• Title/Summary/Keyword: Reclaimed marine foundation

Search Result 8, Processing Time 0.029 seconds

Foundation Design the 151 story Incheon Tower in Reclamation Area

  • Abdelrazaq, Ahmad;Badelow, Frances;Kim, Sung-Ho;Park, Yung-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.157-171
    • /
    • 2009
  • A 151 storey super high-rise building located in an area of reclaimed land constructed over soft marine clay in Songdo, Korea is currently under design. This paper describes the design process of the foundation system of the supertall tower, which is required to support the large building vertical and lateral loads and to restrain the horizontal displacement due to wind and seismic forces. The behaviour of the foundation system due to these loads and foundation stiffness influence the design of the building super structure, displacement of the tower, as well as the raft foundation design. Therefore, the design takes in account the interactions between soil, foundation and super structure, so as to achieve a safe and efficient building performance. The site lies entirely within an area of reclamation underlain by up to 20m of soft to firm marine silty clay, which overlies residual soil and a profile of weathered rock. The nature of the foundation rock materials are highly complex and are interpreted as possible roof pendant metamorphic rocks, which within about 50m from the surface have been affected by weathering which has reduced their strength. The presence of closely spaced joints, sheared and crushed zones within the rock has resulted in deeper areas of weathering of over 80m present within the building footprint. The foundation design process described includes the initial stages of geotechnical site characterization using the results of investigation boreholes and geotechnical parameter selection, and a series of detailed two- and three-dimensional numerical analysis for the Tower foundation comprising over 172 bored piles of varying length. The effect of the overall foundation stiffness and rotation under wind and seismic load is also discussed since the foundation rotation has a direct impact on the overall displacement of the tower.

  • PDF

Reinforcement Effect of Marine Structure Foundation by Column Jet Method (CJM 그라우팅에 의한 호안구조물의 기초보강효과)

  • 천병식;양형칠
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.128-131
    • /
    • 2001
  • The purpose of this study is to investigate the application of Column Jet Method(CJM) as countermeasure against settlement and slope sliding of existing marine structure due to embankment load behind reclaimed revetment. CJM is to make high-strengthened body by compacting and grouting cement mortar after forming artificial space in the ground with ground relaxition machine or high pressure water jetting. Before the ground was reinforced by CJM, the result of slope stability analysis was not satisfy the allowable safe ratio, but after the ground was reinforced by CJM, the stability of slope was over the allowable safe ratio and stable, Therefor, the application of CJM to restraint settlement and sliding of marine structure was very satisfactory.

  • PDF

Quantitative assessment of reclamation-dams from the sea by using combined seismic methods (해안 매립지 탄성파 탐사)

  • Kim Jung-Yul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.85-100
    • /
    • 2002
  • This paper deals with a development of combined seismic methods, based on the application of Televiewer and seismic tomography, for the quantitative assessment of reclaimed body or dam at seashores in our county. The underground structure of reclaimed dam is very complex, mainly due to the unexpected exchange of rock fragments with the marine silty mud in conjunction with S.C.P. (Sand Compaction Pile) foundation, so that for several reasons only the use of Televiewer and seismic tomography for general application might not lead to a desirable resolution. Kinds of upgraded measuring and evaluation techniques for that are needed. For examples, a novel strategy for capturing the returning impulses from the outer side of casing plastic pipe is desired to be developed. For the tomograhy, one should be being more focussed on the study of raw data based on the wave propagation theory. In this paper, it is shown that such multidisciplinary approaches can be, by attempting to compare and jointly interpret the results from two methods, much efficient for understanding the reclaimed dam structure.

