• Title/Summary/Keyword: Recovery Temperature

Search Result 1,653, Processing Time 0.029 seconds

Effects of Electrostatic Discharge Stress on Current-Voltage and Reverse Recovery Time of Fast Power Diode

  • Bouangeune, Daoheung;Choi, Sang-Sik;Cho, Deok-Ho;Shim, Kyu-Hwan;Chang, Sung-Yong;Leem, See-Jong;Choi, Chel-Jong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.4
    • /
    • pp.495-502
    • /
    • 2014
  • Fast recovery diodes (FRDs) were developed using the $p^{{+}{+}}/n^-/n^{{+}{+}}$ epitaxial layers grown by low temperature epitaxy technology. We investigated the effect of electrostatic discharge (ESD) stresses on their electrical and switching properties using current-voltage (I-V) and reverse recovery time analyses. The FRDs presented a high breakdown voltage, >450 V, and a low reverse leakage current, < $10^{-9}$ A. From the temperature dependence of thermal activation energy, the reverse leakage current was dominated by thermal generation-recombination and diffusion, respectively, at low and high temperature regions. By virtue of the abrupt junction and the Pt drive-in for the controlling of carrier lifetime, the soft reverse recovery behavior could be obtained along with a well-controlled reverse recovery time of 21.12 ns. The FRDs exhibited excellent ESD robustness with negligible degradations in the I-V and the reverse recovery characteristics up to ${\pm}5.5$ kV of HBM and ${\pm}3.5$ kV of IEC61000-4-2 shocks. Likewise, transmission line pulse (TLP) analysis reveals that the FRDs can handle the maximum peak pulse current, $I_{pp,max}$, up to 30 A in the forward mode and down to - 24 A in the reverse mode. The robust ESD property can improve the long term reliability of various power applications such as automobile and switching mode power supply.

Effect of interface bonding strength on the recovery force of SMA reinforced polymer matrix smart composites (형상기억합금 선재가 삽입된 폴리머기지 능동복합재료의 회복력에 미치는 계면 접합강도의 영향)

  • 김희연;김경섭;홍순형
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.18-21
    • /
    • 2003
  • The effect of interface bonding strength on the recovery force of SMA wire reinforced polymer matrix composites was investigated by pullout test. Firstly, the recovery forces and transformation temperatures of various prestrained SMA wires were measured and 5% prestrained SMA wires were prepared for the reinforcements of composites. EPDM incorporated with 20vol% silicon carbide particles(SiCp) of 6, 12, $60{mutextrm{m}}$ size were used as matrix. Pullout test results showed that the interface bonding strength increased when the SiCp size decreased due to the increase of elastic modulus of matrix. Cyclic test of composites was performed through control of DC current at the constant displacement mode. The abrupt decrease of recovery force during cycle test at high current was occurred by thermal degradation of matrix. This was in good agreement with temperature related in the thermal degradation of matrix. The hysteresis of recovery force with respect to the temperature was compared between wire and composite and the hysterisis of composites was smaller than the wire due to less thermal conduction.

  • PDF

An Experimental Study on Thermoelectric Generator Performance for Waste Coolant Recovery Systems in Vehicles (자동차 냉각수 폐열회수 열전발전 시스템의 성능에 관한 연구)

  • Lee, Dae-Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.7
    • /
    • pp.329-334
    • /
    • 2014
  • This study indicated the possibility of energy regeneration from waste coolant heat, by using thermoelectric generation integrated with heat pipe. The internal combustion engine rejects more than 60% wasteful energy to the atmosphere by heat. The thermoelectric generator has recently been studied, to convert the energy from engine waste heat into electricity. For coolant waste heat recovery, a thermoelectric generator was investigated, to find out the possibility of vehicular application. Performance characteristics were conducted with various test conditions of coolant temperature, coolant mass flow rate, air temperature, and air velocity, with the thermoelectric generator installed either horizontally or vertically. Experimental results show that the electric power and conversion efficiency increases according to the temperature difference between the hot and cold side of the thermoelectric generator, and the coolant flow rate of the hot side heat exchanger. Performance improvement can be expected by optimizing the heat pipe design.

