• Title/Summary/Keyword: Reclamation Layer

Search Result 61, Processing Time 0.027 seconds

A Numerical Analysis of Regional Atmospheric Circulation with Large Scale Reclamation of Coastal Region (대규모 해안매립에 따른 기상장 변동의 수치해석)

  • 이성대
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.3
    • /
    • pp.46-54
    • /
    • 2000
  • Three dimensional numerical experiments that included the land-use transformation by the large scale reclamation were used to investigate the mesoscale air flow over the coastal regions. In this paper the surface temperature of the inland was determined through the surface heat budget consideration with inclusion of a layer of vegetation. The vertical diffusion coefficients of momentum, heat and specific humidity in the constant flux layer were taken from the Mellor and Yamada(1975). It has shown that the resulting model is able to reproduce the air circulation in coastal regions, and the simulated characteristics agree with the known properties of this circulation. A series of numerical experiments were then carried out to investigate the diurnal response of the air flow to various types of surface inhomogeneities.

  • PDF

Transfer of Arsenic from Paddy Soils to Rice Plant under Different Cover Soil Thickness in Soil Amendments in Abandoned Coal Mine (폐탄광지역 비소오염 농경지(논) 개량 시 복토두께에 따른 비소의 벼 전이 및 토양용액 특성)

  • Koh, Il-Ha;Kwon, Yo Seb;Jeong, Mun-Ho;Ko, Ju In;Bak, Gwan-In;Ji, Won Hyun
    • Economic and Environmental Geology
    • /
    • v.54 no.4
    • /
    • pp.483-494
    • /
    • 2021
  • This study was carried out to investigate the feasibility of reducing clean cover soil using a flooded column test in arsenic-contaminated farmland reclamation of abandoned coal mine area that shows generally low or about worrisome level (25 mg/kg) of Korea soil environment conservation act unlike abandoned metal mine. During the monitoring period of soil solution for 4 months, chemical properties (pH, EC, ORP, Fe, Mn, Ca, and As) in each layer (clean soil cover and contaminated/stabilized soil) showed different variation. This result revealed that soil solution in stabilized or contaminated soil rarely affected that in cover soil. Whether stabilized or not, arsenic concentrations in the rice roots grown in the soil covers with the thickness of 40 cm decreased by 98% in compared with the that grown in the control soil. In case of the soil covers with 20 cm thickness on stabilized soil, it decreased by 80% and this was 22 percentage point higher than when the soil of lower layer was not stabilized. Thus, reducing clean cover soil could be possible in contaminated farmland soil reclamation if appropriate stabilization of contaminated soil is carried.

Residual Settlement for Dredged Soil Deposit Considering Stress History in Incheon Area (인천지역 준설토의 응력이력을 고려한 잔류 침하량)

  • Chun, Byungsik;Lee, Inhoon;Park, Dukhyum;Sung, Hwadon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.2
    • /
    • pp.5-13
    • /
    • 2008
  • To identify the reclamation history formed by top dredged soil reclamation layer over the original ground, various field tests and laboratory tests were conducted. Especially when the original ground was not completely consolidated, CPTu test was carried out to calculate rational settlement due to the banking load. CPTu test results showed that the degree of consolidation of weak clay ground by dredged reclamation was on average 80%. As the research area was not completely consolidated by dredged reclamation in the past, the consolidation settlement should account for the residual settlement (20%) in the case of additional banking load. When the degree of consolidation of the original ground was not taken into account, the residual consolidation was expected in excessive settlement (up to 20%) and in such case PBD (Plastic Board Drain) was not effective in obtaining desired degree of consolidation.

  • PDF

A study of seasonal variation of the residual flow before and after Saemangeum reclamation (새만금간척전후의 잔차류의 계절변화에 관한연구(농지조성 및 농어촌정비))

  • 신문섭
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.47-53
    • /
    • 2000
  • Saemangeum coastal area is being constructed the 33km sea dike and 40,000ha reclamation area. The purpose of this study is to find the residual circulations in spring before and after the dike construction by a robust diagnostic and prognostic numerical model. Heat flux at the sea surface in May was adopted on the basis of the daily inflow of solar radiation at the earth surface, assuming an average atmospheric transmission and no clouds, as a function of latitude and time of year(George L.P.,J. E. William,1990). The discharge from the Geum, the Mankyung and the Dongjin rivers was adopted on the basis of experience formula of river flow in May(The M. of C.,Korea, 1993). Water temperature and salinity along the open boundaries are obtained from the results of field observations. The results of spring of the residual flow in the Saemangeum coastal area by a prognostic numerical model lead to the following conclusions: Water temperature in spring is the highest, salinity is the lowest and density is the lowest at the upper layer near the coast after the dike construction. The flow pattern at the upper layer during spring is anti-clockwise circulation between Wi and Shinsi islands. The flow pattern at the lower layer is clockwise circulation between Wi and Shinsi islands.

