• Title/Summary/Keyword: Receiving voltage sensitivity

Search Result 20, Processing Time 0.029 seconds

A study on configuration of acoustic package for towed array sonar using design of experiments (실험계획법을 이용한 예인 음탐기용 음향패키지 형상 연구)

  • Lee, JungHyun;Shin, Jeungho;Kwon, Oh-Cho;Kim, Gunchil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.2
    • /
    • pp.200-206
    • /
    • 2019
  • In this paper, the characteristics of receiving voltage sensitivity about acoustic package in towed array sonar is analyzed through the numerical simulation and design of experiments. Simulation results show that the variation of receiving voltage sensitivity is caused by the structural resonance mode shape on baseline acoustic package. The effect of design parameters of the acoustic package are analyzed through the design of experiments to reduce the deviation of receiving voltage sensitivity. A change of hydrophone shield can thickness (t) is the greatest effect on the deviation of receiving voltage sensitivity. As a result of water tank test, the acoustic package derived from the design of experiments has reduced deviation of receiving voltage sensitivity.

Broad-Band Underwater Acoustic Transducer for Doppler Velocity Log (도플러 속도계(DVL)를 위한 광대역 수중 음향 트랜스듀서)

  • Yun, Cheol-Ho;Lee, Yeoung-Pil;Ko, Nak Yong;Moon, Yong-Seon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.9
    • /
    • pp.755-759
    • /
    • 2013
  • A broad-band underwater acoustic transducer that uses thickness vibration mode, derived from a disk type piezoelectric ceramic, has been proposed and designed for DVL (Doppler Velocity Log). Three different types of acoustic transducer were evaluated with respect to the transmitting voltage response, receiving voltage sensitivity and bandwidth of the transducer. The effect of the acoustic impedance matching layer and backing layer is discussed. The results demonstrated that three matching layer with lossy backing layer is the best configuration for underwater transducer. The trial underwater acoustic transducer with three matching layer has a frequency bandwidth of 55%, maximum transmitting voltage response of 200 dB and a maximum receiving voltage sensitivity of -187.3 dB.

Coordinated Voltage and Reactive Power Control Strategy with Distributed Generator for Improving the Operational Efficiency

  • Jeong, Ki-Seok;Lee, Hyun-Chul;Baek, Young-Sik;Park, Ji-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1261-1268
    • /
    • 2013
  • This study proposes a voltage and reactive coordinative control strategy with distributed generator (DG) in a distribution power system. The aim is to determine the optimum dispatch schedules for an on-load tap changer (OLTC), distributed generator settings and all shunt capacitor switching on the load and DG generation profile in a day. The proposed method minimizes the real power losses and improves the voltage profile using squared deviations of bus voltages. The results indicate that the proposed method reduces the real losses and voltage fluctuations and improve receiving power factor. This paper proposes coordinated voltage and reactive power control methods that adjust optimal control values of capacitor banks, OLTC, and the AVR of DGs by using a voltage sensitivity factor (VSF) and dynamic programming (DP) with branch-and-bound (B&B) method. To avoid the computational burden, we try to limit the possible states to 24 stages by using a flexible searching space at each stage. Finally, we will show the effectiveness of the proposed method by using operational cost of real power losses and voltage deviation factor as evaluation index for a whole day in a power system with distributed generators.

Optimal Voltage and Reactive Power Scheduling for Saving Electric Charges using Dynamic Programming with a Heuristic Search Approach

  • Jeong, Ki-Seok;Chung, Jong-Duk
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.329-337
    • /
    • 2016
  • With the increasing deployment of distributed generators in the distribution system, a very large search space is required when dynamic programming (DP) is applied for the optimized dispatch schedules of voltage and reactive power controllers such as on-load tap changers, distributed generators, and shunt capacitors. This study proposes a new optimal voltage and reactive power scheduling method based on dynamic programming with a heuristic searching space reduction approach to reduce the computational burden. This algorithm is designed to determine optimum dispatch schedules based on power system day-ahead scheduling, with new control objectives that consider the reduction of active power losses and maintain the receiving power factor. In this work, to reduce the computational burden, an advanced voltage sensitivity index (AVSI) is adopted to reduce the number of load-flow calculations by estimating bus voltages. Moreover, the accumulated switching operation number up to the current stage is applied prior to the load-flow calculation module. The computational burden can be greatly reduced by using dynamic programming. Case studies were conducted using the IEEE 30-bus test systems and the simulation results indicate that the proposed method is more effective in terms of saving electric charges and improving the voltage profile than loss minimization.

