• Title/Summary/Keyword: Receiver sensitivity

Search Result 574, Processing Time 0.031 seconds

Association between Texture Analysis Parameters and Molecular Biologic KRAS Mutation in Non-Mucinous Rectal Cancer (원발성 비점액성 직장암 환자에서 자기공명영상 기반 텍스처 분석 변수와 KRAS 유전자 변이와의 연관성)

  • Sung Jae Jo;Seung Ho Kim;Sang Joon Park;Yedaun Lee;Jung Hee Son
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.406-416
    • /
    • 2021
  • Purpose To evaluate the association between magnetic resonance imaging (MRI)-based texture parameters and Kirsten rat sarcoma viral oncogene homolog (KRAS) mutation in patients with non-mucinous rectal cancer. Materials and Methods Seventy-nine patients who had pathologically confirmed rectal non-mucinous adenocarcinoma with or without KRAS-mutation and had undergone rectal MRI were divided into a training (n = 46) and validation dataset (n = 33). A texture analysis was performed on the axial T2-weighted images. The association was statistically analyzed using the Mann-Whitney U test. To extract an optimal cut-off value for the prediction of KRAS mutation, a receiver operating characteristic curve analysis was performed. The cut-off value was verified using the validation dataset. Results In the training dataset, skewness in the mutant group (n = 22) was significantly higher than in the wild-type group (n = 24) (0.221 ± 0.283; -0.006 ± 0.178, respectively, p = 0.003). The area under the curve of the skewness was 0.757 (95% confidence interval, 0.606 to 0.872) with a maximum accuracy of 71%, a sensitivity of 64%, and a specificity of 78%. None of the other texture parameters were associated with KRAS mutation (p > 0.05). When a cut-off value of 0.078 was applied to the validation dataset, this had an accuracy of 76%, a sensitivity of 86%, and a specificity of 68%. Conclusion Skewness was associated with KRAS mutation in patients with non-mucinous rectal cancer.

Clinical Application of Serum CEA, SCC, Cyfra21-1, and TPA in Lung Cancer (폐암환자에서 혈청 CEA, SCC, Cyfra21-1, TPA-M 측정의 의의)

  • Lee, Jun-Ho;Kim, Kyung-Chan;Lee, Sang-Jun;Lee, Jong-Kook;Jo, Sung-Jae;Kwon, Kun-Young;Han, Sung-Beom;Jeon, Young-June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.785-795
    • /
    • 1997
  • Background : Tumor markers have been used in diagnosis, predicting the extent of disease, monitoring recurrence after therapy and prediction of prognosis. But the utility of markers in lung cancer has been limited by low sensitivity and specificity. TPA-M is recently developed marker using combined monoclonal antibody of Cytokeratin 8, 18, and 19. This study was conducted to evaluate the efficacy of new tumor marker, TPA-M by comparing the estabilished markers SCC, CEA, Cyfra21-1 in lung cancer. Method : An immunoradiometric assay of serum CEA, sec, Cyfra21-1, and TPA-M was performed in 49 pathologically confirmed lung cancer patients who visited Keimyung University Hospital from April 1996 to August 1996, and 29 benign lung diseases. Commercially available kits, Ab bead CEA (Eiken) to CEA, SCC RIA BEAD (DAINABOT) to SCC, CA2H (TFB) to Cyfra2H. and TPA-M (DAIICHI) to TPA-M were used for this study. Results : The mean serum values of lung cancer group and control group were $10.05{\pm}38.39{\mu}/L$, $1.59{\pm}0.94{\mu}/L$ in CEA, $3.04{\pm}5.79{\mu}/L$, $1.58{\pm}2.85{\mu}/L$ in SCC, $8.27{\pm}11.96{\mu}/L$, $1.77{\pm}2.72{\mu}/L$ in Cyfra21-1, and $132.02{\pm}209.35\;U/L$, $45.86{\pm}75.86\;U/L$ in TPA-M respectively. Serum values of Cyfra21-1 and TPA-M in lung cancer group were higher than control group (p<0.05). Using cutoff value recommended by the manufactures, that is $2.5{\mu}/L$ in CEA, $3.0{\mu}/L$ in Cyfra21-1, 70.0 U/L in TPA-M, and $2.0{\mu}/L$ in SCC, sensitivity and specificity of lung cancer were 33.3%, 78.6% in CEA, 50.0%, 89.7% in Cyfra21-1, 52.3%, 89.7% in TPA-M, 23.8%, 89.3% in SCC. Sensitivity and specificity of nonsmall cell lung cancer were 36.1%, 78.1% in CEA, 50.1%, 89.7% in Cyfra21-1, 53.1%, 89.7% in TPA-M, 33.8%, 89.3% in SCC. Sensitivity and specificity of small cell lung cancer were 25.0%, 78.5% in CEA, 50.0%, 89.6% in Cyfra21-1, 50.0%, 89.6% in TPA-M, 0%, 89.2% in SCC. Cutoff value according to ROC(Receiver operating characteristics) curve was $1.25{\mu}/L$ in CEA, $1.5{\mu}/L$ in Cyfra2-1, 35 U/L in TPA-M, $0.6{\mu}/L$ in SCC. With this cutoff value, sensitivity, specificity, accuracy and kappa index of Cyfra21-1 and TPA-M were better than CEA and SCC. SCC only was related with statistic significance to TNM stages, dividing to operable stages(TNM stage I to IIIA) and inoperable stages (IIIB and IV) (p<0.05). But no tumor markers showed any correlation with significance with tumor size(p>0.05). Conclusion : Serum TPA-M and Cyfra21-1 shows higher sensitivity and specificity than CEA and SCC in overall lung cancer and nonsmall cell lung cancer those were confirmed pathologically. SCC has higher specificity in nonsmall cell lung cancer. And the level of serum sec are signiticantly related with TNM staging.

