• Title/Summary/Keyword: Receiving power

Search Result 636, Processing Time 0.026 seconds

An Optimal ERP and Antenna HAAT Of 8-VSB for Digital Multimedia Broadcasting

  • Kim, Seon-Mi;Park, Jung-Jin;Choi, Dong-You;Ryu, Kwang-Jin;Choi, Dong-Woo;Park, Chang-Kyun
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.2055-2058
    • /
    • 2002
  • It designs the general description of 8-VSB DTV transmission system will be installed and operated in future on the basis of NTSC TV transmission system in operation now. First of all, it investigates a condition that can maintain optimum received field in case of ground wave broadcasting with analog NTSC and digital 8-VSB DTV. Also it calculates critical value of minimum field strength fur receiving by using field strength calculation method of Longley-Rice. The 8-VSB DTV transmission sets its goal in transmission of data with 19.39Mbps at high speed in order to be available of HDTV in the band of NTSC 6MHz. Accordingly, the optimum of field strength between transmission and receiving points most of all is important problem. So,8-VSB DTV transmission should be enlarged or effective compared with NTSC service coverage. This study is to calculate the transmission power necessary in switching from NTSC VHF to DTV UHF and from NTSC UHF to DTV UHF for maintaining service coverage that NTSC is equal to 8-VSB DTV as a result of calculation.

  • PDF

Factors Affecting the Entrapment of Primary Caregivers of Cancer Patients Receiving Home Healthcare Nursing Service (가정간호서비스를 받는 암환자 주부양자의 속박감 영향요인)

  • Mun, Mi Young;Han, Suk Jung
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.24 no.3
    • /
    • pp.292-305
    • /
    • 2017
  • Purpose: The purpose of this study was to examine the factors influencing the entrapment of primary caregivers of cancer patients. Methods: From 6 general hospitals, 146 primary caregivers of cancer patients who were receiving home healthcare nursing service were selected for the study. Regarding data collection, structured questionnaires were distributed to the caregivers for data collection. T-test, ANOVA and hierarchical regression were used for data analysis. Results: The significantly influential factors on their entrapment were caregiving time, taking turms to look after the patient, disease duration, home healthcare nursing period, quality of relationship, perceived health status, and social support. And the explanatory power was 55.1% Conclusion: To reduce primary caregivers' entrapment, it is necessary to perform comprehensive and continuous nursing intervention, and to develop a standardized home healthcare nursing intervention program, and to come up with a system for using resources available in local communities.

Design of Transceiver Front-end using Circular Sector Patch Antenna (원형 섹터 패치 안테나를 사용한 트랜시버 전단부 설계)

  • ;Tatsuo Itohv
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.4
    • /
    • pp.807-811
    • /
    • 2001
  • In this paper we proposed a dual-frequency circular sector microstrip antenna with orthogonal polarized modes and high isolation between the two feeding ports. And then we designed a transceiver operating at 5.6 GHz for transmitting and at 5.5 GHz for receiving. The good isolation provided by the proposed antenna is used as the basis for the transmit-receive filtering of transceiver. The operating frequencies and polarization characteristics of the proposed antenna is calculated by using a cavity model. The 5-parameters and radiation patterns of the antenna are measured. A power amplifier and a low noise amplifier are designed and integrated with antenna to make a transceiver, which has about 13dB transmitting gain and about 8㏈ receiving gain.

  • PDF

A Study on Transmitter and Receiver Design of Proximity Magnetic Sensor for Enhancement of Target Detection Range (표적 탐지거리 향상을 위한 근접자기센서 송수신기 설계에 관한 연구)

  • Ju, Hye-Sun;Chung, Hyun-Ju;Yang, Chang-Seob;Jeon, Jae-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1151-1158
    • /
    • 2011
  • Proximity magnetic sensor is able to detect the object target accurately in close range and it has been widely used in the underwater guided weapon system because there is no countermeasures from the target. In order to increase the damage of target by shock wave due to explosion of the underwater guided weapon system, the maximum detection range of the proximity magnetic sensor needs to be increased. In this paper, we describe the techniques of the optimum transmitting and receiving coils design using the Finite Element Method for the output power enhancement of the transmitter and the sensitivity improvement of the receiver. Finally, the proposed design techniques of the transmitter and the receiver were verified using a experimental setup and a prototype.