Development of Split-beam Acoustic Transducer for a 50 kHz Fish Sizing Echo Sounder (50 kHz 체장어군탐지기용 분할 빔 음향 변환기의 개발)

  • Lee, Dae-Jae;Lee, Won-Sub
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.4
    • /
    • pp.413-422
    • /
    • 2011
  • An improved split-beam transducer for a 50 kHz fish-sizing echo sounder was developed. The main objective of this study was to minimize the side lobe level in the beam pattern and the distance between acoustic centers for adjacent transducer quadrants in the geometrical arrangement of array elements while maintaining a given number of transducer elements and beam width. To achieve these goals, a 32-element planar array transducer ($6{\times}6$ array with one element in each corner missing) was designed using the Dolph-Chebyshev shading function to suppress side lobes in the array beam pattern and fabricated by arranging the inter-element spacing to be substantially equal to half the wavelength using the transducer element of 0.4 times the wavelength in diameter. The performance characteristics of this split-beam transducer were evaluated in the experimental water tank of $5m{\times}5m{\times}6m$ (length${\times}$height${\times}$width). In this study, the design goal of the beam width and side lobe level for transmitting a beam pattern was initially set at $21^{\circ}$ and -30 dB, respectively. However, the measured beam width at 3 dB was $21^{\circ}$ in both directions with side lobe levels of -24.7 dB in the horizontal plane and -25.6 dB in the vertical plane. The averaged beam width at -3 dB of the receiving beam patterns for four receiving quadrants was $31.4^{\circ}$. The transmitting voltage response was 161.5 dB (re $1{\mu}Pa$/V at 1 m) at 50.23 kHz with a bandwidth of 2.16 kHz, and the averaged receiving sensitivity for four receiving quadrants was -178.13 dB (re 1 V/${\mu}Pa$) at 49.8 kHz with a bandwidth of 2.64 kHz.

Optimization of 1-3 Piezoelectric Composites Considering Transmitting and Receiving Sensitivity of Underwater Acoustic Transducers (수중 음향 트랜스듀서의 송수신 감도를 고려한 1-3형 압전복합체의 구조 최적화)

  • Lee, Jaeyoung;Pyo, Seonghun;Roh, Yongrae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.11
    • /
    • pp.790-800
    • /
    • 2013
  • The optimal structure of 1-3 piezocomposites has been determined by controlling polymer properties, ceramic volume fraction, thickness of composite and aspect ratio of the composite to maximize the TVR (transmitting voltage response), RVS (receiving voltage sensitivity) and FBW (fractional bandwidth) of underwater acoustic transducers. Influence of the design variables on the transducer performance was analyzed with equivalent circuits and the finite element method. When the piezocomposite is vibrating in a pure thickness mode, inter-pillar resonant modes are likely to occur between lattice-structured piezoceramic pillars and polymer matrix, which significantly deteriorate the performance of the piezocomposite. In this work, a new method to design the structure of the 1~3 type piezocomposite was proposed to maximize the TVR, RVS and FBW while preventing the occurrence of the inter-pillar modes. Genetic algorithm was used in the optimal design.

