\beta}=0.162$; 95% confidence interval [CI], 0.112 to 0.213; p < 0.001), representing an average cost increase of $3,383 (95% CI, $2,281 to $4,485) relative to costs for serum albumin > 4.5 g/dL. The increased total costs were significantly higher in revision ($4,322, p = 0.034) than in primary ($3,446, p < 0.001) procedures. In adjusted regression, each 1.0 g/dL increase in serum albumin yielded a 6.6% reduction in costs (${\beta}=-0.066$; 95% CI, -0.090 to -0.042]; p < 0.001), for average savings of $1,282 (95% CI, $759 to $1,806) per unit albumin. Adjusted regressions demonstrated that a 1-point increase in serum albumin reduced readmissions by 53% (odds ratio, 0.47; 95% CI, 0.31-0.73; p = 0.001) and LOS by 0.6 days (${\beta}=-0.60$; 95% CI, -0.76 to -0.44; p < 0.001). Conclusions: Hypoalbuminemia is associated with increased total direct costs, LOS, and readmissions following primary and revision THA and TKA. Future efforts to predict and address total costs should take into consideration the patient's preoperative serum albumin levels.

생애주기를 고려한 오피스 건물의 리모델링과 그린리모델링의 경제성 평가 연구 : 서울시 강남업무지구의 임대오피스 사례 (An Economic Evaluation Study of Office Remodeling and Green-remodeling Projects : A Simulation Approach to a Rental Office in GBD, Seoul)

  • 이성호;이재수
    • 대한건축학회논문집:계획계
    • /
    • 제34권3호
    • /
    • pp.23-34
    • /
    • 2018
  • Due to a waste of energy in korea, about 525,000 which are 75 percent of total buildings are at least 15 years old buildings that need remodeling. There are two current remodeling systems. One is a remodeling system to reduce a waste of resources from the reconstruction. The other is a green-remodeling system aimed to energy savings and reducing environmental costs. This study is to analyze quantitatively these current systems with respect to the cost-benefit caused by the life cycle and suggests the political and institutional implications through the interpretation of the results. For a quantitative analysis, we analyzed reducing maintenance costs and rent benefits with simulation by using opportunity costs, construction costs, plan costs and supervision costs as expense variables and using the reduced floor area ratio, institutional incentives, energy, water resources and certified emission reduction(CER) as benefit variables. As a result of the empirical study, the green-modeling was more beneficial in the field of environment such as the energy savings, however, the final benefits of remodeling which has no green building certification costs but more floor area ratio incentives were more economical. The green-remodeling system focused on reducing environmental costs and energy savings needs a equatable institutional incentive system.

국내 보급 예정 하이브리드 자동차의 유형별 편익 고찰 (A Study on the Feasibility of the Three Prospective Types of HEV)

  • 이동준;이예지;허은녕
    • 신재생에너지
    • /
    • 제4권2호
    • /
    • pp.52-60
    • /
    • 2008
  • More people have become interested in hybrid vehicles - which have been heralded as environmentally friendly automobiles - recently as the opening of domestic hybrid vehicle market draws near. Since gasoline, diesel and LPG hybrid vehicles will be produced, a need exists to conduct economic feasibility study of each vehicle type. This research analyzed projected benefits of these hybrid vehicles based on the 1600cc model. There are two categories of benefits: 1) reduced fuel costs for the owners of the vehicles; and 2) reduced environmental pollution cost. We conducted a sensitivity analysis and estimated the domestic consumer fuel costs based on the international oil prices of 100USD, 150USD, and 200USD per barrel. The analysis showed savings of 2 to 4 million Won in fuel cost and 1 to 2 million Won in environmental pollution cost; therefore, the hybrid vehicles are not economically feasible if they are between 3 to 5 million Won more expensive than the conventional internal combustion engine vehicles.

  • PDF

뺏치식 저압침탄 고압가스냉각 시스템 개발 (Development of Low Pressure Carburizing and High Pressure Gas Quenching System)

  • 장병록;한형기;김원배;동상근;김한석;조한창
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.78-84
    • /
    • 2005
  • The development of eco-friendly low pressure carburizing system with high pressure gas quenching (LPC_GQ, 500kg/charge) led to new stage in the fundamental case-hardening treatments. This is due to its ability to provide tighter tolerances on the carburizing process with notable reductions in distortion of the carburized and hardened workpiece. This system is characteristics by high uniformity and reproducibility of heat treatment results, absence of an intergranular oxidation layer, carburizing of complex shapes, reduced cycle time, low operating costs, simplified production, eliminate post washing, and reduced grinding costs.

  • PDF

Batch type 가스침탄 열처리로 국산화개발 (Development of High Performance Low Pressure Carburizing System)

  • 김원배;동상근;장병록;한형기;김한석;조한창
    • 열처리공학회지
    • /
    • 제19권5호
    • /
    • pp.262-269
    • /
    • 2006
  • The development of eco-friendly low pressure carburizing system with high pressure gas quenching(LPC-GQ, 500kg/charge) led to new stage in the fundamental case-hardening treatments. This is due to its ability to provide tighter tolerances on the carburizing process with notable reductions in distortion of the carburized and hardened workpiece. This system is characteristics by high uniformity and reproducibility of heat treatment results, absence of an intergranular oxidation layer, carburizing of complex shapes, reduced cycle time, low operating costs, simplified production, eliminate post washing, and reduced grinding costs.