  • PDF

Cutoff Values of Body Mass Index and Body Fat Measures for Metabolic Syndrome in Korean Population (한국인에서 대사증후군의 선별검사로서 체성분 분석 및 체질량지수의 타당성연구)

  • Lee, Hyun-Jae;Kim, Byoung-Gwon;Kim, Joon-Youn;Kim, Jung-Man;Yoo, Byung-Chul;Kim, Eun-Jeong;Hong, Young-Seoub
    • Journal of Life Science
    • /
    • v.20 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • This study investigated cut-off values of body mass index (BMI) and body fat measures for metabolic syndrome (MS) in elderly Koreas. Questionnaire surveys, anthropometric measurements, medical examinations, and body composition analyses were conducted for 10,077 subjects aged 40-65 years in the health examinee cohort in Korea between 2004 and 2006. Cut-off values were identified using receiver-operating characteristic (ROC) curve analysis for both men and women. Stratified analyses by weight range (<60, 60-69, 70-79, and 80-89, ${\geq}90\;kg$ for men; <50, 50-59, 60-69, 70-79, ${\geq}80\;kg$ for women) were conducted. Among male subjects, the cut-off points were $25.5\;kg/m^2$ for BMI with a sensitivity of 70.0% and a specificity of 72.0%, and 26.1% for body fat percentage with a sensitivity of 60.6% and a specificity of 76.4%. Among female subjects, the cutoff points were $24.1\;kg/m^2$ for BMI with a sensitivity of 73.3% and a specificity of 68.8%, and 31.5% for body fat percentage with a sensitivity of 76.7% and a specificity of 65.6%. Stratified analysis by weight range showed that the cutoff points of BMI and body fat measures tended to higher as weight level increased. The results of our study suggest cut-off values of BMI and body fat measure for MS were similar to the general obesity criteria in Korea.

Implant Isolation Characteristics for 1.25 Gbps Monolithic Integrated Bi-Directional Optoelectronic SoC (1.25 Gbps 단일집적 양방향 광전 SoC를 위한 임플란트 절연 특성 분석)

  • Kim, Sung-Il;Kang, Kwang-Yong;Lee, Hai-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.52-59
    • /
    • 2007
  • In this paper, we analyzed and measured implant isolation characteristics for a 1.25 Gbps monolithic integrated hi-directional (M-BiDi) optoelectronic system-on-a-chip, which is a key component to constitute gigabit passive optical networks (PONs) for a fiber-to-the-home (FTTH). Also, we derived an equivalent circuit of the implant structure under various DC bias conditions. The 1.25 Gbps M-BiDi transmit-receive SoC consists of a laser diode with a monitor photodiode as a transmitter and a digital photodiode as a digital data receiver on the same InP wafer According to IEEE 802.3ah and ITU-T G.983.3 standards, a receiver sensitivity of the digital receiver has to satisfy under -24 dBm @ BER=10-12. Therefore, the electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysed and measured results of the implant structure, the M-BiDi SoC with the implant area of 20 mm width and more than 200 mm distance between the laser diode and monitor photodiode, and between the monitor photodiode and digital photodiode, satisfies the electrical crosstalk level. These implant characteristics can be used for the design and fabrication of an optoelectronic SoC design, and expended to a mixed-mode SoC field.