Pulse-echo response of 1-3 type piezoelectric composite transducers for distance measurement (거리 측정용 1-3형 복합압전체 트랜스듀서의 펄스에코 응답 특성)

  • 최헌일;박정학;이수호;사공건
    • Electrical & Electronic Materials
    • /
    • v.8 no.2
    • /
    • pp.211-216
    • /
    • 1995
  • In this study, the piezoelectric ceramics/polymer composite transducers with 1-3 connectivity have been studied. A piezoelectric ceramics PZT prepared by Wet-Dry Combination method was used as a filler in polymer matrix Eccogel. We've got the pulse-echo response for 1-3 type piezc-electric composite transducers in water. It was shown that the transmitting and receiving sensitivity of 1-3 type piezoelectric composite transducers could be improved in comparison with that- of solid PZT transducers. The reason is for that 1-3 type Piezoelectric composites have low dielectric constant and density. There was in a good agreement between the resonant frequencies calculated from one period and observed results on the Ultrasonic Transducer Analyzer. According to these results we could be figured out the distance in water by virture of the pulse-echo response.

  • PDF

A study on temperature dependent acoustic receiving characteristics of underwater acoustic sensors (수중음향센서 수온 변화에 따른 음향 수신 특성 변화 연구)

  • Je, Yub;Cho, Yohan;Kim, Kyungseop;Kim, Yong-Woon;Park, Saeyong;Lee, Jeong-Min
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.2
    • /
    • pp.214-221
    • /
    • 2019
  • In this paper, a temperature dependent acoustic receiving characteristics of underwater acoustic sensor is studied by theoretical and experimental investigations. Two different types (low mid frequency sensor and high frequency sensor) of underwater acoustic sensors are designed with different configuration of baffle and conditioning plate. The temperature dependent characteristics of the acoustic sensors are investigated within the temperature range from $-2^{\circ}C$ to $35^{\circ}C$. The material properties of the piezoelectric ceramics, molding and baffle, which are the primary materials of the acoustic sensors, are measured with temperature change. The temperature dependent RVS (Receiving Voltage Sensitivity) characteristics of the acoustic sensors are simulated by using the measured material properties. The RVS changes of the acoustic sensors are measured by changing temperature in the watertank where the acoustic sensors are installed. The measured and the simulated data show that the temperature dependent characteristics of the acoustic sensors are mainly dependent for the sound speed changes of the molding material.

Design and Development of a Broadband Ultrasonic Transducer Operating over the Frequency Range of 40 to 75 kHz (40-75 kHz의 주파수 범위에서 동작하는 광대역 초음파 변환기의 설계 및 개발)

  • Lee, Dae-Jae;Kwak, Min Son;Kang, Hee-Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.3
    • /
    • pp.292-301
    • /
    • 2014
  • The objective of this study was to design and develop a broadband ultrasonic transducer that has both wide bandwidth and high sensitivity to measure broadband echoes related to identifying fish species. A broadband ultrasonic transducer providing a nearly flat transmitting response band of 40.2-75.5 kHz with a -12 dB bandwidth of 35.3 kHz was achieved by integrating 12 tonpilz transducer elements operating at different resonance frequencies. The average transmitting voltage response, receiving sensitivity, and figure of merit values in this frequency band were 168.4 dB (re $1{\mu}Pa/V$ at 1 m), -196.8 dB (re $1V/{\mu}Pa$), and -28.4 dB, respectively. The results suggest that bandwidth and sensitivity can be widened and improved by adjusting the array pattern and the structure of tonpilz transducer elements.

Bandwidth Enhancement of Underwater Acoustic Transducer Using a Bandpass Matching Network (대역통과 정합회로를 이용한 수중음향변환기의 대역폭 확장)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.6
    • /
    • pp.702-708
    • /
    • 2019
  • The range resolution of echo sounders can be improved by enhancing the transducer bandwidth. We designed a bandpass matching network for expanding the bandwidth of a transducer by scaling in both impedance and frequency after transforming a lowpass network into a bandpass configuration for a third-order Bessel filter. We measured the effect of the Bessel matching network for a 50 kHz sandwich type transducer on the transmitting voltage response (TVR), receiving sensitivity (SRT) and figure of merit (FOM), using a chirp echo sounder system. Both the simulation and experimental results indicated that the transducer with a bandpass matching network was capable of producing a symmetrical acoustic output over a wider bandwidth (8.25 kHz) than was the transducer without a matching network (3.75 kHz). By implementing the Bessel matching network, we achieved a 120% bandwidth enhancement.