• 제목/요약/키워드: Reconstruction plate

검색결과 186건 처리시간 0.03초

Reconstruction plates used in the surgery for mandibular discontinuity defect

  • Seol, Guk-Jin;Jeon, Eun-Gyu;Lee, Jong-Sung;Choi, So-Young;Kim, Jin-Wook;Kwon, Tae-Geon;Paeng, Jun-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권6호
    • /
    • pp.266-271
    • /
    • 2014
  • Objectives: The purpose of this study was to analyze the survival rate of reconstruction plates that were used to correct mandibular discontinuity defects. Materials and Methods: We analyzed clinical and radiological data of 36 patients. Only discontinuous mandibular defect cases were included in the study. Reconstruction plate survival rate was analyzed according to age, gender, location of defect, defect size, and whether the patient underwent a bone graft procedure, coronoidectomy, and/or postoperative radiation therapy (RT). Results: Plate-related complications developed in 8 patients, 7 of which underwent plate removal. No significant differences were found in plate survival rate according to age, gender, location of defect, defect size, or whether a bone graft procedure was performed. However, there were differences in the plate survival rate that depended on whether the patient underwent coronoidectomy or postoperative RT. In the early stages ($9.25{\pm}5.10months$), plate fracture was the most common complication, but in the later stages ($35.75{\pm}17.00months$), screw loosening was the most common complication. Conclusion: It is important to establish the time-related risk of complications such as plate fracture or screw loosening. Coronoidectomy should be considered in most cases to prevent complications. Postoperative RT can affect the survival rate and hazard rate after a reconstruction plate is fitted.

터어키안 저부 재건술시 실리콘 판의 유용성 (Usefulness of Silicone Plate for Sellar Floor Reconstruction)

  • 김승범;김재민;이형중;백광흠;김충현;오석전;이승환
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권9호
    • /
    • pp.1204-1208
    • /
    • 2000
  • Objectives : At the closure of the transsphenoidal approach(TSA), the proper sellar floor reconstruction plays an important role in preventing postoperative complications. The septal cartilage, perpendicular plate of nasal septum, and the sphenoid sinus bone are usually used to repair the sellar floor as a bone splint. The authors evaluate the usefulness of a silicone plate as a substitute for bone splint to close a defect of the sellar floor. Materials and Methods : A silicone plate was used to repair the sellar floor in 7 patients with sellar lesions which included four pituitary adenomas, two Rathke's cleft cysts and one metastatic tumor. Among seven cases, five cases underwent a standard TSAs and two received a extended TSAs. The trajectories of the approach were sublabial in four cases and endonasal routes in three cases. The silicone plate for implantation was cut to a size of slightly larger than that of bone window and inserted with a three-pronged fork, and then adjusted precisely. Results : In six patients, there were no complications which related to sellar floor reconstruction. A postoperative cerebrospinal fluid(CSF) rhinorrhea was observed in one patient with pituitary macroadenoma. Conclusions : From the authors' experience, the advantages of the silicone plate are its simplicity of molding to fit any size of sellar floor defects, and easy detection of previously created bone window at reoperation.

  • PDF

The effect of fixation plate use on bone healing during the reconstruction of mandibular defects

  • Hong, Khang Do Gia;Kim, Seong-Gon;Park, Young-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권5호
    • /
    • pp.276-284
    • /
    • 2019
  • Objectives: This study sought to compare efficiency results between the use of a customized implant (CI) and a reconstruction plate (RP) in mandibular defect reconstruction in an animal model. Materials and Methods: Fifteen rabbits underwent surgery to create a defect in the right side of the mandible and were randomly divided into two groups. For reconstruction of the mandibular defect, the RP group (n=5) received five-hole mini-plates without bone grafting and the CI group (n=10) received fabricated CIs based on the cone-beam computed tomography (CBCT) data taken preoperatively. The CI group was further divided into two subgroups depending on the time of CBCT performance preoperatively, as follows: a six-week CI (6WCI) group (n=5) and a one-week CI (1WCI) group (n=5). Daily food intake amount (DFIA) was measured to assess the recovery rate. Radiographic images were acquired to evaluate screw quantity. CBCT and histological examination were performed in the CI subgroup after sacrifice. Results: The 1WCI group showed the highest value in peak average recovery rate and the fastest average recovery rate. In terms of reaching a 50% recovery rate, the 1WCI group required the least number of days as compared with the other groups ($2.6{\pm}1.3days$), while the RP group required the least number of days to reach an 80% recovery rate ($7.8{\pm}2.2days$). The 1WCI group showed the highest percentage of intact screws (94.3%). New bone formation was observed in the CI group during histological examination. Conclusion: Rabbits with mandibular defects treated with CI showed higher and faster recovery rates and more favorable screw status as compared with those treated with a five-hole mini-plate without bone graft.