Significance of Serum Ferritin in Multiple Trauma Patients with Acute Respiratory Distress Syndrome (다발성 외상 환자에서 발생되는 급성 호흡 곤란 증후군의 예측 인자로서 혈청 페리틴의 의의)

  • Ji, Yae-Sub;Kim, Nak-Hee;Jung, Ho-Geun;Ha, Dong-Yeup;Jung, Ki-Hoon
    • Journal of Trauma and Injury
    • /
    • v.20 no.2
    • /
    • pp.57-64
    • /
    • 2007
  • Purpose: Clinically, acute respiratory distress syndrome (ARDS) occurs within 72 hours after acute exposure of risk factors. Because of its high fatality rate once ARDS progresses, early detection and management are essential to reduce the mortality rate. Accordingly, studies on early changes of ARDS were started, and serum ferritin, as well the as injury severity score (ISS), which has been addressed in previous studies, thought to be an early predictive indicator for ARDSMethods: From March 2003 to March 2005, we investigated 50 trauma patients who were admitted to the intensive care unit in Dongguk University Medical Center, Gyeongju. The patients were characterized according to age, sex, ISS, onset of ARDS, time onset of ARDS, serum ferritin level (posttraumatic $1^{st}\;&\;2^{nd}$ day), amount of transfused blood, and death. Abdominal computed topography was performed as an early diagnostic tool to evaluate the onset of ARDS according to its diagnostic criteria. The serum ferritin was measured by using a $VIDAS^{(R)}$ Ferritin (bioMeriux, Marcy-1' Etoile, France) kit with an enzyme-linked fluorescent assay method. For statistical analysis, Windows SPSS 13.0 and MedCalc were used to confirm the probability of obtaining a predictive measure from the receiver operating characteristics (ROC) curve. Results: The ISS varied from 14 to 66 (mean: 33.8) whereas the onset of ARDS could be predicted with the score above 30 (sensitivity: 90.0%, specificity: 60.0%, p<0.05). On the posttraumatic $1^{st}$ day, the serum ferritin levels were measured to be from 31 mg/dL to 1,200 mg/dL (mean: 456 mg/dL), and the onset of ARDS could be predicted when the value was over 340 mg/dL (sensitivity: 80.0%, specificity: 65.0%, p<0.05). On the posttraumatic $2^{nd}$ day, the serum ferritin levels were measured to be from 73 mg/dL to 1,200 mg/dL (mean: 404 mg/dL), and the onset of ARDS could be predicted when the value was over 627 mg/dL (sensitivity: 60.0%, specificity: 92.5%, p<0.05). The serum ferritin levels and the ISS were significantly higher on the posttraumatic $1^{st}$ and $2^{nd}$ day in the ARDS group, suggesting that they are suitable indices predicting the onset of ARDS, however relationship between the serum ferritin levels and the ISS was not statistically significant. Conclusion: In this study, we discovered increasing serum ferritin levels in multiple- trauma patients on the posttraumatic $1^{st}$ & $2^{nd}$ day and concluded that both the serum ferritin level and the ISS were good predictors of ARDS. Although they do not show statistically significant relationship to each other, they can be used as independent predictive measures for ARDS. Since ARDS causes high mortality, further studies, including the types of surgery and the methods of anesthesia on a large number of patients are essential to predict the chance of ARDS earlier and to reduce the incidence of death.

Gallbladder Ejection Fraction Using $^{99m}Tc$-DISIDA Scan in Diabetic Autonomic Neuropathy (당뇨병성 자율 신경병증에서 $^{99m}Tc$-DISIDA를 이용한 담낭 배출율에 관한 연구)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;An, Jun-Hyup;Yoo, Seok-Dong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.55-61
    • /
    • 2000
  • Purpose: We performed this study to evaluate the changes of gallbladder ejection fraction (GBEF) in diabetic patients with or without autonomic neuropathy. Materials and Methods: This study included 37 diabetic patients (25 women, 12 men, mean age 51 years) and 24 normal controls (10 women, 14 men, mean age 38 years). After intravenous injection of 185 MBq of $^{99m}Tc$-DISIDA, serial anterior abdominal images were acquired before and after fatty meal. Regions of interest were applied on gallbladder and right hepatic lobe on 60 and 90 minute images to calculate GBEF. Results: GBEF was significantly reduced in diabetes with autonomic neuropathy ($43{\pm}12.3%$) and without autonomic neuropathy ($57.5{\pm}13.2%$) compared with normal controls ($68{\pm}11.6%$, p<0.05). And also, GBEF was significantly reduced in diabetes with autonomic neuropathy compared with diabetes without autonomic neuropathy (p<0.05). Fasting blood glucose level, age, sex, hemoglobin Alc, body mass index, serum lipid level were not different in these two diabetic patient groups (p>0.05). When 50.2% of GBEF was used as the criteria for diabetic autonomic neuropathy, the sensitivity and specificity were 80%, 76.5%, respectively. The area under receiver operating characteristic curve was 0.846. Conclusion: GBEF of diabetic patients with autonomic neuropathy was significantly reduced than that of diabetic patients without autonomic neuropathy.