정수장의 무성방전형 오존발생기 최적활용방안에 관한 연구 (A Study on the Optimal Use of Silent Discharge Type Ozonizer in Purification Plant)

  • 신홍섭;박현미;권영학;송현직;박원주
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.54-60
    • /
    • 2015
  • There are 5 purification plants with the adopted advanced water purification treatment process in Korea. Annual operating costs were 8,990 million won including purchase cost of oxygen and power usage charges. We need research to optimize, in the future, when considering the direction of domestic water treatment continues to adopt advanced water treatment process. In this paper, calculate the optimal operating costs by injected the oxygen gas, used power cost. approximately 25% of the operating costs can be reduced when injected the ozone gas is 1.0ppm than 2.0ppm, the necessary amount of oxygen is increased then power is lower. so operating costs are decided according to oxygen costs. On the other hand, high ozone concentration 2.0ppm, the necessary power is increased then amount of oxygen is lower. Therefore, in the case of G purification plant, the controlling factor of the input ozone concentration 2ppm, PID control operation by setting the concentration of over 10Wt% is efficient. The installed capacity is the more little the more better when considering on Ozone injection rate in the process of water treatment.

Costs analysis of carcass burial site construction: Focused on the foot and mouth disease 2011, South Korea

  • Kim, Mi Hyung;Ko, Chang-Ryong;Kim, Geonha
    • Environmental Engineering Research
    • /
    • 제20권4호
    • /
    • pp.356-362
    • /
    • 2015
  • Many burial sites were constructed in a short time to prevent the rapid spread of foot and mouth disease in infected livestock carcasses in Korea. More than 4,700 carcass burial sites were constructed in 2011. Approximately seven million poultry and 3.5 million livestock, including cattle and swine, were buried on farmland. Some burial sites were suspected of leachate leakage and were excavated and carcasses redisposed in a bioaugmentation process. This study performed interviews in order to understand the economic issues related to carcass burial and redisposal. The internal data from local government and the assumption data from online sites were analyzed to evaluate the costs; the focus was on burial site construction. The results showed that the local government paid $4.7 and $10.9 per carcass for traditional burial and redisposal. The comparable costs shown online were $4.5. This study found that the standard operating procedures should be carried out to reduce environmental impact and avoid additional costs. We estimated that the cost could be reduced by the advance preparations of materials against the emergency situations such as catastrophe of epidemics. In addition, the innovative technology for the stabilization of carcasses should be established through a future study.

Cost Analysis of the Structural Work of Green Frame

  • Joo, Jin-Kyu;Kim, Sun-Kuk;Lee, Goon-Jae;Lim, Chae-Yeon
    • 한국건축시공학회지
    • /
    • 제12권4호
    • /
    • pp.401-414
    • /
    • 2012
  • The adoption of Green Frame is expected to provide economic benefits, since construction costs are reduced by the in-situ production of precast concrete column and beam. The cost reduction can ultimately be realized by saving transportation costs and the overhead and profit of PC plants. The cost structure of Green Frame, which is built up using composite precast concrete members, is similar to that of a bearing-wall structure, but the difference in construction process has resulted in some cost differences for a few items. In particular, production and installation is the principal work involved in Green Frame made by precast concrete members, while form and concrete work is the principal work for a bearing-wall structure. As such, the rental time and fee for a tower crane should be compared through time analysis. To verify reliability, this study focused on developed residential projects to estimate the construction costs. Through this analysis, it was found that the costs of Green Frame were 1.57% lower than the costs of bearing-wall structure. The results of this study will help in the development of a management plan for the structural work of Green Frame.

A Decomposition Algorithm for a Local Access Telecommunication Network Design Problem

  • Cho, Geon
    • 한국경영과학회지
    • /
    • 제23권2호
    • /
    • pp.29-46
    • /
    • 1998
  • In this paper, we develop detailed algorithms for implementing the so-called Limited Column Generation procedure for Local Access Telecommunication Network(LATN) design problem. We formulate the problem into a tree-partitioning problem with an exponential number of variables. Its linear programming relaxation has all integral vertices, and can be solved by the Limited Column Generation procedure in just n pivots, where n is the number of nodes in the network. Prior to each pivot. an entering variable is selected by detecting the Locally Most Violated(LMV) reduced cost, which can be obtained by solving a subproblem in pseudo-polynomial time. A critical step in the Limited Column Generation is to find all the LMV reduced costs. As dual variables are updated at each pivot, the reduced costs have to be computed in an on-line fashion. An efficient implementation is developed to execute such a task so that the LATN design problem can be solved in O(n$^2$H), where H is the maximum concentrator capacity. Our computational experiments indicate that our algorithm delivers an outstanding performance. For instance, the LATN design problem with n=150 and H=1000 can be solved in approximately 67 seconds on a SUN SPARC 1000 workstation.

  • PDF