  • PDF

Analysis of Environmental Hazard by the Leachate from Disposal Waste (매립장 침출수 환경 재해에 관한 연구)

  • Kim, Jun-Kyoung;Bae, Hyo-Jun;Choi, Oh-Soon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.4 s.11
    • /
    • pp.145-151
    • /
    • 2003
  • The domestic and the industry wastes which mainly come out of human life activities have been usually processed mainly by the incineration method and/or the method of reclamation. The method of reclamation, specially open dumping, has caused significant environmental pollution problems on the local or regional soil and groundwater system by leachate. Therefore, to investigate the 3-D structure characteristics of environmental pollution area is one of the hot subjects. We applied dipole-dipole method of electrical resistivity survey to investigate 3-D environmental contamination characteristics of the Noeun landfill area. For electrical resistivity survey, the line for measurements was established parallel to the main boundary of the Noeun landfill, for effective investigation of the whole landfill area. The result shows that the uppermost layer of the Noeun landfill is believed to be stabilized completely, based on the result of electrical resistivity values. However, the lowest layer of the Noeun landfill was partially polluted by leachate. Therefore, the electrical resistivity survey method is believed to be the one of the most effective methods to investigate three-dimensional distribution of leachate occurred in the lower part of landfill area.

A Study on the layer construction for vegetation using industrial wastes (산업폐기물을 활용한 식생기반 조성에 관한 연구)

  • Yu, Chan;Yang, Ki-Suk;Ryu, Si-Chang;Cho, Byung-Jin;Ahn, Byung-Kwan
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.219-222
    • /
    • 2003
  • Bech scale tests were performed to evaluate the adaptability of industrial wastes, especially bottom ash, salg and phosphogypsum among others, for constructing the surface layer of a landfill or reclamation, which function is a vegetation base layer. In the test, columes test were used to check the extraction characteristics of wastes and small PVC soil-box that equipped the drainage device was used to model a performance of layers and to monitor the growth of plants at the composite layer of those. Tests have been continued during one and half year and It has been verified that bottom ash and phosphogypsum look like as a valuable material to safely reuse as the vegetation base layer even though some unconfined factors are remain.

  • PDF

Geotechnical Variability Characterization of Songdo area in Incheon by Field Tests (현장시험을 이용한 인천 송도지반의 변동성 분석)

  • Kim, Dong-Hee;Bae, Kyung-Doo;Lee, Ju-Hyung;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1435-1440
    • /
    • 2009
  • Geotechnical variability is a complex feature that results from many independent sources of uncertainties, and is mainly affected by inherent variability and measurement errors. This study evaluates the coefficient of variation (COV) of soil properties at Song-do region in Korea for evaluating inherent soil variability. Since soil variability is sensitive to soil layers and soil types, the COVs by soil layers (reclaimed layer and marine layer) and the COVs by soil types (clay and silt) were separately evaluated. It is observed that geotechnical variability of marine layer and clay is relatively smaller than that of reclamation layer and silt.

  • PDF

Consolidation Characteristics of Songdo Area in Incheon (인천 송도지역 지반의 압밀특성)

  • Kim, Dong-Hee;Hong, Sung-Jin;Lee, Woo-Jin;Ko, Seong-Kwon
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.1
    • /
    • pp.21-33
    • /
    • 2010
  • In this paper, the consolidation and the permeability characteristics of Songdo were evaluated based on the laboratory and field tests. The test results indicate that silty clay layer above approximately E.L-15 m are consolidation layer, and sand layers embedded in consolidation layers are drainage layers. Consolidation layer was overconsolidated state before the reclamation work; however, it transferred to normalized state after the reclamation work. In addition, the average and the range of consolidation properties and magnitude of anisotropy of coefficient of consolidation were evaluated according to the soil types such as clay, silty, and clayey silt since these properties are sensitive to soil types. These analysis results can be used as preliminary design parameters of consolidation and permeability m Songdo area.

Depositional Characteristics of Busan Clay, Effects of Artesian Pressure, and Experiences from Ground Improvement (부산 점토의 퇴적 특성, 피압의 영향 및 지반 개량에서 얻은 경험)

  • Kim, Sang-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.3-38
    • /
    • 2007
  • The depositional characteristics of Busan clay are initially described in this paper. The deposits of the Nakdong River estuary are composed of some different layers, which have been affected by marine transgression and regression. The upper clay layer is thick and soft. The lower clay layer and some depth of the upper clay layer have been leached by artesian pressure existing in an aquifer below. The clay shows unique physical and engineering characteristics due to leaching. Several large-scale reclamation projects have been performed in this delta area. The preloading method using long vertical drains has been applied for soft ground improvement. Experiences obtained from ground improvement are mentioned in connection with the depositional characteristics of the clay layers.

  • PDF

Study on the Rational Construction Method Using Analysis of the Case Study of PHC Pile Foundation in Song-Do Area (송도지역 내 PHC 말뚝기초 적용사례분석을 통한 적정 시공방법 연구)

  • Lee, Byengho;Lee, Jonghwi;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.3
    • /
    • pp.55-61
    • /
    • 2011
  • Song-Do international city is the area developed in large-scale land reclamation. Song-Do area consists of reclamation layer, sedimentary layer(loose silt, soft clay and sand alternating) and residual layer from the ground surface. Therefore, using pile foundation is inevitable to build structures safely. In this area, driven PHC piles have been generally constructed in terms of environmental and economic conditions. As a result of analyzing 4 sites in Song-Do district 5 and 7 recently, the method of driving pile has many problems because of existence of rigid soil in sedimentary layer and installation of more than 30m piles. In this case, when installing piles by drive after pre-boring up to appropriate depth, the results of constructability analysis were very good. And in the economic efficiency, although 4% of construction cost rose, it was a very slight increase in comparison with improvement of workability. In the case of the stability, more than 70% compared to the allowable stress of piles was satisfied through the load test. As a result, when PHC piles is installed in Song-Do district, the proper construction method is that piles are located at bearing layer after boring rigid sand layer.