A Study on the Mechanical Reliability of Large-area Bi-facial Glass-to-glass Photovoltaic Modules (대면적 양면 태양광 모듈의 기계적 신뢰성 연구)

  • Yohan, Noh;Jangwon, Yoo;Jaehyeong, Lee
    • Current Photovoltaic Research
    • /
    • v.10 no.4
    • /
    • pp.111-115
    • /
    • 2022
  • For the high efficiency of the photovoltaic module, a high-output solar cell, which is the basis of photovoltaic power generation, is required. As the light receiving area of the solar cell increases, the light receiving area of the photovoltaic module also increases. Accordingly, recent trend is to use large-area solar cells such as M6 and M8 instead of M2-based solar cells for manufacturing the photovoltaic module and a study on the mechanical stiffness of the module with increased size is required. In this study, a mechanical load test corresponding to IEC-61215 was performed among the reliability tests of large-area photovoltaic modules. In order to confirm the degree to which the mechanical load test affects the photovoltaic module, the output and EL images were checked by sequentially increasing the pressure by 600 Pa at a pressure of 2400 Pa. Also, factors such as output and efficiency of large-area photovoltaic modules were verified through mechanical load testing of actual large-area photovoltaic modules and the rate of change was very small at 1%.

Development of Intelligent Switchgear Monitoring System based on Smartphone (스마트폰 기반의 지능형 수배전반 모니터링 시스템 구현)

  • Jung, Hae-Kyung;Jeon, Gam-Pyo;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.378-379
    • /
    • 2012
  • Nowadays, great energy consumption in advanced electrical industry has called up the great y efficiency. Electric power IT industry such as intelligent electric power system is receiving great attention and being marked up as a new growth engine. Through Intelligent electric power system, the electric power supply can be balance optimized according to demand, giving huge cost savings advantage for energy imports, infrastructure construction and operation. Nevertheless, the intelligent system promotes better reliability in power supply. Manual electric power management using man power appears to be non-practical. Real time electric power management on all facilities and equipment can be done through an intelligent electric power system, any accident break out issue can be easily recorded and recognized. In this paper, a fully integrated intelligent switchgear electric management system is developed to monitor and remote control the electrical switch based on smart phone. The proposed system is superior than the existing switchgear management system's weakness and can sharply improve effectiveness and stability with low cost. In future, the proposed system is expected to be greatly contributed to the advancement of the IT industry in electric power management.

  • PDF

Data Acquisition and Statistical Processing of Insulation Resistance for High-Power Cables in Operation (운전 중 고전력 케이블의 절연저항 데이터의 취득과 통계적 처리 방법)

  • Park, Sung-Hee;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.181-186
    • /
    • 2018
  • With progress in industrialization, facilities for generating, delivering, and receiving high levels of electric power are in great demand. The scale of electric power equipment is increasing in both size and complexity. This has contributed to the development of our modern, high-tech and information-based society. However, if the generation of electric power is suspended due to unexpected accidents at power facilities or power stations, a range of equipment the operations of which are dependent on electric power can be damaged, causing substantial socioeconomic losses in an industrial society. A great deal of time and money would be expended to repair damaged facilities at a power station, causing enormous economic loss. In order to detect the deterioration processes of power cables, and to prevent the destruction of power cables, the operation status of power cables should be monitored on a regular basis. We studied the method in order to improve accuracy and reliability for diagnosising the junction where accident occurs frequently. We present the method of data acquisition and statistical processing.

Design of External Coil System for Reducing Artifact of MR Image due to Implantable Hearing Aid (이식형 보청기에 의한 자기공명 영상의 인공음영 축소를 위한 외부 코일 시스템 설계)

  • Ahn, Hyoung Jun;Lim, Hyung-Gyu;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.375-385
    • /
    • 2016
  • Recently, several implantable hearing aids such as cochlear implant, middle ear implant, etc., which have a module receiving power and signal from outside the body, are frequently used to treat the hearing impaired patients. Most of implantable hearing aids are adopted permanent magnet pairs to couple between internal and external devices for the enhancement of power transmission. Generally, the internal device which containing the magnet in the center of receiving coil is implanted under the skin of human temporal bone. In case of MRI scanning of a patient with the implantable hearing aid, however, homogeneous magnetic fields of the MRI might be interfered by the implanted magnet. For the above reasons, the MR image is degraded by large area of artifact, so that diagnostics are almost impossible in deteriorated region. In this paper, we proposed an external coil system that can reduce the artifact of MR image due to the internal coupling magnet. By finite element analysis estimating area of MR artifact according to varying current and shape of the external coil, optimal coil parameters were extracted. Finally, the effectiveness of the proposed external coil system was verified by confirming the artifact at real MRI scan.