Bayesian Tomographic 재구성에 있어서 Gibbs Smoothing Priors의 효과에 대한 비교연구 (A Comparative Study of the Effects of Gibbs Smoothing Priors in Bayesian Tomographic Reconstruction)

  • 이수진
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.279-282
    • /
    • 1997
  • Bayesian reconstruction methods for emission computed tomography have been a topic of interest in recent years, partly because they allow for the introduction of prior information into the reconstruction problem. Early formulations incorporated priors that imposed simple spatial smoothness constraints on the underlying object using Gibbs priors in the form of four-nearest or eight-nearest neighbors. While these types of priors, known as "membrane" priors, are useful as stabilizers in otherwise unstable ML-EM reconstructions, more sophisticated prior models are needed to model underlying source distributions more accurately. In this work, we investigate whether the "thin plate" model has advantages over the simple Gibbs smoothing priors mentioned above. To test and compare quantitative performance of the reconstruction algorithms, we use Monte Carlo noise trials and calculate bias and variance images of reconstruction estimates. The conclusion is that the thin plate prior outperforms the membrane prior in terms of bias and variance.

  • PDF

Condyle dislocation following mandibular reconstruction using a fibula free flap: complication cases

  • Kang, Sang-Hoon;Lee, Sanghoon;Nam, Woong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.14.1-14.10
    • /
    • 2019
  • Background: Condylar dislocation can arise as a complication in patients who required mandibular and/or condylar reconstruction and were operated on with fibula free flap (FFF) using surgical guides designed using simulation surgery. Surgeons should be aware of the complications in these present cases when planning and performing reconstructions as well as predicting prognoses. Cases presentation: Two cases showed condylar dislocation in mandibular reconstruction using a FFF fixed with a reconstruction plate. Three cases showed condylar dislocation in mandibular reconstruction using a fibula free flap fixed with a mini-plate. Conclusion: Despite the lack of clinical symptoms in these cases following mandibular reconstruction using an FFF, the mandibular condyle was severely displaced away from the glenoid fossa. A surgeon must have sufficient time to consider the use of a long flap with thickness similar to that of the mandible, ways to minimize span and bending, and methods of fixation. The patient, moreover, should be educated on condylar dislocation. Customized CAD/CAM-prototyped temporomandibular condyle-connected plates may be a good alternative even if virtual simulation surgery is to be performed before surgery. These considerations may help reduce the incidence of complications after mandibular reconstruction.

성인 쇄골 간부 골절의 수술적 치료-골수강내 다발성 Steinmann핀 고정술과 재구성 금속판 고정술과의 비교- (Operative Treatment of the Clavicular Midshaft Fractures in Adult - A Comparison between Intramedullary Multiple Steinmann Pins Fixation and Reconstruction Plate Fixation -)

  • 이영국;구혜서
    • Clinics in Shoulder and Elbow
    • /
    • 제2권1호
    • /
    • pp.14-20
    • /
    • 1999
  • Purpose: Despite of the popular use of the reconstruction plate for the fixation of clavicular shaft fractures, some disadventages have been raised such as long period of immobilization, long skin incision, loosening of plate and screws, and increased chance of nonunion due to severe periosteal injury. Thus, the authors have performed intramedullary multiple Steinmann pins fixation that could reduce the disadvantages of plate fixation in order to compare the treatment results between the two groups. Materials & Methods: From 1994. Jan. to 1997. Dec. the department of orthopaedic surgery of the Kwak's hospital treated operatively for 56 cases of the clavicular shaft fractures in adult. 39 cases of them were treated with the plate fixation and 17 cases with the intramedullary multiple Steinmann pins fixation(SP group). Reconstruction plates(Plate group) were used for 26 out of 39 patients treated with plate fixation. Among the Plate group and SP group, each 15 cases were selected by age and sex and compared each other according to the bone union time, union rate, complication, and functional results. The follow-up period was 12 months at the shortest and 48 months at the longest and the average was 16 months. Results: The Plate group showed that the bone union time was 7 weeks and the bone union rate was 93%. The SP group showed 6.5 weeks and 100% respectively. In complication, the Plate group had 1 case of loosening of plate and screws and delayed union; SP group had 1 case of pin migration. The functional results according to Kang's criteria, 87% of the Plate group and 93% of the SP group showed good or excellent. Conclusion : The SP group showed very comparable results in terms of the bone union time, bone union rate, complication, and functional results comparing to the Plate group. The intramedullary multiple Steinmann pins fixation showed several advantages over the reconstruction plate fixation, which were simple operative technique, easy removal of pins, being able to perform immediate postoperative full range of motion exercise. Therefore, the intramedullary multiple Steinmann pins fixation is thought to be one of the useful operative techniques in treatment of the clavicular shaft fractures in adult.

