• Title/Summary/Keyword: Rectangular Core

Search Result 135, Processing Time 0.025 seconds

Large core polymeric single mode waveguide for passive fiber alignment (광섬유 수동정렬을 위한 단일 모드 대형 코어 폴리머 광도파로)

  • Cho, Su-Hong;Beak, Yu-Jin;Oh, Min-Choel
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.79-84
    • /
    • 2005
  • To increase the tolerance for passive fiber alignment, a single mode polymer waveguide with a large core structure is demonstrated. The large core waveguide is designed to have a mode profile comparable to that of a thermally expanded core (TEC) fiber, and it can be connected to a high-contrast waveguide through an adiabatic transition taper structure. From a waveguide with a rectangular core of 25 ${\times}$ 25 ${\mu}{\textrm}{m}$$^2$, a single mode propagation is observed when the index contrast is as low as 0.0005. A UV-cured injection molding method is used to fabricate the thick core structure. Due to the large mode size, the insertion loss of the device is below 0.5 dB until the lateral displacement of the TEC fiber is 4.5 ${\mu}{\textrm}{m}$. The low insertion loss is important for reproducible passive alignment.

Soft Switching of Half-Bridge Converter Using Saturable Core (포화자심을 이용한 하프브릿지 컨버터의 소프트스위칭에 관한 연구)

  • Kang , Chan-Ho;Kim , Hee-Jun;Harada, Koosuke;Sakamoto, Hiroshi
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.71-78
    • /
    • 2002
  • A method of soft switching in the half bridge converter using a small saturable core is presented. For the soft switching, a small dead time of both switch off is made in a pair of MOSFET switch. The saturable core is of rectangular magnetization characteristics and the core flux swings from the minus to the plus saturation during ON time of the switch. The soft switching is realized in dead time by a resonance between the saturating inductance of the core and the stray capacitance of MOSFET. As an extension of this concept, instead of the saturable core, we propose a new soft switching circuit using a linear inductance and two switches, which is especially suitable for regulating the output and also for high frequency switching. A theoretical principle of soft switching presented here was confirmed by experiments on a half bridge converter of 1.25 KW.

Review paper: Application of the Pulsed Eddy Current Technique to Inspect Pipelines of Nuclear Plants

  • Park, D.G.;Angani, C.S.;Kishore, M.B.;Vertesy, G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.342-347
    • /
    • 2013
  • Local wall thinning in pipelines affects the structural integrity of industries, such as nuclear power plants (NPPs). In the present study, a development of pulsed eddy current (PEC) technology that detects the wall thinning of pipelines covered with insulation is reviewed. The methods and experimental results, which have two kinds of probe with a single and double core, were compared. For this purpose, the single and double core probes having one and two excitation coils have been devised, and the differential probe with two Hall sensors has been fabricated to measure the wall thinning in insulated pipelines. The test sample is a stainless steel having different thickness, laminated by plastic insulation to simulate the pipelines in NPPs. The excitation coils in the probe is driven by a rectangular current pulse, the difference of two Hall sensors has been measured as a resultant PEC signal. The peak value of the detected signal is used to describe the wall thinning. The double core probe has better performance to detect the wall thinning covered with insulation; the single core probe can detect the wall thinning up to an insulation thickness of 18 mm, whereas the double probe can detect up to 25 mm. The results show that the double core PEC probe has the potential to detect the wall thinning in an insulated pipeline of the NPPs.

Scaling analysis of Core Flow Pattern in a Low-Aspect Ratio Rectangular Enclosure -( II ) End-Driven flow Regime- (종횡비가 낮은 직각형 밀폐용기 내의 코어흐름 형태에 관한 해석 -( II ) 운동력이 양단에 존재하는 경우-)

  • 이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.4
    • /
    • pp.375-384
    • /
    • 1984
  • 본 연구에서는 종횡비가 낮은 직사각형 밀폐용기 내에 Rayleigh수가 충분히 커서 흐름의 운동력이 용기 양단에 존재하는 경우에 PartⅠ에서 개발된 해석적인 모델 을 근거한 scaling analysis를 통해 그 내부 흐름 형태를 정성적으로 예측, 기존의 결 과와 비교, 검토하였다. 해석결과, Prandtl수에 따라 여러가지 내부 흐름 형태가 존 재할 수 있음이 밝혀졌으며 용기 내 뚜렷한 경계층 흐름이 존재하기 위한 필요조건도 아울러 얻어졌다.

Double rectangular spiral thin-film inductors implemented with NiFe magnetic cores for on-chip dc-dc converter applications (이중 나선형 NiFe 자성 박막인덕터를 이용한 원칩 DC-DC 컨버터)

  • Lee, Young-Ae;Kim, Sang-Gi;Do, Seung-Woo;Lee, Yong-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.71-71
    • /
    • 2009
  • This paper describes a simple, on-chip CMOS compatible the thin-film inductor applied for the dc-dc converters. A fully CMOS-compatible thin-film inductor with a bottom NiFe core is integrated with the DC-DC converter circuit on the same chip. By eliminating ineffective top magnetic layer, very simple process integration was achieved. Fabricated monolithic thin film inductor showed fairly high inductance of 2.2 ${\mu}H$ and Q factor of 11.2 at 5MHz. When the DC-DC converter operated at $V_{in}=3.3V$ and 5MHz frequency, it showed output voltage $V_{out}=8.0V$, and corresponding power efficiency was 85%.