  • PDF

Considerations of Environmental Factors Affecting the Detection of Underwater Acoustic Signals in the Continental Regions of the East Coast Sea of Korea

  • Na, Young-Nam;Kim, Young-Gyu;Kim, Young-Sun;Park, Joung-Soo;Kim, Eui-Hyung;Chae, Jin-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.2E
    • /
    • pp.30-45
    • /
    • 2001
  • This study considers the environmental factors affecting propagation loss and sonar performance in the continental regions of the East Coast Sea of Korea. Water mass distributions appear to change dramatically in a few weeks. Simple calculation with the case when the NKCW (North Korean Cold Water) develops shows that the difference in propagation loss may reach in the worst up to 10dB over range 5km. Another factor, an eddy, has typical dimensions of 100-200km in diameter and 150-200m in thickness. Employing a typical eddy and assuming frequency to be 100Hz, its effects on propagation loss appear to make lower the normal formation of convergence zones with which sonars are possible to detect long-range targets. The change of convergence zones may result in 10dB difference in received signals in a given depth. Thermal fronts also appear to be critical restrictions to operating sonars in shallow waters. Assuming frequency to be 200Hz, thermal fronts can make 10dB difference in propagation loss between with and without them over range 20km. An observation made in one site in the East Coast Sea of Korea reveals that internal waves may appear in near-inertial period and their spectra may exist in periods 2-17min. A simulation employing simple internal wave packets gives that they break convergence zones on the bottom, causing the performance degradation of FOM as much as 4dB in frequency 1kHz. An acoustic experiment, using fixed source and receiver at the same site, shows that the received signals fluctuate tremendously with time reaching up to 6.5dB in frequencies 1kHz or less. Ambient noises give negative effects directly on sonar performance. Measurements at some sites in the East Coast Sea of Korea suggest that the noise levels greatly fluctuate with time, for example noon and early morning, mainly due to ship traffics. The average difference in a day may reach 10dB in frequency 200Hz. Another experiment using an array of hydrophones gives that the spectrum levels of ambient noises are highly directional, their difference being as large as 10dB with vertical or horizontal angles. This fact strongly implies that we should obtain in-situ information of noise levels to estimate reasonable sonar performance. As one of non-stationary noise sources, an eel may give serious problems to sonar operation on or under the sea bottoms. Observed eel noises in a pier of water depth 14m appear to have duration time of about 0.4 seconds and frequency ranges of 0.2-2.8kHz. The 'song'of an eel increases ambient noise levels to average 2.16dB in the frequencies concerned, being large enough to degrade detection performance of the sonars on or below sediments. An experiment using hydrophones in water and sediment gives that sensitivity drops of 3-4dB are expected for the hydrophones laid in sediment at frequencies of 0.5-1.5kHz. The SNR difference between in water and in sediment, however, shows large fluctuations rather than stable patterns with the source-receiver ranges.

  • PDF

The Validation Study of Beck Depression Scale 2 in Korean Version (한국판 벡 우울 척도 2판의 타당화 연구)

  • Lim, Sun-Young;Lee, Eun-Jeong;Jeong, Seong-Won;Kim, Hee-Chul;Jeong, Cheol-Ho;Jeon, Tae-Yeon;Yi, Min-Soo;Kim, Jae-Min;Jo, Hyeon-Ju;Kim, Jeong-Beom
    • Anxiety and mood
    • /
    • v.7 no.1
    • /
    • pp.48-53
    • /
    • 2011
  • Objective : Korean Version of Beck-II Depression Inventory to verify the reliability and validity of the proposed standards are practical and standardized, cut-off score by establishing a baseline indicating the presence of depression and depression On in the evaluation was to evaluate the clinical usefulness. Methods : 739 patients with major depression using the SCID and normal controls were 302 study subjects. Of patients with clinically significant medical condition, or psychotic disorders, organic mental disorder, epilepsy or seizure disorder, eating disorders are associated with patients taking anti-convulsants experienced in the past, patients were excluded from the study. Results : The main findings of this study were as follows. First, with respect to the KBDI-II items, the correlation between them ranged from 0.51 to 0.74, and was 0.60 over all questions. Further, the overall correlation of the KBDI-II plates showing confidence 'normal' than it was verified that. Second, the BDIII was used in each group to examine internal consistency and thus, whether Cronbach's alpha values were greater than 0.94. Third, the principal component analysis sought to extract factors in a way consistent with the results inspected last 3 factors were extracted and the total variance explained was 47.3%. Fourth, the Cutting calculated the score on the KBDI-II for ROC (Receiver operator characteristic) analysis yielding 18 dot, with the highest sensitivity and specificity was seen. Conclusion : Based on the results of this Study, the KBDI-II cut-off point should be valid as prescribed in 18 is considered.