A Study on the Performance of Paper Heat Exchanger for Exhaust Heat Recovery (배기열 회수용 종이 열교환기의 성능에 관한 연구)

  • Yoo, Seong-Yeon;Chung, Min-Ho;Choi, Jae-Ho;Kwon, Hwa-Kil;Lee, Chun-Woo;Lee, Ki-Seong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.245-250
    • /
    • 2003
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. The purpose of this research is to find the performance of paper heat exchanger for exhaust heat recovery, which exchanges latent heat as well as sensible heat. Experimental apparatus comprises heat exchanger model, constant temperature and humidity chamber, fan and measurement systems for temperature, pressure and flow rate. Thermal performance and pressure loss of the paper heat exchanger are measured and compared at various air velocities and outdoor conditions. Experimental results show that paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air.

  • PDF

The Effect of Dynamic Strain Aging on the High Temperature Plastic Deformation Behaviour of Al-Mg Alloy (Al-Mg 합금의 고온 소성 변형 특성에 미치는 동적 변형 시효의 영향)

  • 이상용;이정환
    • Transactions of Materials Processing
    • /
    • v.5 no.4
    • /
    • pp.327-336
    • /
    • 1996
  • The effect of dynamic strain aging on high temperature deformation behaviour of the A-Mg alloy was investigated by strain rate change tests and stress relaxation tests between 20$0^{\circ}C$and 50$0^{\circ}C$. Yield point, short stress transient and periodic discontinuities on the stress-strain curve were considered as an evidence of the effect of dynamic strain aging. With this criterion two distinct strain rate-temperature regimes could be manifested. Dynamic strain aging was considered to be effective in the high temperature-low strain rate regime, whereas dynamic recovery was a dominant deformation mechanism in the low temperature-high strain rate regime. It was found that dynamic strain aging in the high temperature deformation was governed by the mechcanism of diffusion-controlled, viscous dislocation movement.

  • PDF

The study on the factors which improve skin barrier recovery (피부장벽회복에 영향을 미치는 인자에 관한 연구)

  • Cha, Jae-Hoon;Kim, Yoon-Bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.21 no.2
    • /
    • pp.39-45
    • /
    • 2008
  • Objective : Skin barrier protects skin against harmful environment. Its function includes antimicrobial barrier as well as physical barrier. But there are few studies about the factors which improve skin barrier recovery after injury. The aim of this study is to investigate the factors which improve skin barrier recovery. Method : Nine hairless mice was anesthetized by inhalation and we tape stripped them. We used thermometer to know temperature one day ago, before anesthesia, before tape stripping, and after tape stripping. Vapometer was used to know transepidermal water loss before tape stripping, after tape stripping. And we used doppler flowmeter to measure blood flow before tape stripping, after tape stripping. Result : After analyzed data, we concluded that temperature was lower after anesthesia than before anesthesia and after tape stripping than before tape stripping. We could know that transepidermal water loss was lower after tape stripping than before tape stripping and more blood flowed after tape stripping. Conclusion : In our study, it was observed that temperature, transepidermal water loss, blood flow changed after tape stripping. But we thought lowered temperature was pathologic situation, more blood flow was to recover after injury. In traditional korean medicine, cold(寒) and imbalance of blood flow(血行) don't only make many skin diseases, but cold(寒) also obstructs blood flow. So we need to study how to warm cold(寒) and improve blood flow.

  • PDF

Technology of Waste Heat Recovery Using Heat Pipe Heat Exchanger for Industrial Practice (중고온 히트파이프를 이용한 열회수기술에 관한 연구)

  • Lee Young-Soo;Kim Jong-Ryul;Chang Ki-Chang;Baik Young-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1044-1050
    • /
    • 2004
  • The present study has been conducted to develop a heat pipe heat exchanger for middle-high temperature ranged from 300 to $600^{\circ}C$. Heat transfer rate, overall heat transfer coefficient and temperature effectiveness were investigated using a heat pipe heat exchanger with Dowtherm A as working fluid. Theoretical analysis was also conducted, and the followings were obtained: (1) Heat exchange rate increased as waste gas temperature supplied to evaporator and frontal velocity in condenser increased, (2) Overall heat transfer coefficient increased by $3{\sim}7\%$ as frontal velocity in evaporator and condenser increased, (3) Temperature effectiveness was about $30\%$ in evaporator and was about $40\%$ in condenser, (4) Heat recovery rate was about $38\%$, (5) Pressure drop did not exceed $8\;mmH_{2}O$ under the running condition of $1{\sim}3Nm/s$, (6) Simulation results were corresponded with experimental results.

