Abstract
Hollow core slabs generally have not been used for a bridge or a parking slab in Korea. In this study, high performance hollow core slabs, which have been the most thick one in domestic are re-designed and examined for practical use. Flexural tests were performed on four 315mm deep hollow core slabs to investigate adaptability for high vehicle live loadings and composite action with topping concrete. The precast slabs were pre-tensioned with ten strands of 1/2 inch diameter at the lower of slab and four strands of 1/2 inch diameter at the upper of slab, and cast with 80 mm deep topping concrete. Tested hollow core slabs showed ductile failure behaviors which were conformed to the current Ultimate Strength Design Method for a span of 10m up to the live load of 1,000 kgf/㎡. The rectangular md round shear cotters which were used for the composite action between precast and topping concrete, developed sufficient strengths because cracking, even micro had not been developed at the end of slabs up to the pure flexural tensile failure.
Keywords
high performance; hollow core slab; composite action; shear cotter; precast; upper strand;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Scott, Norman L., "Performance of Precast Prestressed Hollow Core Slab with Composite Concrete Topping," PCI JournaI, Vol.18, No.2, March-April 1973.
2 Tamon Ueda "Shear Strength of Precast Pre-stressed Hollow Slab with Concrete Topping," ACI Structural Journal, July-August 1991.
3 Nilson, Arthur H., "Design of Prestressed Concrete," John Wiley and Sons, New York, 1987.
4 PCI Design Handbook, Fifth Edition, Prestressed Concrete Institut, Chicago, Illinois, 1999.