  • PDF

Demonstration of Developed Numerical Procedure to Describe 3-dimensional Long-term Behavior of the Pleistocene Marine Foundations (Pleistocene 해저지반의 3차원 장기거동 해석을 위해 개발한 수치해석 기법의 입증)

  • Yun, Seong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.7
    • /
    • pp.5-14
    • /
    • 2020
  • Kansai International Airport (KIX) was opened in September 1994. Although 26 years have passed since the completion of the first island, long-term settlement is still in progress. This settlement occurs in the Pleistocene layer. For it is not easy to determine the permeability of the Pleistocene sand layer because the thickness and the degree of fine content in the horizontal direction are constantly changing. In addition, it is also a difficult to predict the interactive behavior of the ground due to the construction of the second phase island adjacent to it. In order to solve this problem, a two-dimensional finite element analysis considering elasto-viscoplastic was performed to evaluate the long-term deformation, including the interactive behavior of the alternating Pleistocene foundation due to the construction of two adjacent reclaimed islands. In general, two-dimensional analysis can be used when a section can represent the entire sections. However, Kansai Airport is an artificial reclaimed island so two-dimensional analysis cannot solve the problem such as the stress deformation in the corners of the island. Additionally, the structure of the actual sub-ground through physical exploration is non-homogeneity and its thickness is also not constant. Therefore, there are limitations for the two-dimensional analysis to explain the phenomena. That is, three-dimensional analysis is strongly required. Due to these demands, the author extended the existing two-dimensional program capable of elasto-viscoplastic analysis to three-dimensional and completed the verification of the three-dimensional program developed through one-dimensional consolidation analysis. In order to demonstrate the validity of the developed 3D program that has been verified, an analysis is performed under the same analysis conditions as the existing research using a two-dimensional program. The effectiveness of the developed 3D numerical analysis program was demonstrated by comparing the analysis results with the 2D results and actual measurement data.

A Case Study of a Foundation Design and Construction of a High-rise Building Applying Bi-directional Pile Load Test(BD PLT) (양방향 말뚝재하시험(BD PLT)을 적용한 초고층 건축구조물의 기초설계 및 시공사례)

  • Kim, Sung-Ho;Lee, Min-Hee;Hwang, Geun-Bae;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.539-550
    • /
    • 2006
  • New Songdo city is currently developing on the reclaimed land on a marine deposit and among the development the four sixty-four(64) stories high rise buildings are under construction at block 125. The ground condition of the site is comprised of a deep seated weathered rock staratum under a soft marine deposit layer. As a foundation system, a bored pile was planned to transmit the applied load to the stable layer. In this study, the behavior of the weathered rock especially locating at a upper part having a weak strength(HWR, MWR) has been evaluated through series of hi-directional pile load test(BD PLT) carried out on the 3 drilled shafts socketed in a weathered rock layer in a design stage. It has been planned to increase the effect of the tests that the length of test piles was prepared short enough to perform the test under a high stress. The summary of the design reflecting the test results has been made up. In addition, the 4 hi-directional pile tests excuted on the working piles during the construction stage for the purpose of confirmation and the evaluation of the adequacy of the pile behaviors have been included in this study.

  • PDF

Reclamation and Soil Improvement on Ultra Soft Soil (I) - Reclamation (초연약지반의 매립 및 지반개량 사례 연구 (I) - 매립)

  • Na, Yung-Mook;Hong, Eui;Han, Jung-Soo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.1
    • /
    • pp.23-31
    • /
    • 2005
  • The "Silt Pond" is 180 hectares in size and contained ultra soft slurry-like soil varying between 3 to 20 meters in thickness. Reclamation works in the Silt Pond commenced in the mid of 1990s. A considerable amount of subsurface investigation inclusive of sampling, field vane and density logging tests were carried out prior to the reclamation of the Silt Pond. Since material in the Silt Pond is extremely soft, filling was done by spreading sand with high water content in thin and equal thickness lifts, allowing the stability of the slurry-like foundation. Despite the extreme care taken, failures occurred during the sand spreading phase. A large piece of high strength geotextile measuring $900m{\times}700m$ was placed to strengthen the slurry like soil foundation at locations where the ultra-soft soil was found to be exposed. Following the remedial works, the Silt Pond was again reclaimed by sand spreading up to +4.0m CD. The success of the reclamation was confirmed by marine CPT profiling.