The Anaesthetic Effect of MS-222 for Longtooth Grouper, Epinephelus moara and the Hybrid Grouper, E. moara ♀ × E. lanceolatus ♂ (자바리(Epinephelus moara)와 대왕자바리(E. moara ♀ × E. lanceolatus ♂)에 대한 MS-222의 마취효과)

  • Park, Jong Yeon;Kim, Kang-Rae;Bang, In-Chul
    • Korean Journal of Ichthyology
    • /
    • v.31 no.4
    • /
    • pp.235-240
    • /
    • 2019
  • The anaesthetic effect of tricaine methanesulfonate (MS-222) concentrations and water temperatures for longtooth grouper (Epinephelus moara) and hybrid grouper (E. moara ♀ × E. lanceolatus ♂) were investigated. Anesthetic induction and recovery time were measured at 18, 22, 26 and 30℃ of Cwater temperature and 100, 150, 200 and 250 ppm of anesthetic concentrations. Anesthetic induction time tended to decrease with increasing concentration and water temperature. Recovery time was proportional to concentration, but inversely proportional to water temperature. However, there was no significant differences in recovery time at 22℃ or lower. The optimal anesthesia condition was 30℃ and 100 ppm, which was the shortest recovery time for longtooth grouper, and 150 ppm at 30℃ in the case of hybrid grouper because anesthetic time is significantly different with 100 ppm in spite of no significant differences with 100 ppm for recovery time. As a results of two-way ANOVA test, there was a significant difference between the species of longtooth and hybrid grouper. On the other hand, there was no interaction effect between concentration and species. Also, there was no interaction effect among species, concentration, and water temperature.

Effect of Cu Content and Annealing Temperature on the Shape Memory Effect of NiTi-based Alloy (구리함량과 어닐링 온도가 NiTi 합금의 형상기억효과에 미치는 영향)

  • Hyeok-Jin Yang;Hyeong Ju Mun;Ye-Seul Cho;Jun-Hong Park;Hyun-Jun Youn;In-Chul Choi;Myung-Hoon Oh
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.37 no.2
    • /
    • pp.79-85
    • /
    • 2024
  • The effects of annealing heat treatment and the addition of Cu element on the shape memory effect of the NiTi-based alloy were investigated by analyzing differential scanning calorimeter results and characterizing recovery rate through 3D scanning after Vickers hardness test. Through 3D scanning of impressions after Vickers hardness test, the strain recovery rates for specimens without annealing treatment and annealed specimens at 400, 450, and 500℃ were measured as 45.96%, 46.76%, 52.37%, and 43.57%, respectively. This is because as the annealing temperature increases, both B19' and NiTi2 phases, which can impede martensitic transformation, are incorporated within the NiTi matrix. Particularly, additional phase transformation from R-phase to B19' observed in specimens annealed at 400 and 450℃ significantly contributes to the improvement in strain recovery rates. Additionally, the results regarding the Cu element content indicate that when the total content of Ni and Cu is below 49.6 at.%, the precipitation of fine B19' and NiTi2 phases within the matrix can greatly influence the transformation enthalpy and temperature range, resulting in relatively lower strain recovery rates in NiTi alloys with a small amount of Cu element produced in this study.

The Effect of Warming Intravenous Fluids on Body Temperature Change under a General Anesthesia, Shivering, and Recovery (수액가온요법이 전신마취 하 체온변화와 전율 및 회복에 미치는 영향)

  • Han, Hyo Jeong;Jeong, So Ra;Lee, Seong Hee;Choe, Gyeong Ran;Cha, Na Jeong;Sin, Yu Ri
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.1
    • /
    • pp.71-82
    • /
    • 2010
  • Purpose: The study was aimed to investigate the effects of warm fluid used during surgery on the patients' hypothermia prophylaxis and recovery after surgery. Methods: This data were collected from Jul. 13 to Nov. 31. 2009 at S hospital in M City. 60 patients who met the selection criteria were recruited in the study and divided into two groups. The warmed fluids were used for 30 patients in the experimental group, and the fluids in room air temperature were used for the others in the control group. Collected data were statistically analyzed using SPSS/win 18.0. Results: The body temperatures of the control group were significantly lower during surgery than those of the experimental group (p<.001). Shivering was significantly less occurred in the experimental group than the control group (p=.018). The experimental group used warmed fluids recovered faster than the control group. Conclusion: Warming fluid for the patients with general anesthesia was revealed to be effective in decreasing hypothermia during surgery, reducing shivering, helping recovery from the anesthesia. Further research is warranted to refine and apply this evidence in nursing practice.