  • PDF

Preliminary Surgical Result of Cervical Spine Reconstruction with a Dynamic Plate and Titanium Mesh Cage

  • Chung, Dae-Yeong;Cho, Dae-Chul;Lee, Sun-Ho;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권2호
    • /
    • pp.111-117
    • /
    • 2007
  • Objective : The objective of this study was to validate the effects of a titanium mesh cage and dynamic plating in anterior cervical stabilization after corpectomy. Methods : A retrospective study was performed on 31 consecutive patients, who underwent anterior cervical reconstruction with a titanium mesh cage and dynamic plating, from March 2004 to February 2006. Twenty-four patients had 1-level and 7 had 2-level corpectomies. Ten patients underwent surgery with a cage of 10-mm diameter and 21 with 13-mm diameter. Neurological status and outcomes were assessed according to Odom's criteria. Sagittal angle, coronal angle, settling ratio, sagittal displacement, and cervical lordosis were used to evaluate the radiological outcomes. Results : In overall, 26 [83.9%] of 31 showed excellent or good outcomes. Thirteen percent [4 cases] of the patients developed surgical complications, such as hoarseness, transient dysphagia, or nerve root palsy. Seven [22.6%] patients had reconstruction failure:5 [20.8%] in the 1-level corpectomy group and 2 [28.5%] in the 2-level corpectomy group. Revisions were required in 2 patients with plate pullout due to significant instability. However, none of 5 patients who demonstrated cage displacement or screw pullout, underwent a revision. Radiographs revealed bony consolidation in 96.3% of the patients, including 6 patients with implantation failure during the follow-up period. Conclusion : Based on our preliminary results, the titanium mesh cage and dynamic plating was effective for cervical reconstruction after corpectomy. The anterior cervical reconstruction performed with dynamic plates is considered to reduce stress shielding and greater graft compression that is afforded by the unique plate design.

Maxillary reconstruction using tunneling flap technique with 3D custom-made titanium mesh plate and particulate cancellous bone and marrow graft: a case report

  • Takano, Masayuki;Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Homma, Shinya;Abe, Shinichi;Katakura, Akira;Shibahara, Takahiko
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.43.1-43.5
    • /
    • 2019
  • Background: Reconstructive surgery is often required for tumors of the oral and maxillofacial region, irrespective of whether they are benign or malignant, the area involved, and the tumor size. Recently, three-dimensional (3D) models are increasingly used in reconstructive surgery. However, these models have rarely been adapted for the fabrication of custom-made reconstruction materials. In this report, we present a case of maxillary reconstruction using a laboratory-engineered, custom-made mesh plate from a 3D model. Case presentation: The patient was a 56-year-old female, who had undergone maxillary resection in 2011 for intraoral squamous cell carcinoma that presented as a swelling of the anterior maxillary gingiva. Five years later, there was no recurrence of the malignant tumor and a maxillary reconstruction was planned. Computed tomography (CT) revealed a large bony defect in the dental-alveolar area of the anterior maxilla. Using the CT data, a 3D model of the maxilla was prepared, and the site of reconstruction determined. A custom-made mesh plate was fabricated using the 3D model (Okada Medical Supply, Tokyo, Japan). We performed the reconstruction using the custom-made titanium mesh plate and the particulate cancellous bone and marrow graft from her iliac bone. We employed the tunneling flap technique without alveolar crest incision, to prevent surgical wound dehiscence, mesh exposure, and alveolar bone loss. Ten months later, three dental implants were inserted in the graft. Before the final crown setting, we performed a gingivoplasty with palate mucosal graft. The patient has expressed total satisfaction with both the functional and esthetic outcomes of the procedure. Conclusion: We have successfully performed a maxillary and dental reconstruction using a custom-made, pre-bent titanium mesh plate.