Application of Tumor Markers SCC-Ag, CEA, and TPA in Patients with Cervical Precancerous Lesions

  • Farzaneh, Farah;Shahghassempour, Shapour;Noshine, Bahram;Arab, Maliheh;Yaseri, Mehdi;Rafizadeh, Mitra;Alizadeh, Kamyab
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.9
    • /
    • pp.3911-3914
    • /
    • 2014
  • Background: To determine the potential clinical utility of tumor markers CEA, TPA, and SCC-Ag for early detection of cervical precancerous lesions. Materials and Methods: A case-control study was carried out on 120 women (46 patients with histologically confirmed cervical precancerous lesions and 74 healthy controls). The significance of serum selected tumor markers in early detection of cervical intraepithelial neoplasia (CIN) were assessed. Results: Of the case group, the rates of CIN I, II, III, was 69.6%, 23.9%, and 6.5%, respectively. According to the manufacturer's cut-off values of 2ng/ml, 5ng/ml, and 70 U/ml for SCC-Ag, CEA and TPA tests, in that order, SCC-Ag test had a sensitivity of 13%, but CEA and TPA tests could not distinguish between case and control groups. The diagnostic sensitivities were highest at cut-off values of 0.55 ng/ml for SCC-Ag, 2.6ng/ml for CEA, and 25.5 U/ml for TPA which were 93%, 61%, and 50%, respectively. However, the area under the receiver operating characteristic curve was the largest for SCC-Ag (0.95 vs. 0.61 and 0.60 for CEA and TPA, respectively). Moreover, there was a highly significant direct correlation between SCC-Ag concentration and the degree of cervical precancerous lesions (r=0.847, p<0.001). Conclusions: The new cutoff of 0.5 for SCC-Ag test might be useful as a tumor marker in Iranian patients with CIN and it needs to be more evaluated by studies with larger populationa.

Prostate-specific Antigen Velocity (PSAV) and PSAV per Initial Volume (PSAVD) for Early Detection of Prostate Cancer in Chinese Men

  • Zheng, Xiang-Yi;Zhang, Peng;Xie, Li-Ping;You, Qi-Han;Cai, Bo-Sen;Qin, Jie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.11
    • /
    • pp.5529-5533
    • /
    • 2012
  • Aim: To investigate the utility of prostate-specific antigen velocity (PSAV) and PSAV per initial volume (PSAVD) for early detection of prostate cancer (PCa) in Chinese men. Methods: Between January 2009 and June 2012, a total of 193 men (aged 49-84 years, median 67 years) with at least 2 transrectal ultrasonography (TRUS) procedures and concurrent serum PSA measurements underwent prostate biopsy because of suspicion of PCa. The total group were classified into PCa and non-PCa groups, and the variables of the two groups were compared. Univariate and multivariate analyses were used to investigate which variables were predictove. The diagnostic values of PSAV, PSAVD and prostate-specific antigen density (PSAD) were compared using receiver operating characteristic (ROC) analysis. Results: Prostate cancer was diagnosed in 44 (22.8%) of the 193 men. There were significant differences between the groups in last and initial prostate volumes determined by TRUS, initial age, last serum PSA levels, PSAV, PSAD and PSAVD. After adjusting for confounding factors, the odds ratios of PCa across the quartile of PSAVD were 1, 4.06, 10.6, and 18.9 (P for trend <0.001).The area under the ROC curves (AUCs) of PSAD (0.779) and PSAVD (0.776) were similar and both significantly greater than that of PSA (AUC 0.667). PSAVD was a significantly better indicator of PCa than PSAV (AUC 0.736). There was no statistical significant difference between the AUC of PSAV and that of last serum PSA level. The sensitivity and specificity of PSAVD at a cutoff of 0.023ng in participants with last serum PSA levels of 4.0ng/mL-10.0ng was 73.7% and 70.7%, respectively. Conclusions: The results of this study demonstrated PSAVD may be a useful tool in PCa detection, especially in those undergoing previous TRUS examination.