  • PDF

Static and free vibration behavior of functionally graded sandwich plates using a simple higher order shear deformation theory

  • Zouatnia, Nafissa;Hadji, Lazreg
    • Advances in materials Research
    • /
    • v.8 no.4
    • /
    • pp.313-335
    • /
    • 2019
  • The objective of the present paper is to investigate the bending and free vibration behavior of functionally graded material (FGM) sandwich rectangular plates using an efficient and simple higher order shear deformation theory. Unlike other theories, there are only four unknown functions involved, as compared to five in other shear deformation theories. The most interesting feature of this theory is that it does not require the shear correction factor. Two common types of FGM sandwich plates are considered, namely, the sandwich with the FGM facesheet and the homogeneous core and the sandwich with the homogeneous facesheet and the FGM core. The equation of motion for the FGM sandwich plates is obtained based on Hamilton's principle. The closed form solutions are obtained by using the Navier technique. A static and free vibration frequency is given for different material properties. The accuracy of the present solutions is verified by comparing the obtained results with the existing solutions.

An Experimental Study on Electromagnets for Urban Transit Maglev Vehicle(VI) (도시형 자기부상열차 부상용 전자석에 대한 실험적 연구(VI))

  • Kim, Bong-Seop;Chung, Hyun-Kap;Yoo, Mun-Whan
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.40-42
    • /
    • 1998
  • The levitation magnets for the UTM-01(Urban Transit Maglev) take up a substential portion of the vehicle weight and vehicle cost. It is thus very important to reduce the weight of magnets by improving their performance and also reduce the cost of making them. A very extensive study was conducted to achieve above goals. Shape of the magnet core was varied and various core materials were tested. Also tested was the anodized sheet coil to replace the currently used rectangular shape Al coil. The study so far has improved the performance of the magnet substantially. The levitation force-to-magnet weight ratio has been improved from 6.8 to 9.2 as a result. This improvement reduced to magnet weight of the UTM-01 test vehicle by 900 kg.

  • PDF

An Analysis on Design Strategies for Building Conversion - Case Study on the G-Office Building in Japan - (용도전환 시설의 계획 특성에 관한 연구 - 일본 동경 G-오피스 빌딩의 사례를 중심으로 -)

  • Lee, Seung-Mi;Kang, In-Ho
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.290-294
    • /
    • 2008
  • Conversion of the building can be a core strategy to activate the urban regeneration. Especially in the decayed district, the conversion or retrofit of old building can be a core catalyst to stimulate the urban regeneration. Throughout the case study, a conversion from office to dwelling, there were figured out the design strategies to respond to spatial, functional requirements. The results are as follows ; 1) The main design strategy is to articulate the space by embedding the wall, mass in the rectangular space. 2) to respond to the small size of space, the flexible, movable wall system Is adopted. This gives the selectiveness to the use of space. 3) to secure the livability of interior space, the buffer zone, a terrace space, is fully utilized. This space acts as thermal buffer zone as well as a semi-interior space.

  • PDF

Transient dynamic analysis of sandwich beam subjected to thermal and pulse load

  • Layla M. Nassir;Mouayed H.Z. Al-Toki;Nadhim M. Faleh;Hussein Alwan Khudhair;Mamoon A.A. Al-Jaafari;Raad M. Fenjan
    • Steel and Composite Structures
    • /
    • v.51 no.1
    • /
    • pp.1-8
    • /
    • 2024
  • Transient dynamic behavior of a sandwich beam under thermal and impulsive loads has been researched in the context of higher-order beam theory. The impulse load of blast type has been enforced on the top exponent of the sandwich beam while it is in a thermal environment. The core of the sandwich beam is cellular with auxetic rectangular pattern, whereas the layers have been built with the incorporation of graphene oxide powder (GOP) and are micromechanically introduced through Halpin-Tsai formulization. Governing equations for the sandwich beam have been solved through inverse Laplace transform style for obtaining the dynamical deflections. The connection of beam deflections on temperature variability, GOP quantity, pulse load situation and core relative density has been surveyed in detail.

Flexural Behaviors of High Performance Hollow Core Slabs with Upper Strands (상부강선을 갖는 고성능 중공슬래브의 휨거동)

  • 김인규;박현석;유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.2
    • /
    • pp.156-163
    • /
    • 2002
  • Hollow core slabs generally have not been used for a bridge or a parking slab in Korea. In this study, high performance hollow core slabs, which have been the most thick one in domestic are re-designed and examined for practical use. Flexural tests were performed on four 315mm deep hollow core slabs to investigate adaptability for high vehicle live loadings and composite action with topping concrete. The precast slabs were pre-tensioned with ten strands of 1/2 inch diameter at the lower of slab and four strands of 1/2 inch diameter at the upper of slab, and cast with 80 mm deep topping concrete. Tested hollow core slabs showed ductile failure behaviors which were conformed to the current Ultimate Strength Design Method for a span of 10m up to the live load of 1,000 kgf/㎡. The rectangular md round shear cotters which were used for the composite action between precast and topping concrete, developed sufficient strengths because cracking, even micro had not been developed at the end of slabs up to the pure flexural tensile failure.