  • PDF

Pore flow Characteristics in Seabed around Dike Due to Variation of Ground Water Level (지하수위 변화에 따른 호안 주변 지반내의 흐름특성)

  • Kim, Chang-Hoon;Kim, Do-Sam;Hur, Dong-Soo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.5
    • /
    • pp.408-417
    • /
    • 2007
  • Recently, an artificial beach has been constructed compensating for loss of the natural one caused by the development of coastal area, as well as serving as a location for recreational activities such as sea bathing. It is well known that some structure should be constructed to protect an artificial beach from the outflow due to wave action of the reclaimed sand. In general, dike is utilized as the structure to protect an artificial beach. And, one of the factors which may need to be taken into consideration for stability of dike on seabed foundation is the ground water behavior behind dike. However, the interrelated phenomena of nonlinear wave and ground water response have relatively little attention although these interactions are important for stability of structure and sand suction to the artificial beach. In this paper, the numerical wave tank was developed to clarify nonlinear wave, dike and ground water dynamic interaction, which can simulate the difference of ground water and mean water level. Using the developed numerical wave tank, the present study investigates how variation of ground water level influences hydrodynamic characteristics in seabed around dike and numerically simulates the wave fields, pore flow patterns, pore water pressures and vorticities according to variation of ground water level. Numerical results explain well how hydrodynamic characteristics in seabed around dike is affected by the variation of ground water level.

A Study on the Structure Style of Street Green Spaces on Port Island, Kobe, Japan (일본 고베시(神戶市) 포트아일랜드 가로녹지 구조 유형 연구)

  • Kwak, Jeong-In;Han, Bong-Ho;Noh, Tai-Hwan;Kwak, Nam-Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.4
    • /
    • pp.62-74
    • /
    • 2015
  • This study was carried out to provide examples of planting methods for the construction of street green spaces with abundant greenery by analyzing road type, surrounding land use and planting structures in street green spaces on Port Island, Kobe, Japan. Port Island_(total area: 826ha) is a marine cultural city located in Japan's first artificial island with facilities of urban function and port facilities. The study site was designated at 11 plots of $55{\sim}285m^2$ on Port Island, and topography structure styles were divided into four types with mounding style, slope style, slope and flat style, flat style according to the adjacent roads width. The area adjacent to the middle roads with high levels of noise and pollution set up the mounding style, slope style, slope and flat style of multi-layer structures using topographic properties. The area adjacent to small roads focused on a green strip with shrubs on a flat style. Surrounding land-uses include a public institution, housing complex, and a commercial building. The planting concept was a buffer and landspace function in case of the middle road_(lane 4) while the small road_(lane 2) was a landspace function. Planting species were diverse with Liquidambe formosana, Cinnamomum camphora, Sapium sebiferum, Cedrela sinensis, Laeocarpus sylvestris var. ellipticus, Ginkgo biloba, Prunus serrulata var. spontanea, Zelkova serrata, Quercus glauca, Juniperus chinensis, Magnolia kobus, Rhododendron spp., Camellia japonica, Abelia mosanensis, etc. Planting density was 0.02~0.08(0.04) individual/$m^2$ at the canopy layer, 0.02~0.08(0.04) individual/$m^2$ at the understory layer. Ratio of green coverage was 40.0~173.7(93.0)% at the canopy layer, 2.1~79.8(34.9)% at the understory layer and 17.9~64.2(32.9)% at the shrub layer. $Gr{\ddot{u}}volumenzahl$ was $1.43{\sim}6.67(4.13)m^3/m^2$ at the canopy layer, $0.02{\sim}2.01(0.85)m^3/m^2$ at the understory layer and $0.14{\sim}0.58(0.26)m^3/m^2$ at the shrub layer. The ratio of green coverage of street green space on Port Island was higher than that of Seoul, and particularly, the ratio of green coverage and $gr{\ddot{u}}volumenzahl$ at the shrub layer differed, compared to the main street green space in Korea. The result of this study may be applicable to other coastal reclaimed cities in terms of setting methods for street greenery considering the topography structure, planting structure and planting function.