Small Hydraulic Power Generation using the Discharging Seawater from LNG Receiving Terminal (LNG 인수기지의 방류해수를 이용한 소수력발전 개발방안)

  • Ha, Jongmann;Chae, Jeongmin;Son, Whaseong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.192.2-192.2
    • /
    • 2010
  • 일반적 의미의 소수력발전은 계곡이나 저낙차의 하천에서 시도되었으나, 한국의 지형과 강수패턴등은 소수력발전을 활성화하기에 어려운 점들이 있었다. 이에 최근에는 정수장, 하수처리장등과 같은 인공구조물에 소수력발전을 설치 운영하는 방향으로 가고 있으며, 특히 화력발전소 냉각공정에 사용되는 해수를 이용한 소수력발전이 크게 성공하였고 확대설치 되어가고 있다. 해안에 위치하는 LNG인수기지에서는 LNG의 기화에 해수를 열원으로 사용하며, 기화공정에서 열교환 후 바다에 배출된다. 이 때 기화해수와 공기와의 접촉으로 생성된 거품은 해양미생물과의 복합작용으로 쉽게 깨어지지 않고 바다로 떠내려가게 된다. 이러한 거품은 시각적 거부감으로 인하여 인근어민들의 불편함을 야기하고 있으며, 또한 배출해수와 일반해수와의 온도차로 인한 인근 어장이나 양식장의 어획고에 미칠 수 있는 부작용의 가능성에 대한 우려는 더욱 방류해수의 적절한 처리를 필요로 하고 있다. 이러한 방류해수의 거품생성을 해결하는 데 있어 근본적인 해결방법은 심층배수법인데, 심층배수 구조물에 발전수차를 추가 설치만 하면 수력발전이 가능하다. 방류해수의 거품관련 환경문제를 해결하면서 동시에 청정전력을 생산할 수 있는 해양소수력발전에 대하여 KOGAS에서는 LNG 인수기지에의 적용가능성을 분석하고 있으며, 방류해수의 낙차와 조수간만의 차를 이용하는 해양소수력발전을 LNG 인수기지에의 적용하는 것으로는 세계최초의 시도이다. 주변지형에 따른 입지여건을 분석하고, 해수계통분석, 소수력발전방법, 수차종류, 수차용량, 수차개수, pond의 크기등을 결정하고, 수리해석 및 경제성분석을 수행할 것이며 소수력발전의 타당성여부에 대한 가늠을 잡고자 한다.

  • PDF

Communications Protocol Used in the Wireless Token Rings for Bird-to-Bird

  • Nakajima, Isao;Juzoji, Hiroshi;Ozaki, Kiyoaki;Nakamura, Noboru
    • Journal of Multimedia Information System
    • /
    • v.5 no.3
    • /
    • pp.163-170
    • /
    • 2018
  • We developed a multicast communication packet radio protocol using a time-sharing tablet system ("wireless token ring") to achieve the efficient exchange of files among packet radio terminals attached to swans. This paper provides an overview of the system and the protocol of the packet communications. The packet device forming the main part of the transceiver developed is the Texas Instruments CC2500. This device consists of one call-up channel and one data transmission channel and could improve error frame correction using FEC (forward error correction) with 34.8 kbps MSK and receiving power of at least -64 dBm (output 1 dBm at distance of 200 m using 3 dBi antenna). A time-sharing framework was determined for the wireless token ring using call sign ordinals to prevent transmission right loss. Tests using eight stations showed that resend requests with the ARQ (automatic repeat request) system are more frequent for a receiving power supply of -62 dBm or less. A wireless token ring system with fixed transmission times is more effective. This communication protocol is useful in cases in which frequency resources are limited; the energy consumed is not dependent on the transmission environment (preset transmission times); multiple terminals are concentrated in a small area; and information (position data and vital data) is shared among terminals under circumstances in which direct communication between a terminal and the center is not possible. The method allows epidemiological predictions of avian influenza infection routes based on vital data and relationships among individual birds based on the network topology recorded by individual terminals. This communication protocol is also expected to have applications in the formation of multiple in vivo micromachines or terminals that are inserted into living organisms.